Vtomex S Brochure

V tome x s is a versatile high resolution system for 2D x-ray inspection and 3D failureand structure analysis as well as for 3D metrology. The system may optionally be equipped with both, a 180 kV / 15 W high-power nanofocus X-ray tube and a 240 kV / 320 W microfocus tube.

Uploaded by

Bryan Tatone
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
540 views1 page

Vtomex S Brochure

V tome x s is a versatile high resolution system for 2D x-ray inspection and 3D failureand structure analysis as well as for 3D metrology. The system may optionally be equipped with both, a 180 kV / 15 W high-power nanofocus X-ray tube and a 240 kV / 320 W microfocus tube.

Uploaded by

Bryan Tatone
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

GE Sensing & Inspection Technologies phoenix|x-ray

v|tome|x s versatile and exible CT system


The v|tome|x s is a versatile high resolution system for 2D x-ray inspection and 3D failure- and structure analysis as well as for 3D metrology. To allow high flexibility, the v|tome|x s may optionally be equipped with both, a 180 kV / 15 W high-power nanofocus X-ray tube and a 240 kV / 320 W microfocus tube. Due to this unique combination, the system is an ideal tool for a wide range of applications from extreme high resolution scans of low absorbing materials as well as for 3D analysis of high absorbing objects up to 260 mm in diameter. To ensure the high quality of the reconstructed volume, phoenix|x-ray has developed a variety of effective software, e.g. for automatic beam-hardening correction. Innovative modules for automatic geometry calibration, or ROI-CT support the ease of use.

Glass bre reinforced plastic

Cavities in a plastic gear wheel

Micropart CAD variance analysis

Unique nanofocus-microfocus dual tube combination Maximum voxel resolution <2 m (3D) nanoCT configuration for voxel resolution <1m (3D) Maximum sample size 420 mm in height x 260 mm in diameter Maximum sample weight 10 kg Fast CT acquisition by high dynamic temperature-stabilized detector

240 kV / 320 W max. tube power Longlife open X-ray tubes Metrology package for dimensional measuring with extreme high precision Automated generation of first article inspection reports in <1 hour possible Excellent software modules for highest CT quality and ease of use Accelerated 3D reconstruction results within a few minutes by velo|CT
Cavities in an Al casting GE Sensing & Inspection Technologies GmbH phoenix|x-ray Niels-Bohr-Str. 7 D-31515 Wunstorf | Germany Tel.: + 49 5031.172-0 Fax.: + 49 5031.172-299 phoenix-info@ge.com