Index of ingress protection
IPxx degree of protection of enclosures of electrical equipment in accordance with standards IEC 60529 and EN 60529 - Protection against solid bodies - Protection against liquids - Protection against impact as per EN 50102 standard 1st figure: protection against solid bodies
IP
0 1 50mm
2nd figure: protection against liquids
IP test
no protection protected against vertically falling drops of water (condensation) protected against drops of water falling up to 15 from the vertical protected against drops of water falling up to 60 from the vertical protected against splashing water from all directions protected against jets of water from all directions protected against powerful jets of water from all directions protected against the effects of temporary immersion in water protected against the continuous effects of immersion in water having regard to specific conditions
tests
no protection protected against solid bodies of 50 mm and greater (e.g. accidental contact with the hand) protected against solid bodies of 12.5 mm and greater (e.g. finger) 2.5mm
0 1
12.5mm 2
3 protected against solid bodies of 2.5 mm and greater (e.g. tools, wires) 4 protected against solid bodies larger than 1 mm (e.g.thin tools and fine wires) protected against dust (no harmful deposit) completely protected against dust 7
1mm
Index of mechanical protection
Code IK Impact Energy (in joule) IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 0.2 0.35 0.5 0.7 1 2 5 10 20
No 0.15 protection