OptiX OSN 7500
Commissioning Guide                                                                                                                            Contents
                                                                                                                               Contents
1 Preparations for Equipment Commissioning .................................................................................1-1
         1.1 Instruments and Tools.................................................................................................................... 1-2
         1.2 Engineering Information................................................................................................................ 1-3
         1.3 Connection Points Position ............................................................................................................ 1-4
         1.4 External Check .............................................................................................................................. 1-6
         1.5 Requirements for Commissioning Engineers ................................................................................. 1-7
         1.6 Commissioning Items .................................................................................................................... 1-8
 T2-040439-20060320-C-1.50                             Huawei Technologies Proprietary                                                                      i
OptiX OSN 7500
Commissioning Guide                                                                                                     Figures
                                                                                                             Figures
      Figure 1-2 Connection points position of OptiX OSN 7500................................................................. 1-4
T2-040439-20060320-C-1.50                   Huawei Technologies Proprietary                                                   iii
OptiX OSN 7500
Commissioning Guide                                                                                                                            Tables
                                                                                                                                  Tables
      Table 1-1 Organisation of chapter 1 .................................................................................................... 1-1
      Table 1-2 Instruments and tools for commissioning ............................................................................. 1-2
      Table 1-3 Numbering and functions referred to the connection points .................................................. 1-5
      Table 1-4 Testing items ....................................................................................................................... 1-8
T2-040439-20060320-C-1.50                          Huawei Technologies Proprietary                                                                    v
OptiX OSN 7500
Commissioning Guide                                            1 Preparations for Equipment Commissioning
                              1           Preparations for Equipment
                                                     Commissioning
                This chapter describes the preparations for commissioning. Table 1-1 shows the
                organisation of this chapter.
                Table 1-1 Organisation of chapter 1
                 Section                               Describes the …
                 1.1 Instruments and Tools             Instruments and tools needed.
                 1.2 Engineering Information           Engineering documents needed.
                 1.3 Connection Points Position        Connection points position.
                 1.4 External Check                    External environment required.
                 1.5 Requirements for                  Requirements for commissioning engineers.
                 Commissioning Engineers
                 1.6 Commissioning Items               Commissioning items.
T2-040439-20060320-C-1.50           Huawei Technologies Proprietary                                   1-1
                                                                                              OptiX OSN 7500
1 Preparations for Equipment Commissioning                                                 Commissioning Guide
1.1 Instruments and Tools
                  Table 1-2 shows the instruments and tools for commissioning.
                  Table 1-2 Instruments and tools for commissioning
                   Name                Used for …
                   SDH analyser        Testing multiplex section switching time, frequency deviation and
                                       jitter at optical or electrical interfaces, and so on.
                   Optical power       Testing the actual received optical power, receiver sensitivity, and
                   meter               receiver overload at optical interfaces.
                   Fixed attenuator    Attenuating strong optical power received at optical interfaces to
                                       avoid damage.
                   Laptop computer     NE commissioning and Ethernet indexes test.
                   Multimetre          Testing voltage, resistance, current intensity.
                   Fibre jumper        Transfer during optical power test of optical interfaces at the ODF
                                       side.
                   BER tester          Testing bit errors at electrical interfaces.
                   Adjustable          Testing receiver overload at optical interfaces and testing receiver
                   attenuator          sensitivity.
                   Data analyser       Testing Ethernet services.
                   ATM analyser        Testing ATM services.
1-2                                   Huawei Technologies Proprietary                 T2-040439-20060320-C-1.50
OptiX OSN 7500
Commissioning Guide                                           1 Preparations for Equipment Commissioning
1.2 Engineering Information
                Engineering information includes:
                     Networking diagram
                     IP address allocation diagram
                     Board layout of each NE
                     Fibre and cable connection table
                     Timeslot allocation diagram
                     Board level protection information
                     Clock tracing diagram
                     Orderwire diagram
T2-040439-20060320-C-1.50          Huawei Technologies Proprietary                                   1-3
                                                                                                                                                                                                             OptiX OSN 7500
1 Preparations for Equipment Commissioning                                                                                                                                                                Commissioning Guide
1.3 Connection Points Position
                                                                 EU08          OU08            MU04           TSB8          D34S            D75S            ETF8         EFF8        ETS8
                                                           5             4                13                          6            14                  12          15           12
                                                                                                                Interface board
                                                                        19 20 21 22 23               24 25      26   27 28 29 30 31                32 33        34 35 36 37 38
                                                                                                                                                                                                   GXCS
                        GSCC                   EOW                                                                                                                                                                         AUX
                                20                                                                                                                                                                             29
                                      21                                                                                                                                                                       30
                                22
                                      23                                                                                                                                                                              31
                                                                                                                                                                                                               32
                                24
                                                                                                                                                                                                                      33         PIU
                   16                 25                                                                                                                                                                       34
                                                                                                                                                                                                                      35
                   17                                                                                                                                                                                          36
                                26                                                                                                                                                                                                     18
                                                                                                                                                                                                               37                      19
                                      27
                                28
                                                                        1      2   3       4    5     6   7     8      9       10       11 12 13 14                15 16 17 18
                                                                                                                      Processing board
                               SL64    SL16          SL4       SLH1     SLT1       SEP1        SL1        PQ1        PL3A     SPQ4          LWX         MR2A       BPA     EGT2      EFS0   EGS2    EMR0       ADL4
                                1          2         3                   4            5         4                     6                 7          8        9       10      11               11    11     12    3
                  Figure 1-1 Connection points position of OptiX OSN 7500
1-4                                                                   Huawei Technologies Proprietary                                                                                       T2-040439-20060320-C-1.50
OptiX OSN 7500
Commissioning Guide                                              1 Preparations for Equipment Commissioning
                Table 1-3 Numbering and functions referred to the connection points
Access Point    Position                      Function Description                      Connection Type
Number (Note)
      1         T2SL64                        Optical stm-64 connections                LC
      2         N1SL16, N2SL16                Optical stm-16 connections                LC
      3         N1SL4, N2SL4, ADL4            Optical stm-4 connections                 LC
      4         N1SL1, N2SL1, N1SLT1,         Optical stm-1 connections                 LC
                N1OU08, N2OU08
      5         N1SEP1                        140 Mbit/s and STM-1 Electrical           SMB
                                              Connections
      6         N1PL3A, N1D34S                34 and 45 Mbit/s Electrical               SMB
                                              Connections
      7         N1LWX                         10 Mbit/s to 2.5 Mbit/s Optical           LC
                                              Connection at WDM side
      8         N1LWX                         10 Mbit/s to 2.5 Mbit/s Optical           LC
                                              Connection at client side
      9         N1MR2A                        Adding/Dropping and Multiplexing          LC
                                              Any Adjacent Two Channels
                                              Connections
      10        N1BPA                         Optical booster amplifier connections     LC
      11        N1EGT2, N2EGS2,               Optical 1000Base-SX and                   LC
                N2EMR0                        1000Base-LX Connections
      12        N1EFT8, N1EFS4,               Fast Ethernet access connections          RJ-45
                N1ETS8, N2EMR0
      13        N1MU04                        140 Mbit/s and STM-1 Electrical           SMB
                                              Connections (access unit)
      14        N1D75S                        2 Mbit/s Electrical Connections           2mmHM (75
                                                                                        ohm)
      15        N1EFF8                        Optical fast Ethernet access              LC
                                              connections
      16        N2GSCC                        Reset button                              Button
      17        N2GSCC                        Alarm cut switch                          Button
      18        T1PIU                         50 w power output connections             Common
                                                                                        socket–4 pin
      19        T1PIU                         -48 v power access connections            DB3
      20        T1EOW                         75-ohm clock connections 1                SMB
      21        T1EOW                         120-ohm clock connection 2                RJ-45
T2-040439-20060320-C-1.50           Huawei Technologies Proprietary                                     1-5
                                                                                                        OptiX OSN 7500
1 Preparations for Equipment Commissioning                                                           Commissioning Guide
Access Point      Position                            Function Description                              Connection Type
Number (Note)
      22          T1AUX                               Extended subrack connection                       RJ-45
      23          T1EOW                               Orderwire connection                              RJ-45
      24          T1EOW                               Outgoing subnet orderwire                         RJ-45
                                                      connections
      25          T1EOW                               OAM connection                                    RJ-45
      26          T1EOW                               Serial signal connections                         RJ-45
      27          T1EOW                               COM commissioning Connection                      RJ-45
      28          T1EOW                               T2000 connection                                  RJ-45
      29          T1AUX                               75-ohm clock connections 3                        SMB
      30          T1AUX                               120-ohm clock connection 4                        RJ-45
      31          T1AUX                               F&f Connection                                    RJ-45
      32          T1AUX                               F1 connection                                     RJ-45
      33          T1AUX                               Cabinet alarm indicator output                    RJ-45
                                                      connection
      34          T1AUX                               Cabinet alarm indicator input                     RJ-45
                                                      concatenation connection
      35          T1AUX                               Alarm concatenation connection                    RJ-45
      36          T1AUX                               Alarm output connection                           RJ-45
      37          T1AUX                               Alarm input connection                            RJ-45
                 Note: The number in the first column is corresponding to the number in the ring in Figure 1-1.
1.4 External Check
                  Confirm the following items in advance.
                      The hardware installation check is complete.
                      The T2000 is ready.
                      The T2000-local craft terminal (T2000-LCT) is ready in the laptop.
                      All equipment on each NE has active and standby power supplies. Check
                       whether alarms need to be output.
                      The interface impedance (75 ohms or 120 ohms) of the DDF on each NE is the
                       same as that of tributary boards and tributary interface boards.
                      Clock protection is provided. The setting of the clock board is correct. To
                       achieve clock protection switching, it is required to provide synchronisation
1-6                                       Huawei Technologies Proprietary                    T2-040439-20060320-C-1.50
OptiX OSN 7500
Commissioning Guide                                            1 Preparations for Equipment Commissioning
                      state message bit (SSMB) in the 2 Mbit/s clock signal and the location of that
                      message.
1.5 Requirements for Commissioning Engineers
                Before using this manual, commissioning engineers should have received training
                on optical equipment commissioning and be skillful at using various test tools. The
                requirements are as follows.
                     Be familiar with the fundamentals of SDH, PDH, Ethernet, and ATM.
                     Be familiar with the equipment.
                     Be skillful at using the T2000 for service configuration.
                     Be skillful at using the LCT for service configuration.
                     Be skillful at using test tools (for SDH, PDH, Ethernet, and ATM).
T2-040439-20060320-C-1.50           Huawei Technologies Proprietary                                   1-7
                                                                                             OptiX OSN 7500
1 Preparations for Equipment Commissioning                                                Commissioning Guide
1.6 Commissioning Items
                  Table 1-4 lists the testing items.
                  Table 1-4 Testing items
                   Item                 Sub-item
                   NE                   Checking hardware
                   commissioning
                                        Testing and powering on cabinet
                                        Testing subrack functions
                                        Accessing the equipment through the NM
                                        Testing the RESET button
                                        Testing the centralised alarm processing system
                                        Testing the software version
                                        Configuring service for testing
                                        Testing optical or electrical interface indexes
                                        Testing the electrical interfaces connection
                                        Testing the fibre jumper connection
                                        Testing the TPS of electrical interface
                                        Testing the active/standby board switching
                                        Testing bit errors on an NE
                                        Testing the intra-station ECC
                                        Backing up the NE database
                                        Testing NE restarting after power failure
                                        End of commissioning
1-8                                   Huawei Technologies Proprietary             T2-040439-20060320-C-1.50
OptiX OSN 7500
Commissioning Guide                                           1 Preparations for Equipment Commissioning
                 Item             Sub-item
                 Network          Testing network-wide fibre connection
                 commissioning
                                  Testing ECC routing
                                  Checking the network-wide software version
                                  Testing service channel availability
                                  Testing Ethernet services
                                  Testing self-healing protection switching
                                  Testing clock protection switching
                                  Testing orderwire
                                  Testing network-wide BER
                                  Other tests
                                  Configuring the services
                                  T2000 function verification
T2-040439-20060320-C-1.50        Huawei Technologies Proprietary                                     1-9