0% found this document useful (0 votes)
727 views1 page

Retaining Wall Drawing

This document contains engineering drawings showing the design details of a retaining wall. The cross section diagram shows the wall will have horizontal rebar reinforcement placed at various depths running every 200mm or 150mm. The longitudinal section shows vertical rebar reinforcement running every 200mm or 250mm. Notes indicate the dimensions are in meters and rebar sizes are 12mm and 10mm.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
727 views1 page

Retaining Wall Drawing

This document contains engineering drawings showing the design details of a retaining wall. The cross section diagram shows the wall will have horizontal rebar reinforcement placed at various depths running every 200mm or 150mm. The longitudinal section shows vertical rebar reinforcement running every 200mm or 250mm. Notes indicate the dimensions are in meters and rebar sizes are 12mm and 10mm.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

12 mm @ 200mm c/c

BACKFILL

12 mm @ 200mm c/c
10 mm @ 200mm c/c
10 mm @ 200mm c/c

12 mm @ 150mm c/c
GL
12 mm @ 150mm c/c
10 mm @ 150mm c/c

12 mm @ 250mm c/c
12 mm @ 250mm c/c

12 mm @ 200mm c/c
12 mm @ 200mm c/c
12 mm @ 250mm c/c

CROSS SECTION LONGITUDINAL SECTION

CLIENT: CONTRACTOR: LEGEND: DESIGN CONSULTANT:


NOTE:
1. ALL DIMENSIONS ARE IN METERS AND SECTION SIZES ARE IN MM.
TITLE: Retaining wall
2. ALL OUTER SECTION OF TRUSS ARE OF 40mmX40mmX2.6mm. AND INNER SECTION OF -
32mmX32mmX3.2mm.. Aatvik Consultancy
Rev. By Approved Date Description
MPUDC & Infrastructure Rev:
Date :

Drawn Designed Checked SUBMITTED APPROVED IC Team Leader Scale :


Hor. :
Ver.: