JT Pressure Switches
JT Pressure Switches
 J: Semicon-
                                                      35: 508 (3.5)
 ductor Type       T: Threaded
                                         02          100: 1450 (10)          10
   Pressure         Connection
                                                     350: 5082 (35)
    Switch
Design numbers are subject to change, but installat ion dimensions remain as
shown for design numbers 10 through 19
Ratings
Description                              Model No.           JT-02-35-10               JT-02-100-10             Jt-02-350-10
Max. Operating Pressure PSI (MPa) 1450 (10) 1450 (10) 5082 (35)
Proof Pressure PSI (MPa) 2904 (20) 2904 (20) 7623 (52.5)
Pressure Setting Range PSI (MPa) 14.5-508 (0.1-3.5) 145-1450 (1-10) 508-5082 (3.5-35)
Pressure Setting (ON Pressure Setting) Single Adjustment ON Trimmer Setting (Variable Res istor)*
Mass                                                                                   6 oz (175 g)
*    Trimmer Rotation Angle 0° to 230°
** IP54 Indicates the protection form and protection grade of the housing structure in conformity with the IEC529 (International
Electrotechnical Commission)
                                                                                                                        Page 2
                JT-02-*-10             Semiconductor Type    Pressure Switches
Hydraulic Fluids                              Care in Application
• Types Of Hydraulic Fluid                    Voltage-proof test should not be carried out
Petroleum base oil                            as semiconductor has been used
Phosphate ester type fluids
Polyor ester type fluids                      •   Recommended Viscosity and Oil
Water glycol type fluids                          Temperatures
Water in oil emulsion type fluids             Viscosity ranging between 15 and 400 cSt
                                              (mm2/s)
                                              Oil Temperature between -80° to +158° F
                                              (-20° to +70° C)
                                              Use Hydraulic fluids which satisfy the
                                              recommended viscosity and oil temperature
                                              given above.
Mounting Dimensions
Adjustment
1. Before starting, turn the ON and DIFF trimmers
   fully clockwise (Trimmer Rotation Angle: 0° -
   230°).
2. Turn on the power.
3. <ON pressure setting>
   Apply required pressure to the switch. Turn ON
   trimmer slowly counterclockwise and stop it
   when LED indicator lights, ON setting obtained.
4. <Differential pressure setting>
   Gradually reduce pressure to obtain the
   required OFF pressure. Then, turn DIFF
   trimmer counterclockwise slowly and stop it
   when LED indicator goes off. The OFF setting
   is now obtained.
5. Make sure if “ON” or “OFF” setting is correct by
   working of LED indicator when applying or
   reducing pressure repeatedly several times.
                                                                                   Page 3
Application Examples of Electrical Circuit
•   Output of Semiconductor Type Pres-    •   Direct Relay Drive
    sure Switch (Internal Circuit)               1. Use relay operable at 100 mA or
                                                     lower.
                                                 2. Connect surge voltage absorption
                                                     diode (D) in parallel with the relay
                                                     coil.
                                                 3. Connect positive diode (D) be-
                                                     tween the white and green wires.
                                                                                  Page 4
Application Examples
•   For hydraulic circuit pressure increase/   •   For fatigue tester or other instrument
    decrease monitoring or alarming.               test counting.
Page 5