Column Design Calculations
Column Design Calculations
Definitions Of Terms:
   All forces in units kN and m
   All reinforcement details like area, spacing in mm
   Neutral axis angle for resultant design moment is with respect to local major axis.
Code References:
ACI 318M-2011
Sr.No   Element                                                   Clause / table
          Minimum area of longitudinal reinforcement
1                                                      :          21.6.3
        for column
        Maximum area of longitudinal
2                                                      :          21.6.3
        reinforcement for column
        Minimum longitudinal and transverse
3                                                      :          21.9.2.1
        reinforcement for wall
4       Minimum diameter of transverse ties            :          7.10.5
5       Minimum spacing of transverse ties             :          7.10.5
        Maximum spacing of longitudinal and
6                                                      :          21.9.2.1
        transverse reinforcement for wall
7       Applicability of boundary element              :          21.9.6
        Area and spacing of special confining
8
                                                       :          21.6.4
        reinforcement
9       Slenderness Moments                            :          10.10
        Shear Strength provided by concrete for
10
                                                       :          11.2
        column
11      Design of shear for non-ductile wall           :          11.9
12      Design of shear for ductile wall               :          21.9.4
13      Minimum Flexural Strength of Columns           :          21.6.2.2
14      Shear Check at Column Joint                    :          21.7.4.1
15      Shear Strength of Column                       :          21.3.3 & 21.5.4
Sway Calculation (Stability Index)
For Global-X Direction
  Level     Load       Story      Gravity      Relative     Story Shear    Stability        Sway
            Name     Height (m)   Load P    Displacements      (kN)         Index         Condition
                                   (kN)         (mm)
                                                                          B x C / (A x
                           A         B             C            D
                                                                              D)
0m to 1m   LOAD 1:         1      902.963       0.434        145.003         0.003        Non Sway
               EX
1m to 4m   LOAD 1:         3      804.531       3.649         141.01         0.007        Non Sway
             EX
4m to 7m   LOAD 1:         3      206.109       3.137         55.582         0.004        Non Sway
             EX
General Data
Column No.                           :       C1
Level                                :       0m To 1m
Design Code                          =       ACI 318M - 2011
Grade Of Concrete                    =       C21                                         N/sqmm
Grade Of Steel                       =       Fy230                                       N/sqmm
Consider Ductile                     =       Yes
Type of Frame                        =       Special
Column B                             =       400                                         mm
Column D                             =       400                                         mm
Clear Cover                          =       40                                          mm
Clear Floor Height @ lux             =       700                                         mm
Clear Floor Height @ luy               =   700                                  mm
No Of Floors                           =   1
No Of Columns In Group                 =   1
Load Data
Analysis Reference No.                 =   1
Critical Analysis Load Combination :       24
Load Combination                       =   [20] : 0.7 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location                      =   Bottom Joint
Put                                    =   55.67                               kN
Muxt                                   =   -4.54                               kNm
Muyt                                   =   22.13                               kNm
Vuxt                                   =   -25.01                              kN
Vuyt                                   =   -0.24                               kN
Pub                                    =   58.31                               kN
Muxb                                   =   -4.78                               kNm
Muyb                                   =   47.13                               kNm
Vuxb                                   =   -25.01                              kN
Vuyb                                   =   -0.24                               kN
Effective Length Calculation
Calculation Along Major Axis Of Column
    Joint        Column             Beam Sizes                   Beam Stiffness         Beta
                Stiffness      Beam 1       Beam 2             Beam 1     Beam 2
                                 (Length x      (Length x
                               Width x Depth) Width x Depth)
                   N-M              mm             mm           N-M        N-M
    Bottom        195.523        No Beam        No Beam           -         -             1
                                3600 x 200 x
     Top          195.523                       No Beam        11.456        -          22.756
                                    300
Along B
          Q                           =        0.003
                                      0.003< 0.05, Column shall be designed as non-sway
                                      frame (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                         =      0.87
r                                         =      115.47                            mm
Kluy /r                                   =      5.27
M1                                    =        -4.54                                 kNm
M2                                    =        -4.78                                 kNm
34 - 12 x (M1/M2)                     =         22.6
                                      5.27 < 22.6, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =        0.87
r                                     =        115.47                                mm
Klux /r                               =        5.27
M1                                    =        22.13                                 kNm
M2                                    =        47.13                                 kNm
34 - 12 x (M1/M2)                     =         28.37
                                      5.27 < 28.37, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                   MAX((Left,Top + Right,Bot),
 Mnty                                   =
                                                   (Right,Top + Left,Bot))
                                        =          23.21                                     kNm
 Design Of Shear
 Design for shear along D
 Shear from Moment Capacity:
 Pu                                     =          58.31                                     kN
 Luy                                    =          700                                       mm
 Mnty                                   =          78.94                                     kNm
 Mnby                                   =          78.94                                     kNm
 Vuy1                                   =          225.56                                    kN
 Shear from Beam Capacity at Joint:
 Luy                                    =          700                                       mm
 Mnty                                   =          23.21                                     KN-m
 Mnby                                   =          0                                         KN-m
 Vuy2                                   =          33.16                                     KN
 Critical Analysis Load Combination :              19
Critical Load Combination            =       [15] : 1.4 (LOAD 3: DL) +1.25 (LOAD kN
                                             1: EX)
Nu                                   =       123.43                              kN
Muy                                  =       38.83                              kNm
Vuy                                  =       18.1974                            kN
Design Shear                         =       max(Vuy, Vuy1, Vuy2)
                                     =       225.56                             kN
λ                                    =       1
φ                                    =       0.65
deff                                 =       352                                mm
ρw                                   =       0.005
mm                                   =       19.58                              kNm
Vcy Permissible                      =       127.84                             kN
Vuy                                  >       Vcy Permissible
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                              mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                               mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                             mm
48 x diameter of links                  =        480                             mm
Provided spacing                        =        175                             mm
General Data
Column No.                             :        C1
Level                                  :        1m To 4m
Design Code                            =        ACI 318M - 2011
Grade Of Concrete                      =        C21                                          N/sqmm
Grade Of Steel                         =        Fy230                                        N/sqmm
Consider Ductile                       =        Yes
Type of Frame                          =        Special
Column B                               =        400                                          mm
Column D                               =        400                                          mm
Clear Cover                            =        40                                           mm
Clear Floor Height @ lux               =        2600                                         mm
Clear Floor Height @ luy               =        2600                                         mm
No Of Floors                           =        1
No Of Columns In Group                 =        1
Load Data
Analysis Reference No.                 =        2
Critical Analysis Load Combination :            22
Load Combination                       =        [18] : 1.4 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location                      =         Top Joint
Put                                    =         123.88                            kN
Muxt                                   =         5.22                              kNm
Muyt                                   =         36.11                             kNm
Vuxt                                   =         23.59                             kN
Vuyt                                   =         -0.96                             kN
Pub                                    =         139.72                            kN
Muxb                                   =         2.34                              kNm
Muyb                                   =         -34.63                            kNm
Vuxb                                   =         23.59                             kN
Vuyb                                   =         -0.96                             kN
Along B
          Q                          =         0.006
                                     0.006< 0.05, Column shall be designed as non-sway frame
                                     (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =        1
r                                     =        115.47                                 mm
Kluy /r                               =        22.52
M1                                    =        2.34                                   kNm
M2                                    =        5.22                                   kNm
34 - 12 x (M1/M2)                     =         28.61
                                      22.52 < 28.61, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =        1
r                                     =        115.47                                 mm
Klux /r                               =        22.52
M1                                    =        -34.63                                 kNm
M2                                    =        36.11                                  kNm
34 - 12 x (M1/M2)                     =         45.51
                                      22.52 < 45.51, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                     MAX((Left,Top + Right,Bot),
 Mnty                                     =
                                                     (Right,Top + Left,Bot))
                                          =          66.38                                     kNm
  Beams at Level: Bottom Joint
Beam Beam Torsion Moment Capacity Beam at Moment Capacity Beam at                  Resultant Moment
 Size angle moment             Top               Bottom
       w.r.t.
      column
        Ly
                      Mu Ast req Ast pro Mu     Mu Ast req Ast pro Mu Top Top Bot @ Bot @
                                         cap                        cap @ D @ B       D     B
(mm) (deg)    (kNm) (kNm) (sqmm) (sqmm) (kNm) (kNm) (sqmm) (sqmm) (kNm) (kNm) (kNm) (kNm) (kNm)
200 x
        0     -0.1     7.72 239.09 402.12 23.21     4.6 239.09 402.12 23.21 23.21           0     23.21     0
 300
200 x   270   -0.16    8.6 239.09 402.12 23.21     4.41 239.09 402.12 23.21       0       23.21     0     23.21
300
 Moment Along B:
                                                  MAX((Left,Top + Right,Bot),
 Mnby                                   =
                                                  (Right,Top + Left,Bot))
                                        =         23.21                                     kNm
 Design Of Shear
 Design for shear along D
 Shear from Moment Capacity:
 Pu                                     =         123.88                                    kN
 Luy                                    =         2600                                      mm
 Mnty                                   =         91.73                                     kNm
 Mnby                                   =         91.73                                     kNm
 Vuy1                                   =         70.56                                     kN
 Shear from Beam Capacity at Joint:
 Luy                                    =         2600                                      mm
 Mnty                                   =         66.38                                     KN-m
 Mnby                                   =         23.21                                     KN-m
 Vuy2                                   =         34.46                                     KN
 Critical Analysis Load Combination :             22
 Critical Load Combination              =         [18] : 1.4 (LOAD 3: DL) -1.25 (LOAD kN
                                                  2: EZ)
Nu                                   =           139.72                                kN
Muy                                  =           2.34                                  kNm
Vuy                                  =           -0.9576                               kN
Design Shear                         =           max(Vuy, Vuy1, Vuy2)
                                     =           70.56                                 kN
λ                                    =           1
φ                                    =           0.65
deff                                 =           352                                   mm
ρw                                   =           0.005
mm                                   =           19.45                                 kNm
Vcy Permissible                      =           209.47                                kN
Vuy                                  <           Vcy Permissible
Link For Shear Design Along D are not required
Load Data
Analysis Reference No.               =   3
Critical Analysis Load Combination   :   22
Load Combination                     =   [18] : 1.4 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location                    =   Bottom Joint
Put                                  =   26.1                                 kN
Muxt                                 =   5.99                                 kNm
Muyt                                 =   19.44                                kNm
Vuxt                                 =   13.2                                 kN
Vuyt                                 =   -4.73                                kN
Pub                                  =   41.94                                kN
Muxb                                 =   -8.19                                kNm
Muyb                                 =   -20.16                               kNm
Vuxb                                 =   13.2                                 kN
Vuyb                                 =   -4.73                                kN
Effective Length Calculation
Calculation Along Major Axis Of Column
    Joint        Column             Beam Sizes                   Beam Stiffness      Beta
                Stiffness      Beam 1       Beam 2             Beam 1     Beam 2
                                 (Length x      (Length x
                               Width x Depth) Width x Depth)
                    N-M             mm             mm           N-M        N-M
                                3600 x 250 x
   Bottom          65.174                       No Beam        33.945        -       3.844
                                    400
                                   3600 x 200 x
     Top           65.174                         No Beam      11.456            -   5.689
                                        300
Along B
          Q                          =         0.003
                                     0.003< 0.05, Column shall be designed as non-sway frame
                                     (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =        1
r                                     =        115.47                                mm
Kluy /r                               =        23.38
M1                                    =        5.99                                  kNm
M2                                    =        -8.19                                 kNm
34 - 12 x (M1/M2)                     =         42.79
                                      23.38 < 42.79, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =        1
r                                     =        115.47                                mm
Klux /r                               =        23.38
M1                                    =        19.44                                 kNm
M2                                    =        -20.16                                kNm
34 - 12 x (M1/M2)                     =         45.57
                                      23.38 < 45.57, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Final Critical Design Forces
 Critical Case - Axial Load & BiAxial Bending
 Pu                                      =           41.94                                       kN
 Mux                                     =           -8.19                                       kNm
 Muy                                     =           -20.16                                      kNm
                      Mu Ast req Ast pro Mu     Mu Ast req Ast pro Mu Top Top Bot @ Bot @
                                         cap                        cap @ D @ B       D     B
(mm) (deg)    (kNm) (kNm) (sqmm) (sqmm) (kNm) (kNm) (sqmm) (sqmm) (kNm) (kNm) (kNm) (kNm) (kNm)
200 x
       0         -0.17   13.45 304.35 402.12 23.21    3.08 239.09 402.12 23.21 23.21         0        23.21    0
 300
200 x   270      -0.2    16.34 329.82 402.12 23.21    1.76 239.09 402.12 23.21      0     23.21        0      23.21
300
 Moment Along B:
                                                     MAX((Left,Top + Right,Bot),
 Mnty                                    =
                                                     (Right,Top + Left,Bot))
                                         =           23.21                                       kNm
 Beams at Level: Bottom Joint
Beam Beam Torsion Moment Capacity Beam at Moment Capacity Beam at        Resultant Moment
 Size angle moment            Top                    Bottom
       w.r.t.
      column
        Ly
                     Mu Ast req Ast pro Mu   Mu Ast req Ast pro Mu Top Top Bot @ Bot @
                                        cap                      cap @ D @ B         D    B
(mm) (deg) (kNm) (kNm) (sqmm) (sqmm) (kNm) (kNm) (sqmm) (sqmm) (kNm) (kNm) (kNm) (kNm) (kNm)
250 x
         0    -1.96 40.36 582 603.18 49.13 10.91 418.41 603.18 49.13 49.13   0     49.13 0
 400
250 x   270   -0.6   47.63 692.81 829.38 66.38    8.14 418.41 603.18 49.13      0    66.38     0   49.13
400
Design Of Shear
Design for shear along D
Shear from Moment Capacity:
Pu                                   =           41.94                              kN
Luy                                  =           2700                               mm
Mnty                                 =           76.82                              kNm
Mnby                                 =           76.82                              kNm
Vuy1                                 =           56.9                               kN
Shear from Beam Capacity at Joint:
Luy                                  =           2700                               mm
Mnty                                 =           23.21                              KN-m
Mnby                                 =           66.38                              KN-m
Vuy2                                 =           33.18                              KN
Critical Analysis Load Combination   :           23
Critical Load Combination            =           [19] : 0.7 (LOAD 3: DL) +1.25 (LOAD kN
                                                 1: EX)
Nu                                   =           8.1                                 kN
Muy                                  =           3.94                               kNm
Vuy                                  =           1.45                               kN
Design Shear                         =           max(Vuy, Vuy1, Vuy2)
                                     =           56.9                               kN
λ                                    =           1
φ                                    =           0.65
deff                                 =           352                                mm
ρw                                   =           0.005
mm                                   =           2.68                               kNm
Vcy Permissible                      =           164.38                             kN
Vuy                                  <           Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                                   mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                                    mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                                  mm
48 x diameter of links                  =        480                                  mm
Provided spacing                        =        200                                  mm
General Data
Column No.                             :         C2
Level                                  :         0m To 1m
Design Code                            =         ACI 318M - 2011
Grade Of Concrete                      =         C21                                  N/sqmm
Grade Of Steel                         =         Fy230                                N/sqmm
Consider Ductile                       =         Yes
Type of Frame                          =         Special
Column B                               =         400                                  mm
Column D                               =         400                                  mm
Clear Cover                            =         40                                   mm
Clear Floor Height @ lux               =         700                                  mm
Clear Floor Height @ luy               =         700                                  mm
No Of Floors                           =         1
No Of Columns In Group                 =         1
Load Data
Analysis Reference No.                 =         4
Critical Analysis Load Combination :             24
Load Combination                       =         [20] : 0.7 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location                      =         Bottom Joint
Put                                       =      80.12                              kN
Muxt                                      =      -3.48                              kNm
Muyt                                      =      20.8                               kNm
Vuxt                                      =      -20.68                             kN
Vuyt                                      =      -1.72                              kN
Pub                                       =      82.76                              kN
Muxb                                      =      -5.2                               kNm
Muyb                                      =      41.47                              kNm
Vuxb                                      =      -20.68                             kN
Vuyb                                      =      -1.72                              kN
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =         0.87
r                                     =         115.47                               mm
Kluy /r                               =         5.27
M1                                    =         -3.48                                kNm
M2                                    =         -5.2                                 kNm
34 - 12 x (M1/M2)                     =         25.96
                                      5.27 < 25.96, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =         0.87
r                                     =         115.47                               mm
Klux /r                               =         5.27
M1                                    =         20.8                                 kNm
M2                                    =         41.47                                kNm
34 - 12 x (M1/M2)                     =         27.98
                                      5.27 < 27.98, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                     MAX((Left,Top + Right,Bot),
 Mnty                                    =
                                                     (Right,Top + Left,Bot))
                                         =           23.21                                       kNm
Design Of Shear
Design Of Links
Links in the zone where special confining links are not required
Normal Links
    Diameter of link                         =
                                                                                                         >
                                                                                                         =
    Criterion for spacing of normal links
    Min. Longitudinal Bar dia X 16           =
10                                          mm
Max. longitudinal bar dia / 4
4                                           mm
256                                         mm
  48 x diameter of links                      =      480                                  mm
    Provided spacing                             =   150                                  mm
                                       Required                                     Provided
                       Normal Design Shear Design         Ductile Design   Normal Zone    Ductile Zone
          Link Dia.         10            ---                   10              10            10
           Spacing         150            ---                   75             150            75
General Data
Column No.                            :          C2
Level                                 :          1m To 4m
Design Code                           =          ACI 318M - 2011
Grade Of Concrete                     =          C21                                   N/sqmm
Grade Of Steel                        =          Fy230                                 N/sqmm
Consider Ductile                      =          Yes
Type of Frame                         =          Special
Column B                              =          400                                   mm
Column D                              =          400                                   mm
Clear Cover                           =          40                                    mm
Clear Floor Height @ lux              =          2600                                  mm
Clear Floor Height @ luy              =          2600                                  mm
No Of Floors                          =          1
No Of Columns In Group                =          1
Load Data
= Non Sway
= 1
Along B
          Q                          =         0.006
                                     0.006< 0.05, Column shall be designed as non-sway frame
                                     (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =        1
r                                     =        115.47                                mm
Kluy /r                               =        22.52
M1                                    =        -8.69                                 kNm
M2                                    =        8.91                                  kNm
34 - 12 x (M1/M2)                     =         45.71
                                      22.52 < 45.71, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =        1
r                                     =        115.47                                mm
Klux /r                               =        22.52
M1                                    =        -37.07                                kNm
M2                                    =        52.21                                 kNm
34 - 12 x (M1/M2)                     =         42.52
                                      22.52 < 42.52, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Final Critical Design Forces
 Critical Case - Axial Load & BiAxial Bending
 Pu                                     =           191.33                                    kN
 Mux                                    =           -8.69                                     kNm
 Muy                                    =           52.21                                     kNm
 Moment Along B:
                                                     MAX((Left,Top + Right,Bot),
 Mnty                                     =
                                                     (Right,Top + Left,Bot))
                                          =          79.34                                       kNm
 Moment Along B:
                                                     MAX((Left,Top + Right,Bot),
 Mnby                                     =
                                                     (Right,Top + Left,Bot))
                                          =          23.21                                       kNm
Design Of Shear
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                                     mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                                      mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                                    mm
48 x diameter of links                  =        480                                    mm
Provided spacing                        =        200                                    mm
General Data
Column No.                           :          C2
Level                                :          4m To 7m
Design Code                          =          ACI 318M - 2011
Grade Of Concrete                    =          C21                                  N/sqmm
Grade Of Steel                       =          Fy230                                N/sqmm
Consider Ductile                     =          Yes
Type of Frame                        =          Special
Column B                             =          400                                  mm
Column D                             =          400                                  mm
Clear Cover                          =          40                                   mm
Clear Floor Height @ lux             =          2700                                 mm
Clear Floor Height @ luy             =          2700                                 mm
No Of Floors                         =          1
No Of Columns In Group                 =         1
Load Data
Analysis Reference No.                 =         6
Critical Analysis Load Combination :             22
Load Combination                       =         [18] : 1.4 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location                      =         Bottom Joint
Put                                    =         39.21                                 kN
Muxt                                   =         -7.61                                 kNm
Muyt                                   =         26.34                                 kNm
Vuxt                                   =         21.58                                 kN
Vuyt                                   =         5.59                                  kN
Pub                                    =         55.05                                 kN
Muxb                                    =        9.15                                  kNm
Muyb                                   =         -38.37                                kNm
Vuxb                                   =         21.58                                 kN
Vuyb                                   =         5.59                                  kN
                            =   0.004
                                      0.004< 0.05, Column shall be designed as non-sway
                                      frame (Braced)
Along B
          Q                          =         0.003
                                      0.003< 0.05, Column shall be designed as non-sway
                                      frame (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =         1
r                                     =         115.47                               mm
Kluy /r                               =         23.38
M1                                    =         -7.61                                kNm
M2                                    =         9.15                                 kNm
34 - 12 x (M1/M2)                     =         43.97
                                      23.38 < 43.97, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =         1
r                                     =         115.47                               mm
Klux /r                               =         23.38
M1                                    =         26.34                                kNm
M2                                    =         -38.37                               kNm
34 - 12 x (M1/M2)                     =         42.24
                                      23.38 < 42.24, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                     MAX((Left,Top + Right,Bot),
 Mnty                                    =
                                                     (Right,Top + Left,Bot))
                                         =           35.16                                       kNm
 Beams at Level: Bottom Joint
Beam Beam Torsion Moment Capacity Beam at         Moment Capacity Beam at           Resultant Moment
 Size angle moment         Top                           Bottom
       w.r.t.
      column
        Ly
                   Mu Ast req Ast pro Mu     Mu Ast req Ast pro Mu Top Top Bot @ Bot @
                                       cap                       cap @ D @ B        D    B
(mm) (deg) (kNm) (kNm) (sqmm) (sqmm) (kNm) (kNm) (sqmm) (sqmm) (kNm) (kNm) (kNm) (kNm) (kNm)
250 x
       0    -0.07 37.47 538.48 603.18 49.13 21.54 418.41 603.18 49.13 49.13  0    49.13 0
 400
250 x   180   -1.96   42.4 612.84 829.38 66.38    8.37 418.41 603.18 49.13 66.38         0        49.13    0
400
250 x   270   -0.63   63.81 946.7 1005.3 79.34     0     418.41 603.18 49.13    0     79.34        0      49.13
 400
 Moment Along B:
                                                 MAX((Left,Top + Right,Bot),
 Mnby                                 =
                                                 (Right,Top + Left,Bot))
                                      =          79.34                                       kNm
 Design Of Shear
 Design for shear along D
 Shear from Moment Capacity:
 Pu                                   =          55.05                                       kN
 Luy                                  =          2700                                        mm
 Mnty                                 =          78.85                                       kNm
 Mnby                                 =          78.85                                       kNm
 Vuy1                                 =          58.41                                       kN
 Shear from Beam Capacity at Joint:
 Luy                                  =          2700                                        mm
 Mnty                                 =          35.16                                       KN-m
 Mnby                                 =          79.34                                       KN-m
Vuy2                                       =     42.41                               KN
Critical Analysis Load Combination :             26
Critical Load Combination                  =     [22] : 0.7 (LOAD 3: DL) -1.25 (LOAD kN
                                                 2: EZ)
Nu                                         =     20.73                                kN
Muy                                        =     5.66                                kNm
Vuy                                        =     4.1054                              kN
Design Shear                               =     max(Vuy, Vuy1, Vuy2)
                                        =        59.97                               kN
λ                                      =         1
φ                                      =         0.65
deff                                   =         352                                 mm
ρw                                     =         0.005
mm                                     =         2.43                                kNm
Vcy Permissible                        =         148.12                              kN
Vuy                                    <         Vcy Permissible
Link For Shear Design Along D are not required
                                                 LL)
Nu                                     =         9.07                                kN
Mux                                    =         4.25                                kNm
Vux                                    =         5.8637                              kN
Design Shear                           =         max(Vux, Vux1, Vux2)
                                       =         58.41                               kN
λ                                      =         1
φ                                      =         0.65
deff                                   =         352                                 mm
ρw                                     =         0.005
mm                                     =         2.83                                kNm
Vcx Permissible                        =         161.51                              kN
Vux                                     <         Vcx Permissible
Link For Shear Design Along B are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                                   mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                                    mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                                  mm
48 x diameter of links                  =        480                                  mm
Provided spacing                        =        200                                  mm
General Data
Column No.                            :          C3
Level                                 :          0m To 1m
Design Code                           =          ACI 318M - 2011
Grade Of Concrete                     =          C21                                 N/sqmm
Grade Of Steel                        =          Fy230                               N/sqmm
Consider Ductile                      =          Yes
Type of Frame                         =          Special
Column B                              =          400                                 mm
Column D                              =          400                                 mm
Clear Cover                           =          40                                  mm
Clear Floor Height @ lux              =          700                                 mm
Clear Floor Height @ luy              =          700                                 mm
No Of Floors                          =          1
No Of Columns In Group                =          1
Load Data
= Non Sway
=            0.87
    alculation Along Minor Axis Of Column
        Joint        Column             Beam Sizes                  Beam Stiffness    Beta
                     Stiffness      Beam 1      Beam 2            Beam 1     Beam 2
                                    (Length x      (Length x
                                  Width x Depth) Width x Depth)
                       N-M             mm             mm           N-M        N-M
       Bottom         195.523       No Beam        No Beam           -         -        1
                                   4100 x 200 x
         Top          195.523                      No Beam        10.059        -     25.859
                                       300
    Sway Condition (as per Stability
                                          =         Non Sway
    Index)
    Effective Length Factor along Minor
                                          =         0.87
    axis
Check For Stability Index
Along D
          Q                          =         0.003
                                     0.003< 0.05, Column shall be designed as non-sway frame
                                     (Braced)
Along B
          Q                          =         0.003
                                     0.003< 0.05, Column shall be designed as non-sway frame
                                     (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =        0.87
r                                     =        115.47                                mm
Kluy /r                               =        5.27
M1                                    =        -19.29                                kNm
M2                                    =        -38.11                                kNm
34 - 12 x (M1/M2)                     =         27.93
                                      5.27 < 27.93, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =        0.87
r                                     =        115.47                                mm
Klux /r                               =        5.27
M1                                    =        -0.01                                 kNm
M2                                    =        2.33                                  kNm
34 - 12 x (M1/M2)                     =         34.04
                                      5.27 < 34.04, Column not slender along B
Calculation of Design Moment
                Direction                      Manalysis        Msldr or Mc       Mdesign-final
                                                   A                B                   C
Major Axis Mux (top)                            -19.29               -               -19.29
Major Axis Mux (bottom)                         -38.11               -               -38.11
Minor Axis Muy (top)                             -0.01               -                -0.01
Minor Axis Muy (bottom)                          2.33                -                 2.33
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                    MAX((Left,Top + Right,Bot),
 Mnty                                    =
                                                    (Right,Top + Left,Bot))
                                         =          23.21                                     kNm
Design Of Shear
Design for shear along D
Shear from Moment Capacity:
Pu                                     =   31.5                               kN
Luy                                    =   700                                mm
Mnty                                   =   75.2                               kNm
Mnby                                   =   75.2                               kNm
Vuy1                                   =   214.87                             kN
Shear from Beam Capacity at Joint:
Luy                                    =   700                                mm
Mnty                                   =   23.21                              KN-m
Mnby                                   =   0                                  KN-m
Vuy2                                   =   33.16                              KN
Critical Analysis Load Combination :       19
Critical Load Combination              =   [15] : 1.4 (LOAD 3: DL) +1.25 (LOAD kN
                                           1: EX)
Nu                                     =   167.73                              kN
Muy                                    =   38.36                              kNm
Vuy                                    =   16.5293                            kN
Design Shear                           =   max(Vuy, Vuy1, Vuy2)
                                       =   214.87                             kN
λ                                      =   1
φ                                      =   0.65
deff                                   =   352                                mm
ρw                                     =   0.005
mm                                     =   12.2                               kNm
Vcy Permissible                        =   126.96                             kN
Vuy                                    >   Vcy Permissible
Link For Shear Design Along D are required
Vs                                   =       Vu - Vcy
                                     =       87.91                              kN
Vcx Permissible                      =       0.5 x Vcx x 0.65
                                     =       41.26
Area of shear reinforcement required, =      1085.85                            mm^2/m
Asv-D
Diameter of column master links       =      10
Number of legs provided              =       4
Spacing of links prvd, Sv            =       175                                mm
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                              mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                               mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                             mm
48 x diameter of links                  =        480                             mm
Provided spacing                        =        175                             mm
General Data
Column No.                             :         C3
Level                                  :         1m To 4m
Design Code                            =         ACI 318M - 2011
Grade Of Concrete                      =         C21                                   N/sqmm
Grade Of Steel                         =         Fy230                                 N/sqmm
Consider Ductile                       =         Yes
Type of Frame                          =         Special
Column B                               =         400                                   mm
Column D                               =         400                                   mm
Clear Cover                            =         40                                    mm
Clear Floor Height @ lux               =         2600                                  mm
Clear Floor Height @ luy               =         2600                                  mm
No Of Floors                           =         1
No Of Columns In Group                 =         1
Load Data
Analysis Reference No.                 =         8
Critical Analysis Load Combination :             22
Load Combination                       =         [18] : 1.4 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location                      =         Top Joint
Put                                    =         129.99                               kN
Muxt                                   =         -9.17                                kNm
Muyt                                   =         40.65                                kNm
Vuxt                                   =         23.49                                kN
Vuyt                                   =         5.98                                 kN
Pub                                    =         145.83                               kN
Muxb                                   =         8.77                                 kNm
Muyb                                   =         -29.8                                kNm
Vuxb                                   =         23.49                                kN
Vuyb                                   =         5.98                                 kN
Effective Length Calculation
Calculation Along Major Axis Of Column
    Joint       Column              Beam Sizes                   Beam Stiffness          Beta
                Stiffness     Beam 1       Beam 2              Beam 1      Beam 2
                                (Length x      (Length x
                              Width x Depth) Width x Depth)
                    N-M            mm             mm            N-M         N-M
                               800 x 200 x    2600 x 200 x
    Bottom         65.174                                      51.554      15.863         3.87
                                   300            300
                               800 x 250 x    2600 x 250 x
     Top           65.174                                      152.753     47.001         0.652
                                   400            400
Sway Condition (as per Stability
                                       =         Non Sway
Index)
Effective Length Factor along Major
                                       =         0.83
Axis
Along B
          Q                           =        0.006
                                      0.006< 0.05, Column shall be designed as non-sway
                                      frame (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                         =      0.83
r                                         =      115.47                             mm
Kluy /r                                   =      18.69
M1                                    =        8.77                                  kNm
M2                                    =        -9.17                                 kNm
34 - 12 x (M1/M2)                     =         45.47
                                      18.69 < 45.47, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =        1
r                                     =        115.47                                mm
Klux /r                               =        22.52
M1                                    =        -29.8                                 kNm
M2                                    =        40.65                                 kNm
34 - 12 x (M1/M2)                     =         42.8
                                      22.52 < 42.8, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                  MAX((Left,Top + Right,Bot),
 Mnty                                 =
                                                  (Right,Top + Left,Bot))
                                      =           66.38                                       kNm
Moment Along B:
                                                 MAX((Left,Top + Right,Bot),
Mnby                                   =
                                                 (Right,Top + Left,Bot))
                                       =         23.21                                   kNm
Design Of Shear
Design Of Links
Links in the zone where special confining links are not required
Normal Links
    Diameter of link                         =
                                             >
                                             =
    Criterion for spacing of normal links
    Min. Longitudinal Bar dia X 16           =
    48 x diameter of links                   =
    Provided spacing                         =
256                                         mm
480                                         mm
200                                         mm
    96      mmB / 4                          =   100      mm
    So                                       =   191.67   mm
    Spacing                                  =   150      mm
    Provided Spacing                         =   75       mm
General Data
Column No.                           :           C3
Level                                :           4m To 7m
Design Code                          =           ACI 318M - 2011
Grade Of Concrete                    =           C21                                   N/sqmm
Grade Of Steel                       =           Fy230                                 N/sqmm
Consider Ductile                     =           Yes
Type of Frame                        =           Special
Column B                             =           400                                   mm
Column D                             =           400                                   mm
Clear Cover                          =           40                                    mm
Clear Floor Height @ lux             =           2700                                  mm
Clear Floor Height @ luy             =           2700                                  mm
No Of Floors                         =           1
No Of Columns In Group               =           1
Load Data
= Non Sway
= 0.74
    Along B
           Q                              =         0.003
                                          0.003< 0.05, Column shall be designed as non-sway frame
                                          (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                              =        0.74
r                              =        115.47                             mm
Kluy /r                        =        17.3
M1                             =        -6.72                              kNm
M2                             =        9.27                               kNm
34 - 12 x (M1/M2)              =         42.71
                               17.3 < 42.71, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                              =        1
r                              =        115.47                             mm
Klux /r                        =        23.38
M1                             =        22.53                              kNm
M2                             =        -28.45                             kNm
34 - 12 x (M1/M2)              =         43.5
                               23.38 < 43.5, Column not slender along B
 Moment Along B:
                                                  MAX((Left,Top + Right,Bot),
 Mnty                                  =
                                                  (Right,Top + Left,Bot))
                                       =          35.16                                     kNm
 Moment Along B:
                                                  MAX((Left,Top + Right,Bot),
 Mnby                                  =
                                                  (Right,Top + Left,Bot))
                                       =          66.38                                     kNm
 Design Of Shear
 Design for shear along D
 Shear from Moment Capacity:
 Pu                                    =          42.39                                     kN
 Luy                                   =          2700                                      mm
 Mnty                                  =          76.89                                     kNm
 Mnby                                  =          76.89                                     kNm
 Vuy1                                  =          56.96                                     kN
 Shear from Beam Capacity at Joint:
Luy                                  =           2700                                mm
Mnty                                 =           35.16                               KN-m
Mnby                                 =           66.38                               KN-m
Vuy2                                 =           37.6                                KN
Critical Analysis Load Combination   :           14
Critical Load Combination            =           [10] : 1.2 (LOAD 3: DL) +1.6 (LOAD 4: kN
                                                 LL)
Nu                                   =           21.07                                 kN
Muy                                  =           3.54                                kNm
Vuy                                  =           1.6505                              kN
Design Shear                         =           max(Vuy, Vuy1, Vuy2)
                                     =           56.96                               kN
λ                                    =           1
φ                                    =           0.65
deff                                 =           352                                 mm
ρw                                   =           0.005
mm                                   =           0.25                                kNm
Vcy Permissible                      =           171.43                              kN
Vuy                                  <           Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                              mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                               mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                             mm
48 x diameter of links                  =        480                             mm
Provided spacing                        =        200                             mm
General Data
Column No.                             :         C4
Level                                  :         0m To 1m
Design Code                            =         ACI 318M - 2011
Grade Of Concrete                      =         C21                                   N/sqmm
Grade Of Steel                         =         Fy230                                 N/sqmm
Consider Ductile                       =         Yes
Type of Frame                          =         Special
Column B                               =         400                                   mm
Column D                               =         400                                   mm
Clear Cover                            =         40                                    mm
Clear Floor Height @ lux               =         700                                   mm
Clear Floor Height @ luy               =         700                                   mm
No Of Floors                           =         1
No Of Columns In Group                 =         1
Load Data
Analysis Reference No.                 =         10
Critical Analysis Load Combination :             24
Load Combination                       =         [20] : 0.7 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location                      =         Bottom Joint
Put                                    =         106.44                                kN
Muxt                                   =         -0.58                                 kNm
Muyt                                   =         20.92                                 kNm
Vuxt                                   =         -26.7                                 kN
Vuyt                                   =         1.2                                   kN
Pub                                    =         109.08                                kN
Muxb                                   =         0.62                                  kNm
Muyb                                   =         47.61                                 kNm
Vuxb                                   =         -26.7                                 kN
Vuyb                                   =         1.2                                   kN
Effective Length Calculation
Calculation Along Major Axis Of Column
    Joint        Column             Beam Sizes                   Beam Stiffness          Beta
                Stiffness      Beam 1       Beam 2             Beam 1     Beam 2
                                 (Length x      (Length x
                               Width x Depth) Width x Depth)
                   N-M              mm             mm           N-M        N-M
     Bottom       195.523        No Beam        No Beam           -         -              1
                                3600 x 200 x
      Top         195.523                       No Beam         11.456       -           22.756
                                    300
Sway Condition (as per Stability
                                       =         Non Sway
Index)
Effective Length Factor along Major
                                       =         0.87
Axis
Along B
          Q                           =        0.003
                                      0.003< 0.05, Column shall be designed as non-sway
                                      frame (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                         =      0.87
r                                         =      115.47                            mm
Kluy /r                                   =      5.27
M1                                        =      -0.58                             kNm
M2                                        =      0.62                              kNm
34 - 12 x (M1/M2)                     =         45.31
                                      5.27 < 45.31, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =        0.87
r                                     =        115.47                                mm
Klux /r                               =        5.27
M1                                    =        20.92                                 kNm
M2                                    =        47.61                                 kNm
34 - 12 x (M1/M2)                     =         28.73
                                      5.27 < 28.73, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                 MAX((Left,Top + Right,Bot),
 Mnty                                   =
                                                 (Right,Top + Left,Bot))
                                        =        46.43                                       kNm
 Design Of Shear
 Design for shear along D
 Shear from Moment Capacity:
 Pu                                     =        109.08                                      kN
 Luy                                    =        700                                         mm
 Mnty                                   =        87.21                                       kNm
 Mnby                                   =        87.21                                       kNm
 Vuy1                                   =        249.17                                      kN
 Shear from Beam Capacity at Joint:
 Luy                                    =        700                                         mm
 Mnty                                   =        46.43                                       KN-m
 Mnby                                   =        0                                           KN-m
 Vuy2                                   =        66.32                                       KN
 Critical Analysis Load Combination :            19
Critical Load Combination            =       [15] : 1.4 (LOAD 3: DL) +1.25 (LOAD kN
                                             1: EX)
Nu                                   =       199.17                              kN
Muy                                  =       41.5                               kNm
Vuy                                  =       20.4868                            kN
Design Shear                         =       max(Vuy, Vuy1, Vuy2)
                                     =       249.17                             kN
λ                                    =       1
φ                                    =       0.65
deff                                 =       352                                mm
ρw                                   =       0.005
mm                                   =       10.43                              kNm
Vcy Permissible                      =       128.66                             kN
Vuy                                  >       Vcy Permissible
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                              mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                               mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                             mm
48 x diameter of links                  =        480                             mm
Provided spacing                        =        125                             mm
General Data
Column No.                             :        C4
Level                                  :        1m To 4m
Design Code                            =        ACI 318M - 2011
Grade Of Concrete                      =        C21                                          N/sqmm
Grade Of Steel                         =        Fy230                                        N/sqmm
Consider Ductile                       =        Yes
Type of Frame                          =        Special
Column B                               =        400                                          mm
Column D                               =        400                                          mm
Clear Cover                            =        40                                           mm
Clear Floor Height @ lux               =        2600                                         mm
Clear Floor Height @ luy               =        2600                                         mm
No Of Floors                           =        1
No Of Columns In Group                 =        1
Load Data
Analysis Reference No.                 =        11
Critical Analysis Load Combination :            24
Load Combination                       =        [20] : 0.7 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location                      =         Bottom Joint
Put                                    =         92.73                              kN
Muxt                                   =         5.61                               kNm
Muyt                                   =         -29.12                             kNm
Vuxt                                   =         -20.87                             kN
Vuyt                                   =         -2.57                              kN
Pub                                    =         100.65                             kN
Muxb                                   =         -2.09                              kNm
Muyb                                   =         33.47                              kNm
Vuxb                                   =         -20.87                             kN
Vuyb                                   =         -2.57                              kN
Along B
          Q                          =         0.006
                                     0.006< 0.05, Column shall be designed as non-sway frame
                                     (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =        1
r                                     =        115.47                                 mm
Kluy /r                               =        22.52
M1                                    =        -2.09                                  kNm
M2                                    =        5.61                                   kNm
34 - 12 x (M1/M2)                     =         38.48
                                      22.52 < 38.48, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =        1
r                                     =        115.47                                 mm
Klux /r                               =        22.52
M1                                    =        -29.12                                 kNm
M2                                    =        33.47                                  kNm
34 - 12 x (M1/M2)                     =         44.44
                                      22.52 < 44.44, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Final Critical Design Forces
 Moment Along B:
                                                    MAX((Left,Top + Right,Bot),
 Mnby                                    =
                                                    (Right,Top + Left,Bot))
                                         =          46.43                                   kNm
 Design Of Shear
 Design for shear along D
 Shear from Moment Capacity:
 Pu                                      =          100.65                                  kN
 Luy                                     =          2600                                    mm
 Mnty                                    =          84.68                                   kNm
 Mnby                                    =          84.68                                   kNm
 Vuy1                                    =          65.14                                   kN
 Shear from Beam Capacity at Joint:
 Luy                                     =          2600                                    mm
 Mnty                                    =          115.5                                   KN-m
Mnby                                     =       46.43                                 KN-m
Vuy2                                     =       62.28                                 KN
Critical Analysis Load Combination   :           21
Critical Load Combination            =           [17] : 1.4 (LOAD 3: DL) -1.25 (LOAD   kN
                                                 1: EX)
Nu                                   =           201.13                                kN
Muy                                  =           34.12                                 kNm
Vuy                                  =           -22.4746                              kN
Design Shear                         =           max(Vuy, Vuy1, Vuy2)
                                     =           65.14                                 kN
λ                                    =           1
φ                                    =           0.65
deff                                 =           352                                   mm
ρw                                   =           0.005
mm                                   =           2.74                                  kNm
Vcy Permissible                      =           111.32                                kN
Vuy                                  <           Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                              mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                               mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                             mm
48 x diameter of links                  =        480                             mm
Provided spacing                        =        200                             mm
General Data
Column No.                             :            C4
Level                                  :            4m To 7m
Design Code                            =            ACI 318M - 2011
Grade Of Concrete                      =            C21                                  N/sqmm
Grade Of Steel                         =            Fy230                                N/sqmm
Consider Ductile                       =            Yes
Type of Frame                          =            Special
Column B                               =            400                                  mm
Column D                               =            400                                  mm
Clear Cover                           =          40                                  mm
Clear Floor Height @ lux              =          2700                                mm
Clear Floor Height @ luy              =          2700                                mm
No Of Floors                          =          1
No Of Columns In Group                =          1
Load Data
Analysis Reference No.                =         12
Critical Analysis Load Combination    :         21
Load Combination                      =         [17] : 1.4 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location                     =         Top Joint
Put                                   =         46.67                                kN
Muxt                                  =         21.76                                kNm
Muyt                                  =         1                                    kNm
Vuxt                                  =         0.44                                 kN
Vuyt                                  =         -14.13                               kN
Pub                                   =         62.51                                kN
Muxb                                  =         -20.61                               kNm
Muyb                                  =         -0.32                                kNm
Vuxb                                  =         0.44                                 kN
Vuyb                                  =         -14.13                               kN
                                 (Length x      (Length x
                               Width x Depth) Width x Depth)
                    N-M             mm             mm           N-M          N-M
                                3600 x 250 x
      Bottom        65.174                      No Beam        33.945          -             3.844
                                    400
                                3600 x 200 x
       Top          65.174                      No Beam        11.456          -             5.689
                                    300
Sway Condition (as per Stability
                                      =          Non Sway
Index)
Effective Length Factor along Major
                                      =          1
Axis
Along B
          Q                            =         0.003
                                       0.003< 0.05, Column shall be designed as non-sway
                                       frame (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                      =          1
r                                      =          115.47                            mm
Kluy /r                                =          23.38
M1                                     =          -20.61                            kNm
M2                                     =          21.76                             kNm
34 - 12 x (M1/M2)                      =         45.37
                                       23.38 < 45.37, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =        1
r                                     =        115.47                                mm
Klux /r                               =        23.38
M1                                    =        -0.32                                 kNm
M2                                    =        1                                     kNm
34 - 12 x (M1/M2)                     =         37.83
                                      23.38 < 37.83, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                     MAX((Left,Top + Right,Bot),
 Mnty                                    =
                                                     (Right,Top + Left,Bot))
                                         =           46.43                                   kNm
 Beams at Level: Bottom Joint
Beam Beam Torsion Moment Capacity Beam at Moment Capacity Beam at          Resultant Moment
 Size angle moment             Top                    Bottom
       w.r.t.
      column
        Ly
                     Mu Ast req Ast pro Mu    Mu Ast req Ast pro Mu Top Top Bot @ Bot @
                                         cap                      cap @ D @ B          D    B
(mm) (deg) (kNm) (kNm) (sqmm) (sqmm) (kNm) (kNm) (sqmm) (sqmm) (kNm) (kNm) (kNm) (kNm) (kNm)
250 x
         0    -1.85 49.06 714.82 829.38 66.38 8.36 418.41 603.18 49.13 66.38   0     49.13 0
 400
250 x   90    -0.6    51.79 757.01 829.38 66.38    5.03 418.41 603.18 49.13      0    66.38     0   49.13
 400
250 x   270   -0.75   51.36 750.4 829.38 66.38     5.24 418.41 603.18 49.13      0    66.38     0   49.13
 400
 Moment Along B:
                                                  MAX((Left,Top + Right,Bot),
 Mnby                                 =
                                                  (Right,Top + Left,Bot))
                                      =           115.5                                   kNm
Design Of Shear
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                              mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                               mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                             mm
48 x diameter of links                  =        480                             mm
Provided spacing                        =        200                             mm
General Data
Column No.                           :          C5
Level                                :          0m To 1m
Design Code                          =          ACI 318M - 2011
Grade Of Concrete                    =          C21                                  N/sqmm
Grade Of Steel                       =          Fy230                                N/sqmm
Consider Ductile                     =          Yes
Type of Frame                        =          Special
Column B                             =          400                                  mm
Column D                             =          400                                  mm
Clear Cover                          =          40                                   mm
Clear Floor Height @ lux             =          700                                  mm
Clear Floor Height @ luy             =          700                                  mm
No Of Floors                          =          1
No Of Columns In Group                =          1
Load Data
Analysis Reference No.                =          13
Critical Analysis Load Combination    :          23
Load Combination                      =          [19] : 0.7 (LOAD 3: DL) +1.25 (LOAD 1: EX)
Critical Location                     =          Bottom Joint
Put                                   =          122.88                                kN
Muxt                                  =          19.36                                 kNm
Muyt                                  =          0.71                                  kNm
Vuxt                                  =          0.8                                   kN
Vuyt                                  =          22.41                                 kN
Pub                                   =          125.52                                kN
Muxb                                  =          41.77                                 kNm
Muyb                                  =          -0.09                                 kNm
Vuxb                                  =          0.8                                   kN
Vuyb                                  =          22.41                                 kN
Along B
          Q                           =         0.003
                                      0.003< 0.05, Column shall be designed as non-sway frame
                                      (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =         0.87
r                                     =         115.47                              mm
Kluy /r                               =         5.27
M1                                    =         19.36                               kNm
M2                                    =         41.77                               kNm
34 - 12 x (M1/M2)                     =         28.44
                                      5.27 < 28.44, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =         0.87
r                                     =         115.47                              mm
Klux /r                               =         5.27
M1                                    =         -0.09                               kNm
M2                                    =         0.71                                kNm
34 - 12 x (M1/M2)                     =         35.54
                                      5.27 < 35.54, Column not slender along B
Moment Along B:
                                             MAX((Left,Top + Right,Bot),
Mnty                                 =
                                             (Right,Top + Left,Bot))
                                     =       46.43                                   kNm
Design Of Shear
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                              mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                               mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                             mm
48 x diameter of links                  =        480                             mm
Provided spacing                        =        125                             mm
General Data
Column No.                             :            C5
Level                                  :            1m To 4m
Design Code                            =            ACI 318M - 2011
Grade Of Concrete                      =            C100                                 N/sqmm
Grade Of Steel                         =            Fy230                                N/sqmm
Consider Ductile                       =            Yes
Type of Frame                         =         Special
Column B                              =         400                                  mm
Column D                              =         400                                  mm
Clear Cover                           =         40                                   mm
Clear Floor Height @ lux              =         2600                                 mm
Clear Floor Height @ luy              =         2600                                 mm
No Of Floors                          =         1
No Of Columns In Group                =         1
Load Data
Analysis Reference No.                =         14
Critical Analysis Load Combination    :         24
Load Combination                      =         [20] : 0.7 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location                     =         Top Joint
Put                                   =         124.98                               kN
Muxt                                  =         -2.83                                kNm
Muyt                                  =         -42.35                               kNm
Vuxt                                  =         -25.74                               kN
Vuyt                                  =         1.49                                 kN
Pub                                   =         132.9                                kN
Muxb                                  =         1.64                                 kNm
Muyb                                  =         34.85                                kNm
Vuxb                                  =         -25.74                               kN
Vuyb                                  =         1.49                                 kN
                                (Length x      (Length x
                              Width x Depth) Width x Depth)
                    N-M            mm             mm           N-M           N-M
                               2600 x 200 x 3600 x 200 x
      Bottom        65.174                                    34.615           25            9.561
                                   300            300
                               2600 x 250 x 3600 x 250 x
       Top          65.174                                    102.564       74.074           1.612
                                   400            400
Sway Condition (as per Stability
                                      =          Non Sway
Index)
Effective Length Factor along Major
                                      =          1
Axis
    Calculation Along Minor Axis Of Column
        Joint       Column             Beam Sizes                   Beam Stiffness          Beta
                    Stiffness     Beam 1      Beam 2              Beam 1     Beam 2
                                    (Length x      (Length x
                                  Width x Depth) Width x Depth)
                        N-M            mm             mm           N-M        N-M
                                   4100 x 200 x 4100 x 200 x
         Bottom         65.174                                    21.951     21.951         12.929
                                       300            300
                                   4100 x 250 x 4100 x 250 x
          Top           65.174                                    65.041     65.041         2.188
                                       400            400
    Sway Condition (as per Stability Index)
    Effective Length Factor along Minor axis
=            Non Sway
= 1
    Along B
              Q                          =         0.006
                                          0.006< 0.05, Column shall be designed as non-sway
                                          frame (Braced)
    Slenderness Check
    Column Is Braced Along D
    Slenderness Check along D
    K                                     =         1
    r                                     =         115.47                            mm
    Kluy /r                               =         22.52
    M1                                    =         1.64                              kNm
    M2                                    =         -2.83                             kNm
    34 - 12 x (M1/M2)                     =         40.93
                                          22.52 < 40.93, Column not slender along D
    Column Is Braced Along B
    Slenderness Check along B
    K                                     =         1
    r                                     =         115.47                            mm
    Klux /r                               =         22.52
    M1                                    =         34.85                             kNm
    M2                                    =         -42.35                            kNm
    34 - 12 x (M1/M2)                     =         43.87
                                      22.52 < 43.87, Column not slender along B
Where
A       = Moments from analysis
B       = Moment due to slenderness effect
C       = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                     MAX((Left,Top + Right,Bot),
 Mnty                                  =
                                                    (Right,Top + Left,Bot))
                                       =            142.82                                       kNm
Moment Along B:
                                           MAX((Left,Top + Right,Bot),
Mnby                                 =
                                           (Right,Top + Left,Bot))
                                     =     46.43                                   kNm
Design Of Shear
Design for shear along D
Shear from Moment Capacity:
Pu                                   =     124.98                                  kN
Luy                                  =     2600                                    mm
Mnty                                 =     103.49                                  kNm
Mnby                                 =     103.49                                  kNm
Vuy1                                 =     79.61                                   kN
Shear from Beam Capacity at Joint:
Luy                                  =     2600                                    mm
Mnty                                 =     142.82                                  KN-m
Mnby                                 =     46.43                                   KN-m
Vuy2                                 =     72.79                                   KN
Critical Analysis Load Combination   :     25
Critical Load Combination            =     [21] : 0.7 (LOAD 3: DL) -1.25 (LOAD     kN
                                           1: EX)
Nu                                   =     138.66                                  kN
Muy                                  =     28.79                                   kNm
Vuy                                  =     -20.5231                                kN
Design Shear                         =     max(Vuy, Vuy1, Vuy2)
                                     =     79.61                                   kN
λ                                    =     1
φ                                    =     0.65
deff                                 =     352                                     mm
ρw                                   =     0.005
mm                                   =     7.16                                    kNm
Vcy Permissible                      =     236.99                                  kN
Vuy                                  <     Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                                     mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                                      mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                                    mm
48 x diameter of links                  =        480                                    mm
Provided spacing                        =        200                                    mm
Criterion for spacing of Ductile
links:
Min. Longitudinal Bar dia x 6            =      96                                   mm
B/4                                      =      100                                  mm
So                                       =      191.67                               mm
Spacing                                  =      150                                  mm
Provided Spacing                         =      75                                   mm
General Data
Column No.                           :          C5
Level                                :          4m To 7m
Design Code                          =          ACI 318M - 2011
Grade Of Concrete                    =          C21                                  N/sqmm
Grade Of Steel                       =          Fy230                                N/sqmm
Consider Ductile                     =          Yes
Type of Frame                        =          Special
Column B                             =          400                                  mm
Column D                             =          400                                  mm
Clear Cover                           =          40                                   mm
Clear Floor Height @ lux              =          2700                                 mm
Clear Floor Height @ luy              =          2700                                 mm
No Of Floors                          =          1
No Of Columns In Group                =          1
Load Data
Analysis Reference No.                =          15
Critical Analysis Load Combination    :          24
Load Combination                      =          [20] : 0.7 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location                     =          Bottom Joint
Put                                   =          32.95                                kN
Muxt                                  =          -3.03                                kNm
Muyt                                  =          -13.17                               kNm
Vuxt                                  =          -12.6                                kN
Vuyt                                  =          2.35                                 kN
Pub                                   =          40.87                                kN
Muxb                                  =          4.03                                 kNm
Muyb                                  =          24.63                                kNm
Vuxb                                  =          -12.6                                kN
Vuyb                                  =          2.35                                 kN
Along B
          Q                           =         0.003
                                      0.003< 0.05, Column shall be designed as non-sway frame
                                      (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =         1
r                                     =         115.47                               mm
Kluy /r                               =         23.38
M1                                    =         -3.03                                kNm
M2                                    =         4.03                                 kNm
34 - 12 x (M1/M2)                     =         43.04
                                      23.38 < 43.04, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =         1
r                                     =         115.47                               mm
Klux /r                               =         23.38
M1                                    =         -13.17                               kNm
M2                                    =         24.63                                kNm
34 - 12 x (M1/M2)                     =         40.42
                                      23.38 < 40.42, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                       MAX((Left,Top + Right,Bot),
 Mnty                                       =
                                                       (Right,Top + Left,Bot))
                                            =          58.37                                        kNm
 Moment Along B:
                                                       MAX((Left,Top + Right,Bot),
 Mnby                                       =
                                                       (Right,Top + Left,Bot))
                                            =          142.82                                       kNm
 Design Of Shear
Design for shear along D
Shear from Moment Capacity:
Pu                                   =           40.87                               kN
Luy                                  =           2700                                mm
Mnty                                 =           76.65                               kNm
Mnby                                 =           76.65                               kNm
Vuy1                                 =           56.78                               kN
Shear from Beam Capacity at Joint:
Luy                                  =           2700                                mm
Mnty                                 =           58.37                               KN-m
Mnby                                 =           142.82                              KN-m
Vuy2                                 =           74.51                               KN
Critical Analysis Load Combination   :           14
                                                 LL)
Nu                                   =           26.41                               kN
Muy                                  =           4.15                                kNm
Vuy                                  =           2.0577                              kN
Design Shear                         =           max(Vuy, Vuy1, Vuy2)
                                     =           59.97                               kN
λ                                    =           1
φ                                    =           0.65
deff                                 =           352                                 mm
ρw                                   =           0.005
mm                                   =           0.03                                kNm
Vcy Permissible                      =           164.44                              kN
Vuy                                  <           Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                                     mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                                      mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                                    mm
48 x diameter of links                  =        480                                    mm
Provided spacing                        =        200                                    mm
General Data
Column No.                             :         C6
Level                                  :         0m To 1m
Design Code                            =         ACI 318M - 2011
Grade Of Concrete                      =         C21                                  N/sqmm
Grade Of Steel                         =         Fy230                                N/sqmm
Consider Ductile                       =         Yes
Type of Frame                          =         Special
Column B                               =         400                                  mm
Column D                               =         400                                  mm
Clear Cover                            =         40                                   mm
Clear Floor Height @ lux               =         700                                  mm
Clear Floor Height @ luy               =         700                                  mm
No Of Floors                           =         1
No Of Columns In Group                 =         1
Load Data
Analysis Reference No.                 =         16
Critical Analysis Load Combination :             25
Load Combination                       =         [21] : 0.7 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location                      =         Bottom Joint
Put                                    =         35.26                                kN
Muxt                                   =         -20.67                               kNm
Muyt                                   =         1.69                                 kNm
Vuxt                                   =         0.03                                 kN
Vuyt                                      =        -19.81                                  kN
Pub                                       =        37.9                                    kN
Muxb                                      =        -40.47                                  kNm
Muyb                                      =        1.66                                    kNm
Vuxb                                      =        0.03                                    kN
Vuyb                                      =        -19.81                                  kN
Along B
         Q                            =          0.003
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =          0.87
r                                     =          115.47                              mm
Kluy /r                               =          5.27
M1                                    =          -20.67                              kNm
M2                                    =          -40.47                              kNm
34 - 12 x (M1/M2)                     =         27.87
                                      5.27 < 27.87, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =          0.87
r                                     =          115.47                              mm
Klux /r                               =          5.27
M1                                    =          1.66                                kNm
M2                                    =          1.69                                kNm
34 - 12 x (M1/M2)                     =         22.21
                                      5.27 < 22.21, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                    MAX((Left,Top + Right,Bot),
 Mnty                                   =
                                                    (Right,Top + Left,Bot))
                                        =           46.43                                       kNm
Design Of Shear
Design for shear along D
Shear from Moment Capacity:
Pu                                   =       37.9                                kN
Luy                                  =       700                                 mm
Mnty                                 =       76.19                               kNm
Mnby                                 =       76.19                               kNm
Vuy1                                 =       217.7                               kN
Shear from Beam Capacity at Joint:
Luy                                  =       700                                 mm
Mnty                                 =       46.43                               KN-m
Mnby                                 =       0                                   KN-m
Vuy2                                 =       66.32                               KN
Critical Analysis Load Combination   :       15
Critical Load Combination            =       [11] : 1.4 (LOAD 3: DL) +0.5 (LOAD 4: kN
                                             LL) +1.25 (LOAD 1: EX)
Nu                                   =       171.85                                kN
Muy                                  =       40.94                               kNm
Vuy                                  =       18.6144                             kN
Design Shear                         =       max(Vuy, Vuy1, Vuy2)
                                     =       217.7                               kN
λ                                    =       1
φ                                    =       0.65
deff                                 =       352                                 mm
ρw                                   =       0.005
mm                                   =       14.13                               kNm
Vcy Permissible                      =       125.76                              kN
Vuy                                  >       Vcy Permissible
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                       =                                                       =
                                       >              Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16   =   10                              mm
48 x diameter of links           =   Max. longitudinal bar dia / 4
Provided spacing                 =   4                               mm
                                     256                             mm
                                     480                             mm
                                     150                             mm
Criterion for spacing of Ductile
links:
Min. Longitudinal Bar dia x 6            =      96                                   mm
B/4                                      =      100                                  mm
So                                       =      191.67                               mm
Spacing                                  =      150                                  mm
Provided Spacing                         =      75                                   mm
General Data
Column No.                           :          C6
Level                                :          1m To 4m
Design Code                          =          ACI 318M - 2011
Grade Of Concrete                    =          C21                                  N/sqmm
Grade Of Steel                       =          Fy230                                N/sqmm
Consider Ductile                     =          Yes
Type of Frame                        =          Special
Column B                             =          400                                  mm
Column D                             =          400                                  mm
Clear Cover                          =          40                                   mm
Clear Floor Height @ lux              =          2600                                mm
Clear Floor Height @ luy              =          2600                                mm
No Of Floors                          =          1
No Of Columns In Group                =          1
Load Data
Analysis Reference No.                =         17
Critical Analysis Load Combination    :         24
Load Combination                      =         [20] : 0.7 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location                     =         Top Joint
Put                                   =         60.6                                 kN
Muxt                                  =         -1.72                                kNm
Muyt                                  =         -37.3                                kNm
Vuxt                                  =         -22.46                               kN
Vuyt                                  =         0.95                                 kN
Pub                                   =         68.51                                kN
Muxb                                  =         1.12                                 kNm
Muyb                                  =         30.06                                kNm
Vuxb                                  =         -22.46                               kN
Vuyb                                  =         0.95                                 kN
Along B
          Q                          =         0.006
                                     0.006< 0.05, Column shall be designed as non-sway frame
                                     (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =        0.83
r                                     =        115.47                                mm
Kluy /r                               =        18.69
M1                                    =        1.12                                  kNm
M2                                    =        -1.72                                 kNm
34 - 12 x (M1/M2)                     =         41.8
                                      18.69 < 41.8, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =        1
r                                     =        115.47                                mm
Klux /r                               =        22.52
M1                                    =        30.06                                 kNm
M2                                    =        -37.3                                 kNm
34 - 12 x (M1/M2)                     =         43.67
                                      22.52 < 43.67, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Final Critical Design Forces
 Critical Case - Axial Load & BiAxial Bending
 Pu                                      =        60.6                                        kN
 Mux                                     =        -1.72                                       kNm
 Muy                                     =        -37.3                                       kNm
 Moment Along B:
                                                 MAX((Left,Top + Right,Bot),
 Mnty                                 =
                                                 (Right,Top + Left,Bot))
                                      =          115.5                                       kNm
 Moment Along B:
                                                 MAX((Left,Top + Right,Bot),
 Mnby                                 =
                                                 (Right,Top + Left,Bot))
                                      =          46.43                                       kNm
 Design Of Shear
 Design for shear along D
 Shear from Moment Capacity:
Pu                                   =           60.6                               kN
Luy                                  =           2600                               mm
Mnty                                 =           80.93                              kNm
Mnby                                 =           80.93                              kNm
Vuy1                                 =           62.26                              kN
Shear from Beam Capacity at Joint:
Luy                                  =           2600                               mm
Mnty                                 =           115.5                              KN-m
Mnby                                 =           46.43                              KN-m
Vuy2                                 =           62.28                              KN
Critical Analysis Load Combination   :           20
Critical Load Combination            =           [16] : 1.4 (LOAD 3: DL) +1.25 (LOAD kN
                                                 2: EZ)
Nu                                   =           133.26                              kN
Muy                                  =           2.24                               kNm
Vuy                                  =           1.9003                             kN
Design Shear                         =           max(Vuy, Vuy1, Vuy2)
                                     =           62.26                              kN
λ                                    =           1
φ                                    =           0.65
deff                                 =           352                                mm
ρw                                   =           0.005
mm                                   =           18.54                              kNm
Vcy Permissible                      =           208.49                             kN
Vuy                                  <           Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                              mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                               mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                             mm
48 x diameter of links                  =        480                             mm
Provided spacing                        =        200                             mm
General Data
Column No.                             :         C6
Level                                  :         4m To 7m
Design Code                            =         ACI 318M - 2011
Grade Of Concrete                      =         C21                                  N/sqmm
Grade Of Steel                         =         Fy230                                N/sqmm
Consider Ductile                       =         Yes
Type of Frame                          =         Special
Column B                               =         400                                  mm
Column D                               =         400                                  mm
Clear Cover                            =         40                                   mm
Clear Floor Height @ lux               =         2700                                 mm
Clear Floor Height @ luy               =         2700                                 mm
No Of Floors                           =         1
No Of Columns In Group                 =         1
Load Data
Analysis Reference No.                 =         18
Critical Analysis Load Combination :             16
                                                 [12] : 1.4 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination                       =
                                                 (LOAD 2: EZ)
Critical Location                      =         Bottom Joint
Put                                    =         32.18                                kN
Muxt                                   =         -4.53                                kNm
Muyt                                   =         -18.23                               kNm
Vuxt                                   =         -14.65                               kN
Vuyt                                   =         3.24                                 kN
Pub                                    =         48.02                                kN
Muxb                                   =         5.19                                 kNm
Muyb                                      =      25.71                             kNm
Vuxb                                      =      -14.65                            kN
Vuyb                                      =      3.24                              kN
Along B
         Q                            =        0.003
                                      0.003< 0.05, Column shall be designed as non-sway
                                      frame (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =        0.74
r                                     =        115.47                                mm
Kluy /r                               =        17.3
M1                                    =        -4.53                                 kNm
M2                                    =        5.19                                  kNm
34 - 12 x (M1/M2)                     =         44.48
                                      17.3 < 44.48, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =        1
r                                     =        115.47                                mm
Klux /r                               =        23.38
M1                                    =        -18.23                                kNm
M2                                    =        25.71                                 kNm
34 - 12 x (M1/M2)                     =         42.51
                                      23.38 < 42.51, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                  MAX((Left,Top + Right,Bot),
 Mnty                                 =
                                                  (Right,Top + Left,Bot))
                                                                                               KNm
= 58.37
 Moment Along B:
                                                      MAX((Left,Top + Right,Bot),
 Mnby                                      =
                                                      (Right,Top + Left,Bot))
                                           =          115.5                                        kNm
 Design Of Shear
 Design for shear along D
 Shear from Moment Capacity:
 Pu                                        =          48.02                                        kN
 Luy                                       =          2700                                         mm
 Mnty                                      =          77.76                                        kNm
 Mnby                                      =          77.76                                        kNm
 Vuy1                                      =          57.6                                         kN
 Shear from Beam Capacity at Joint:
 Luy                                       =          2700                                         mm
 Mnty                                      =          58.37                                        KN-m
 Mnby                                      =          115.5                                        KN-m
 Vuy2                                      =          64.4                                         KN
 Critical Analysis Load Combination :                 18
 Critical Load Combination                 =          [14] : 1.4 (LOAD 3: DL) +0.5 (LOAD 4: kN
                                                      LL) -1.25 (LOAD 2: EZ)
 Nu                                        =          25.05                                  kN
 Muy                                       =          4.57                                         kNm
Vuy                                        =      3.2651                             kN
Design Shear                               =      max(Vuy, Vuy1, Vuy2)
                                        =         57.6                               kN
λ                                      =          1
φ                                      =          0.65
deff                                   =          352                                mm
ρw                                     =          0.005
mm                                     =          0.66                               kNm
Vcy Permissible                        =          156.64                             kN
Vuy                                    <          Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =       10                                   mm
General Data
Column No.                              :       C7
Level                                   :       0m To 1m
Design Code                          =          ACI 318M - 2011
Grade Of Concrete                    =          C21                                   N/sqmm
Grade Of Steel                       =          Fy230                                 N/sqmm
Consider Ductile                     =          Yes
Type of Frame                        =          Special
Column B                             =          400                                   mm
Column D                             =          400                                   mm
Clear Cover                          =          40                                    mm
Clear Floor Height @ lux             =          700                                   mm
Clear Floor Height @ luy             =          700                                   mm
No Of Floors                         =          1
No Of Columns In Group               =          1
Load Data
=   0.87
Calculation Along Minor Axis Of Column
    Joint        Column             Beam Sizes                  Beam Stiffness            Beta
                Stiffness      Beam 1       Beam 2            Beam 1      Beam 2
                                (Length x      (Length x
                              Width x Depth) Width x Depth)
                     N-M           mm             mm           N-M          N-M
     Bottom         195.523     No Beam        No Beam          -             -             1
                                              4100 x 200 x
      Top           195.523     No Beam           300           -          10.059         25.859
Along B
          Q                           =         0.003
                                      0.003< 0.05, Column shall be designed as non-sway frame
                                      (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =         0.87
r                                     =         115.47                              mm
Kluy /r                               =         5.27
M1                                    =         -4.66                               kNm
M2                                    =         -4.79                               kNm
34 - 12 x (M1/M2)                     =         22.33
                                      5.27 < 22.33, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =         0.87
r                                     =         115.47                              mm
Klux /r                               =         5.27
M1                                    =         -21.7                               kNm
M2                                    =         -46.77                              kNm
34 - 12 x (M1/M2)                     =         28.43
                                      5.27 < 28.43, Column not slender along B
 Calculation of Design Moment
                 Direction                          Manalysis       Msldr or Mc        Mdesign-final
                                                       A                B                   C
 Major Axis Mux (top)                                 -4.66              -                    -4.66
 Major Axis Mux (bottom)                              -4.79              -                    -4.79
 Minor Axis Muy (top)                                 -21.7              -                    -21.7
 Minor Axis Muy (bottom)                             -46.77              -                   -46.77
 Where
 A       = Moments from analysis
 B       = Moment due to slenderness effect
 C       = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
Moment Along B:
                                               MAX((Left,Top + Right,Bot),
Mnty                                  =
                                               (Right,Top + Left,Bot))
                                      =        23.21                                   kNm
Design Of Shear
Design for shear along D
Shear from Moment Capacity:
Pu                                    =        56.68                                   kN
Luy                                   =        700                                     mm
Mnty                                  =        78.69                                   kNm
Mnby                                  =        78.69                                   kNm
Vuy1                                  =        224.84                                  kN
Shear from Beam Capacity at Joint:
Luy                                   =        700                                     mm
Mnty                                  =        23.21                                   KN-m
Mnby                                  =        0                                       KN-m
Vuy2                                  =        33.16                                   KN
Critical Analysis Load Combination    :        19
Critical Load Combination             =        [15] : 1.4 (LOAD 3: DL) +1.25 (LOAD kN
                                               1: EX)
Nu                                    =        119.64                              kN
Muy                                   =        43.64                                   kNm
Vuy                                   =        20.8681                                 kN
Design Shear                          =        max(Vuy, Vuy1, Vuy2)
                                      =        224.84                                  kN
λ                                     =        1
φ                                     =        0.65
deff                                  =        352                                     mm
ρw                                    =        0.005
mm                                    =        24.97                                   kNm
Vcy Permissible                       =        125.06                                  kN
Vuy                                   >        Vcy Permissible
Link For Shear Design Along D are required
Vs                                   =       Vu - Vcy
                                     =       99.78                                 kN
Vcx Permissible                      =       0.5 x Vcx x 0.65
                                     =       40.64
Area of shear reinforcement required, =      1232.45                               mm^2/m
Asv-D
Diameter of column master links       =      10
Number of legs provided              =       4
Spacing of links prvd, Sv            =       175                                   mm
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                              mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                               mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                             mm
48 x diameter of links                  =        480                             mm
Provided spacing                        =        175                             mm
General Data
Column No.                             :         C7
Level                                  :         1m To 4m
Design Code                            =         ACI 318M - 2011
Grade Of Concrete                      =         C21                                  N/sqmm
Grade Of Steel                         =         Fy230                                N/sqmm
Consider Ductile                       =         Yes
Type of Frame                          =         Special
Column B                               =         400                                  mm
Column D                               =         400                                  mm
Clear Cover                            =         40                                   mm
Clear Floor Height @ lux               =         2600                                 mm
Clear Floor Height @ luy               =         2600                                 mm
No Of Floors                           =         1
No Of Columns In Group                 =         1
Load Data
Analysis Reference No.                 =         20
Critical Analysis Load Combination :             20
Load Combination                       =         [16] : 1.4 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location                      =         Top Joint
Put                                    =         120.55                               kN
Muxt                                   =         5.43                                 kNm
Muyt                                   =         -35.36                               kNm
Vuxt                                   =         -23.68                               kN
Vuyt                                   =         -1.12                                kN
Pub                                    =         136.39                               kN
Muxb                                   =         2.08                                 kNm
Muyb                                   =         35.64                                kNm
Vuxb                                   =         -23.68                               kN
Vuyb                                   =         -1.12                                kN
Effective Length Calculation
Calculation Along Major Axis Of Column
    Joint        Column             Beam Sizes                   Beam Stiffness         Beta
                Stiffness      Beam 1       Beam 2             Beam 1     Beam 2
                                 (Length x      (Length x
                               Width x Depth) Width x Depth)
                    N-M             mm             mm           N-M        N-M
                                3600 x 200 x
    Bottom         65.174                       No Beam        11.456        -          22.756
                                    300
                                3600 x 250 x
     Top           65.174                       No Beam        33.945        -          3.844
                                    400
Sway Condition (as per Stability
                                       =         Non Sway
Index)
Effective Length Factor along Major
                                       =         1
Axis
Along B
          Q                           =        0.006
                                      0.006< 0.05, Column shall be designed as non-sway
                                      frame (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                         =      1
r                                         =      115.47                            mm
Kluy /r                                   =      22.52
M1                                    =        2.08                                  kNm
M2                                    =        5.43                                  kNm
34 - 12 x (M1/M2)                     =         29.4
                                      22.52 < 29.4, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =        1
r                                     =        115.47                                mm
Klux /r                               =        22.52
M1                                    =        -35.36                                kNm
M2                                    =        35.64                                 kNm
34 - 12 x (M1/M2)                     =         45.91
                                      22.52 < 45.91, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                  MAX((Left,Top + Right,Bot),
 Mnty                                 =
                                                  (Right,Top + Left,Bot))
                                      =           66.38                                   kNm
Moment Along B:
                                                 MAX((Left,Top + Right,Bot),
Mnby                                   =
                                                 (Right,Top + Left,Bot))
                                       =         23.21                                   kNm
Design Of Shear
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =             Min. Longitudinal Bar dia x 6      =
                                        >
                                        =
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =
48 x diameter of links                  =
Provided spacing                        =
256                             mm
480                             mm
200                             mm
96                              mm
B/4                                      =      100                                  mm
So                                       =      191.67                               mm
Spacing                                  =      150                                  mm
Provided Spacing                         =      75                                   mm
General Data
Column No.                           :          C7
Level                                :          4m To 7m
Design Code                          =          ACI 318M - 2011
Grade Of Concrete                    =          C21                                  N/sqmm
Grade Of Steel                       =          Fy230                                N/sqmm
Consider Ductile                     =          Yes
Type of Frame                        =          Special
Column B                             =          400                                  mm
Column D                             =          400                                  mm
Clear Cover                          =          40                                   mm
Clear Floor Height @ lux             =          2700                                 mm
Clear Floor Height @ luy             =          2700                                 mm
No Of Floors                          =          1
No Of Columns In Group                =          1
Load Data
Analysis Reference No.                =         21
Critical Analysis Load Combination    :         20
Load Combination                      =         [16] : 1.4 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location                     =         Bottom Joint
Put                                   =         24.62                                kN
Muxt                                  =         5.97                                 kNm
Muyt                                  =         -19.09                               kNm
Vuxt                                  =         -13.32                               kN
Vuyt                                  =         -4.68                                kN
Pub                                   =         40.46                                kN
Muxb                                  =         -8.05                                kNm
Muyb                                  =         20.87                                kNm
Vuxb                                  =         -13.32                               kN
Vuyb                                  =         -4.68                                kN
Along B
          Q                    =         0.003
                               0.003< 0.05, Column shall be designed as non-sway frame
                               (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                              =         1
r                              =         115.47                              mm
Kluy /r                        =         23.38
M1                             =         5.97                                kNm
M2                             =         -8.05                               kNm
34 - 12 x (M1/M2)              =         42.9
                               23.38 < 42.9, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                              =         1
r                              =         115.47                              mm
Klux /r                        =         23.38
M1                             =         -19.09                              kNm
M2                             =         20.87                               kNm
34 - 12 x (M1/M2)              =         44.98
                               23.38 < 44.98, Column not slender along B
 Moment Along B:
                                                  MAX((Left,Top + Right,Bot),
 Mnty                                 =
                                                  (Right,Top + Left,Bot))
                                      =           23.21                                     kNm
 Moment Along B:
                                                  MAX((Left,Top + Right,Bot),
 Mnby                                 =
                                                  (Right,Top + Left,Bot))
                                      =           66.38                                     kNm
 Design Of Shear
 Design for shear along D
 Shear from Moment Capacity:
 Pu                                   =           40.46                                     kN
 Luy                                  =           2700                                      mm
 Mnty                                 =           76.59                                     kNm
 Mnby                                 =           76.59                                     kNm
 Vuy1                                 =           56.73                                     kN
 Shear from Beam Capacity at Joint:
Luy                                  =           2700                                  mm
Mnty                                 =           23.21                                 KN-m
Mnby                                 =           66.38                                 KN-m
Vuy2                                 =           33.18                                 KN
Critical Analysis Load Combination   :           16
Critical Load Combination            =           [12] : 1.4 (LOAD 3: DL) +0.5 (LOAD 4: kN
                                                 LL) +1.25 (LOAD 2: EZ)
Nu                                   =           20.85                                 kN
Muy                                  =           4.65                                  kNm
Vuy                                  =           -3.9658                               kN
Design Shear                         =           max(Vuy, Vuy1, Vuy2)
                                     =           56.73                                 kN
λ                                    =           1
φ                                    =           0.65
deff                                 =           352                                   mm
ρw                                   =           0.005
mm                                   =           1.39                                  kNm
Vcy Permissible                      =           154.94                                kN
Vuy                                  <           Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                              mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                               mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                             mm
48 x diameter of links                  =        480                             mm
Provided spacing                        =        200                             mm
General Data
Column No.                             :         C8
Level                                  :         0m To 1m
Design Code                            =         ACI 318M - 2011
Grade Of Concrete                      =         C21                                  N/sqmm
Grade Of Steel                         =         Fy230                                N/sqmm
Consider Ductile                       =         Yes
Type of Frame                          =         Special
Column B                               =         400                                  mm
Column D                               =         400                                  mm
Clear Cover                            =         40                                   mm
Clear Floor Height @ lux               =         700                                  mm
Clear Floor Height @ luy               =         700                                  mm
No Of Floors                           =         1
No Of Columns In Group                 =         1
Load Data
Analysis Reference No.                 =         22
Critical Analysis Load Combination :             23
Load Combination                       =         [19] : 0.7 (LOAD 3: DL) +1.25 (LOAD 1: EX)
Critical Location                      =         Bottom Joint
Put                                    =         75.46                                kN
Muxt                                   =         19.96                                kNm
Muyt                                   =         2.24                                 kNm
Vuxt                                   =         2.93                                 kN
Vuyt                                   =         24.43                                kN
Pub                                    =         78.1                                 kN
Muxb                                   =         44.38                                kNm
Muyb                                   =         -0.69                                kNm
Vuxb                                   =         2.93                                 kN
Vuyb                                   =         24.43                                kN
Effective Length Calculation
Calculation Along Major Axis Of Column
    Joint       Column              Beam Sizes                    Beam Stiffness           Beta
                Stiffness      Beam 1       Beam 2             Beam 1      Beam 2
                                 (Length x      (Length x
                               Width x Depth) Width x Depth)
                   N-M              mm             mm           N-M         N-M
     Bottom       195.523        No Beam        No Beam           -           -               1
                                2600 x 200 x 3600 x 200 x
      Top         195.523                                      15.863       11.456          9.561
                                    300            300
Sway Condition (as per Stability
                                       =         Non Sway
Index)
Effective Length Factor along Major
                                       =         0.87
Axis
Along B
          Q                           =        0.003
                                      0.003< 0.05, Column shall be designed as non-sway
                                      frame (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                         =      0.87
r                                         =      115.47                              mm
Kluy /r                                   =      5.27
M1                                        =      19.96                               kNm
M2                                        =      44.38                               kNm
34 - 12 x (M1/M2)                     =         28.6
                                      5.27 < 28.6, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =        0.87
r                                     =        115.47                                mm
Klux /r                               =        5.27
M1                                    =        -0.69                                 kNm
M2                                    =        2.24                                  kNm
34 - 12 x (M1/M2)                     =         37.7
                                      5.27 < 37.7, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                 MAX((Left,Top + Right,Bot),
 Mnty                                   =
                                                 (Right,Top + Left,Bot))
                                        =        23.21                                       kNm
 Design Of Shear
 Design for shear along D
 Shear from Moment Capacity:
 Pu                                     =        78.1                                        kN
 Luy                                    =        700                                         mm
 Mnty                                   =        82.01                                       kNm
 Mnby                                   =        82.01                                       kNm
 Vuy1                                   =        234.31                                      kN
 Shear from Beam Capacity at Joint:
 Luy                                    =        700                                         mm
 Mnty                                   =        23.21                                       KN-m
 Mnby                                   =        0                                           KN-m
 Vuy2                                   =        33.16                                       KN
 Critical Analysis Load Combination :            19
Critical Load Combination            =       [15] : 1.4 (LOAD 3: DL) +1.25 (LOAD kN
                                             1: EX)
Nu                                   =       173.97                              kN
Muy                                  =       44.63                                 kNm
Vuy                                  =       24.3804                               kN
Design Shear                         =       max(Vuy, Vuy1, Vuy2)
                                     =       234.31                                kN
λ                                    =       1
φ                                    =       0.65
deff                                 =       352                                   mm
ρw                                   =       0.005
mm                                   =       17.49                                 kNm
Vcy Permissible                      =       125.47                                kN
Vuy                                  >       Vcy Permissible
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                              mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                               mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                             mm
48 x diameter of links                  =        480                             mm
Provided spacing                        =        150                             mm
General Data
Column No.                             :        C8
Level                                  :        1m To 4m
Design Code                            =        ACI 318M - 2011
Grade Of Concrete                      =        C21                                          N/sqmm
Grade Of Steel                         =        Fy230                                        N/sqmm
Consider Ductile                       =        Yes
Type of Frame                          =        Special
Column B                               =        400                                          mm
Column D                               =        400                                          mm
Clear Cover                            =        40                                           mm
Clear Floor Height @ lux               =        2600                                         mm
Clear Floor Height @ luy               =        2600                                         mm
No Of Floors                           =        1
No Of Columns In Group                 =        1
Load Data
Analysis Reference No.                 =        23
Critical Analysis Load Combination :            20
Load Combination                       =        [16] : 1.4 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location                      =         Top Joint
Put                                    =         178.03                             kN
Muxt                                   =         -8.47                              kNm
Muyt                                   =         -49.17                             kNm
Vuxt                                   =         -28.85                             kN
Vuyt                                   =         5.71                               kN
Pub                                    =         193.87                             kN
Muxb                                   =         8.64                               kNm
Muyb                                   =         37.35                              kNm
Vuxb                                   =         -28.85                             kN
Vuyb                                   =         5.71                               kN
Along B
          Q                          =         0.006
                                     0.006< 0.05, Column shall be designed as non-sway frame
                                     (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =        1
r                                     =        115.47                                 mm
Kluy /r                               =        22.52
M1                                    =        -8.47                                  kNm
M2                                    =        8.64                                   kNm
34 - 12 x (M1/M2)                     =         45.77
                                      22.52 < 45.77, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =        1
r                                     =        115.47                                 mm
Klux /r                               =        22.52
M1                                    =        37.35                                  kNm
M2                                    =        -49.17                                 kNm
34 - 12 x (M1/M2)                     =         43.11
                                      22.52 < 43.11, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                     MAX((Left,Top + Right,Bot),
 Mnty                                    =
                                                     (Right,Top + Left,Bot))
                                         =          66.38                                       kNm
 Moment Along B:
                                                    MAX((Left,Top + Right,Bot),
 Mnby                                    =
                                                    (Right,Top + Left,Bot))
                                         =          23.21                                       kNm
 Design Of Shear
 Design for shear along D
 Shear from Moment Capacity:
 Pu                                      =          178.03                                      kN
 Luy                                     =          2600                                        mm
 Mnty                                    =          99.58                                       kNm
 Mnby                                    =          99.58                                       kNm
 Vuy1                                    =          76.6                                        kN
 Shear from Beam Capacity at Joint:
 Luy                                     =          2600                                        mm
 Mnty                                    =          66.38                                       KN-m
 Mnby                                    =          23.21                                       KN-m
 Vuy2                                    =          34.46                                       KN
Critical Analysis Load Combination   :           20
Critical Load Combination            =           [16] : 1.4 (LOAD 3: DL) +1.25 (LOAD kN
                                                 2: EZ)
Nu                                   =           193.87                              kN
Muy                                  =           8.64                                  kNm
Vuy                                  =           5.7058                                kN
Design Shear                         =           max(Vuy, Vuy1, Vuy2)
                                     =           76.6                                  kN
λ                                    =           1
φ                                    =           0.65
deff                                 =           352                                   mm
ρw                                   =           0.005
mm                                   =           21.6                                  kNm
Vcy Permissible                      =           217.52                                kN
Vuy                                  <           Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                              mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                               mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                             mm
48 x diameter of links                  =        480                             mm
Provided spacing                        =        200                             mm
General Data
Column No.                             :            C8
Level                                  :            4m To 7m
Design Code                            =            ACI 318M - 2011
Grade Of Concrete                      =            C21                                  N/sqmm
Grade Of Steel                         =            Fy230                                N/sqmm
Consider Ductile                       =            Yes
Type of Frame                          =            Special
Column B                               =            400                                  mm
Column D                              =          400                                  mm
Clear Cover                           =          40                                   mm
Clear Floor Height @ lux              =          2700                                 mm
Clear Floor Height @ luy              =          2700                                 mm
No Of Floors                          =          1
No Of Columns In Group                =          1
Load Data
Analysis Reference No.                =          24
Critical Analysis Load Combination    :          20
Load Combination                      =          [16] : 1.4 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location                     =          Bottom Joint
Put                                   =          36.14                                kN
Muxt                                  =          -7.66                                kNm
Muyt                                  =          -24.53                               kNm
Vuxt                                  =          -20.26                               kN
Vuyt                                  =          5.65                                 kN
Pub                                   =          51.98                                kN
Muxb                                  =          9.3                                  kNm
Muyb                                  =          36.25                                kNm
Vuxb                                  =          -20.26                               kN
Vuyb                                  =          5.65                                 kN
                                 (Length x      (Length x
                               Width x Depth) Width x Depth)
                    N-M             mm             mm            N-M          N-M
                                2600 x 250 x 3600 x 250 x
      Bottom        65.174                                      47.001       33.945           1.612
                                    400            400
                                2600 x 200 x 3600 x 200 x
       Top          65.174                                      15.863       11.456           2.39
                                    300            300
Sway Condition (as per Stability
                                       =         Non Sway
Index)
Effective Length Factor along Major
                                       =         1
Axis
Along B
          Q                            =         0.003
                                       0.003< 0.05, Column shall be designed as non-sway
                                       frame (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                      =          1
r                                      =          115.47                              mm
Kluy /r                                =          23.38
M1                                     =          -7.66                               kNm
M2                                     =          9.3                                 kNm
34 - 12 x (M1/M2)                      =         43.88
                                       23.38 < 43.88, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                          =      1
r                                          =      115.47                              mm
Klux /r                                    =      23.38
M1                                         =      -24.53                              kNm
M2                                         =      36.25                               kNm
34 - 12 x (M1/M2)                       =        42.12
                                       23.38 < 42.12, Column not slender along B
Where
A       = Moments from analysis
B       = Moment due to slenderness effect
C       = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                     MAX((Left,Top + Right,Bot),
 Mnty                                    =
                                                     (Right,Top + Left,Bot))
                                         =           35.16                                       kNm
Moment Along B:
                                                 MAX((Left,Top + Right,Bot),
Mnby                                   =
                                                 (Right,Top + Left,Bot))
                                       =         66.38                                   kNm
Design Of Shear
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =             Min. Longitudinal Bar dia x 6     =
                                        >
                                        =
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =
48 x diameter of links                  =
Provided spacing                        =
256                             mm
480                             mm
200                             mm
96                              mm
B/4                                      =      100                                  mm
So                                       =      191.67                               mm
Spacing                                  =      150                                  mm
Provided Spacing                         =      75                                   mm
General Data
Column No.                           :          C9
Level                                :          0m To 1m
Design Code                          =          ACI 318M - 2011
Grade Of Concrete                    =          C21                                  N/sqmm
Grade Of Steel                       =          Fy230                                N/sqmm
Consider Ductile                     =          Yes
Type of Frame                        =          Special
Column B                             =          400                                  mm
Column D                             =          400                                  mm
Clear Cover                          =          40                                   mm
Clear Floor Height @ lux             =          700                                  mm
Clear Floor Height @ luy             =          700                                  mm
No Of Floors                           =         1
No Of Columns In Group                 =         1
Load Data
Analysis Reference No.                =          25
Critical Analysis Load Combination    :          25
Load Combination                      =          [21] : 0.7 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location                     =          Bottom Joint
Put                                   =          14.29                                  kN
Muxt                                  =          -21.66                                 kNm
Muyt                                  =          1.39                                   kNm
Vuxt                                  =          -0.4                                   kN
Vuyt                                  =          -21.34                                 kN
Pub                                   =          16.93                                  kN
Muxb                                  =          -42.99                                 kNm
Muyb                                  =          1.78                                   kNm
Vuxb                                  =          -0.4                                   kN
Vuyb                                  =          -21.34                                 kN
Along B
          Q                           =         0.003
                                      0.003< 0.05, Column shall be designed as non-sway frame
                                      (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =         0.87
r                                     =         115.47                              mm
Kluy /r                               =         5.27
M1                                    =         -21.66                              kNm
M2                                    =         -42.99                              kNm
34 - 12 x (M1/M2)                     =         27.95
                                      5.27 < 27.95, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =         0.87
r                                     =         115.47                              mm
Klux /r                               =         5.27
M1                                    =         1.39                                kNm
M2                                    =         1.78                                kNm
34 - 12 x (M1/M2)                     =         24.66
                                      5.27 < 24.66, Column not slender along B
Where
 A       = Moments from analysis
 B       = Moment due to slenderness effect
 C       = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
Design Of Shear
Design for shear along D
Shear from Moment Capacity:
Pu                                   =       16.93                              kN
Luy                                  =       700                                mm
Mnty                                 =       72.95                              kNm
Mnby                                 =       72.95                              kNm
Vuy1                                 =       208.43                             kN
Shear from Beam Capacity at Joint:
Luy                                  =       700                                mm
Mnty                                 =       23.21                              KN-m
Mnby                                 =       0                                  KN-m
Vuy2                                 =       33.16                              KN
Critical Analysis Load Combination   :       19
Critical Load Combination            =       [15] : 1.4 (LOAD 3: DL) +1.25 (LOAD kN
                                             1: EX)
Nu                                   =       144.93                              kN
Muy                                  =       43.21                              kNm
Vuy                                  =       19.3542                            kN
Design Shear                         =       max(Vuy, Vuy1, Vuy2)
                                     =       208.43                             kN
λ                                    =       1
φ                                    =       0.65
deff                                 =       352                                mm
ρw                                   =       0.005
mm                                   =       20.6                               kNm
Vcy Permissible                      =       123.66                             kN
Vuy                                  >       Vcy Permissible
Load Data
Analysis Reference No.                   =         26
Critical Analysis Load Combination       :         25
Load Combination                         =         [21] : 0.7 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location                        =         Bottom Joint
Put                                      =         8.89                                  kN
Muxt                                     =         26.19                                 kNm
Muyt                                     =         -5.37                                 kNm
Vuxt                                     =         -2.96                                 kN
Vuyt                                     =         -19.33                                kN
Pub                                      =         16.81                                 kN
Muxb                                     =         -31.78                                kNm
Muyb                                     =         3.5                                   kNm
Vuxb                                     =         -2.96                                 kN
Vuyb                                     =         -19.33                                kN
Along B
          Q                           =         0.006
                                      0.006< 0.05, Column shall be designed as non-sway frame
                                      (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =         0.83
r                                     =         115.47                              mm
Kluy /r                               =         18.69
M1                                    =         26.19                               kNm
M2                                    =         -31.78                              kNm
34 - 12 x (M1/M2)                     =         43.89
                                      18.69 < 43.89, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =         1
r                                     =         115.47                              mm
Klux /r                               =         22.52
M1                                    =        3.5                                 kNm
M2                                    =        -5.37                               kNm
34 - 12 x (M1/M2)                     =         41.84
                                      22.52 < 41.84, Column not slender along B
Where
A       = Moments from analysis
B       = Moment due to slenderness effect
C       = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                 MAX((Left,Top + Right,Bot),
 Mnty                                 =
                                                 (Right,Top + Left,Bot))
                                      =          49.13                                        kNm
Moment Along B:
                                                 MAX((Left,Top + Right,Bot),
Mnby                                 =
                                                 (Right,Top + Left,Bot))
                                     =           23.21                                   kNm
Design Of Shear
Design for shear along D
Shear from Moment Capacity:
Pu                                   =           16.81                                   kN
Luy                                  =           2600                                    mm
Mnty                                 =           71.7                                    kNm
Mnby                                 =           71.7                                    kNm
Vuy1                                 =           55.16                                   kN
Shear from Beam Capacity at Joint:
Luy                                  =           2600                                    mm
Mnty                                 =           49.13                                   KN-m
Mnby                                 =           23.21                                   KN-m
Vuy2                                 =           27.82                                   KN
Critical Analysis Load Combination   :           20
Critical Load Combination            =           [16] : 1.4 (LOAD 3: DL) +1.25 (LOAD kN
                                                 2: EZ)
Nu                                   =           117.08                              kN
Muy                                  =           8.51                                    kNm
Vuy                                  =           5.8266                                  kN
Design Shear                         =           max(Vuy, Vuy1, Vuy2)
                                     =           55.16                                   kN
λ                                    =           1
φ                                    =           0.65
deff                                 =           352                                     mm
ρw                                   =           0.005
mm                                   =           9.75                                    kNm
Vcy Permissible                      =           206.01                                  kN
Vuy                                  <           Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link                        =        10                                 mm
                                        >        Max. longitudinal bar dia / 4
                                        =        4                                  mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16          =        256                                mm
48 x diameter of links                  =        480                                mm
Provided spacing                        =        200                                mm
General Data
Column No.                             :         C9
Level                                  :         4m To 7m
Design Code                            =         ACI 318M - 2011
Grade Of Concrete                      =         C21                                  N/sqmm
Grade Of Steel                         =         Fy230                                N/sqmm
Consider Ductile                       =         Yes
Type of Frame                          =         Special
Column B                               =         400                                  mm
Column D                               =         400                                  mm
Clear Cover                            =         40                                   mm
Clear Floor Height @ lux               =         2700                                 mm
Clear Floor Height @ luy               =         2700                                 mm
No Of Floors                           =         1
No Of Columns In Group                 =         1
Load Data
Analysis Reference No.                 =         27
Critical Analysis Load Combination :             20
Load Combination                       =         [16] : 1.4 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location                      =         Bottom Joint
Put                                       =     22.17                               kN
Muxt                                      =     -6.77                               kNm
Muyt                                      =     -16.12                              kNm
Vuxt                                      =     -12.69                              kN
Vuyt                                      =     5.4                                 kN
Pub                                       =     38.01                               kN
Muxb                                      =     9.43                                kNm
Muyb                                      =     21.93                               kNm
Vuxb                                      =     -12.69                              kN
Vuyb                                      =     5.4                                 kN
Along B
          Q                           =         0.003
                                      0.003< 0.05, Column shall be designed as non-sway frame
                                      (Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K                                     =         0.74
r                                     =         115.47                               mm
Kluy /r                               =         17.3
M1                                    =         -6.77                                kNm
M2                                    =         9.43                                 kNm
34 - 12 x (M1/M2)                     =         42.62
                                      17.3 < 42.62, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K                                     =         1
r                                     =         115.47                               mm
Klux /r                               =         23.38
M1                                    =         -16.12                               kNm
M2                                    =         21.93                                kNm
34 - 12 x (M1/M2)                     =         42.82
                                      23.38 < 42.82, Column not slender along B
Where
A         = Moments from analysis
B         = Moment due to slenderness effect
C         = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
 Moment Along B:
                                                     MAX((Left,Top + Right,Bot),
 Mnty                                     =
                                                     (Right,Top + Left,Bot))
                                          =          23.21                                     kNm
 Beams at Level: Bottom Joint
Beam Beam Torsion Moment Capacity Beam at Moment Capacity Beam at       Resultant Moment
 Size angle moment          Top                      Bottom
       w.r.t.
      column
        Ly
                   Mu Ast req Ast pro Mu     Mu Ast req Ast pro Mu Top Top Bot @ Bot @
                                      cap                        cap @ D @ B       D     B
(mm) (deg) (kNm) (kNm) (sqmm) (sqmm) (kNm) (kNm) (sqmm) (sqmm) (kNm) (kNm) (kNm) (kNm) (kNm)
250 x   90    -0.68   31.03 532.61 603.18 49.13    8.05 418.41 603.18 49.13       0       49.13     0     49.13
400
250 x   180   -1.17   40.24 580.19 603.18 49.13 26.08 418.41 603.18 49.13 49.13             0     49.13     0
400
 Moment Along B:
                                                  MAX((Left,Top + Right,Bot),
 Mnby                                   =
                                                  (Right,Top + Left,Bot))
                                        =         49.13                                     kNm
 Design Of Shear
 Design for shear along D
 Shear from Moment Capacity:
 Pu                                     =         38.01                                     kN
 Luy                                    =         2700                                      mm
 Mnty                                   =         76.21                                     kNm
 Mnby                                   =         76.21                                     kNm
 Vuy1                                   =         56.45                                     kN
 Shear from Beam Capacity at Joint:
 Luy                                    =         2700                                      mm
 Mnty                                   =         23.21                                     KN-m
 Mnby                                   =         49.13                                     KN-m
 Vuy2                                   =         26.79                                     KN
 Critical Analysis Load Combination :             14
 Critical Load Combination              =         [10] : 1.2 (LOAD 3: DL) +1.6 (LOAD 4: kN
                                                  LL)
 Nu                                     =         21.2                                  kN
Muy                                  =           3.42                                  kNm
Vuy                                  =           1.5719                                kN
Design Shear                         =           max(Vuy, Vuy1, Vuy2)
                                     =           56.45                                 kN
λ                                    =           1
φ                                    =           0.65
deff                                 =           352                                   mm
ρw                                   =           0.005
mm                                   =           0.11                                  kNm
Vcy Permissible                      =           173.24                                kN
Vuy                                  <           Vcy Permissible
Link For Shear Design Along D are not required