0% found this document useful (0 votes)
498 views5 pages

RM35TF30: Product Data Sheet

This document provides a product data sheet for the RM35TF30 multifunction phase control relay. The summary includes: 1. The RM35TF30 is a modular measurement and control relay for 3-phase power supplies that monitors for asymmetry, phase failure, phase sequence, and overvoltage/undervoltage. 2. It has adjustable time delays of 0.1-10 seconds, switches loads up to 1250VA, and measures voltage ranges from 194-528V AC with measurement cycles under 140ms. 3. The relay provides 2 changeover outputs, has CE and UL certifications, an operating temperature range of -20-50°C, and mounts on a 35mm DIN rail.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
498 views5 pages

RM35TF30: Product Data Sheet

This document provides a product data sheet for the RM35TF30 multifunction phase control relay. The summary includes: 1. The RM35TF30 is a modular measurement and control relay for 3-phase power supplies that monitors for asymmetry, phase failure, phase sequence, and overvoltage/undervoltage. 2. It has adjustable time delays of 0.1-10 seconds, switches loads up to 1250VA, and measures voltage ranges from 194-528V AC with measurement cycles under 140ms. 3. The relay provides 2 changeover outputs, has CE and UL certifications, an operating temperature range of -20-50°C, and mounts on a 35mm DIN rail.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Product data sheet RM35TF30

Characteristics multifunction phase control relay RM35-T -


range 194..528 V AC

Main
Range of product Zelio Control
Product or component Modular measurement and control relays
type
Relay type Multifunction control relay
Product specific For 3-phase supply
application
Relay name RM35TF
Relay monitored Asymmetry
parameters Phase failure detection
Phase sequence
Undervoltage and overvoltage in window mode
Time delay Adjustable 0.1...10 s, 10 %
Switching capacity in 1250 VA

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
VA
Measurement range 194...528 V AC

Complementary
Reset time <= 1500 ms for at 480 V
Maximum switching voltage 250 V AC
250 V DC

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Minimum switching current 10 mA at 5 V DC

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Maximum switching current 5 A AC
5 A DC
[Us] rated supply voltage 220...480 V AC
Supply voltage limits 194...528 V AC 3 phases
Control circuit voltage limits - 12 %, + 10 % Un
Power consumption <= 2.9 VA AC
Voltage detection threshold < 194 V
Control circuit frequency 50...60 Hz +/- 10 %
Output contacts 2 C/O
Nominal output current 5A
Hysteresis 2%
Run up delay at power up 0.5 s time delay
Measuring cycle <= 140 ms measurement cycle as true rms value
Threshold adjustment voltage +2...+10 % in the range 480 V AC
+2...+20 % in the range 220...440 V AC
-12...-2 % in the range 220 V AC
2...20 % of Un selected
-20...-2 % in the range 380...480 V AC
Voltage range 220 V phase to phase
380 V phase to phase
400 V phase to phase
415 V phase to phase
440 V phase to phase
480 V phase to phase
Adjustment of asymmetry threshold 5...15 % of Un selected
Measurement accuracy +/- 10 % of the full scale value
Repeat accuracy 0.3 % for time delay
0.5 % for input and measurement circuit
Measurement error < 1 % over the whole range with voltage variation
0.05 %/°C with temperature variation
Response time < 200 ms in the event of a fault

7/9/2011
1
Marking CE : 73/23/EEC
CE : EMC 89/336/EEC
Overvoltage category III conforming to IEC 60664-1
Insulation resistance > 500 MOhm at 500 V DC conforming to IEC 60255-5
> 500 MOhm at 500 V DC conforming to IEC 60664-1
[Ui] rated insulation voltage 400 V conforming to IEC 60664-1
Supply frequency 50/60 Hz +/- 10 %
Operating position Any position without
Electrical connection 1 conductor cable 0.2...2.5 mm² AWG24...AWG12 flexible with cable end
conforming to IEC 60947-1
1 conductor cable 0.5...4 mm² AWG20...AWG11 solid without cable end
conforming to IEC 60947-1
2 conductors cable 0.2...1.5 mm² AWG24...AWG16 flexible with cable end
conforming to IEC 60947-1
2 conductors cable 0.5...2.5 mm² AWG20...AWG14 solid without cable end
conforming to IEC 60947-1
Tightening torque 0.6...1 N.m conforming to IEC 60947-1
Housing material Self-extinguishing plastic
Status LED 1 LED green for power ON
1 LED yellow for fault
1 LED yellow for relay ON
Mounting support 35 mm symmetrical DIN rail conforming to EN/IEC 60715
Electrical durability 100000 cycles
Mechanical durability 30000000 cycles
Operating rate <= 360 operations/hour under full load
Utilisation category AC-12 conforming to IEC 60947-5-1
AC-13 conforming to IEC 60947-5-1
AC-14 conforming to IEC 60947-5-1
AC-15 conforming to IEC 60947-5-1
DC-12 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
Width 35 mm
Product weight 0.13 kg

Environment
Immunity to microbreaks 10 ms
Electromagnetic compatibility Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments
conforming to EN/IEC 61000-6-3
Immunity for industrial environments conforming to EN/IEC 61000-6-2
Standards EN/IEC 60255-6
Product certifications CSA
C-Tick
GL
GOST
UL
Ambient air temperature for storage -40...70 °C
Ambient air temperature for operation -20...50 °C
Relative humidity 95 % at 55 °C conforming to IEC 60068-2-30
Vibration resistance 0.35 mm (f = 5...57.6 Hz conforming to IEC 60068-2-6/IEC 60255-21-1
1 gn (f = 57.6...150 Hz conforming to IEC 60068-2-6/IEC 60255-21-1
Shock resistance 15 gn for 11 ms conforming to IEC 60255-21-1
IP degree of protection IP20 (terminals) conforming to IEC 60529
IP30 (casing) conforming to IEC 60529
Pollution degree 3 conforming to IEC 60664-1
Dielectric test voltage 2 kV 1 min AC 50 Hz
Non-dissipating shock wave 4 kV
RoHS EUR status Compliant
RoHS EUR conformity date 0701

2
Product data sheet RM35TF30
Dimensions Drawings

Multifunction 3-Phase Supply Control Relays

Dimensions and Mounting

3
Product data sheet RM35TF30
Connections and Schema

Multifunction 3-Phase Supply Control Relays

Wiring Diagram

4
Product data sheet RM35TF30
Technical Description

Function Diagrams

Phase Sequence Control, Phase Failure Detection (U measured < 0.7 x nominal supply voltage) and Asymmetry
Detection

Tt Time delay after crossing of threshold (adjustable on front panel).


L1, Phases of the supply voltage monitored
L2,
L3
A Asymmetry threshold (adjustable from 5...15% of the nominal supply voltage)
H Hysteresis
R Output relay
Relay status: black color = energized.

Control of Overvoltage and Undervoltage in Window Mode

Tt Time delay after crossing of threshold (adjustable on front panel).


H Hysteresis
U> Overvoltage threshold
U< Undervoltage threshold
L1, Phases of the supply voltage monitored
L2,
L3
R Output relay
Relay status: black color = energized.
The overvoltage and undervoltage thresholds in window mode are adjustable from 2…20% of Un (nominal supply voltage):
Un 220 V 380, 400, 415, 440 V 480 V

Voltage threshold (%) < - 12…- 2 - 20…- 2 - 20…- 2

> + 2…+ 20 + 2…+ 20 + 2…+ 10

You might also like