Industrial Coatings +
Corrosion Protection
INDUSTRIAL COATINGS
Content
1. Introduction // Monopol Colors
2. ISO 12944 // Modern Anticorrosive Protection
3. Environmental and Health Protection // Regulations and Trends
4. Economical Comparisons // Differences in Coatings
5. Coating System for Siemens // Bilacryl PU D81
6. Pre-Treatment // Giving a good grip to the Coating
7. Processing Sequences // Always reproducible results
8. Quality Standards // Maintaining and Improving Quality
9. Contact // Monopol Colors
2
1. Introduction
2. ISO 12944
ISO 12944
Corrosion Protection
Introduction to ISO 12944:
<Corrosion protection of steel structures by protective paint systems>
Part 1: General Introduction
Part 2: Classification of Environments
Part 3: Design Considerations
Part 4: Types of Surfaces and Surface Preparation
Part 5: Protective Paint Systems
Part 6: Laboratory Performance Test Methods
Part 7: Execution and Supervision of Paint Work
Part 8: Development of Specifications for new Work/Maintenance
5
ISO 12944
Corrosivity Categories
Corrosivity Examples of typical environments
Category and Risk in a temperate climate (examples)
Exterior Interior
C1 - Heated building with clean atmosphere, e.g.
shops, offices, schools, hotels.
Very low
C2 Atmospheres with low level of pollution. Unheated buildings where condensation may
Mostly rural areas. occur, e.g. depots, sports halls.
Low
C3 Urban and industrial atmospheres, Production rooms with high humidity and some
moderate sulphur dioxide pollution. Coastal air pollution, e.g. food processing plants,
Medium
areas with low salinity. laundries, breweries, dairies.
C4 Industrial areas and coastal areas with Chemical plants, swimming pools, coastal, ship
moderate salinity. and boatyards.
High
C5-I Industrial areas with high humidity and Buildings or areas with almost permanent
aggressive atmosphere. condensation and high pollution.
Very high industrial)
C5-M Coastal and offshore areas with high Buildings or areas with almost permanent
salinity. condensation and with high pollution
Very high (marine)
6
ISO 12944
Durability
Protection Time of Coating Systems
Low = 2 – 5 Years
Medium = 5 – 15 Years
High = above 15 Years
The protection time is not a warranty period but the time after
which first bigger renovation should take place (based on a
corrosion degree Ri 3 [approx. 1 %])
Example: Corrosivity Requirement C3 H
7
ISO 12944
Performance Testing
Salt Spray Test Humidity Testing Chemical
Corrosivity Durability
ISO 7253 ISO 6270 Testing
low 48 h
C2 low medium 48 h
high 120 h
low 120 h 48 h
C3 medium medium 240 h 120 h
high 480 h 240 h
low 240 h 120 h
C4 high medium 480 h 240 h
high 720 h 480 h
low 480 h 240 h
C5-I very high medium 720 h 480 h 168 h
high 1440 h 720 h
low 480 h 240 h
C5-M very high medium 720 h 480 h
high 1440 h 720 h
8
ISO 12944
Certified Corrosive Protection
9
ISO 12944
Minimum DFT for Certified Protection
10
3. Environmental + Health Protection
ENVIRONMENT + HEALTH
Global Regulations are increasing
Compliance Examples for Paints
RoHS (Restriction of Hazardous Substances Directive)
REACH (Registration, Evaluation, Authorization
and Restriction of Chemicals)
Conflict Mineral Law
Lead and Chromefree Regulations by countries/
companies (e.g. Siemens)
VOC Regulations
12
4. Economical Comparisons
ECONOMY
Composition of a Paint
14
ECONOMY
Is 1 kg = 1 kg?
1 lit
D = Density
1 kg
15
ECONOMY
Is 1 lit = 1 lit?
1 lit
Volatile Parts Volatile Parts
(VOC, Water) (VOC, Water)
D = Coverage
Solid Parts Solid Parts
(Solid Content) (Solid Content)
16
ECONOMY
Calculation Paint Coverage
DFT
• Dry Film Theoretical
Thickness µm
• (Density Paint Coverage
kg/l) m2/l (m2/kg)
Solid Content
Volume-%
• Solid Content by Weight
in %
• Density of Solvent kg/l
• Density of Paint kg/l
17
ECONOMY
Coverage Formula
18
ECONOMY
Coverage Calculation - Example
Paint A Paint B
Paint Price per lit 120 IRS 240 IRS
Solid Content Weight-% 60 % 66 %
Density kg/l 1.5 kg/l 1.2 kg/l
Density Solvent 0.85 kg/l 1.0 kg/l
Solid Content Volume-% 29.4 % 59.2 %
19
ECONOMY
Coverage Calculation - Example
Paint A Paint B
Solid Content Volume-% 29.4 % 59.2 %
DFT 30 µm 30 µm
Theoretical Coverage m2/l 9.8 m2/l 19.7 m2/l
Theoretical Consumption kg/m2 153 g/m2 61 g/m2
Costing per m2 18.3 IRS 14.6 IRS
20
5. Coating System for Siemens
BILACRYL PU D81
Bilacryl PU D81
Modern High Solid 2-pack PU Coating
Cost effective 2-pack PU single coat (2 in 1) or top coat
High Solid coating
Easy and safe to apply, very quick drying
Application of 100 µm in single coat
Excellent adhesion and hardness
Good water, oil and chemical resistance
Good anticorrosive properties, chalking and weathering
resistance
Excellent color retention
22
BILACRYL PU D81
Siemens Environmental Policy
No compromise on compliance - also for the future
Environmental friendly coating with low VOC
Chrome and lead free pigmentation
Compliant with current VOC-regulations and environmental
regulations (REACH, RoHS)
Compliant with safety and occupational health regulations
Compliant with Siemens Global Environmental Policy
23
BILACRYL PU D81
Technical Values
BILACRYL PU D81
2-pack PU High Solid Top Coat/Unicoat with fast drying
RAL 1003 RAL 2004 RAL 7046
Signal Yellow Pure Orange Tele Grey 2
Article No. D081.27015 D081.27016 D081.27017
Density 1.33 1.29 1.40
Solid Content Weight % 69.90 % 67.50 % 75.80 %
Solid Content Volume % 58.20 % 54.80 % 62.80 %
Coverage m2/kg @ 60 µm 7.3 7.1 7.5
Coverage m2/lit @ 60 µm 9.7 9.2 10.5
24
BILACRYL PU D81
Coating Systems – Current Situation
# DFT Function Coating Remark
(practical values)
1 70 – 80 µm Anticorrosive EP-Zn - Good anticorrosive protection
Primer Silicate - To high DFT
2 40 – 60 µm Top Coat Alkyd - Easy to apply, good gloss, good
levelling
- No weathering resistance, no
chemical resistance
- Thermoplastic system – softening
with temperature, long drying
time
3 40 – 60 µm Top Coat Alkyd - do.
Σ 150 – 200 µm
25
LIFETIME OF A BUILDING
Coating Systems – Future Proposal
DFT Function Coating Remark
A 100 – 120 µm Single Coat Bilacryl PU D81 - C2 H
B 50 – 60 µm 1st Coating Bilacryl PU D81 - As system A but
due to operational
50 – 60 µm 2nd Coating Bilacryl PU D81 reasons in 2 coats
C 50 – 60 µm Anticorrosive Monopoxi Steelguard - C3 H
Primer C80
50 – 60 µm Top Coat Bilacryl PU D81
26
6. Pre-Treatment
PRE-TREATMENT
Steel Pre-Treatment
Blasting Sa 2 ½ according ISO
8501-1 is recommended
The surface must be dry and free of
grease and rust
Abrasive residues and dust have to Reference Photo for Sa 2 1/2
be removed from the surface.
Coating after blast cleaning as soon
as possible to prevent rusting
28
PRE-TREATMENT
Cleaning by Solvent
A manual cleaning by solvents is not recommended
it can affect the adhesion of the coatings especially when epoxy
coatings are used.
Often the grease particles will be spread or concentrated into the
edges.
Solvents can penetrate into porous substrates and will take long
time for a complete evaporation/drying. A quick overcoating will
seal the surface, entrapping the solvents and weakening or even
causing complete loss of adhesion.
29
PRE-TREATMENT
Rust Degrees
ISO 8501-1 Bild 1
Bild 2
Definition and photo Bild 3
documentation of 4 rust
degrees (A, B, C, D)
which do lead to
different surfaces after
blasting
30
PRE-TREATMENT
Surface Roughness
The blasting is evaluated by the roughness
Recommended roughness values:
- Epoxyester/2-pack
Epoxy-Zincprimer 35 – 45 µm
- Zincsilicates 40 – max. 60 µm
The measurement can be made either by
using electronic measuring gauge or stripes
(e.g. Testex Press-O-Film)
31
PRE-TREATMENT
Roughness // WFT // DFT
40 µm WFT 30 µm DFT
200
175
150
125
100
75
50 Surface Roughness min. 25 µm Surface Roughness max. 50
25
Steel blasted
0
Total DFT with min./max. surface roughness profile
Maximum = 50 µm surface roughness + 30 µm DFT = 80 µm Total DFT
Minimum = 25 µm surface roughness + 30 µm DFT = 55 µm Total DFT
32
7. QC – Processing Sequences
PROCESS
Quality Control – Processing Sequence
Check the actual Technical Cleaning and rinsing
Stir the paint accurately
Data Sheet equipment/hoses
Checking pot life and Apply 100 µm WFT for a Measure viscosity, dilute if
respect ing time limits DFT of 60 µm required and stir again
Cleaning/rinsing
Forced drying possible (e.g. Checking DFT possible after
equipment/hoses
after 15 min @ 80 °C/30’) approx. 12 hours
immediately after application
34
PROCESS
Measuring of Wet Film Thickness
WFT can be measured with a wet-
film-thickness gauge
WFT lies between wetted and non
wetted tooth and can easily be
metered with the scale printed on
the gauge.
Reliable average requires approx.
10 measurements on different
spots.
35
PROCESS
Measuring of Dry Film Thickness
The DFT can be measured after drying
of the paint.
On rough surfaces it is recommended to
make an “average value-zero point
calibration” on several uncoated spots.
This will allow while measuring the DFT
to consider the surface roughness of the
substrate.
36
PROCESS
Appropriate Spraying Equipment
Air Spray
Pressure: 3.5 - 6 bar
Nozzle e.g. 1.4 - 1.8 mm
Very good results by using Airmix or
Airless with HVLP-devices (with closed
pressure-tank (including integrated
stirring device)
HVLP Devices
(High Volume Low Pressure)
37
PROCESS
Maturing Time of Coatings
Maturing Time = Dry through time till a complete load of the
system will not damage the coating
Rule of thumb for 2-pack systems: Loading capacity only after
7 days (drying @ ambient temperature of 20 °C)
Following parameters do influence the maturing time:
- Temperature
- Air circulation
- DFT of the coating
- Humidity
38
PROCESS
Dew Point and Monsoon
Dew point is the temperature at which the air is saturated with
vapor. Undercutting this temperature will condense the water
vapor into liquid water, which – when it forms on a solid surface –
is called dew.
Dew point is associated with relative humidity.
High relative humidity = dew point close to current air
temperature.
With 100 % rel. humidity the dew point is equal to ambient
temperature. When moisture content remains constant and
temperature increases, relative humidity decreases.
39
PROCESS
Dew Point – Good to know
Water condensation can not be detected visually or by touching!
It is very common that humidity occurs only in micro range.
Coating on “wet” surfaces will cause blisters or paint delamination!
If the temperatures falls under dew point after coating the curing process
can slow down.
Measuring either with combined instruments (air temp, substrate temp
and rel. humidity) or with hygrometer, temperature measuring device and
comparative tables.
Surface temperature should always be 3 – 4 °C above dew point.
40
PROCESS
Dew Point – Table Example
Relative Humidity
40% 50% 60% 70% 80% 90%
Air Temperature Dew Point in ° C
25° C 10.5 13.9 16.7 19.1 21.3 23.2
24° C 9.6 12.9 15.8 18.2 20.3 22.3
23° C 8.7 12.0 14.8 17.2 19.4 21.3
22° C 7.8 11.1 13.9 16.3 18.4 20.3
21° C 6.9 10.2 12.9 15.3 17.4 19.3
20° C 6.0 9.3 12.0 14.4 16.4 18.3
19° C 5.1 8.3 11.1 13.4 15.5 17.3
18° C 4.2 7.4 10.1 12.5 14.5 16.3
17° C 3.3 6.5 9.2 11.5 13.5 15.3
16° C 2.4 5.6 8.2 10.5 12.6 14.4
15° C 1.5 4.7 7.3 9.6 11.6 13.4
14° C 0.6 3.7 6.4 8.6 10.6 12.4
13° C -0.1 2.8 5.5 7.7 9.6 11.4
12° C -1.0 1.9 4.5 6.7 8.7 10.4
41
8. Quality Standards
QUALITY STANDARDS
Color Conformity
Definition of color standards by selecting master sample
Colormetric definition of master samples according
CIE L*a*b-System
Definition of ∆E for every color, e.g.
- RAL 1003 and 2004: ∆E ≤ 2
- RAL 7046: ∆E ≤ 1
Colormetric Report for every paint batch
Master samples for every Siemens subcontractor in order to