EMCO Orifice Plate with Single Pressure Tapping
Series MEF for Insertion Between Flanges
Principle
EMCO orifice plate are used as primary elements in flow measurement
of liquid, gas and steam according to the differential pressure principle.
Construction
Design and calculation
Standards              :    ISO 5167, ASME MFC-3M, DIN 19205,
                            Shell Flow Meter Engineering Handbook,
                            L. K. Spink, AGA no. 3
Sizes                   :   DN 50 - 1200, 2" - 42"
Pressure rating         :   PN 10 - 400, 150 - 2500 lbs
Plate thickness         :   8 mm
Vent or drain hole      :   On request
Material                :   Carbon steel P265GH, AISI 316, 16Mo3,
                            13CrMo4-5, other materials on request.
0-04-012-2e                                                                  1 of 4
Mounting style         :   Between flanges with flat or raised face or groove
                           according to DIN 2526, 2513, 2512, or RF according to B 6.5
Orifice plate shapes   :   Square edge concentric, square edge eccentric, conical, 1/4 circle,
                           segment.
                           The plate is bevelled on the down stream side except for 1/4
                           circle orifice plate.
Pressure taps          :   3/8", 1/2" BSP male, Ø 12 mm, 1/2" NPT
Tap lengths            :   150 mm, others on request.
Tap location           :   At least 45 degrees apart
                           To be stated with order
Marking                :   The orifice plate is marked with "+" and"-" and
                           flow direction.
Technical Data
Accuracy               :   +
                            /- 0,6 % for β < 0,6 and equal to β for
                           β values above 0,6
Pressure loss          :   Depending on β, for β equal to 0,6 : ca. 60 %
                           of the differential pressure measured
Limits for
Reynolds No            :   Re > 1260 x β2 D according to ISO 5167
                           2000 < Re < 108 according to ASME MFC-3M
0-04-012-2e                                                                                      2 of 4
EMCO Orifice Plate Series MEF
Accessories                : Shut-off valves and condensing chambers for
                             steam flow measurement.
                             Flange assembly complete with bolts, nuts and
                             gaskets.
Dimensions for DIN flanges
  Size   Pipe         PN 10            PN 16             PN 25          PN 40          PN 64         PN 100        d1=
   DN     OD       D        d4       D       d4       D        d4     D      d4     D       d4     D       d4      D+
 50       60.3    54.5     107      54.5     107    54.5      107    54.5   107    54.5    113    53.9    119       1
 65       76.1    70.3     127      70.3     127    70.3      127    70.3   127    69.7    138    68.9    144       1
 80       88.9    82.5     142      82.5     142    82.5      142    82.5   142    81.7    148    80.9    154       1
100      114.3   107.1     162     107.1     162   107.1      168   107.1 168     106.3    174   104.3    180       1
125      133.0   125.0     192     125.0     192   125.0      194   125.0 194     124.0    210   120.4    217       2
125      139.7   131.7     192     131.7     192   131.7      194   131.7 194     130.7    210   127.1    217       2
150      159.0   150.0     218     150.0     218   150.0      224   150.0 224     147.8    247   144.8    257       2
150      168.3   159.3     218     159.3     218   159.3      224   159.3 224     157.1    247   154.1    257       2
175      193.7     -         -     182.9     248   182.5      254   182.5 265     181.1    277   176.1    287       2
200      219.1   207.3     273     207.3     273   206.5      284   206.5 290     204.9    309   199.1    324       2
250      273.0   260.4     328     260.4     329   258.8      340   252.8 352     255.4    364   248.0    391       2
300      323.9   309.7     378     309.7     384   307.9      400   307.9 417     301.9    424   295.5    458       2
350      355.6   341.4     438     339.6     444   339.6      457   338.0 474     330.6    486   323.6    512       2
350      368.0   353.8     438     353.8     444   352.0      457   350.4 474     343.0    486   336.0    512       2
400      406.4   392.2     489     390.4     495   388.8      514   384.4 546     378.0    543     -        -       2
400      419.0   404.8     489     403.0     495   401.4      514   397.0 546     390.6    543     -        -       2
500      508.0   493.8     594     492.9     617   488.0      624   479.6 628       -        -     -        -       4
600      610.0   595.8     695     592.4     734   588.0      731     -       -     -        -     -        -       4
700      711.0   695.0     810     693.4     804   686.0      833     -       -     -        -     -        -       4
800      813.0   797.0     917     793.0     911   784.6      942     -       -     -        -     -        -       4
900      914.0   896.0    1017     894.0    1011   882.0     1042     -       -     -        -     -        -       4
All dimensions in mm
D        :   Inner pipe diameter
d4       :   Outer diameter of carrier rings when mounted between flanges with facing according to DIN 2526.
d1       :   Inner diameter plate holder. When mounted between flanges with facing according to DIN 2512 and
             2513, the inner diameter is D + 1.2 mm.
0-04-012-2e                                                                                                     3 of 4
0-04-012-2e   4 of 4