Uniformance Process Studio
Patch
                              R310.2
         Software Change Notice
        Revision Date: November 4, 2013
                 Document ID: UPS3102
Notices and Trademarks
© Honeywell International Inc. 2013. All Rights Reserved.
While this information is presented in good faith and believed to be accurate, Honeywell
disclaims the implied warranties of merchantability and fitness for a particular purpose and
makes no express warranties except as may be stated in its written agreement with and for its
customer.
In no event is Honeywell liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
Honeywell PlantScape, Experion, and TotalPlant are US registered trademarks of Honeywell
International Inc.
Other brand or product names are trademarks of their respective owners.
                                  Honeywell Process Solutions
                                 1860 West Rose Garden Lane
                                   Phoenix, AZ 85027 USA
                                       1-800 822-7673
Patch Release R310.2                  Software Change Notice                                    ii
Support and Other Contacts
United States and Canada
          Contact:     Honeywell Solution Support Center
          Phone:       1-800-822-7673
                       Calls are answered by dispatcher between 6:00 am and 4:00
                       pm Mountain Standard Time. Emergency calls outside
                       normal working hours are received by an answering service
                       and returned within one hour.
          Facsimile    1-973-455-5000
          Mail:        Honeywell TAC, MS L17
                       1860 W. Rose Garden Lane
                       Phoenix, AZ, 85027 USA
Europe, Middle East, and Africa (EMEA)
          Contact:     Honeywell TAC – EMEA
          Phone:       +32-2-728-2345
          Facsimile    +32-2-728-2696
          Mail:        TAC-BE02
                       Hermes Plaza
                       Hermeslaan, 1H
                       B-1831 Diegem, Belgium
          Email:       tac-be02@honeywell.com
Pacific
          Contact:     Honeywell Global TAC – Pacific
          Phone:       1300-364-822 (toll free within Australia)
                       +61-8-9362-9559 (outside Australia)
          Facsimile    +61-8-9362-9564
          Mail:        Honeywell Limited Australia
                       5 Kitchener Way
                       Burswood, WA, 6100, Australia
          Email:       GTAC@honeywell.com
India
          Contact:     Honeywell Global TAC – India
          Phone:       +91-20- 6603-2718/19
                       1800-233-5051
          Facsimile    +91-20- 6603-9800
          Mail:        Honeywell Automation India Ltd
                       56 and 57, Hadapsar Industrial Estate
                       Hadapsar, Pune –411 013, India
          Email:       Global-TAC-India@honeywell.com
Patch Release R310.2                      Software Change Notice                   iii
Korea
        Contact:       Honeywell Global TAC – Korea
        Phone:         +82-80-782-2255 (toll free within Korea)
        Facsimile      +82-2-792-9015
        Mail:          Honeywell Co., Ltd
                       4F, Sangam IT Tower B4-4 Block
                       1590, DMC Sangam-dong, Mapo-gu
                       Seoul, 121-835, Korea
        Email:         Global-TAC-Korea@honeywell.com
People’s Republic of China
        Contact:       Honeywell Global TAC – China
        Phone:         +86- 21-2219-6888
                       800-820-0237
                       400-820-0386
        Mail:          Honeywell (China) Co., Ltd
                       33/F, Tower A, City Center, 100 Zunyi Rd.
                       Shanghai 200051, People’s Republic of China
        Email:         Global-TAC-China@honeywell.com
Singapore
        Contact:       Honeywell Global TAC – South East Asia
        Phone:         +65-6823-2215
        Facsimile      +65-6445-3033
        Mail:          Honeywell Private Limited
                       Honeywell Building
                       17, Changi Business Park Central 1
                       Singapore 486073
        Email:         GTAC-SEA@honeywell.com
Japan
        Contact:       Honeywell Global TAC – Japan
        Facsimile      +81-3-6730-7228
        Mail:          Honeywell K.K
                       New Pier Takeshiba, South Tower Building
                       20th Floor, 1-16-1 Kaigan, Minato-ku
                       Tokyo 105-0022, Japan
        Email:         Global-TAC-JapanJA25@honeywell.com
World Wide Web
Honeywell Process Solutions website: https://www.honeywellprocess.com/
Training classes:
Honeywell holds technical training classes on Experion. These classes are
Patch Release R310.2                      Software Change Notice            iv
taught by experts in the field of process control systems. For more information
about these classes, contact your Honeywell representative, or see
http://www.automationcollege.com.
Patch Release R310.2                   Software Change Notice                     v
Symbol Definitions
The following table lists the symbols used in this document to denote certain conditions.
            Symbol                              Definition
                       ATTENTION: Identifies information that requires special
                       consideration.
                       TIP: Identifies advice or hints for the user, often in terms
                       of performing a task.
                       REFERENCE -EXTERNAL: Identifies an additional
                       source of information outside of the bookset.
                       REFERENCE - INTERNAL: Identifies an additional
                       source of information within the bookset.
                       Indicates a situation which, if not avoided, may result in
           CAUTION
                       equipment or work (data) on the system being damaged
                       or lost, or may result in the inability to properly operate
                       the process.
                       CAUTION: Indicates a potentially hazardous situation
                       which, if not avoided, may result in minor or moderate
                       injury. It may also be used to alert against unsafe
                       practices.
                       CAUTION symbol on the equipment refers the user to
                       the product manual for additional information. The
                       symbol appears next to required information in the
                       manual.
Patch Release R310.2                   Software Change Notice                               ii
            Symbol                             Definition
                       WARNING: Indicates a potentially hazardous situation,
                       which, if not avoided, could result in serious injury or
                       death.
                       WARNING symbol on the equipment refers the user to
                       the product manual for additional information. The
                       symbol appears next to required information in the
                       manual.
                       WARNING, Risk of electrical shock: Potential shock
                       hazard where HAZARDOUS LIVE voltages greater than
                       30 Vrms, 42.4 Vpeak, or 60 VDC may be accessible.
                       ESD HAZARD: Danger of an electro-static discharge to
                       which equipment may be sensitive. Observe precautions
                       for handling electrostatic sensitive devices.
                       Protective Earth (PE) terminal: Provided for connection
                       of the protective earth (green or green/yellow) supply
                       system conductor.
                       Functional earth terminal: Used for non-safety purposes
                       such as noise immunity improvement. NOTE: This
                       connection shall be bonded to Protective Earth at the
                       source of supply in accordance with national local
                       electrical code requirements.
                       Earth Ground: Functional earth connection. NOTE: This
                       connection shall be bonded to Protective Earth at the
                       source of supply in accordance with national and local
                       electrical code requirements.
                       Chassis Ground: Identifies a connection to the chassis
                       or frame of the equipment shall be bonded to Protective
                       Earth at the source of supply in accordance with national
                       and local electrical code requirements.
Patch Release R310.2                  Software Change Notice                       iii
Revision history
    Revision             Date                              Description
1                  8-July-2013   Draft
2                  17-Sep-2013   Pre-release review
3                  31-Oct-2013   Release version
Patch Release R310.2              Software Change Notice                 iv
Table of Contents
1    Introduction ....................................................................................................................... 6
    1.1     About the document ..................................................................................................... 6
    1.2     About the patch............................................................................................................ 6
     1.2.1        Problems resolved ................................................................................................ 6
     1.2.2        Issues ................................................................................................................... 9
     1.2.3        Limitations ............................................................................................................ 9
    1.3     Before you begin .........................................................................................................10
     1.3.1        Prerequisites ........................................................................................................10
     1.3.2        Obtaining and extracting the patch.......................................................................10
2    Patch installation ..............................................................................................................11
    2.1     Installing the patch interactively ..................................................................................11
    2.2     Installing the patch silently via script ...........................................................................12
     2.2.1        Common Pre-requisites .......................................................................................13
     2.2.2        UPS Components ................................................................................................14
    2.3     Migrating existing configuration ...................................................................................15
    2.4     Troubleshooting issues during installation ...................................................................15
    2.5     Installing Experion Station after UPS ..........................................................................15
    2.6     Post-Installation ..........................................................................................................15
3    Patch removal ...................................................................................................................16
Patch Release R310.2                                   Software Change Notice                                                               v
1 Introduction
1.1 About the document
The Software Change Notice describes the prerequisites, resolved PARs, applicable nodes, and
steps to install/uninstall the patch. Additionally, the SCN contains information about the change
impact and additional information for this patch. The latest version of this SCN is always
available on the Honeywell Process Solutions website.
1.2 About the patch
This patch addresses problems and offers improvements requested since the release of
Uniformance Process Studio R310.1. It can be applied to systems installed with Uniformance
Process Studio R310.1 or earlier releases. It can also be used to install Uniformance Process
Studio R310.2 on systems that have not previously had Uniformance Process Studio installed,
provided that the necessary prerequisites are available on the system. See Prerequisites for
more information.
1.2.1 Problems resolved
This patch resolves the following issues.
   PAR/ID              Subsystem                       Description of problem
1-Y57MH9,         Graphics            Experion Station functionality is negatively impacted after
1-115D31D,                            the install or uninstall of UPS Graphics.
1-
2101089716                            This issue affects UPS installations on Experion Station
                                      R400 or R410. Detailed description, Symptoms, and
                                      Resolution are available in Priority Notification PN2013-
                                      23.
                                      Changes have been made to the UPS R310.2
                                      components to minimize the chance of incompatibility
                                      between UPS and other products using HMIWeb
                                      graphics.
1-173MK5Z         Event Trend/Table   UPS R310; Local Operator/Engineers not allowed access
                                      to PHD Events
                                      Windows users now configured in the SQL Server Local
                                      Operator and Engineers groups can access event data.
1-Y1I1ML,         Excel Companion     Cannot fetch more than 65536 rows of RAW data in
140420                                Office 2007 and higher versions
139945            Event Trend         Event trend doesn’t show Icons according to the Priority
                                      of Experion.
Honeywell Process Solutions
1860 West Rose Garden Lane
Phoenix, AZ 85027 USA
   PAR/ID              Subsystem                   Description of problem
138392            Event Trend      Event Trend icons mapping for OPCAE events.
137409            Event Trend      Experion Event Markers for CEJ should be revised in
                                   Event Trend
139472            Trend            In trend legend Changes made in interval reflects in trend
                                   but doesn’t reflect in interval column
139471            Trend            In Trend Legend user cannot change Sample frequency
139466            Trend            In Trend Interval in Ribbon bar is mapped to sample
                                   frequency in Legend
1-YCSHVN,         Trend            In UPS legend columns order and selection are not
138329                             persisted
                                   Changes to order and visibility of UPS legend columns
                                   are now automatically remembered when UPS is closed
                                   and re-opened
138062            Tag Browser      User can't drag and drop tags to any application
                                   (eg:Table) for OPC datasource
138061            Navigation       Workspace item names should not contain special
                                   characters / \ : * ? " < > |
                                   These characters can cause problems with configuration
                                   files and are no longer permitted in item names
137570            Configuration    When Datasource is configured with 64 characters, Name
                                   is truncated in Tag Browser and Edit Item Details dialog
135785            General          Localization support
118860            Navigation       Workspace - optional single click to launch items.
                                   Single click to launch items can be enabled in UPS
                                   configuration, Application Defaults -> Launch workspace
                                   items on… setting.
118857            Navigation       Reordering of workspace items
                                   Workspace items can be reordered by dragging. UPS will
                                   remember the last location of items when application is
                                   opened.
118856            Navigation       Shared workspaces need different icon
118855            Navigation       Workspace - Need an option to sort the data
1-YA5VKS,         Navigation       In the Workspace windows a subfolder cannot be moved
118851                             to the root location
Honeywell Process Solutions
1860 West Rose Garden Lane
Phoenix, AZ 85027 USA
   PAR/ID              Subsystem                      Description of problem
118849            Navigation          Add tag description to workspace tooltip
118848            Navigation          Tags placed into Workspace are not in alphabetical order.
                                      Workspace items at a particular level can be sorted by
                                      selecting an item and clicking the A-Z icon in the
                                      Navigation window header.
118846            Navigation          Ability to store desktop view links as workspace items
118574            Navigation          Change of Workspace order should be persisted in
                                      Navigation
1-ILLFON          Navigation          Workspace filename truncation causes issues when a "."
                                      is used in a workspace name.
1-VOF6LF          Trend/Event Trend   Can’t go from small trend to full screen as with UPS 300
                                      or Process Trend Suites
                                      Double-clicking on a Trend or Event Trend header will
                                      now open a full size copy of the trend in a new
                                      dashboard. Note that the new trend is not linked to the
                                      original trend.
1-YXIMRP          Browser             Tag Search by Name and description (as well as by name
                                      or by description)
                                      The ability to search by Name and Description together
                                      has been reinstated. Some users may also experience
                                      improved browser performance.
1-Y9ELNZ          Trend dashboard     Multitrend layout improvements – to reduce cluttering –
                                      e.g. ability to turn axis labels on/off
                                      The Home tab now includes options in the Dashboard
                                      group to display or hide various elements of Trends and
                                      Event Trends. These options are applied to each
                                      Trend/Event Trend on the active dashboard. These
                                      options are particularly useful to reduce cluttering of
                                      multiple trends when displayed in a multi-trend
                                      arrangement.
                                      The Legend inside the Chart (“Chart Legend”) can now be
                                      enabled from the Chart ribbon menu (for a single chart) or
                                      from the Home tab (for all charts on the current
                                      dashboard).
149302            Event Trend/Table   Include TPN EVENT TYPE column to be displayed in
                                      Event applications from CEJ DATA08 column in 310.2
Honeywell Process Solutions
1860 West Rose Garden Lane
Phoenix, AZ 85027 USA
   PAR/ID              Subsystem                          Description of problem
1-11YASVM         Navigation             Uniformance Process Studio workspace file use un-
                                         optimized XML, reducing performance in UPS.
                                         Load and Save times for large workspaces are improved.
1.2.2 Issues
This patch has the following known issues.
PAR                                                     Description
1-PM1WLF                  Description: UPS is not compatible with Safeview. UPS should not be
                          installed on a system on which Safeview is used.
                          Recovery: Uninstall UPS
                          Workaround: n/a
1-1LCOOC7                 Description: Uninstalling UPS R310.2 from a Workcenter 241 system
                          may cause some Workcenter Graphics features to be broken.
                          Recovery: Re-install Workcenter 241 client
                          Workaround: n/a
1.2.3 Limitations
1.2.3.1 Patch removal
                                    [ ] Can be done manually           [ ] Must be done manually
[  ] Automatic                     during next upgrade.               before next upgrade.
1.2.3.2 Patch distribution
[ ] Not Limited                                    [ ] Limited for:
1.2.3.3 Localization
[ ] Supported                      [ ] Patch may contain strings      [ ] Needs additional
                                    in English. A Localization         localization support.
                                    version to be included in the
                                    next release.
1.2.3.4 Cumulative patch
[ ] Yes.                                           [ ] No
See Prerequisites
Honeywell Process Solutions
1860 West Rose Garden Lane
Phoenix, AZ 85027 USA
1.3 Before you begin
1.3.1 Prerequisites
Most of the pre-requisites are included with the patch installation files and are installed
automatically if needed. There are two exceptions:
       Microsoft .Net Framework 4. This software should already be available on most systems
        as it is installed with UPS R310.1. It is also available by default on Windows 7 and later
        versions of Windows. Due to the size of this file it is not included with the patch. It can be
        downloaded directly from the Microsoft website (dotNetFx40_Full_x86_x64.exe)
       Microsoft .Net Framework 3.5. This should also be available on most systems but can be
        downloaded from Microsoft website if required (dotnetfx35.exe)
1.3.2 Obtaining and extracting the patch
The patch installation files are provided in a zip archive: ups_r310.2.zip.
Download the patch from (login required):
http://downloads.honeywellprocess.com/public/Support/HiSpec/ups_r310.2.zip
Copy this file to your computer and unzip it to a convenient location.
Honeywell Process Solutions
1860 West Rose Garden Lane
Phoenix, AZ 85027 USA
2 Patch installation
The installation procedure for UPS R310.2 is similar to UPS R310.1. Refer to the UPS R310.1
Installation Guide for details. However, please note the following differences from the UPS
R310.1 installation:
   HMIWeb Graphics Runtime option is no longer installed by default on Windows 7. You need
    to explicitly select this feature using the custom installation option.
   HMIWeb Graphics Builder and Runtime option is no longer available on Window XP.
   If you install UPS R310.2 with the optional HMIWeb Graphics or HMIWeb Graphics Builder
    features, the installer will automatically install a minimal version of Experion Station and
    Display Builder. This provides the files that UPS requires for the HMIWeb Graphics options.
    This also includes the files required for the UPS Graphics Migration feature, so it is not
    necessary to install Experion Station and Display Builder before using the Experion to UPS
    Graphics Migration tool.
                              If you have an existing version of Experion Station
                              installed on your UPS system then before upgrading to
                              UPS R310.2 you must first manually uninstall the
                              existing versions of UPS and Station. You should then
                              re-install Station before installing UPS R310.2.
                              This procedure is summarized in Section 2.1 below, and
                              in detail in Priority Notification PN2013-23.
                              PN2013-23 Experion Station functionality is negatively
                              impacted after the install or uninstall of UPS Graphics
2.1 Installing the patch interactively
The UPS R310.2 installer can be used to install UPS on a clean system, or to upgrade an
earlier version of UPS.
On UPS systems that do not have Experion Station installed, it is not necessary to uninstall
UPS before installing UPS R310.2.
If Experion Station is installed on the same machine as UPS then to upgrade to UPS R310.2
you must:
    1. Manually uninstall UPS (see instructions below)
    2. Manually uninstall Experion Station
Honeywell Process Solutions
1860 West Rose Garden Lane
Phoenix, AZ 85027 USA
    3. Re-install Experion Station
    4. Install UPS R310.2
Note: Existing UPS workspace content will be preserved when uninstalling/re-installing the
application.
To manually uninstall UPS R310.1 (not required unless Experion Station has been installed on
the same system)
    1. Check that no copies of UPS or Microsoft Excel are running (otherwise a reboot may be
       required and/or removal of Excel Companion may not succeed)
    2. Open Control Panel > Programs and Features
    3. Click on the Uniformance Process Studio Item
    4. Click Change
    5. When the installation dialog appears, click Next
    6. Select Remove and click Next
    7. Click Remove
Note: you may be prompted by Windows to confirm un-installation of each of the major UPS
components individually.
To install the UPS R310.2 patch interactively:
    1. Click setup.exe from the installation files
    2. Follow the steps described in UPS R310.1 Installation Guide. If you are applying this
       patch to a system which previously had UPS R310.1 installed you will normally not need
       to make any changes to the installation defaults.
    3. If you wish to install HMIWeb Graphics Builder you must select it through the custom
       install option as per UPS R310.1.
2.2 Installing the patch silently via script
This patch supports the same level of automated installation as the UPS R310.1 installation.
The following sections provide examples of the commands to silently install the typical set of
pre-requisites plus the individual UPS components required.
Honeywell Process Solutions
1860 West Rose Garden Lane
Phoenix, AZ 85027 USA
2.2.1 Common Pre-requisites
Installation pre-requisites are included in subfolders of the ISSetupPrerequisites folder from the
installation package files. The exceptions are Microsoft .Net 3.5 and 4 Framework packages,
which can be downloaded from the Microsoft website if required.
Note that not all the provided pre-requisites are listed. Some systems may require additional
files. Contact Support if you are having trouble identifying or installing other pre-requisites.
Install components as needed, in order listed.
Component            Command                                        Notes
Microsoft .NET       > dotnetfx35.exe /q                            Not included in R310.2 patch files.
Framework 3.5                                                       Download dotnetfx35.exe from
Service pack 1                                                      Microsoft Website if required
Microsoft .Net       > dotNetFx40_Full_x86_x64.exe /q               Not included in R310.2 patch files.
Framework 4                                                         Download
                                                                    dotNetFx40_Full_x86_x64.exe from
                                                                    Microsoft Website if required
PHD Client           > msiexec.exe /i PHDClient.msi /qn
                     PIDMSID="UPSClientInstall"
                     PIDKEY="1LTK-1G9T-1ZTF-1LHI-23Y4-
                     1HBO-18CV" REBOOT=ReallySuppress
PHD Client patch     > msiexec /update
                     “Unf_310.1.1_PHDClient_x86.msp” /qn
                     REBOOT=ReallySuppress
Visual Studio        > VSTOR40_x86 /q                               Required for Uniformance Excel
Tools for Office                                                    Companion. For 32 bit system
32 bit
Visual Studio        > VSTOR40_x64 /q                               Required for Uniformance Excel
Tools for Office                                                    Companion. For 64 bit system
64 bit
Microsoft Office     > o2007pia.msi /q                              Required for Uniformance Excel
2007 Primary                                                        Companion. For Office 2007
Interop
Assemblies
Microsoft Office     > o2010pia.msi /q                              Required for Uniformance Excel
2010 Primary                                                        Companion. For Office 2010
Interop
Assemblies
Honeywell Process Solutions
1860 West Rose Garden Lane
Phoenix, AZ 85027 USA
2.2.2 UPS Components
Use the following command along with the parameters detailed in Section 2.4 of the
Uniformance Process Studio Installation Guide to install each of the UPS components.
The UPS components can be found in the Components folder of the installation files.
msiexec /i <component package>.msi [/qn /REBOOT=ReallySuppress]
[PROPERTY=VALUE]
Component            Command (example)                                    Notes
UPS Core             > msiexec /i “Uniformance Process Studio             Required for all UPS
(required)           Core.msi” /qb INSTALLDIR=”C:\Program                 installations.
                     Files\Honeywell\Uniformance\Process Studio”
                     PHD_HOST=”name of PHD host machine”
                     PHD_PORT=3100
Uniformance          > msiexec /i “Uniformance Excel                      Version of Microsoft Office
Excel Companion      Companion.msi” /qb INSTALLDIR=”C:\Program            must be specified. If using
                     Files\Honeywell\Uniformance\ExcelCompanion”
(optional)                                                                Office 2010 then use
                     OFFICE2007=1
                                                                          parameter OFFICE2010=1
Uniformance          > msiexec /i "HMIWeb Station and Display             Run both commands
Process Studio       Builder.msi" /qn REBOOT=ReallySuppress
Graphics
                     > msiexec /update
Runtime and
                     “Experion.PKS.R410.HMIWeb.Patch.3.msp" /qn
Display Builder      REBOOT=ReallySuppress
(optional)
Uniformance          > msiexec /i Uniformance Process Studio
Process Studio       Manual Input.msi /qn REBOOT=ReallySuppress
Manual Input
(optional)
Uniformance          (not required – reserved for future use)             (not required)
Process Studio
Data (not
required)
Refer to UPS R310 Installation Guide for more information on available parameters for each
component. This includes parameters to set many of the UPS core configuration options.
Honeywell Process Solutions
1860 West Rose Garden Lane
Phoenix, AZ 85027 USA
2.3 Migrating existing configuration
Configuration of UPS R310.1 will be preserved when applying this R310.2 patch.
Configuration of previous UPS versions will also be preserved as per upgrades to UPS R310.1.
2.4 Troubleshooting issues during installation
Excel Companion cannot be uninstalled or re-installed if Microsoft Excel is running. If you see a
warning regarding Microsoft Excel when uninstalling UPS please check the computer’s process
list to ensure that Excel.exe is not running before proceeding.
2.5 Installing Experion Station after UPS
                              As mentioned in Section 2, UPS R310.2 installs a
                              minimal version of HMIWeb Station and Display Builder
                              automatically if the HMIWeb Graphics or Display Builder
                              features are installed. However you will need to install a
                              standard version of Experion Station and Display Builder
                              if you want to call up or build Experion displays.
                              Before installing a full version of Experion Station on the
                              UPS 310.2 system, you should first uninstall the existing
                              version of “HMIWeb Station and Display Builder” from
                              Control Panel > Programs and Features.
2.6 Post-Installation
                              It is recommended to reboot your system after
                              installation of Uniformance Process Studio.
                              This allows for shared and memory-resident
                              components which have been upgraded during UPS
                              installation, to be re-loaded.
Honeywell Process Solutions
1860 West Rose Garden Lane
Phoenix, AZ 85027 USA
3 Patch removal
This patch cannot be removed separately – it can only be removed via a full UPS uninstall (after
which UPS can be reinstalled, or another version can be installed)
To remove the patch, uninstall the component “Uniformance Process Studio” from Control
Panel > Programs and Features.