All dielectric 160m span G.
652D 24F OPTIC FIBER CABLE
                                        SPECIFICATION
1. Introduction ADSS Fiber Cable
   The fibers are in jelly-filled loose tubes, laid up around a central nonmetallic strength member.
   The cable is water blocked, aramid yarn reinforced and PE or AT sheathed. ADSS (All Dielectric
   Self-Supporting) Cable is suspended from poles or towers in telecommunication and power
   outside plant applications.
   Features
   • The lifespan is over 30 years
   • Large span with the largest span of over 1000m
   • Can be installed without shutting off the power
   • Central strength member FRP gives high tensile strength
   • Water blocking system ensures reliable waterproof performance
   • PE or AT sheath ensures safety of cable in high voltage environment
   • All-dielectric structure and light weight provide easy installation and good electromagnetic
   resistance
   Application
   • Railways, power and telecommunication pole routes
   • Can be used in areas with high electrical field strength
   • Suitable for installation on poles and on the power distribution network
                                                 1/7
2. Optical Characteristic
Optics Specifications for G652D single mode fiber
Attenuation(dB/km)              @1310nm                             ≤0.35db/km
                                @1383nm (after hydrogen aging)      ≤0.32db/km
                                @1550nm                             ≤0.20db/km
                                @1625nm                             ≤0.24db/km
Dispersion                      @1285nm~1340nm                      -3.0~3.0ps/(nm*km)
                                @1550nm                             ≤18ps/(nm*km)
                                @1625nm                             ≤22ps/(nm*km)
Zero-Dispersion wavelength                                          1300~1324nm
Zero-Dispersion slope                                               ≤0.092ps/(nm2*km)
Mode field diameter @ 1310nm                                        9.2±0.4μm
Mode field diameter @ 1550nm                                        10.4±0.8μm
PMD                             Max. value for fiber on the reel    0.2ps/km 1/2
                                Max. Designed value for link        0.08ps/km 1/2
Cable cutoff wavelength,λ cc                                        ≤1260nm
Effective group index(Neff)@1310nm                                  1.4675
Effective group index(Neff)@1550nm                                  1.4680
Macro-bend loss(Φ60mm,100 turns)@1550nm                             ≤0.05db
Back scatter characteristic(@1310nm&1550nm)
Point discontinuity                                                         ≤0.05db
Attenuation uniformity                                                      ≤0.05db/km
Attenuation coefficient difference for bi-directional measurement           ≤0.05db/km
Geometrical characteristics
Cladding diameter                                                           125±1μm
Cladding non-circularity                                                    ≤1%
Core/cladding concentricity error                                           ≤0.4μm
Fiber diameter with coating(uncolored)                                      245±5μm
Cladding/coating concentricity error                                        ≤12.0μm
Curl                                                                        ≥4m
Mechanical characteristic
Proof test                                                                  0.69GPa
Coating strip force(typical value)                                          1.4N
Dynamic stress corrosion susceptibility parameter(typical value)            ≥20
Environmental characteristics(@1310nm&1550nm)
                                                                            ≤0.5dB/km
Temperature induced attenuation(-60~+85℃)
                                                                            ≤0.5dB/km
Dry heat induced attenuation(85±2℃,30days)
                                                                            ≤0.5dB/km
Damp heat induced attenuation(85±2℃,RH85%,30days)
                                                2/7
3. Cable Structure
                                             Cable Parameter
  Cable Type                         ADSS Cable     Fiber Count                       24 Fibers
                                   Stranded Loose
  Construction                                      Fiber Type                  Single mode G.652D
                                        Tube
  Inner/Outer Jacket Material        MDPE/HDPE      Jacket Color                        Black
  Cable Diameter                    12.0±0.2 mm Tube/Fiber/no.                             4*6
  Strength Member                        FRP        Span                                160m
  Maximum operating load                3600N       Water blocking material   Water blocking tape&yarns
 Minimum bending radius                             Minimum bending
                                         10D        radius -Dynamic                      20D
 -Static
   COLOR IDENTIFICATION OF FIBER
   The fibers shall be marked by a colored coating with 12 different colors according to EIA/TIA 598:
                                                 3/7
4. Test Requirement
  Approved by various professional optical and communication product institution , GL also conduct
  various in-house testing in its own Laboratory and Test Center. She also conduct test with special
  arrangement with the Chinese Government Ministry of Quality Supervision & Inspection Center of
  Optical Communication Products (QSICO).
  The cable is in accordance with applicable standard of cable and requirement of customer. The
  following test items are carried out according to corresponding reference.
  Routine tests of optical fiber
  Mode field diameter                            IEC 60793-1-45
  Mode field Core/clad concentricity             IEC 60793-1-20
  Cladding diameter                              IEC 60793-1-20
  Cladding non-circularity                       IEC 60793-1-20
  Attenuation coefficient                        IEC 60793-1-40
  Chromatic dispersion                           IEC 60793-1-42
  Cable cut-off wavelength                       IEC 60793-1-44
  Test for outdoor cable
   4.1 Tension Loading Test
  Test Standard                                  IEC 60794-1-2 E1
  Sample length                                  No less than 50 meters
  Load                                           Max. installation load
  Duration time                                  1 hour
  Test results                                   Additional attenuation: ≤0.05dB
                                                 No damage to outer jacket and inner elements
   4.2 Crush/Compression Test
  Test Standard                                  IEC 60794-1-2 E3
  Load                                           Crush load
  Plate size                                     100mm length
  Duration time                                  1 minute
  Test number                                    1
  Test results                                   Additional attenuation:≤0.05dB No damage to
                                                 outer jacket and inner elements
                                                4/7
  4.3 Impact Resistance Test
 Test Standard                  IEC 60794-1-2 E4
 Impact energy                  6.5J
 Radius                         13.6mm
 Impact points                  3
 Impact number                  2
 Test result                    Additional attenuation:≤0.05dB
  4.4 Repeated Bending Test
 Test Standard                  IEC 60794-1-2 E6
 Bending radius                 20 X diameter of cable
 Cycles                         25 cycles
 Test result                    Additional attenuation: ≤ 0.05dB No damage to
                                outer jacket and inner elements
  4.5 Torsion/Twist Test
Test Standard                   IEC 60794-1-2 E7
Sample length                   2m
Angles                          ±180 degree
cycles                          10
Test result                     Additional attenuation:≤0.05dB No damage to
                                outer jacket and inner elements
 4.6 Bend Test
Test Standard                   IEC 60794-1-2 E11B
Mandrel diameter                20 X diameter of cable
Turn number                     4
Number of cycles                3
Temperature
                                20℃
Test result                     No damage to outer jacket and inner elements
                               5/7
 4.7 Temperature cycling Test
Test Standard                    IEC 60794-1-2 F1
Temperature step
                                 +20℃ →-40℃ →+85℃→+20℃
                                 Transition from 0℃ to -40℃:2hours; duration at
                                 -40 ℃ :8 hours; Transition from -40 ℃       to
Time per each step
                                 +85 ℃ :4hours; duration at +85 ℃ :8 hours;
                                 Transition from +85℃ to 0℃:2hours
Cycles                           5
                                 Attenuation variation for reference value (the
Test result                      attenuation to be measured before test at
                                 +20±3℃) ≤ 0.05 dB/km
 4.8 Water penetration Test
Test Standard                    IEC 60794-1-2 F5
Height of water column           1m
Sample length                    1m
Test time                        1 hour
Test result                      No water leakage from the opposite of the
                                 sample
 4.9 Drip Test
Test Standard                   IEC 60794-1-2 E14
Sample length                   0.3m
Temperature                     70 ℃
Duration                        24 hrs
Test result                     No filling compound shall drip from tubes
                                6/7
5. Packing and Marking
  Packing
  • Each single length of cable shall be reeled on Fumigated Wooden Drum
  • Covered by plastic buffer sheet
  • Sealed by strong wooden battens
  • At least 1 m of inside end of cable will be reserved for testing.
  • Drum length: Standard drum length is 3,000m±2%;
  Drum Marking
  • Manufacturer name;
  • Manufacturing year and month
  • Roll--‐direction arrow;
  • Drum length;
  • Gross/net weight;
                                              7/7