Electric Actuator Datasheet
Your Reference: VAI-ROTORK-17-070 RFQ MOV CONOCO : Wiring Diagram
Our Reference: CSG019002-00-1
Site Reference:
Date of Quotation: 19/7/2017
Item Units
Line Number 1 2
Tag Number N/A N/A
Quantity Each 1 1
Valve Requirements Units
Type Gate Gate
Size 12 8
Class 150 150
Torque Nm 115.00 55.00
Modulating Torque Nm N/A N/A
Thrust kN N/A N/A
Modulating Thrust kN N/A N/A
Coupling Type Standard Standard
Coupling Dimension mm N/A N/A
Turns 50.00 42.25
Stroke mm N/A N/A
Operating Time secs N/A N/A
Max. Handwheel Rim Pull N 700.00 700.00
Equipment Offered Units
Actuator IQ3 25 F14 A FM IQ3 20 F14 A FM
Actuator Speed rpm 96 96
Secondary Gearbox N/A N/A
Gearbox Ratio N/A N/A
Output Flange N/A N/A
Coupling Type Thrust Base - Threaded Thrust Base - Threaded
Coupling Dimension mm 50.80 50.80
Maximum NRS Diameter mm 38.10 38.10
Maximum RS Diameter mm 50.80 50.80
Actuator Weight kg 54.03 54.03
Gearbox Weight kg
Combination Weight kg 54.03 54.03
Handwheel Type SHW THW
Handwheel Ratio 13.30 1.00
Handwheel Turns 3.33 0.25
Rim Pull N 195.50 255.75
Actuator Performance Units
Torque Nm 230.00 142.00
Modulating Torque Nm N/A N/A
Thrust kN 100.00 100.00
Modulating Thrust kN N/A N/A
Resultant Thrust kN N/A N/A
Output Speed rpm 96.00 96.00
Linear Speed mm/sec N/A N/A
Operating Time secs 31.25 26.41
Requested Safety Factors
Torque 1.30 1.30
Modulating Torque 1.00 1.00
Thrust 1.30 1.30
Modulating Thrust 1.00 1.00
Calculated Safety Factors
Torque 2.00 2.58
Modulating Torque N/A N/A
Thrust N/A N/A
Modulating Thrust N/A N/A
Electrical Data
Voltage V 380 380
Phase Ø 3 3
Frequency Hz 50 Hz 50 Hz
Starting current A 26.7 15.9
Starting power factor 0.8 0.9
Rated load current A 7 4.7
Current at average load A 3.6 3
Power factor at average load 0.7 0.6
Motor power at average load kW 1.7 1.2
Number of poles of motor 2 4