IRIS INSPECTION REPORT
TUBE MAPPING
HYDROGEN COOLER TAG. NO. E-610 B
NO REJECTED TUBES
Tubes
R
o Top of Vessel
w
s
1 Row 1, Tube 1 9
2 12
3 13
4 14
5 15
6 15
7 17
8 18
9 19
10 20
11 17
12 19 14
13 19 15
14 18 14
15 17 13
16 16 12
17 15 9
14
13
9
9
Total Accepted Tubes : 133 Rejected Tubes : 0.00
Legend : 0 % - 20 % 41 % - 60 % Holle (100%)
21 % - 40 % 61 % - 80 %
Inspected by, Reviewed by, Approved by,
PT. SUCOFINDO PT. SULFINDO ADI USAHA
TOHIRIN
IRIS Inspector (ASNT Lv. II)
IRIS INSPECTION REPORT
TUBE MAPPING
HYDROGEN COOLER TAG. NO. E-610 B
NO REJECTED TUBES
Tubes
R
o Top of Vessel
w
s
1 Row 1, Tube 1 9
2 12
3 13
4 14
5 15
6 14
7 17
8 18
9 17
10 18
11 17
12 14
13 15
14 14
15 13
16 12
17 9
Total Accepted Tubes : 241 Rejected Tubes : 0.00
Legend : 0%-7% 21 % - 40 % Holle (100%)
8 % - 20 % 41 % - 60 % 61 % - 80 %
Inspected by, Reviewed by, Approved by,
PT. SUCOFINDO PT. SULFINDO ADI USAHA
TOHIRIN
IRIS Inspector (ASNT Lv. II)
IRIS INSPECTION REPORT
TUBE MAPPING
HYDROGEN COOLER TAG. NO. E-610 A
NO REJECTED TUBES
Tubes
R
o
w
s Top of Vessel
1 Row 1, Tube 1 9
2 12
3 15
4 16
5 17
6 18
7 17
8 18
9 17
10 18
11 17
12 18
13 17
14 18
15 17
16 16
17 15
18 12
19 7
Total Accepted Tubes : 294 Rejected Tubes : 0.00
Legend : 0%-7% 21 % - 40 % Holle (100%)
8 % - 20 % 41 % - 60 % 61 % - 80 %
Inspected by, Reviewed by, Approved by,
PT. SUCOFINDO PT. SULFINDO ADI USAHA
TOHIRIN
IRIS Inspector (ASNT Lv. II)
IRIS INSPECTION REPORT
TUBE MAPPING
HEAT EXCHANGER TAG. NO. E-350
NO REJECTED TU
Tubes
R
o
w Top of Vessel
s
1 Row 1, Tube 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
Total Accepted Tubes : 900 Rejected Tubes : 0.00
Legend : 0%-7% 21 % - 40 % Holle (100%)
8 % - 20 % 41 % - 60 % 61 % - 80 %
Inspected by, Reviewed by, Approved by
PT. SUCOFINDO PT. SULFINDO ADI
TOHIRIN
IRIS Inspector (ASNT Lv. II)
NO REJECTED TUBES
8
14
17
18
19
24
25
26
27
28
27
30
31
30
31
32
31
32
32
31
32
31
30
31
30
27
28
27
26
25
24
19
18
17
14
8
Approved by,
ULFINDO ADI USAHA