0% found this document useful (0 votes)
290 views7 pages

Dso5000p Datasheet

This document provides specifications for three digital storage oscilloscopes: the DSO5202P, DSO5102P, and DSO5072P. Key specifications include bandwidths of 200MHz, 100MHz, and 70MHz respectively; sample rates up to 1GS/s; trigger types including edge, pulse, and video; and features such as FFT and auto measurements. The oscilloscopes are designed for applications like design and debugging, education and training, manufacturing testing, and service/repair.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
290 views7 pages

Dso5000p Datasheet

This document provides specifications for three digital storage oscilloscopes: the DSO5202P, DSO5102P, and DSO5072P. Key specifications include bandwidths of 200MHz, 100MHz, and 70MHz respectively; sample rates up to 1GS/s; trigger types including edge, pulse, and video; and features such as FFT and auto measurements. The oscilloscopes are designed for applications like design and debugging, education and training, manufacturing testing, and service/repair.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Date Sheet

Digital Storage Oscilloscope


DSO5202P DSO5102P DSO5072P

Features & Benefits Ease-of-Use Feature


200/100/70MHz Bandwidths Five math functions, +, -, *, /, and FFT functions.
1GSa/s Real Time Sample Rate 32 automatic measurements and track
Trigger mode: Edge, Pulse Width, Video, Slop, measurement via cursor automatically.
Overtime, Alternative trigger etc. Large (7.0-inch) color display,WVGA(800x480)
Provides software for PC real-time analysis Support U disk and local files storage.
Pass/Fail Function enables to output testing results
Built in Bode diagram Assistant.
Applications
Design and Debug
Education and training
Manufacturing Test and Quality Control
Service and Repair
Electronic Circuit Designing and Testing.

1 www.hantek.com
Digital Storage Oscilloscope ---- DSO5000P Series

FFT Dual-window Mode (Full Screen)

Autoset Math: CH1+CH2

Troubleshooting
Performance You Need at a Price You Can Afford
If the oscilloscope is no display of waveforms on the screen when the
The DSO5000B Series Digital Storage Oscilloscope provides you
oscilloscope is turned on, follow these steps:
I. Check the probe to assure its proper connection to the input BNC; with affordable performance in a compact design. Packed with stan-
II. Check the channel switch (such as CH1, CH2 menu buttons) to dard features-including USB connectivity, 32 automated measurem-
make sure it has been turned on; ents, limit testing, data loading, and context-sensitive make the
III. Check the input signal to verify it has been connected to the probe instruments help you get more done in less time. Digital Precision for
correctly;
Accurate Measurements With up to 200MHz bandwidth and 1GS/s
IV. Affirm that all measured circuits have signals to output;
maximum sample rate, no other digital storage oscilloscope offers as
V. Turn up the magnitude for DC signals with large magnitude;
much bandwidth and sample rate for the price. Hantek provides real-
VI. In addition, you may press the Auto Measure button to perform an
automatic detection of signals at first. time sampling with a minimum of 10X oversampling on all channels,
all the time to accurately capture your signals.
Designed to Make Your Work Easy
The DSO Series oscilloscopes are designed with the ease of use and Easy PC Connectivity
familiar operation you have come to expect from Hantek Easily capture, save, and analyze measurements results by connec-
ting to your PC with the rear-panel USB device port. Simply pull
Help When You Need It, Where You Need It screen images and waveform data into the stand-alone desktop
The built-in Help menu provides you with important information on application.
your oscilloscope’s features and functions. Help is provided in the
same languages as the user interface.

2 www.hantek.com
Digital Storage Oscilloscope ---- DSO5000P Series

Characteristics
Acquisition
Sample Rate Real-Time Sample: 1GS/s;
Equivalent Sample: 25GS/s
Acquisition Modes
Normal Normal data only
Peak Detect High-frequency and randon glith capture
Average Wavefom Average, selectable 4,8,16,32,64,128
Inputs
Input Coupling AC, DC, GND
Input Impendance 1MΩ±2% ‖20pF±3pF
Probe Attenuation 1X, 10X
Supported Probe
1X, 10X, 100X, 1000X
Attenuation Factor
CAT I and CAT II: 300VRMS (10×); Installation Category III: 150VRMS (1×);
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz and above.
Max. Input Voltage For non-sinusoidal waveforms, peak value must be less than 450V.
Excursion above 300V should be of less than 100ms duration.
RMS signal level including all DC components removed through AC coupling must be limited
to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range 500MS/s--1GS/s
Waveform Interpolation (sin x)/x
Record Length 24K
2ns/div to 40s/div, in a 2, 4, 8 sequence, DSO5202P
SEC/DIV Range
4ns/div to 40s/div, in a 2, 4, 8 sequence, DSO5102P/DSO5072P
Sample Rate and
±50ppm(at over any ≥1ms time interval)
Delay Time Accuracy
DSO5202P:
2ns/div to 10ns/div; (-4div x s/div) to 20ms;
Position Range DSO5102P/DSO5072P:
20ns/div to 80us/div; (-8div x s/div) to 40ms;
200us/div to 40s/div; (-8div x s/div) to 400s;

Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);


Delta Time Measurement
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Accuracy (Full Bandwidth)
Sample interval = s/div ÷ 200
Vertical
Vertical Resolution 8-bit resolution, all channel sampled simultaneously
Volts/Div Range 2mV/div~10V/div
2mV/div to 200mV/div; ±2V;
Position Range
200mV/div to 5V/div; ±50V
DSO5202P: 200MHz;
Bandwidth DSO5102P: 100MHz;
DSO5072P: 60MHz;
DSO5202P: 1.8ns;
Rise time at BNC(typical) DSO5102P: 3.5ns;
DSO5072P: 5ns;
Analog Bandwidth in 2mV/div to 20mV/div, ±400mV;
Normal and Average Modes 50mV/div to 200mV/div, ±2V;
at BNC or with probe, 500mV/div to 2V/div, ±40V;
DC Coupled 5V/div, ±50V
Math +, -, *, /, FFT
FFT Windows: Hanning、Flatop、Rectamgular、Bartlett、Blackman;
1024 sample point;
Bandwidth Limit 20MHz

3 www.hantek.com
Digital Storage Oscilloscope ---- DSO5000P Series

Low Frequency Response (-3db) ≤10Hz at BNC


±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
DC Gain Accuracy
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only
DC Measurement Accuracy, 10mV/div or greater is selected; When vertical displacement is not zero, and
Average Acquisition Mode N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for
settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability, Delta volts between any two averages of ≥16 waveforms acquired under same setup and
Average Acquisition Mode ambient conditions
Trigger
Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes Auto, Normal
Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject
DC(CH1,CH2):
1div from DC to 10MHz;1.5div from 10MHz to 100MHz; 2div from 100MHz to 200MHz;
DC(EXT):
200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DC(EXT/5):
1V from DC to 100MHz;1.75V from 100MHz to 200MHz;
Trigger Sensitivity AC:
(Edge Trigger Type) Attenuates signals below 10Hz
HF Reject:
Attenuates signals above 80kHz
LF Reject:
Same as the DC-coupled limits for frequencies above 150KHz;
Attenuates signals below 150KHz
CH1/CH2: ±8 divisions from center of screen;
Trigger Level Range EXT: ±1.2V;
EXT/5:±6V
Trigger Level Accuracy(typical) CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
Accuracy is for signals having EXT: ± (6% of setting + 40mV);
rise and fall times ≥20ns EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical) Operates with input signals ≥50Hz
Trigger Holdoff range 100ns-10s
Video Trigger
CH1, CH2: Peak-to-peak amplitude of 2 divisions;
Video Trigger Type EXT: 400mV;
EXT/5: 2V
Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Signal Formats and Field Rates
Line range: 1-525(NTSC), 1-625(PAL/SECAM)
Holdoff Range 100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge.
Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as
Pulse Width Trigger Point the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues
longer than the time specified as the Pulse Width
Pulse Width Range 20ns ~ 10s
Overtime Trigger
Over Time Mode Rising edge or Falling edge
Time Range 20ns ~ 10s

4 www.hantek.com
Digital Storage Oscilloscope ---- DSO5000P Series

Slope Trigger
Slope Trigger Mode Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Slope Trigger Point Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range 20ns ~ 10s
Alternative Trigger
Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution 6 digits
Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range AC coupled, from 4Hz minimum to rated bandwidth
Pulse Width or Edge Trigger modes: all available trigger sources;
The Frequency Counter measures trigger source at all times, including when the oscilloscope
acquisition pauses due to changes in the run status, or acquisition of a single shot event has
completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s
Signal Source
measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse
train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
Measurement
Manual: Voltage difference between cursors: △V;
Cursor Measurement Time difference between cursors: △T;
Reciprocal of △T in Hertz (1/ΔT);
Tracing: The voltage and time at a waveform point
Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time,
+Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid,
Auto Measuerment
Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH,
FRF, FFR, LRR, LRF, LFR, LFF
Display
Display Type 7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution 800 horizontal by 480 vertical pixels
Display Contrast Adjustable (16 gears) with the progress bar
Probe Compensator Output
Output Voltage (typical) About 5Vpp into ≥1MΩ load
Frequency(typical) 1KHz
Power Supply
100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ
Supply Voltage
120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ
Power Consumption <30W
Fuse 2A, T rating, 250V
Environmental
Operating: 32℉ to 122℉ (0℃ to 50℃);
Temperature
Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)
Cooling Method Convection
+104℉ or below (+40℃ or below): ≤90% relative humidity;
Humidity
106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity
Operating: Below 3,000m (10,000 feet);
Altitude
Nonoperaring: Below 15,000m(50,000 feet)
Mechanical
Packing: Length 385mm; Width 200mm; Height 245mm
Size
Without Packing: Length 313mm; Width 108mm; Height 142mm
Weight 2.08KG(without Packing; 3.5KG(with Packing)

5 www.hantek.com
Digital Storage Oscilloscope ---- DSO5000P Series

Font Panel Features

5 6
7 8

1 2

1 USB Host Port -- Conveniently use your USB flash drive to


6 Autoset -- Simplify setup with smart Autoset function which
store your personal oscilloscope setups, screen shots,and
identifies the type of waveform, asjusts controls to produce a
waveform data of later use, Also ues the USB host port to
usable display of input signal, and allows you to select how
easily update your instrument firmware.
the waveform should be presented.This function can be used
to adjust the horizontal and vertical scales of the oscilloscope
2 Math Menu -- Easy and precise On-board Analysis, FFT and
automatically and set the trigger coupling, type, position,
waveform add, subtract, and multiply math functions come
slope, level and mode, etc., to acquire a stable waveform
standard on all models. FFT function displays frequency do-
display. Automatically set the oscilloscope controls to gener-
main spectrums for fast harmonic distortion analysis or other
ate a usable display of the input signals.
frequency based analysis.

7 Help -- Help system with topics covering all of its features.


3 Probe Check -- Quickly verity that your probe is calibrated Built in context-sensitive help further eases the operation by
and operating properly providing indexed and linked topics that allow you to selecti-
vely learn about the operation of various oscilloscope featur-
4 Triggers -- Quickly capture your event of interest with adva- es and functions.
nced triggers including Pulse Width, Edge, slope, Overtime
and line selectable video triggers. 8 Save to USB -- Save all displays on the screen to a USB
device, just like the screen capturing function of a computer.

5 F7 Button -- Push this button in single-window mode to


switch between dotted line display and cross display. Push
it in dual-window mode to perform auto cruise.

6 www.hantek.com
Digital Storage Oscilloscope ---- DSO5000P Series

Rear Panel Features

10

9 USB Device Port Combined with PC -- Easily communicate 10 Integrated Handle -- Easily carry your light instruments
with other instruments, peripherals or system via usb. The from a place to another.
USB port allows you full programmable controls for automated
measurements and remote display and archiving.

Standard Accessories

X1, X10 two passive probes. The passive probes have a 6MHz bandwidth (rated 100Vrms CAT III)
Probe when the switch is in the X1 position, and a maximum bandwidth (rated 300Vrms CAT II) when the
switch is in the X10 position. Each probe consists of all necessary fittings.
A power cord special for this product. In addition to the power cord shipped with your instrument,
Power Cord
you may purchase another one certified for the country of use.
A warranty card. When there appears something wrong with the product, it can be returned for
Warranty Card
repair under warranty.
A USB A-B line, used to connect external devices with USB-B interface like a printer or to
USB Line
establish communications between PC and the oscilloscope.
A software installation CD. It contains the user manual of DSO5000B(MV), giving particular
CD
descriptions on the DSO5000B(MV) series oscilloscopes.

Qingdao Hantek Electronic Co., Ltd