0% found this document useful (0 votes)
86 views4 pages

At

The document discusses medium voltage potential transformer fuses rated from 2.4kV to 7.2kV. It provides information on features, benefits, applications, dimensions, ratings and melting time-current data for different fuse models.

Uploaded by

Marcel Baque
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
86 views4 pages

At

The document discusses medium voltage potential transformer fuses rated from 2.4kV to 7.2kV. It provides information on features, benefits, applications, dimensions, ratings and melting time-current data for different fuse models.

Uploaded by

Marcel Baque
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Medium voltage fuses

Medium voltage fuses


American Fuses
Potential Transformer Fuses (E-Rated)
2.4kV to 7.2 kV - A240T / A480T / A500 / A072T

POTENTIAL TRANSFORMER FUSES


Ferraz Shawmut E-rated PT fuses are current limiting fuses
with high interrupting rating, used for primary winding-
protection of potential transformers. They are small
dimension, ferrule-type fuses and mounted in standard
clips. Ratings are 1/2E to 5E at 2.4, 4.8, and 5.0 kV at
7,2kV rating are 1/2E to 3E
Features /Benefits Highlights
• Current limiting protection for transformers • E-Rated
• Ferrule mounting for ease of installation in • Current-Limiting
standard clips
• Compact size saves valuable mounting space Applications
• Fiberglass body provides dimensional stability in Primary protection for 2.4, 4.8, 5.0 or 7.2kV
harsh industrial environments potential transformer
• Metal embossed catalog number for lasting
identification

Ratings
A240T A500T
AC: 1/2E to 5E AC: 1/2E to 5E
2400VAC, 50kA I.R. Sym. 5000VAC, 50kA I.R. Sym.
A48OT A720T
AC: 1/2E to 5E AC: 1E to 3E
4800VAC, 50kA I.R. Sym. 7200VAC, 50kA I.R. Sym.

Dimensions
Catalog Number Dimensions - inches Fuse Clips*
Prefix A B C Centers Cat. NO.
A240T 4-5/8 13/16 5/8 4.0” CO8917P
A480T 5-5/8 13/16 5/8 5.0” CO8917P
A500T 5-5/8 1 9/16 5.0” -
A720T 9-1/2 13/16 5/8 8.88” CO8917P

Standard Fuse Ampere Ratings, Catalog and Reference Numbers


E-Rating Catalog Number Reference Number
2400V 4800V 5000V 7200V 2400V 4800V 5000V 7200V
1/2E A240T1/2E A480T1/2E A500T1/2E-1 A720T1/2E-1 P212855 C215397 S218470 Z203710
1E A240T1E A480T1E A500T1E-1 A720T1E-1 P213867 D215904 D219515 E211305
2E A240T2E A480T2E A500T2E-1 A720T2E-1 A214383 H216414 X221970 P211820
3E - A480T3E A500T3E-1 A720T3E-1 - Q216927 G222715 C212338
4E - A480T4E A500T4E-1 - - C217444 W223234 -
5E A240T5E A480T5E A500T5E-1 - Y214887 M217959 W201568 -

MV71 12/04
This datasheet has been downloaded from http://www.digchip.com at this page
Medium
Medium voltagevoltage
fuses fuses
American Fuses
Potential Transformer Fuses (E-Rated)
2.4kV to 7.2 kV - A240T / A480T / A500 / A072T

A240T1/2E to 5E
MELTING TIME – CURRENT DATA - PT FUSES - 2400V

A480T1/2E to 5E
MELTING TIME – CURRENT DATA - PT FUSES - 4800V
TIME IN SECONDS

TIME IN SECONDS

CURRENT IN AMPERES

CURRENT IN AMPERES

12/04 MV72
Medium voltage fuses
Medium voltage fuses
American Fuses
Potential Transformer Fuses (E-Rated)
2.4kV to 7.2 kV - A240T / A480T / A500 / A072T

A500T1/2E-1 to 5E-1 Melting Time


Current Data - PT Fuses - 5000V

A720T1E-1 and A720T2E-1


Melting Time – Current Data
TIME IN SECONDS

PT Fuses - 7200V
TIME IN SECONDS

CURRENT IN AMPERES

CURRENT IN AMPERES

MV73 12/04
Medium
Medium voltagevoltage
fuses fuses

12/04 MV74

You might also like