The PRK 18 is a retro-reflective photoelectric sensor that uses polarization filtering to detect transparent objects like glass, plastic, and foil. It has an operating range of up to 3 meters and allows the user to finely adjust the sensitivity. The autocollimation principle ensures reliable detection over the full operating range. LED indicators show the operating point and switching status.

Uploaded by

peterkrones
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
739 views2 pages

PRK18 4 DL.4

The PRK 18 is a retro-reflective photoelectric sensor that uses polarization filtering to detect transparent objects like glass, plastic, and foil. It has an operating range of up to 3 meters and allows the user to finely adjust the sensitivity. The autocollimation principle ensures reliable detection over the full operating range. LED indicators show the operating point and switching status.

Uploaded by

peterkrones
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Leuze electronic

PRK 18 Retro-reflective photoelectric sensors with polarisation filter

Dimensioned drawing

0 … 3m

10 - 30 V
DC

l Retro-reflective photoelectric sensor for


safe detection of transparent media
(e.g. clear glass, PE, foil)
l User controlled sensitivity adjustment with
high resolution allows detection of transpar-
ent objects
l The autocollimation principle used ensures
that the device functions reliably over the
entire range (0 … max.)
A Indicator diodes
B Sensitivity adjustment
C Optical axis

Electrical connection
ISO
9001 IP 67
We reserve the right to make changes • 18_b03e.fm

IEC 60947... IEC 60947...

Accessories:
(available separately)
l Mounting system (BT 95)
l M12 connectors (KD …)
l M8 connectors (KD …)
l Ready-made cables (KB …)
l Reflectors
l Reflective tapes

Leuze electronic GmbH + Co. Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730 PRK 18/2/4 DL.4 - 02
http://www.leuze.de RK 18/4 DL.45 - 02
Leuze electronic
PRK 18

Specifications Tables
Optical data PRK 18/4 DL.4
RK 18/4 DL.45
Typ. operating range limit (TK(S) 100x100) 1) 0 … 3m
Operating range 2) see table Reflectors Operating
Recommended reflector MTK(S) 50x50 range
Light source LED (modulated light)
1 TK(S) 100x100 0 … 2.4 m
Wavelength 660nm (visible red light, polarised)
2 MTK(S) 50x50 0 … 2.0 m
Timing 3 TK(S) 30x50 0 … 0.8 m
Switching frequency 1500Hz 4 TK(S) 20x40 0 … 0.8 m
Response time 0.333ms 5 Tape 2 100x100 0 … 0.4 m
Delay before start-up ˆ100ms
Electrical data 1 0 2.4 3.0
Operating voltage UB 3) 10 … 30VDC (incl. residual ripple) 2 0 2.0 2.5
Residual ripple ˆ 15% of UB 3 0 0.8 1.0
Bias current ˆ 35mA 4 0 0.8 1.0
Switching output PNP transistor 5 0 0.4 0.6
Function characteristics dark or light switching (by reversing the polarity of UB)
Signal voltage high/low ˜ (UB -2V)/ˆ 2V Operating range [m] *)
Output current max. 100mA Typ. operating range limit [m] *)
Sensitivity adjustable with 12-turn potentiometer
*) For sensitivity set to operating point 3
Indicators
LED yellow switching output
LED green, slowly flashing operating point 1 clear glass – transition from quickly
flashing to slowly flashing
Diagrams
LED green, quickly flashing operating point 2 coloured glass – transition from cont. Typ. object gap
(MTKS 50x50 at 400mm)
illuminated to quickly flashing
10
LED green, continuous light operating point 3 non transparent media – continuous 9 A

Gap size y [mm]


light 8 B
7 C
Mechanical data 6
5
Housing diecast zinc 4
Optics glass 3
2
Weight 150g 1
Connection type M12 connector, 4-pin, stainless steel 0
0 100 200 300 400
Distance x [mm]
Environmental data
Ambient temp. (operation/storage) -25°C … +55°C/-40°C … +70°C A Operating point 1
Protective circuit 4) 2, 3 B Operating point 2
VDE safety class III C Operating point 3
Protection class IP 67
Standards applied IEC 60947-5-2
1) Typ. operating range limit: max. attainable range without performance reserve y
2) Operating range: recommended range with performance reserve
3) Functional extra/low voltage with reliable disconnection or protective extra-low voltage (VDE 0100/T 410) x
4) 2=polarity reversal protection, 3=short-circuit protection for all outputs

Remarks
Objects Adjustment
(indicator
LED yellow)
Clear glass, operating
PE, foil point 1

Order guide
Selection table
Part No. 500 80153

Part No. 500 81153

Part No. 500 81364

Coloured operating
PRK 18/4 DL.4

PRK 18/2 DL.4

RK 18/4 DL.45

glass point 2
Order codeÍ

Equipment Ï
Application transparent media l l l Opaque operating
objects point 3
foils > 5µm l
Switching output PNP transistor l l
NPN transistor l
Switching light l l l l The light spot may not
dark l l l exceed the reflector.
LED sensor back l l l l RK 18/4 DL.45
Adjustment 12-turn (sensor back) l l l The sensor has to be
Features polarisation filter l l mounted approx. 5° angu-
lar towards the object.
l Preferably use
MTK(S) 50x50.

PRK 18/2/4 DL.4 - 02 0202


RK 18/4 DL.45 - 02