Main Block

The document provides structural soundness certificates for Mohamed Sathak Engineering College buildings located in Ramnad District, Tamil Nadu. It certifies that the main block building, which is ground floor plus two stories, was inspected on July 2, 2015 and found to be structurally sound. The certificate is valid for three years until June 2018 provided no alterations are made without permission and the building remains in good condition.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
285 views4 pages

Main Block

The document provides structural soundness certificates for Mohamed Sathak Engineering College buildings located in Ramnad District, Tamil Nadu. It certifies that the main block building, which is ground floor plus two stories, was inspected on July 2, 2015 and found to be structurally sound. The certificate is valid for three years until June 2018 provided no alterations are made without permission and the building remains in good condition.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 4

FORM - A

CERTIFICATE OF STRUCTURAL SOUNDNESS

I certify that I have inspected the MOHAMED SATHAK ENGINEERING


COLLEGE, on 02.07.2015, that is located at SURVEY NOS :329, 330, 331/2, 331/3, ECR
ROAD IN MAYAKULAM VILLAGE RAMNAD DITRICT , PIN– 623 806
The following buildings were inspected by me,

1) MAIN BLOCK - GROUND FLOOR +2 - R.C.C ROOFING ONE BUILDING ONLY.

The certificate covers the above mentioned buildings only and does not include any
other structures or buildings. I found that there is no visible defects noticed in the buildings and it
is structurally sound to run the College.
This Certificate does not include any eventualities caused by Natural Calamities.
Periodical repairs and renovations will be carried out to the entire buildings then and there
whenever necessary.
This Certificate does not include any thatched sheds. If any Alteration/ Deviation should
not be carried out to any of the blocks without prior permission from the competent authority.
Further if any above mentioned aspects were found at a later date after issue of this Certificate
/License, this certificate gets invalid.

.
Place: KILAKARAI – 623 806. Signature of the Engineer
Date: 02.07.2015

…… (2)
STRUCTURAL SOUNDNESS CERTIFICATE RELATING TO COLLEGE
STATEMENT ACCOMPANYING FORM 'A'
1. Door Number of the Building : MOHAMED SATHAK ENGINEERING COLLEGE
(Main Block),
2. Location Street No. Ward No. : EAST COAST ROAD, MAYAKULAM VILLAGE,
RAMNAD DISTRICT – 623 806
3. Name of place i.e. Corporation Municipality/ Panchayat : EAST COAST ROAD, MAYAKULAM VILLAGE,
/ Panchayat Union/Township Contonment RAMNAD DISTRICT – 623 806
4. Year of Construction : Main Block - G.F+3 - 2015
5. Approximate Cost of construction : 1.15 CRORE
6. Purpose for which the building is used : For Running College
7. Purpose for which the building has hither to been used. : EDUCATIONAL INSTITUTION
8. Details of construction of the building (particulars) of
the foundation, soil, specification of the various parts
as under:-
a) Foundation R.C.C , TRAPEZOIDAL SIZE AS 3.05 X 3.05 BED
THICK=1.5 CM PCC 1:4:8
b) Basement 30 CM DEPTH, FOUNDATION BED ON GRAVEL
c) Superstructure FRAME STRUCTURE (COLUMN SIZE AS 0.3 X 03 M ) PLINT
BEAM 0.3M DEPTH
d) Floor and roof Flooring TYPE: PCC 1:5:10, MARBLE COVERED ROOT
TYPE 100MM THICK RCC 1:1:5:3
9. Period for which license is required From 01.07.2015 to 01.06.2018.
10. Number of persons to be accommodated About 500Nos

Signature of the Chairman Signature of the Engineer

…… (3)
FORM - B
STATEMENT OF ACCOMPANY THE CERTIFICATE OF
STRUCTURAL SOUNDNESS
Form of certificate of structural soundness under sub section (4) of section of 4 of the Madras
Public Buildings (Licensing Act 1963 Madras Act 13 of 1965 referred to in rule 4 of the Madras Public
Building (Licensing) rules 1977.
Certify that I have inspected the building mentioned in the statement below and I have satisfied
myself the building is structural sound to be used as a public building for the purpose note in the
statement. The structural soundness of the building has been verified taking into account the loading as
per the latest Indian standard 875.
Value of Short description of
Location of the building door No. street Age of the
the No. of Storey’s structure steel RCC framed
name and name of the place Building
Building or load bearing masonry.
1 2 3 4 5
MOHAMED SATHAK ENGINEERING
COLLEGE (Main Block), G. F + 2 (G+3)
G.F+3 - 29 Yrs -
EAST COAST ROAD, MAYAKULAM only
VILLAGE, RAMNAD DISTRICT – 623 806

Purpose for which the The period for which the building No. of persons to
Remarks
building is certified for use will be structurally Sound be accommodated
6 7 8 9

License may be given for the period


For Running college of 2 years from 02.07.2015 To About 500 Nos. NIL.
01.06.2018.

Signature of the Chairman Signature of the Engineer.

…… (4)
FORM - C

FORM OF CERTIFICATE OF STRUCTURAL SOUNDNESS UNDER SUBSECTION (4) OF SECTION 4 OF THE


TAMIL NADU PUBLIC BUILDING (LICENSING ACT 1965 (TAMIL NADU ACT 1 OF 1965) REFERRED TO IN
RULE OF THE TAMIL NADU PUBLIC (LICENSING) RULES 1966.

I certify that I have inspected the building mentioned in the statement and furnished below its
salient technical features.

1. FOUNDATION:
I) Depth below ground level : 1.83M.
ii) Nature of soil set out in the foundation. : GRAVEL
iii) Pressure at foundation : UPWARD PRESSURE:100 KN / M2
iv) Probable safe bearing capacity Of the foundation : 210 KN / M2

2. SUPERSTRUCTURE:
I) Maximum stress in most critical Sections of masonry and concrete. : 20N / MM2
ii) Nature of masonry and concrete and its safe permissible stress. : 20N / MM2

The structural soundness of the building has been verified by me with reference to ISI loading
standards 895 (latest version) and other relevant Indian Standard code of practices I declare that the
building is structurally sound to be used as a public building for the purpose noted in the statement.
A license may be granted for the period from 02.07.2015 to 01.06.2018.

Signature of the Chairman Signature of the Engineer.