DE28 Differential Pressure Transmitter: Block Schematic Diagram

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
127 views4 pages

DE28 Differential Pressure Transmitter: Block Schematic Diagram

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Contact: EK Engineering (www.ekeindia.

com)
Email: india.eke@gmail.com
Mob: +91-9680966000

DE28 Differential Pressure Transmitter

Application
Measuring Transmitter for overpressu-
re, partial vacuum and differential pres-
sure of liquid and aerial media. Ranges:
0-0.4 up to 0-6 bar. This series of trans-
mitter is suitable for various measuring
applications in the field of industrial and
sanitary techniques.

Typical applications:
• Measurement of differential pres-
sure between forward and return
flow in heating systems
• Monitoring of filters, blowers and
compressors

Main Features A centre-mounted tappet transfers the motion of the


• Overpressure protection diaphragm system to the core of an inductive displace-
• Maintenance-free due to inductive ment transducer. The subsequent converter circuit con-
movement verts this motion into an electrical output signal 0(4) - 20
• Multiple applications mA linear, 3-wire connection. The transmitter is reverse
• rugged design battery and short circuit protected.

Construction and Operation


This transmitter is based on a rugged
Block Schematic Diagram
and uncomplicated diaphragm move-
ment. The operating principle of the sy-
stem is identical for all applications of
this type. In a state of equilibrium, the 1 pressure
forces of the springs on both sides of the chamber
diaphragm are balanced. 2 inductive
displacement
The pressure or differential pressure to transducer
be measured creates an unbalanced 3 measuring springs
4 measuring
force of the springs for the measuring
diaphragm
range until a new equilibrium is reached.
Contact: EK Engineering (www.ekeindia.com)
Email: india.eke@gmail.com
Mob: +91-9680966000

Specifications

General
Measuring ranges 0-0.4 0-0.6 0-1 0-1.6 0-2.5 0-4 0-6 bar
Nominal pressure 16 bar
Max. pressure load one-sided overpressure protected up to nominal pressure,
on (+) and (-) side of diaphragm, partial vacuum protected
Permissible ambient temperature 0 up to +70 C
Max. storage temperature 70 C
Protection class IP54 per DIN EN 60529
Linearity 2% FS
Hysteresis 1% FS
Electrical
Electrical connection 3-wire
Operating voltage 24 V DC / AC 24 V DC / AC
range 15...30 V DC range 15...30 V DC
20...30 V AC 20...28 V AC
Output signal 0...20 mA 0...10 V
4...20 mA
Load 380 for all 2K
operating voltages
Connections
Pressure connection female thread G 1/8
cutting ring connection (brass) for 6mm tube
cutting ring connection (brass) for 8mm tube
Electrical connection fixed numbered cable, prewired
Materials
Case material polycarbonate
Pressure chamber brass

Measuring diaphragm NBR / Viton®


Mounting
Mounting position upright, pressure ports downward

Measuring transmitter is reverse battery and short circuit protected.

Electrical Connection

7MKREP



Contact: EK Engineering (www.ekeindia.com)
Email: india.eke@gmail.com
Mob: +91-9680966000

Dimensions (all units in mm unless stated otherwise)

cutting ring connection for ø 6 mm M12x1.5 cable gland


Contact: EK Engineering (www.ekeindia.com)
Email: india.eke@gmail.com
Mob: +91-9680966000

Ordering Code

Differential Pressure Transmitter DE28 L 0 0 0 0

Measuring Range
0 ... 400 mbar ....................................................................> 8 3
0 ... 0.6 bar ....................................................................> 0 1
0 ... 1 bar ....................................................................> 0 2
0 ... 1.6 bar ....................................................................> 0 3
0 ... 2.5 bar ....................................................................> 0 4
0 ... 4 bar ....................................................................> 0 5
0 ... 6 bar ....................................................................> 0 6

Pressure Chamber / Gaskets


pressure chamber, measuring diaphragm, gasket: Ms/NBR.............> M
pressure chamber, measuring diaphragm, gasket: Ms/Viton® ..........> N

Pressure Connection
Female thread G 1/8 ............................................................................... > 0 0
Cutting ring connection (brass) for 6mm tube ......................................... > 2 8
Cutting ring connection (brass) for 8mm tube ......................................... > 2 9

Electrical Connection
Numbered cable, 1m, prewired ................................................................................ > 1
Numbered cable, 2.5m, prewired ............................................................................. > 2
Numbered cable, 5m, prewired ................................................................................ > 5

Output Signal
0 - 20 mA linear, 3-wire connection.................................................................................. > A
4 - 20 mA linear, 3-wire connection.................................................................................. > P
0 - 10 V DC linear, 3-wire connection............................................................................... > C

Power supply
24 V DC / AC........................................................................................................................... > L

Technische Änderungen vorbehalten • Subject to change without notice • Changements techniques sous réserve

Fischer Mess- und Regeltechnik GmbH • Bielefelder Str. 37a • D-32107 Bad Salzuflen • Tel. +49 5222 9740 • Fax +49 5222 7170 • eMail: info@fischermesstechnik.de • www.fischermesstechnik.de