INSTRUCTIONS
The steps for using the ML3 USB adapter are
summarized below. It is important to read the steps
prior to performing them.
Step 1 - Download Software to a PC
Step 2 - Prepare the USB Sticks
Step 3 - Load Software to the USB Sticks
Step 4 - Initialize the USB Card Adapter
Step 5 - Upload Operational Software or Download
Data
1 62-12042
Step 1 - Download Software to a PC
The following software needs to be downloaded to a PC
from the Carrier Container TransCentral Information
Center:
• scrl53XX.ml3 (software to upload)
• recp51XX.ml3 (software to upload)
• co2_57XX.ml3 (software to upload)
• cfXXXXXX.CF3 (latest model Configuration
required)
• menuXXXX.ml3 (latest Menu required)
• read05XX.ml3 (latest Databank required)
Procedure:
1. Navigate to TransCentral at
http://www.container.carrier.com.
2. Log into TransCentral with appropriate ID and
password.
3. Access the latest version of software by clicking
on Service > View Container Info.
4. Click on Contents View.
5. Click on Software. (Refer to Figure 1)
6. Find the appropriate software files for download.
62-12042 2
Figure 1 Software on TransCentral
3 62-12042
Step 2 - Prepare the USB Sticks
Two USB sticks are required for this procedure: one for
software upload and the other for data download. It is
recommended that the USB sticks be marked
accordingly for future use.
Software Upload Data Download
1. Plug the USB stick into the computer’s USB
port.
2. Open Windows Explorer.
3. Right-click on Removable Disk for the USB stick
and select Properties.
4. Verify the File system is FAT. (Refer to Figure 2)
Note: If the File system is not FAT, reformat
the USB stick to FAT.
To format a USB stick to a FAT File system:
a. Open Windows Explorer.
b. Right-click on Removable Disk for the USB stick
and select Format.
c. Verify the File system is FAT (Default). (Refer to
Figure 3)
d. Click on Start.
e. Click on OK, then OK, then Close.
62-12042 4
Figure 2 File System FAT
Figure 3 Format USB Stick to FAT
5 62-12042
Step 3 - Load Software to the USB Stick
Note: Do not put both unit operational software (for
upload) and data software (for download) on the same
USB stick.
A. Upload Operational Software to USB Stick
(Refer to Figure 4)
1. On the Upload USB stick, create a main folder
named “CARRIER”.
2. Create a subfolder named “MLx” under
“CARRIER”.
3. Load the following files from the PC to the USB
drive folder “MLx” for software upload:
Required Files
• cfXXXXXX.CF3 (latest Configuration
required)
• menuXXXX.ml3 (latest Menu required)
Selectable Files
• scrl53XX.ml3 (Software to upload)
• recp51XX.ml3 (Software to upload)
• co2_5703.ml3 (Software to upload)
Note: Combined file size cannot exceed 2 MB.
B. Download Data Software to USB Stick
(Refer to Figure 5)
1. On the Download USB stick, create a main
folder named “CARRIER”.
2. Create a subfolder named “MLx” under
“CARRIER”.
3. Load the file ‘read05XX.ml3’ to the USB drive
folder “MLx” for software Databank feature.
4. Create a subfolder named “DOWNLOAD” under
“CARRIER” for storing downloaded dcx files.
62-12042 6
Figure 4 Operational Software Upload
Figure 5 Data Software Download
7 62-12042
Step 4 - Initialize the USB Card Adapter
When the adapter is first used or when changing
operation from uploading software to downloading data,
or vice versa, the adapter needs to be re-initialized.
To Initialize the Adapter:
1. Power the unit ON (controller energized) without
the USB adapter installed.
2. Insert the appropriate USB stick into the adapter
(Upload or Download).
3. Insert the adapter, with correct USB stick, into
the programming slot of the controller. The
adapter is installed with the arrow pointing up /
selector switch up.
4. The green LED flashes as the adapter is
initialized. Once the initialization is complete,
the LED is solid green.
5. Once the LED is solid green, power off the unit
and remove the adapter.
Note: The adapter is now setup to either download or
upload with the software that resides on the adapter. To
determine the last state of the adapter, install the
adapter into controller, and then power the unit up. The
last menu will be displayed: "XXX K" "free" space for
download or "set" "up" for upload. If you need to switch
from one operation (software upload) to the other
operation (data download), or vice versa - you must
follow the procedure again to Initialize the adapter.
62-12042 8
Step 5 - Upload Operational Software or Down-
load Data
With software loaded on the USB stick, and the USB
Card Adapter initialized, the standard operation is the
same as DataBANK for download and software uploads
using an SRAM Card. (Refer to Annex)
A. Uploading Operational Software
With an adapter initialized for upload, use it without the
USB stick on as many units as required.
1. Power the unit OFF.
2. Insert the adapter into the programming slot of
the controller. (Refer to Figure 6)
3. Power the unit ON using the start/stop switch. Set
up will be displayed on the keypad.
4. Load software using the same procedure as
with SRAM card using the adapter.
5. When the controller displays "Pro donE" AND the
adapter LED is solid green, power the unit OFF
and remove the adapter.
If new unit software revisions are added to the
USB stick - follow Step 4 - Initialize the USB
Card Adapter procedure.
Figure 6 Adapter without USB
USB not required
9 62-12042
B. Download with USB Stick
With the adapter initialized for download, use it on as
many units for downloading as required without
initialization but the USB stick is required as the trip
data is downloaded to the stick.
1. Power the unit OFF.
2. Insert the adapter, with USB stick, into the
programming slot of the controller. (Refer to
Figure 7)
3. Power ON the start/stop switch. “XXXk Free” will
be displayed.
4. Perform the data download, similar to the
Databank card, by pressing down the arrow and
then pressing enter to select and another enter
to start.
5. When the controller displays "donE" AND the
adapter LED is solid green, power the unit OFF
and remove the adapter.
6. The download stick can now be removed and
transferred to your PC for the evaluation of the
data using the DataLINE program.
Figure 7 Adapter with USB
62-12042 10
Annex
Software Uploading or Data Downloading
The process used for either uploading or downloading
when the adapter communicates with the controller is
the same as the process used for SRAM card. Refer to
the SRAM user guides for specific instructions
“bAd cArd” Message
The “bAd cArd” message will be displayed when the
unit is powered on in the following scenarios:
• The adapter that is inserted into the controller is
initialized for software uploading, but has a USB
data downloading stick inserted.
• The adapter is initialized for data downloading
and a software upload stick is inserted.
Best practice is to install the card with no USB prior to
starting to reconfirm the Adapter initialization mode
(software upload or data download). Then if required
perform the Step 4 - Initialize the USB Card Adapter
procedure.
11 62-12042
LED Reference Chart
LED Status What it Means
Solid Green • Adapter ready with the
data copied and written to
memory
• Ready to perform opera-
tions
• USB not connected
Solid Red • Hardware fault
Recommendation:
• Re-initialize adapter
• Replace adapter
Green flashing at • Adapter initialization in
the rate of 2 Hz or progress
10 Hz
• Controller writing to the
adapter
• Data transfer complete
Recommendation:
• Do not remove until LED is
solid green
Green flashing • Adapter preparation in
during 5 sec at the progress
rate of 2 Hz
Recommendation:
• Wait for LED to go solid
Green flashing • Finalizing adapter pro-
during 20 sec at gramming
the rate of 10 Hz
Recommendation:
• Wait for LED to go solid
62-12042 12
LED Reference Chart (Continued)
LED Status What it Means
Red flashing at the • Data backup from adapter
rate of 4 Hz to USB
Recommendation:
• Wait until data backup is
complete
Red and Green are • File not found in USB stick
flashing alternately with valid extension
at the rate of 2 Hz
• Directory not found in USB
Recommendation:
• Ensure correct software
files are on adapter
• Re-initialize adapter
13 62-12042
Adapter to Unit Procedures
A. Upload Operational Software with an Adapter
1. Turn power off.
2. Insert the adapter into the programming slot on
the controller.
3. Turn unit power on. The display will show: SEt
UP.
4. Press the UP or DOWN arrow key until the
display reads:
LOAd 53XX for Scroll
LOAd 51XX for Recip
5. Press the ENTER key to confirm the software
selection. The display will alternate between:
PrESS EntR and rEV XXXX.
6. Press the ENTER key again. The display will
show: Pro SoFt. When complete, the display will
show: Pro done.
7. Verify the adapter LED is solid green, and then
turn power off and remove the adapter.
8. Turn power on and wait 30 seconds. The status
LED will be flashing fast, and there will be no
display. The controller is loading new software
into memory. This takes about 30 seconds.
When complete the controller will reset and
power up normally.
9. Wait for the unit to startup, and confirm that the
software is correct (code select: 18).
10. Turn power off. Operational software is loaded.
62-12042 14
B. Program the Model Configuration into the Con-
troller
1. Turn power off.
2. Insert the adapter into the programming slot on
the controller.
3. Turn unit power on. The display will show: SEt
UP.
4. Press the ENTER key. The display will show:
ruN COnFG.
5. Press the ENTER key again.
6. Press the UP or DOWN arrow key until the
display reads the desired model number.
7. Press the ENTER key. The display will show:
COnFG done.
8. Verify the adapter LED is solid green, and then
turn power off and remove the adapter.
9. Turn power on and confirm the model
configuration is correct during startup (code
select: 20).
10. Turn power off. Configuration is complete.
C. Set the Time (GMT) and Date to the Controller
1. Turn power off.
2. Insert the adapter into the programming slot on
the controller.
3. Turn unit power on. The display will show: SEt
UP.
4. Press the ENTER key. The display will show:
ruN COnFG.
5. Press the UP or DOWN arrow key until the
display reads: SEt tIM.
6. Press the ENTER key. The display will show the
Date: YYYY MM-DD and the DAY will be blinking.
15 62-12042
7. Press the UP or DOWN arrow key to display the
correct DD, and then press ENTER.
8. Press the UP or DOWN arrow key to display the
correct MM, and then press ENTER.
9. Press the UP or DOWN arrow key to display the
correct YYYY, and then press ENTER.
10. When you press ENTER to confirm the YEAR,
the time will be displayed and the MINUTES will
be blinking.
11. Use the UP or DOWN arrow key to display the
correct MINUTES, and press ENTER to confirm.
12. Now the HOURS will be blinking (24h format).
13. Use the UP or DOWN arrow key to display the
correct HOUR, and press ENTER.
14. When you press ENTER to confirm HOUR,
display will show: SEt tIM.
15. Verify the adapter LED is solid green, and then
turn power off and remove the adapter.
16. The Container DATE and TIME are set.
D. Program the Container I.D. Number to the Con-
troller
1. Turn power off.
2. Insert the adapter into the programming slot on
the controller.
3. Turn unit power on. The display will show: SEt
UP.
4. Press the ENTER key. The display will show:
ruN COnFG.
5. Press the UP or DOWN arrow key until the
display reads: SEt Id.
6. Press the ENTER key. The display will show the
first letter of the Container I.D.
62-12042 16
7. Press the UP or DOWN arrow key until the
correct prefix is displayed, and then press
ENTER.
8. Repeat step 7 to scroll through and adjust all
characters of the Container I.D. number.
9. When you press ENTER to confirm the last
character of the Container I.D. number, display
will show: SEt Id.
10. Verify the adapter LED is solid green, and then
turn power off and remove the adapter.
11. Turn power on and confirm the Container I.D.
number is correct during startup.
12. Turn power off. The Container I.D. is set.
E. Download Data with the use of an Adapter
1. Turn power off.
2. Insert the adapter into the programming slot on
the controller.
3. Turn power on. Display will show available free
space remaining.
4. Press UP or Down arrow key to scroll through
menu for selection. Selections are as follows:
triP, 30dAY, 60dAY, 90dAY and ALL.
5. Press ENTER key to confirm selection.
6. Display will alternate between: PrESS EntR and
selection.
7. Press ENTER key again.
8. Display will show: dnLd.
9. When download is finished, display will show:
dnLd done.
10. When adapter LED is solid green, turn power off
and remove adapter. Data download is
complete.
17 62-12042
A part of UTC Building & Industrial Systems, a
business unit of United Technologies Corporation.
Stock symbol UTX.
Carrier Transicold
P.O. Box 4805
Syracuse, NY 13221 USA
www.carrier.transicold.com