0% found this document useful (0 votes)
53 views5 pages

Sine Sweep Frequency Guide

This document discusses sine sweep vibration testing, which involves varying the excitation frequency over time from a low frequency to a high frequency using either a linear or logarithmic sweep rate. It provides examples of how to specify a sine sweep test that satisfies both the acceleration amplitude requirement and the physical displacement limits of the shaker table. In particular, it describes using a two-segment specification with an initial displacement ramp followed by a constant acceleration plateau, and calculates the crossover frequency where the displacement and acceleration requirements intersect. Finally, it discusses measuring frequency domains in units of octaves and calculating the sweep rate in octaves per minute.

Uploaded by

tamil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
53 views5 pages

Sine Sweep Frequency Guide

This document discusses sine sweep vibration testing, which involves varying the excitation frequency over time from a low frequency to a high frequency using either a linear or logarithmic sweep rate. It provides examples of how to specify a sine sweep test that satisfies both the acceleration amplitude requirement and the physical displacement limits of the shaker table. In particular, it describes using a two-segment specification with an initial displacement ramp followed by a constant acceleration plateau, and calculates the crossover frequency where the displacement and acceleration requirements intersect. Finally, it discusses measuring frequency domains in units of octaves and calculating the sweep rate in octaves per minute.

Uploaded by

tamil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

SHOCK AND VIBRATION RESPONSE SPECTRA COURSE

Unit 3. Sine Sweep Frequency and Octave Calculations

By Tom Irvine

Introduction
A common specification for a base excitation test is a sine sweep test. An example is
shown in Figure 1.

SINE SWEEP EXAMPLE


ACCEL (G)

TIME (SEC)

Figure 1.

The purpose of a sine sweep test might be to identify natural frequencies of the test item.
Another purpose might be to verify the design or workmanship of the item with respect to
vibration.1 For example, consider an avionics component subjected to a sine sweep test.
The test is considered successful if the avionics component operates properly before,

1
An argument can be made that random vibration is more effective for uncovering design or
workmanship flaws. Nevertheless, some specifications require sine sweep vibration.

1
during, and after the vibration test. Note that the component is electrically powered and
monitored during the vibration test.
The essence of a sine sweep test is that the base excitation input consists of a single
frequency at any given time. The frequency itself, however, is varied with time.
The sine sweep test may begin at a low frequency and then sweep to a high frequency, or
vice-versa. Some specifications require several cycles, where one cycle is defined as
from low to high frequency and then from high back to low frequency.
The specification might require either a linear or a logarithmic sweep rate. The sweep
will spend greater time at the lower frequency end if the sweep is logarithmic. The
example in Figure 1 has a logarithmic sweep rate.
The amplitude in Figure 1 is constant. Nevertheless, the specification might require that
the amplitude vary with frequency.

Specification Example
A vendor has a product that must withstand sinusoidal vibration with an amplitude of 12
G. The desired frequency domain is 10 Hz to 500 Hz. The shaker table has a
displacement limit of 1.0 inch peak-to-peak, or 0.5 inch zero-to-peak.
Recall from Unit 2B that the displacement limit is a constraint at low frequencies. How
should the test be specified?
The answer is to use a specification with two amplitude segments. The first segment is a
ramp. The second segment is a plateau.
Furthermore, the first segment will be given in terms of displacement. The second
segment will be given in terms of acceleration. The result is shown in Figure 2.
In this case, the ramp is 1 inch peak-to-peak. The plateau is 12 G. Note that the G value
is understood by convention to be in terms of zero-to-peak. The compromise is that the
acceleration amplitude at 10 Hz is 5 G. The compromise is needed for the sake of
"testability."

2
SINE SWEEP SPECIFICATION EXAMPLE

100
Ramp is 1.0 inch peak-peak. Plateau is 12 G.
ACCEL (G)

10

1
10 15.3 20 50 100 200 500

FREQUENCY (Hz)

Figure 2.

The "crossover" frequency is 15.3 Hz. This is the frequency at which a 12 G acceleration
has a corresponding displacement of 1.0 inch peak-to-peak.
The crossover frequency f cross is calculated via equation (1).

1 &x&peak
f cross = (1)
2π x peak

where
&x&peak is the peak acceleration (zero-to-peak)
x peak is the peak displacement (zero-to-peak)

2 2
Furthermore, the acceleration should be converted from G to in/sec or G to m/sec , as
appropriate.

3
Octaves
One octave is defined as a frequency band where the upper frequency limit is equal to
twice the lower frequency limit. Thus a band from 10 Hz to 20 Hz is one octave.
Likewise, the band from 20 Hz to 40 Hz is an octave.

The band center frequency fc is taken as

fc = fl fu (2)

where
f l is the lower frequency

f u is the upper frequency

The band center frequency calculation is not particularly important for sine sweep
calculations. It will be important in later Units, however.
A greater concern to sine sweep testing is the total number of octaves. As an example
consider the following frequency sequence in Hertz.

10 - 20 - 40 - 80 -160 - 320 - 640 - 1280 - 2560

The sequence has a total of eight octaves.


Now consider a sine sweep test from 10 Hz to 2000 Hz. How many octaves are in this
example? A rough estimate is 7.5. Nevertheless, the exact number is needed.
The number of octaves n can be calculated in terms of natural logarithms as

f 
ln  2 
 f1 
n= (3)
ln []
2

where

f l is the lower frequency of the specification

f 2 is the upper frequency of the specification

Thus, the frequency domain from 10 Hz to 2000 Hz has 7.64 octaves, per equation (3).

4
The number of octaves is then used to set the sweep rate, assuming a logarithmic rate.
For example, the rate might be specified as 1 octave/minute. The excitation frequency at
any time can then be calculated from this rate.
Or perhaps the total sweep time from 10 Hz to 2000 Hz is specified as 8 minutes. Thus,
the sweep rate is 0.955 octaves/min.

Homework
1. A shaker table has a displacement limit of 1.5 inch peak-to-peak, or 0.75 inch zero-to-
peak. An amplitude of 28 G is desired from 10 Hz to 2000 Hz. The specification will
consist of a displacement ramp and an acceleration plateau. What should the
crossover frequency be? What is the maximum acceleration at 10 Hz?

2. How many octaves are in the frequency domain from 10 Hz to 500 Hz?

3. Use program sine.exe to check your work in problems 1 and 2.

4. Program generate.exe can be used to synthesize a variety of signals. Generate and


plot a few sample signals. Note: the sample rate should be at least ten times higher
than the maximum frequency.

5. Optional. Read tutorial sweep.pdf.