Accelerating Patient Care Decision-Making:
The i-STAT System: ®
Comprehensive
Point-of-Care Testing
The i-STAT System is an advanced handheld diagnostic tool
that provides real-time, lab-quality results within minutes.
The i-STAT System:
A Wide Range of Cartridges
for Diagnostic Testing*
Chemistry Blood Gas
Results in 2 minutes Results in 2 minutes
CHEM8+ Crea G G3+ CG4+
03P91-25 03P84-25 03P83-25 03P78-25 03P85-25
Sodium (Na) Creatinine (Crea) Glucose (Glu) pH pH
Potassium (K) PCO2 PCO2
Chloride (Cl) PO2 PO2
Ionized Calcium (iCa) TCO2† TCO2†
TCO2 HCO3† HCO3†
Glucose (Glu) BEecf† BEecf†
Urea Nitrogen (BUN)/Urea sO2† sO2†
Creatinine (Crea) Lactate
Anion Gap† (Agap)
Hematocrit (Hct)
Hemoglobin† (Hgb)
Electrolytes and Hematology Blood Gas, Electrolytes and Hematology
Results in 2 minutes Results in 2 minutes
E3+ EC4+ 6+ CG8+ EG7+ EC8+ EG6+
03P82-25 03P81-25 03P80-25 03P88-25 03P76-25 03P79-25 03P77-25
Sodium (Na) Sodium (Na) Sodium (Na) Sodium (Na) Sodium (Na) Sodium (Na) Sodium (Na)
Potassium (K) Potassium (K) Potassium (K) Potassium (K) Potassium (K) Potassium (K) Potassium (K)
Hematocrit (Hct) Glucose (Glu) Chloride (Cl) Ionized Calcium (iCa) Ionized Calcium (iCa) Chloride (Cl) pH
Hemoglobin† (Hgb) Hematocrit (Hct) Urea Nitrogen Glucose (Glu) pH pH PCO2
Hemoglobin† (Hgb) (BUN)/Urea pH PCO2 PCO2 PO2
Glucose (Glu) PCO2 PO2 Urea Nitrogen TCO2†
Hematocrit (Hct) PO2 TCO2† (BUN)/Urea HCO3†
Hemoglobin† (Hgb) TCO2† HCO3† Glucose (Glu) BEecf†
HCO3† BEecf† TCO2† sO2†
BEecf† sO2† HCO3† Hematocrit (Hct)
sO2† Hematocrit (Hct) BEecf† Hemoglobin† (Hgb)
Hematocrit (Hct) Hemoglobin† (Hgb) Anion Gap† (Agap)
Hemoglobin† (Hgb) Hematocrit (Hct)
Hemoglobin† (Hgb)
Granted Waived Status for the i-STAT 1 System with lithium
and sodium heparin whole blood venous samples collected in
evacuated (green-top) tubes. *For in vitro diagnostic use only. †
Calculated
Providing Lab-Quality Results
in Minutes
Cardiac Markers Coagulation
Results in 10 minutes Results in 5 minutes Results in ≤ 5 minutes Results in <17 minutes
cTnl BNP CK-MB PT/INR Celite
ACT Kaolin
ACT
03P90-25 03P93-25 03P92-25 03P89-24 03P86-25 3P87-25
Troponin I BNP CK-MB Prothrombin Time Celite ACT Kaolin ACT
Intended Use BNP
Lactate The i-STAT BNP test is an in vitro diagnostic test for the quantitative
The test for lactate, as part of the i-STAT System, is intended for use measurement of B-type natriuretic peptide (BNP) in whole blood or
in the in vitro quantification of lactate in arterial, venous, or capillary plasma samples using EDTA as the anticoagulant. BNP measurements
whole blood. The i-STAT lactate test is useful for (1) the diagnosis and can be used as an aid in the diagnosis and assessment of the severity
treatment of lactic acidosis in conjunction with measurements of blood of congestive heart failure.
acid/base status, (2) monitoring tissue hypoxia and strenuous physical ACT Kaolin
exertion, and (3) diagnosis of hyperlactatemia. The i-STAT Kaolin Activated Clotting Time (KaolinACT) test is an in vitro
cTnI diagnostic test that uses fresh, whole blood, and is used to monitor
The i-STAT cardiac troponin I (cTnI) test is an in vitro diagnostic test high-dose heparin anticoagulation frequently associated with
for the quantitative measurement of cardiac troponin I (cTnI) in whole cardiovascular surgery.
blood or plasma. Measurements of cardiac troponin I are used in the ACT Celite®
diagnosis and treatment of myocardial infarction and as an aid in The i-STAT Celite Activated Clotting Time (CeliteACT) test is an
the risk stratification of patients with acute coronary syndromes with in vitro diagnostic test that uses fresh, whole blood, and is useful
respect to their relative risk of mortality. for monitoring patients receiving heparin for treatment of pulmonary
CK-MB embolism or venous thrombosis, and for monitoring anticoagulation
The i-STAT CK-MB test is an in vitro diagnostic test for the quantitative therapy in patients undergoing medical procedures such as
measurement of creatine kinase MB mass in whole blood or plasma catheterization, cardiac surgery, surgery, organ transplant, and dialysis.
samples. CK-MB measurements can be used as an aid in the diagnosis PT/INR
and treatment of myocardial infarction (MI). The i-STAT PT, a prothrombin time test, is useful for monitoring
patients receiving oral anticoagulation therapy such as Coumadin®
See CTI sheets for full details at abbottpointofcare.com or warfarin.
The i-STAT System provides diagnostic testing in four easy steps
Step 1: Insert two or three drops Step 2: Insert the cartridge into Step 3: View the results on the Step 4: Upload information
of blood into the cartridge the handheld handheld screen within minutes automatically into the LIS/HIS
The i-STAT System:
®
Leverage the power of a single, integrated
point-of-care testing solution
Urgent Care Surgery Centers Radiology/Imaging Centers
The fully automated i-STAT System offers a broad menu of tests
for diagnostic and treatment indicators related to disease state
management and clinical practice guidelines. Using just 2 or 3
drops of blood, the system provides time-sensitive tests at the
patient’s side in just minutes.
Family Practice/Int. Medicine Urology Oncology
Benefits of the i-STAT System
s Real-time, lab-quality results within minutes
provide accurate results for a wide range of tests right
in patient care settings
s Supports a patient-centric approach to health care i-STAT System Waived Kit (04J60-20) and
that accelerates patient care decision-making by reducing Non-waived Kit (04J48-50) include:
the time needed to get vital information to clinicians s i-STAT handheld
s Printer
s Broad and expanding range of tests with one platform s Simulator
is ideal for meeting various medical practice needs s Downloader
s Optimizes system efficiency by eliminating process s Manual
steps and handoffs to help reduce the incidence of
errors and promote patient safety
If your smart phone
is equipped with a
QR application, scan
the code to visit the
Abbott Point of Care
website.
For in vitro diagnostic use only. For CPT codes, please visit www.codemap.com/abbott.
Coumadin is a registered trademark of Bristol-Myers Squibb. To learn more about how our technology, process, and service innovations
can help your facility meet its goals, contact your i-STAT or Distribution
© Abbott Point of Care Inc.
400 College Road East, Princeton, NJ 08540
Representative, or visit www.abbottpointofcare.com.
(609) 454-9000 (609) 419-9370 (fax)
www.abbottpointofcare.com
i-STAT is a registered trademark of the Abbott
group of companies in various jurisdictions.
Ambulatory Care Core Visual Aid 026257 Rev B 05/12 Technology I Process I Services