0% found this document useful (0 votes)
93 views2 pages

Manual Book

1) The document is an instruction manual for a thyristor power regulator made by HANYOUNGNUX CO.,LTD. 2) It provides safety information and warns of dangers such as electric shock when touching live parts of the device. 3) The manual lists key specifications of the regulator including its operating voltage and frequency, rated current, control input options, and output adjusting range.

Uploaded by

Kupret Kampret
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views2 pages

Manual Book

1) The document is an instruction manual for a thyristor power regulator made by HANYOUNGNUX CO.,LTD. 2) It provides safety information and warns of dangers such as electric shock when touching live parts of the device. 3) The manual lists key specifications of the regulator including its operating voltage and frequency, rated current, control input options, and output adjusting range.

Uploaded by

Kupret Kampret
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MB0102KE121213

Thyristor Power Regulator

TPR-2N (25 A/35 A) HANYOUNGNUX CO.,LTD


1381-3, Juan-Dong, Nam-Gu Incheon, Korea.
HEAD OFFICE TEL:(82-32)876-4697 FAX:(82-32)876-4696
INSTRUCTION MANUAL http://www.hynux.net
Thank you for purchasing HANYOUNG product. PT. HANYOUNG ELECTRONIC INDONESIA
Please check whether the product is the exactly same as you ordered. INDONESIA JL.CEMPAKA BLOK F 16 NO.02 DELTA SILICON II
Before using the product, please read this instruction manual carefully. FACTORY INDUSTRIAL PARK
LIPPO CIKARANG CICAU, CIKARANG PUSAT BEKASI
Please keep this manual where you can view at any time 17550 INDONESIA
TEL : 62-21-8911-8120~4 FAX : 62-21-8911-8126

Safety information Feature


Before using the product, please read the safety information thoroughly and use it properly.Alerts •set the max output voltage by setting the slope
declared in the manual are classified to Danger, Warning and Caution by their criticality •various input signals
•Phase control and cycle control are internally selectable
DANGER DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury

WARNING WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury
Specification
Power supply voltage 110 V a.c, 220 V a.c
DANGER Operating Frequency 50/60 Hz (Dual usage)
To prevent electric shock while it is running, put to earth with the fixed screw of the unit and Rated Current 25 A, 35 A
do not touch the radiator panel since it is very hot. Do not touch or contact the input/output
terminals because they cause electric shock. Protection Circuit Protected by high-speed breaking fuse (external attachment)
Applied Load Resistive Load/ Inductive Load (use as a switch conversion)
WARNING Control Input
Input Current : 4 - 20 mA d.c, Input Voltage : 1 - 5 V d.c
• If this product is used with the machinery which may be caused human injury or serious property Input Contact Point : ON - OFF, External V. R (10 ㏀)
damage then use it after surely installing the protection equipment for two or three times. Control Method
• To prevent defection or malfunction of this product, supply proper power voltage in accordance Phase control, Cycle control, ON/OFF control
(By switch Conversion)
with the rating.
• To prevent electric shock or malfunction of product, do not supply the power until the wiring is completed. Movement type Soft start / Soft down. (Time : 0 ~ 50 sec)
• Do not decompose, modify, revise or repair this product. This may be a cause of malfunction, Output Adjusting Range Above 95 % input voltage (when putting maximum of input voltage)
electric shock or fire.
• Reassemble this product while the power is OFF. Otherwise, it may be a cause of malfunction Cooling Method Natural Cooling
or electric shock Indicator Function Output display LED lighting
Insulation Resistance 100 ㏁ min (500 V d.c mega standard)
CAUTION Output Range 0 ~ 100 %
• The place of operating this product affect to the its functions and life cycle so that avoid to
Dielectric Strength 2000 V a.c at 50/60 Hz for 1 minute
use it in the following circumstance.
- A place of having high humidity and not circulating air Line Noise Noise by noise simulator (pulse width 1 ㎲ : ±2 KV)
- A place of piling dust or impurity or having high ambient temperature or high vibration Ambient temperature 0 ~ 50 ℃ (But, Without condensation)
• The contents of this manual may be changed without prior notification.
Ambient Humidity 30 ~ 85 % R.H.
• Make sure that there is no damage or abnormality of the product during delivery.
• After turning OFF power sources of all instruments, please wire them. Storage Temperature -25 ~ 70 ℃
• The Thyristor Power Regulator shall be installed perpendicularly. Weight Approx. 960 g
• Install exhausting fan in internal and upside of the panel.
• Tighten BOLT of the input and output wire enough.
• Do not use this product at any place with corrosive (especially noxious gas or ammonia) or flammable gas.
• Do not use this product at any place with direct vibration or impact.
Dimension and panel cutout
• Do not use this product at any place with liquid, oil, medical substances, dust, salt or iron Size
W H D
contents. (Use at Pollution level 1 or 2) Capacity
• Do not polish this product with substances such as alcohol or benzene. 25 A, 35 A 92 100 131
• Do not use this product at any place with a large inductive difficulty or occurring static
electricity or magnetic noise.
• Do not use this product at any place with possible thermal accumulation due to direct
sunlight or heat radiation.
• Install this product at place under 2,000 m in altitude.
• When the product gets wet, the inspection is essential because there is danger of an
▒ Set-up Method
electric leakage or fire. Direct set-up the panel
• Do not connect anything to the unused terminals.
• After checking the polarity of terminal, connect wires at the correct position. Set-up to the mounting track
• The warranty period for this product including parts is one year if this product is properly used

※ This Product satisfies CE safety standard (EMC Directive) when using with a
Noise Filter which is specified by Hanyoung Nux co.,Ltd.
A few megahertz or low area noise are distributed inside of noise frequency
components which are available on the market canot reduce Noise sufficiently.
Please refer to manual for the further infomation.

※ How to Operate
• When installing the unit, the input and output terminals shall be attached in the direction of
facing downward perpendicularly for the natural cooling.
• Certainly, install high-speed breaking fuse between terminal R and power source

Suffix code
Model Code Description
TPR    Thyristor Power Regulator
Phase 2N Single Phase
110 110 V a.c 50/60 Hz
Power supply voltage
220 220 V a.c 50/60 Hz
25 25 A
Rated current
35 35 A
※ Control Method : Phase control (factory default)

3
Connection Diagram Function Description
▒ Terminal Arrangement ▒ Control Method Selection
Control Method

 CYCLE (Cycle Control)


Switch   PHASE
Position  (PHASE CONTROL: Factory Default)
 INDUCTOR (L Load)

(Since the switch method can not be changed during the operation, it is important to check the
position of the switch before inserting the power. Please, insert the power after checking the
position of the switch.)
▒ Noise Filter (Option) ▒ Noise Filter Connection Digram
▒ Cycle Control (Zero Crossing Control)
Type Current capacity TPR-2N Cycle Control method is a method of making a loaded
power as proportionally repeated ON/OFF cycle by a
HHD-2025B 25 A
signal of input control in a fixed cycle. The proportionally
R T W U
HHD-2035B 35 A repeated ON/OFF cycle makes the power applied to the
Circuit breaker load be regularly. This method is better than Phase
Control since this control method makes the loaded
Power Noise power be ON/OFF at the zero point of AC when it is
Supply IN Filter
OUT Load (Heater)
ON/OFF so that there is almost no noise occurrence and
it is better for the linearity compared to the Phase Control.
•In Cycle Control, SOFT START function is not operating.

▒ Phase Control
▒ How to wire the input signal terminal AC power source has 50/60 Hz frequency and 1/2 cycle of 60 Hz frequency appears a value of
•Using 4 - 20 mA d.c, OUT ADJ (internal volume) • Using 4 - 20 mA d.c, External V.R (10 ㏀) 0 ~ 180 degree in about 8.33 ms. Phase Control is a method that after inputting 1/2 cycle into AC
power source, it proportionally generates power between 0 ~ 180 degree in 8.33 ms according to
the control signal. Also, this method can be fully adjusted according to the wave form of AC so that
AC motors and other variety of electronic devices are controlled easily.

According to the input 4 - 20 mA d.c, the According to the input 4 - 20 mA d.c, the
output is limited by OUT ADJ. output is limited by external V.R.

•Using External V.R(10㏀), OUT •Using only OUT ADJ(internal volume)


▒ ON/OFF Control (Contact Control)
ADJ(internal volume) [Manual Control] [Manual Operation Control] ON/OFF Control is automatically set by the wiring terminal. (Refer to the wiring diagram of the input
signal terminal.) Not by receiving the input voltage and input current, this method controls the
output voltage by receiving contact point signal of relay and others.

•Using ON/OFF, External V.R(10㏀) •Using ON/OFF, OUT ADJ(internal volume)

▒ Output Voltage Limitation (OUT ADJ)


When selecting the external V.R(10㏀), the output voltage limitation (OUT ADJ) is also operating.(Factory
default Setting= Maximum) If you do not want to use the factory default then turn to the maximum.
By external V.R, the output voltage is limited. By external V.R, the output voltage is limited. •This can not be used in ON/OFF Control.

▒ SOFT START (DOWN)
Parts Name If turn ON the power switch for the first time then there may be damaged to the load or electric power
element or others since the maximum power delivers to the loads when using inductive load or etc. to
Panel hook capacitive load. Therefore, SOFT START function
(M4×5) for helps to increase gradually the loaded voltage.
Setting Up •Setting Time: 0 ~ 50 seconds
(Factory default setting = 0 second)
•If SOFT START VOLUME is turned to the minimum
Case then SOFT will not be operated.
•In the Cycle Control, SOFT will not be operated.
•All the operation, other than those, can be used
by the selection.
LED for Output •There is no meaning in the ON/OFF Control.
Display
Terminal Cover ▒ Output Display LED
If the control operation is normally operated after inserting the power supply then the LED will do
Control Method the lighting operation.
Selection Switch
How to detach the terminal cover
Soft Start ▒ Detachment
Input Signal
Volume Setting
Terminal Block When looking at the front of the terminal cover,
Volume for certainly give the force in the direct of the number 1
Limiting Output Load Connection in the right side and lift in the direction of the
(OUT ADJ) Terminal Block number 2 then detach it.
Panel hook
(M4×5) for ▒ Attachment
Setting Up When looking at the front of the terminal cover,
surely after inserting the left hole to the case body
first, give the force in the direction of the direction of
the number2 then attach to the body hole.