GAB 2/2-way solenoid valve of forged brass body
/sub-base mounting for general application
Normally closed
Direct-operated sub-base mounting Type
Orifice CV Fluid Seat Differential pressure kg/cm 2 (bar) Wt.
Model (mm) value temp. disc Liquid Air Gas Naphtha
(kg)
(˚C ) (120˚C)
GAB-312-A 1.2 0.06 -10 NBR 0-50 0-50 0-50 0-50 0.43
GAB-312-B 1.6 0.09 0-30 0-30 0-30 0-30 0.43
Viton ®
GAB-312-2 2.0 0.11 0-15 0-15 0-15 0-15 0.43
∫ Silicone
GAB-312-3 3.0 0.26 0-10 0-10 0-10 0-10 0.43
80 PTFE 0-6 0-6 0-6 0.43
GAB-312-4 4.0 0.58 0-6
(120) EPDM
GAB-312-5 5.0 0.64 0-3 0-3 0-3 0-3 0.43
How to order
GAB - 312 - A - N - E1 - A - 220VAC
Voltage
Application : None-Liquid (water,hot water)
A-Air
G-Gas
N-Naphtha
Coil: E1-Square cable wire (WP-Al-E)
C1-Round cable wire (WP-A1-C)
D1-Square DIN for AC (WP-A1-D)
F1-Round DIN for DC (WP-C1-D)
EX-Explosion proof (EX-B2)
Seat : N-NBR (BUNA N)
S-Silicone
E-EPDM
V-Viton® (FKM)
T-PTFE
Orifice : A-1.2mm
B-1.6mm
2-2mm
3-3mm
4-4mm
5-5mm
Code
Model
Notes: Inapplicable Fluids:
1. Voltage drop range is within ±10%. 1. Fluids that have kinematic viscosity over 50 CST.
2. Pressure of voltage DC is 70% of voltage AC only. 2. Fluids that will turn to liquid after being heated
3. Selection of coil refer to page 136~139. and become solid after being cooled.
3. Corrosive fluids.
GAB 2/2-way solenoid valve of forged brass body
/sub-base mounting for general application
GAB-312-A~5 Contour Specification Chart Unit:mm
GAB 2/2-way solenoid valve of forged brass body
/sub-base mounting for general application
Normally closed
Direct-operated sub-base mounting Type
Orifice CV Fluid Seat Differential pressure kg/cm 2 (bar) Wt.
Model (mm) value temp. disc Liquid Air Gas Naphtha
(kg)
(˚C ) (120˚C)
GAB-412-2 2.0 0.11 -10 NBR 0-25 0-25 0-25 0-25 0.64
Viton ®
GAB-412-3 3.0 0.26 0-15 0-15 0-15 0-15 0.64
∫ Silicone
GAB-412-4 4.0 0.58 80 PTFE
0-10 0-10 0-10 0-10 0.64
GAB-412-5 5.0 0.64 (120) EPDM 0-6 0-6 0-6 0-6 0.64
How to order
GAB - 412 - 2 - N - E2 - G - 220VAC
Voltage
Application : None-Liquid (water,hot water)
A-Air
O-Oil
G-Gas
N-Naphtha
Coil : E2-Square cable wire (WP-A2-E)
C2-Round cable wire (WP-A2-C)
D2-Square DIN for AC (WP-A2-D)
F2-Round DIN for DC (WP-C2-D)
EX-Explosion proof (EX-B2)
Seat : N-NBR (BUNA N)
S-Silicone
E-EPDM
V-Viton®(FKM)
T-PTFE
Orifice : 2-2mm
3-3mm
4-4mm
5-5mm
Code
Model
Notes: Inapplicable Fluids:
1. Voltage drop range is within ±10%. 1. Fluids that have kinematic viscosity over 50 CST.
2. Pressure of voltage DC is 70% of voltage AC only. 2. Fluids that will turn to liquid after being heated
3. Max. temperature is up to 120˚C. and become solid after being cooled.
4. Selection of coil refer to page 136~139. 3. Corrosive fluids.
GAB 2/2-way solenoid valve of forged brass body
/sub-base mounting for general application
GAB-412-2~5 Contour Specification Chart Unit:mm
HAB 2/2-way solenoid valve of forged brass body
/sub-base mounting for general application
Normally closed
Direct-operated sub-base mounting Type
Orifice CV Fluid Seat Differential pressure kg/cm 2 (bar) Wt.
Model (mm) value temp. disc Liquid Air Gas Naphtha
(kg)
(˚C ) (120˚C)
HAB-412-3 3.0 0.26 -10 NBR 0-30 0-30 0-30 0-30 0.64
Viton ®
HAB-412-4 4.0 0.58 ∫ Silicone 0-20 0-20 0-20 0-20 0.64
80 PTFE
HAB-412-5 5.0 0.64 (120) EPDM 0-15 0-15 0-15 0-15 0.64
How to order
HAB - 412 - 2 - N - C3 - G - 220VAC
Voltage
Application : None-Liquid (water.hot water)
A-Air
O-Oil
G-Gas
N-Naphtha
Coil : C3-Round cable wire (WP-A3-C)
EX-Explosion proof (EX-B2)
Seat : N-NBR (BUNA N)
S-Silicone
E-EPDM
V-Viton® (FKM)
T-PTFE
Orifice : 3-3mm
4-4mm
5-5mm
Code
Model
Notes: Inapplicable Fluids:
1. Voltage drop range is within ±10%. 1. Fluids that have kinematic viscosity over 50 CST.
2. Pressure of voltage DC is 70% of voltage AC only. 2. Fluids that will turn to liquid after being heated
3. Selection of coil refer to page 136~139. and become solid after being cooled.
3. Corrosive fluids.
HAB 2/2-way solenoid valve of forged brass body
/sub-base mounting for general application
Unit:mm
HAB-412-3~5 Contour Specification Chart
Bottom Fixing Specification Chart Unit:mm