0% found this document useful (0 votes)
96 views23 pages

Infiniivision 1000 X-Series Oscilloscopes: 2 Channel: Edux1002A Edux1002G Dsox1102A Dsox1102A

manual

Uploaded by

VeGi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
96 views23 pages

Infiniivision 1000 X-Series Oscilloscopes: 2 Channel: Edux1002A Edux1002G Dsox1102A Dsox1102A

manual

Uploaded by

VeGi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 23

InfiniiVision 1000 X-Series Oscilloscopes

2 Channel: EDUX1002A; EDUX1002G; DSOX1102A; DSOX1102A

4 Channel: DSOX1204A; DSOX1204G


Find us at www.keysight.com Page 1
Table of Contents

Leading technology in a value priced oscilloscope .......................................................... 3


Leading technology in a value priced oscilloscope (education model).............................. 4
Leading Technologies..................................................................................................... 5
6-in-1 instrument integration ........................................................................................... 6
More productivity tools .................................................................................................... 8
A real oscilloscope........................................................................................................ 10
Configuring Your InfiniiVision 1000X-Series Oscilloscope ............................................. 12
Performance Characteristics......................................................................................... 15
Environmental .............................................................................................................. 22

Need more bandwidth, sampling rate, and analysis?


Consider the InfiniiVision 3000T X-Series

– 350 MHz, 500 MHz and 1 GHz


– 5 GSa/s
– Uncompromised 1,000,000 waveform update rate
– Capacitive touch screen
– Industry exclusive zone touch trigger
– Plenty decode/trigger and gated FFT

Find us at www.keysight.com Page 2


Leading technology in a value-priced oscilloscope
Keysight’s InfiniiVision 1000 X-Series oscilloscopes are engineered to give you quality, industry-proven
technology at unbelievably low prices. Now it’s easy to get professional measurements and accessible expertise
at your fingertips. Don’t settle for less – and test to impress.

– 70 to 200 MHz
– Frequency Response Analysis (Bode gain & phase plots), included in models with WaveGen
– See more signal detail with 50,000 wfms/sec update rate
– Have confidence in your measurements with Keysight-custom technology that leverages more than
60 years of oscilloscope expertise
– Test quickly and easily with a simple, intuitive user interface and built-in help and training signals
– Get professional-level functionality with industry-leading software analysis and 6-in-1 instrument
integration

DSOX1102A DSOX1102G DSOX1204A DSOX1204G


70/100 MHz, 2 channel 70/100 MHz, 2 channel 70/100/200 MHz, 4 channel 70/100/200 MHz, 4 channel
with function generator with function generator
Analog channels 2 2 4 4
External trigger 1(can be used as a 3rd digital 1 (can be used as a 3rd digital 1 (back) 1 (back)
channel at the front) channel at the front)
Bandwidth 70 MHz (base) 70 MHz (base) 70 MHz (base) 70 MHz (base)
100 MHz (DSOX1B7T102) 100 MHz (DSOX1B7T102) 100 MHz (D1200BW1A) 100 MHz (D1200BW1A)
200 MHz (D1200BW2A) 200 MHz (D1200BW2A)
Maximum sample rate 2 GSa/s (all channels) 2 GSa/s (all channels) 2 GSa/s (half channels) 2 GSa/s (half channels)
1 GSa/s (all channels) 1 GSa/s (all channels)
Maximum memory depth 1 Mpts 1 Mpts 1 Mpts 1 Mpts
Segmented memory Standard Standard Standard Standard
Mask/limit testing Standard Standard Standard Standard
WaveGen Not available 20-MHz function generator Not available 20-MHz function generator
(includes Bode plot test) (includes Bode plot test)
Serial protocol analysis Option: Option:
I²C, SPI, UART/RS-232 - (DSOX1EMBD) I²C, SPI, UART/RS-232 - (D1200EMBA)
CAN, LIN - (DSOX1AUTO) CAN, LIN - (D1200AUTA)
Waveform math Add, subtract, multiply, divide, FFT (magnitude and phase), low pass filter
Integrated digital voltmeter Free with product registration
Display 7-inch TFT LCD WVGA
Waveform update rate 50,000 waveforms per second
Connectivity USB 2.0 (host and device) USB 2.0 (host and device)
LAN

Find us at www.keysight.com Page 3


Leading technology in a value-priced oscilloscope (education model)
EDUX1002A and EDU1002G

Provide a quality education for students and prepare for the industry with professional level
instruments. The 1000 X-Series leverages the same technology as our higher-end oscilloscopes, allowing students to
learn on the same hardware and software being used in leading R&D labs. Don’t settle for less – set your students up for
success

– Built-in training signals that enable students to quickly learn to capture and analyze signals.
– The educator's resource kit includes dynamic teaching labs; a comprehensive lab guide; a tutorial
written specifically for undergraduate students; and an oscilloscope fundamentals PowerPoint slide
set for professors and lab assistants.
– IoT systems design applied courseware. The 1000 X-Series oscilloscope can be used with the
U3800A Internet of Things(IoT) Systems Design Applied Courseware.
– Bode plots are fundamental concepts. The 1000 X-Series’ frequency response analyzer capability is
the perfect tool to help students understand the gain and phase performance of passive LRC
circuits or active op-amps.
– BenchVue Software with the BV0004B BenchVue Oscilloscope app lets you control and visualize
the 1000X-Series and multiple measurements simultaneously.

EDUX1002A EDUX1002G
50 MHz, 2 channel 50 MHz, 2 channel with function generator

Analog channels 2 2
External trigger (or 3rd digital channel) 1 1
Bandwidth 50 MHz 50 MHz
Maximum sample rate 1 GSa/s 1 GSa/s
Maximum memory depth 100 kpts 100 kpts
WaveGen Not available 20-MHz function generator (includes Bode plot test)
Serial protocol analysis Option:
I²C, UART/RS-232 - (EDUX1EMBD)
Waveform math Add, subtract, multiply, divide, FFT (magnitude and phase), low pass filter
Display 7-inch TFT LCD WVGA
Waveform update rate 50,000 waveforms per second
Connectivity USB 2.0 (host and device)

Find us at www.keysight.com Page 4


Leading Technologies
(Click on below, you will be redirected to VIDEO on Keysight Youtube channel)

Have confidence in your measurements with Keysight-custom technology that leverages more than 60
years of oscilloscope expertise.
Low-cost oscilloscopes don’t have to be low quality. Designing premier test solutions has been the goal and
passion of Keysight Technologies ever since we made our first oscillator in 1939, and now we’re bringing you a
professional-quality oscilloscope for a fraction of the price.

Up to 50,000 wafeform update rate and catch glitch easily.

Training Signals

Superior Measurements Memory Performance

FFT

MegaZoom IV
ASIC
Segment Memory.

Mask test
Intuitive Controls / Built-in Help

Find us at www.keysight.com Page 5


6-in-1 instrument integration
Get professional-level oscilloscope functionality with industry-leading software analysis and 6-in-1 instrument
integration. The 1000 X-Series gives you the following functionality, so you can save money and valuable bench
space.

OSCILLOSCOPE

The 1000 X-Series is a family of low-cost oscilloscopes that don’t


compromise on quality. Each has measurement and software analysis
capability that rivals oscilloscopes 3x the price.

WaveGen (built-in 20 MHz function generator with modulation capability)

(EDUX1002G, DSOX1102G, and DSOX1204G models only)


The 1000 X-Series offers an integrated 20 MHz function generator
with a signal modulation capability. It’s ideal for educational or design
labs where bench space and budget are at a premium. The
integrated function generator provides stimulus output of sine,
square, ramp, pulse, DC and noise waveforms to your device under
test Add modulation to the signal with customizable AM, FM and FSK
settings. No need to buy a separate function generator when you
can get one integrated into your new oscilloscope. WaveGen is
available on EDUX1002G, DSOX1102G, and DSOX1204G models
only. The WaveGen function enables the definition of multiple
waveforms including amplitude modulated signals

Hardware-based serial protocol decode and triggering

When you add optional software, the 1000 X-


Series is a powerful protocol analyzer that can do
powerful decode and hardware-based triggering
that enables specialized serial communication
analysis. Other vendors’ oscilloscopes use
software post-processing techniques that slow
down the waveform and decode update rate, but
the 1000 X-Series has faster decoding by using
hardware-based technology that enhances scope
usability and the probability of capturing
infrequent serial communication errors.

Find us at www.keysight.com Page 6


6-in-1 instrument integration (continued)
Frequency Response Analyzer (EDUX1002G, DSOX1102G, and DSOX1204G models only)

Frequency response analysis is a critical measurement to characterize the stability of feedback networks and switch-
mode power supplies. Bode plots are fundamental
concepts that every electrical engineering student
must know. The 1000 X-Series’ frequency
response analyzer capability is the perfect tool to
help students understand the gain and phase
performance of passive LRC circuits or active op-
amps. This capability is achieved with a gain and
phase measurement versus frequency (Bode plot).
Vector network analyzers (VNAs) and low-cost
frequency response analyzers are typically used for
these measurements, but now an easy-to-use gain
and phase analysis is possible by utilizing the 1000
X-Series’ built-in WaveGen. (EDUX1002G,
DSOX1102G, and DSOX1204G models only).

Digital Voltmeter

The 1000 X-Series has an integrated 3-digit voltmeter (DVM)


inside each oscilloscope. The voltmeter operates through
probes connected to the oscilloscope channels, but its
measurement is decoupled from the oscilloscope triggering
system so both the DVM and triggered oscilloscope
measurements can be made with the same connection. You
can quickly measure AC RMS, DC, and DC RMS without
configuring the oscilloscope capture. The voltmeter results
are always displayed, keeping these quick characterization
measurements at your fingertips. Turn on the DVM capability
for no additional cost by registering your oscilloscope.

Frequency Counter

An integrated 5-digit frequency counter inside each oscilloscope. It operates through


probes connected to the oscilloscope channels, but its measurement is decoupled
from the oscilloscope triggering system, so both the counter and triggered
oscilloscope measurements can be made with the same connection. You can quickly
measure frequency without configuring the oscilloscope capture. The voltmeter
results are always displayed, keeping these quick characterization measurements at
your fingertips. Turn on the counter capability for no additional cost by registering
your oscilloscope.

Find us at www.keysight.com Page 7


More productivity tools
Localized GUI and help
Operate the oscilloscope in the language most familiar to you. The graphical user
interface (GUI), built-in help system, front panel overlays, and user’s manual are
available in English, Simplified Chinese, Traditional Chinese, Japanese, Korean,
French, German, Italian, Portuguese, Russian and Spanish. The GUI and front panel
overlay are also available in Polish, Thai, and Czech, and the built-in help is also
available in Polish and Thai During operation. Access the built-in help system by
simply pressing and holding any button.

Probe solutions
Get the most out of your 1000 X-Series oscilloscope by using the right probes and
accessories for your application. Keysight offers a complete family of innovative
probes and accessories for the InfiniiVision 1000 X-Series.

Connectivity and remote control (LAN connectivity for DSOX1204A/G only)


Built-in USB host and USB device ports make PC connectivity easy. BenchVue
Software with the BV0004B BenchVue Oscilloscope app lets you control and visualize
the 1000 X-Series and multiple measurements simultaneously. Build automated test
sequences just as easy as using your front panel. Save time with the ability to export
measurement data to Excel, Word, and MATLAB in three clicks. Monitor and control
your 1000 X-Series with a mobile device from anywhere.

Standard LAN port in the 4-channel models (DOSX1204A/G series) supports remote
web-based virtual front panel to control and to save data or images.

Web-based virtual front panel. (DSOX1204A/G model only).

Find us at www.keysight.com Page 8


More productivity tools (continued)
Offline oscilloscope analysis software
Keysight’s N8900A Infiniium Offline PC-based oscilloscope analysis
software lets you do additional signal viewing, analysis, and
documentation tasks while you’re away from your oscilloscope. You
can capture waveforms on your scope, save to a file and recall the
waveforms into the Infiniium Offline software on your PC

BenchVue oscilloscope app


The Oscilloscope App within BenchVue enables control of
oscilloscopes to quickly capture and annotate screen images,
record trace data and data log measurements (included in
model BV0000A) Build automated test sequences just as easy
as using your front panel. Save time with the ability to export
measurement data to Excel, Word, and MATLAB in three clicks.
Monitor and control your 1000 X-Series with a mobile device
from anywhere.

Oscilloscope basic courseware


The Educator’s Oscilloscope Training Kit provides an array of built-in
training signals so that electrical engineering and physics students can
learn what an oscilloscope does and how they can perform basic
oscilloscope measurements. Also included in the kit is a
comprehensive oscilloscope lab guide and tutorial written specifically
for the undergraduate student. Keysight also provides a PowerPoint
slide-set that professors and lab assistants can use as a pre-lab
lecture on oscilloscope fundamentals. This lecture takes about 30
minutes and should be presented before electrical engineering and
physics students begin their first circuits lab. Note that this PowerPoint
slide-set also includes a complete set of speaker notes.

IoT systems design courseware


The 1000 X-Series oscilloscope can be used with the U3800A Internet of
Things (IoT) Systems Design Applied Courseware, which is designed to
give students the opportunity to work with industry-grade test and
measurement instruments The IoT Systems Design Applied Courseware is
a ready-to-teach package that equips students with the knowledge on how
to design and develop an embedded system with IoT capabilities.
Designed as a resource for educators, the courseware consists of teaching
slides and a training kit and integrates hands-on industry-relevant
experiences and real-world applications in IoT systems design and testing.

Find us at www.keysight.com Page 9


A real oscilloscope
Measurements

Press the measure key to access 24 built-in


automatic measurements

Built-in localized-help

All buttons provide instant access to


language-localized help by simply holding
down the button you want explained
Cursors

Custom measurements are easily accomplished by


cursors. Measure any value or the difference using four
powerful cursors

Waveform Tools
USB save
Quick access to waveform math (+ − × ÷) and
Screenshots and date can be saved easily FFT. Reference Waveforms allow quick
and fast with built-in USB port and your comparison of stored waveforms
` USB storage device.

Industry leading user Interface External Trigger

It can be used for triggering or


Fast and easy operation with the common
oscilloscope controls right at your fingertips. displayed as a 3rd channel for a
digital signal. It can also be used
to create a 3-channal bus-type
display

Find us at www.keysight.com Page 10


Fast Waveform Update Rate
Analyze Features
Fast 50,000 waveforms/sec update rate
Mask Limit Testing DVM
helps you quickly see random and infrequent
Frequency Response Analysis
signal glitches and errors
Serial Bus Decode

Compact Size with Big Screen


Remote Control
314 mm × 165 mm × 130 mm
(12.4” × 6.5” × 5.1”) 7” WVGA USB
LAN (DSOX1204 model only)

New 4 Analog channel

Includes four 1:1/10:1 switchable probes


Digital Voltmeter

Integrated 3-digit voltmeter


5-digit frequency counter Function Generator

Built-in generator enables you to


generate the signals you need to
quickly simulate your design.
Training Signals
Frequency Response Analysis
Standard in all models so you can
quickly learn how to troubleshoot many Built-in generators are easily synchronized for measuring
common signal problems stimulus/response testing including Bode Plot for Gain & Phase

Find us at www.keysight.com Page 11


Configuring Your InfiniiVision 1000X-Series Oscilloscope
Step 1 Choose your oscilloscope
EDUX1002A 50 MHz, 2 channel
EDUX1002G 50 MHz, 2 channel with function generator
DSOX1102A 70/100 MHz, 2 channel
DSOX1102G 70/100 MHz, 2 channel with function generator
DSOX1204A 70/100/200 MHz, 4 channel
DSOX1204G 70/100/200 MHz, 4 channel with function generator

Step 2 Select bandwidth upgrades


Model: DSOX1102A/G

DSOX1B7T102 Upgrade bandwidth from 70 to 100MHz Compatible with DSOX1102A or DSOX1102G

Model: DSOX1204A/G

D1200BW1A Upgrade bandwidth from 70 to 100MHz Compatible with DSOX1204A or DSOX1204G


D1200BW2A Upgrade bandwidth from 70 to 200MHz Compatible with DSOX1204A or DSOX1204G
D1200BW3A Upgrade bandwidth from 100 to 200MHz Compatible with DSOX1204A or DSOX1204G

Step 3 Add desired decodes


Model: EDUX1002A/G
2
EDUX1EMBD Decodes and analysis for I C, UART(RS-232) protocols Compatible with EDUX1002A or EDUX1002G

Model: DSOX1102A/G
2
DSOX1EMBD Decodes and analysis for I C, SPI, UART(RS-232) protocols Compatible with DSOX1102A or DSOX1102G
DSOX1AUTO Decodes and analysis for CAN, LIN protocols Compatible with DSOX1102A or DSOX1102G

Model: DSOX1204A/G
2
D1200EMBA Decodes and analysis for I C, SPI, UART(RS-232) protocols Compatible with DSOX1204A or DSOX1204G
D1200AUTA Decodes and analysis for CAN, LIN protocols Compatible with DSOX1204A or DSOX1204G

Find us at www.keysight.com Page 12


Configuring Your InfiniiVision 1000X-Series Oscilloscope (continued)
Step 4 Choose probes, accessories, and additional software options
Passive Probes
N2142A 1:1, 10:1 switchable 75 MHz passive probe 2 probes included standard with EDUX1002A/G
N2140A 1:1, 10:1 switchable 200 MHz passive probe 2 probes included standard with DSOX1102A/G
4 probes included standard with DSOX1204A/G
N2842A 10:1, 300 MHz passive probe Option
N2889A 1:1, 10:1 switchable 350 MHz passive probe Option
10070D 1:1, 20 MHz passive probe Option
N2870A 1:1, 35 MHz passive probe Option
N7007A 10:1 400 MHz extreme temperature passive probe Option
10076C 100:1 500 MHz 3.7 KV high voltage passive probe Option

Differential Probes
N2791A 25 MHz, 10:1, 100:1 switchable high voltage up to ± 700V Option
N2891A 70 MHz, 100:1, 1000:1 switchable high voltage up to ± 7000V Option

Current Probes
1146B 100 kHz, 100A, AC/DC current probe Option
N2780B 2 MHz, 500A, AC/DC current probe (with N2779A power supply) Option
N2781B 10 MHz, 150A, AC/DC current probe (with N2779A power supply) Option
N2783B 50 MHz, 30A, AC/DC current probe (with N2779A power supply) Option
N2783B 100 MHz, 30A, AC/DC current probe (with N2779A power supply) Option
N7040A 23 MHz, 3 kA, AC current probe (Rogowski coil) Option
N7041A 30 MHz, 600A, AC current probe (Rogowski coil) Option
N7042A 30 MHz, 300A, AC current probe (Rogowski coil) Option

Software Application
N5467B/C User-defined Application (UDA) software Option
BV0004B BenchVue oscilloscope application Option
N8900A Infiniium Offline Oscilloscope Analysis Software Option

Other Accessories
N2137A User's Guide for InfiniiVision DSOX1204A/G model Option, Compatible with DSOX1204A/G
N2132A User's Guide for InfiniiVision EDUX1002A/G model and DSOX1102A/G model Option, Compatible with EDUX1002A/G, DSOX1102A/G
N2738A Soft carrying case for 1000 X-Series oscilloscopes Option
N2133A Rackmount kit for 1000 X-Series oscilloscopes (white) Option
N2138A Rackmount kit for 1000 X-Series oscilloscopes (black) Option

Find us at www.keysight.com Page 13


Configuring Your InfiniiVision 1000X-Series Oscilloscope (continued)
Step 5 Select language options (hard copy of user guide is not included unless ordered)
Model: EDUX1002A/G and DSOX1102A/G
Front panel overlay User's guide
English Standard N2132A-ABA
Chinese (Simplified) DSOX1000-AB2 N2132A-AB2
Chinese (Traditional) DSOX1000-AB0 N2132A-AB0
Czech DSOX1000-AKB Not available
French DSOX1000-ABF N2132A-ABF
German DSOX1000-ABD N2132A-ABD
Italian DSOX1000-ABZ N2132A-ABZ
Japanese DSOX1000-ABJ N2132A-ABJ
Korean DSOX1000-AB1 N2132A-AB1
Polish DSOX1000-AKD Not available
Portuguese DSOX1000-AB9 N2132A-AB9
Russian DSOX1000-AKT N2132A-AKT
Spanish DSOX1000-ABE N2132A-ABE
Thai DSOX1000-AB3 Not available
Turkish DSOX1000-AB8 Not available

Model: DSOX1204A/G
Front panel overlay User's guide
English Standard N2137A-ABA
Chinese (Simplified) DSOX1200-AB2 N2137A-AB2
Chinese (Traditional) DSOX1200-AB0 N2137A-AB0
Czech DSOX1200-AKB Not available
French DSOX1200-ABF N2137A-ABF
German DSOX1200-ABD N2137A-ABD
Italian DSOX1200-ABZ N2137A-ABZ
Japanese DSOX1200-ABJ N2137A-ABJ
Korean DSOX1200-AB1 N2137A-AB1
Polish DSOX1200-AKD Not available
Portuguese DSOX1200-AB9 N2137A-AB9
Russian DSOX1200-AKT N2137A-AKT
Spanish DSOX1200-ABE N2137A-ABE
Thai DSOX1200-AB3 Not available
Turkish DSOX1200-AB8 Not available

Included standard
Standard passive probes (Two N2142A for EDUX1002A/G;
Two N2140A for DSOX1102A/G;
Four N2140A for DSOX1204A/G)
Standard secure erase
Interface language support GUI: English, Japanese, Simplified Chinese, Traditional Chinese, Korean, German, French, Spanish, Russian, Portuguese, Italian,
Polish, Czech, Thai, and Turkish
Built-in help language support for English, Japanese, Simplified Chinese, Traditional Chinese, Korean, German, French, Spanish, Russian, Portuguese, Italian,
Polish, and Thai
Localized Power cord
Certificate of calibration

Find us at www.keysight.com Page 14


Performance Characteristics
Oscilloscopes overview
EDUX1002A/EDUX1002G DSOX1102A/DSOX1102G DSOX1204A/DSOX1204G
Bandwidth (–3 dB) 1, 2 50 MHz 70 MHz 70 MHz
100 MHz (option DSOX1B7T102) 100 MHz (option D1200BW1A)
200 MHz (option D1200BW2A)
Calculated rise time (10 to 90%) ≤ 7 ns ≤ 5 ns (70 MHz model) ≤ 5 ns (70 MHz model)
≤ 3.5 ns (100 MHz model) ≤ 3.5 ns (100 MHz model)
≤ 1.7 ns (200 MHz model)
Input channels 2 2 4
Maximum sample rate 1 GSa/s 2 GSa/s 2 GSa/s half-channel interleaved
1 GSa/s per channel
Maximum memory depth 100 kpts 1 Mpts 1 Mpts
Waveform update rate ≥ 50,000 waveforms/sec ≥ 50,000 waveforms/sec ≥ 50,000 waveforms/sec

Vertical system analog channels


EDUX1002A/EDUX1002G/DSOX1102A/DSOX1102G/DSOX1204A/DSOX1204G
Input coupling DC, AC (10 Hz cutoff frequency)
Input impedance/capacitance 1 MΩ ± 2%/16 pF ±3 pF
Input sensitivity range 3 500 μV/div to 10 V/div
Standard probes N2142A 1/10 switchable 75 MHz (2 included in EDUX1002A/EDUX1002G)
N2140A 1/10 switchable 200 MHz (2 included in DSOX1002A/DSOX1002G)
N2140A 1/10 switchable 200 MHz (4 included in DSOX1204A/DSOX1204G)
Probe attenuation factor 0.1X to 1000X in 1-2-5 sequence; (–20 dB to +80 dB in 0.1 dB steps)
Hardware bandwidth limits Approximately 20 MHz (selectable)
Vertical resolution 8 bits
Invert signal Selectable
Maximum input voltage 150 Vrms, 200 Vpk
DC vertical accuracy ± [DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]
DC vertical gain accuracy 1 +3% full scale (> 10 mV/div)
+4% full scale (< 10 mV/div)
DC vertical offset accuracy ± 0.1 div ± 2 mV ± 1% of offset setting
Skew Channel to channel: 1 ns (without deskew)
Channel to external: 2 ns (without deskew)
Offset range 500 uV/div to 200 mV/div: +2 V
> 200 mV/div to 10 V/div: +100 V

1. Denotes warranted specifications; All others are typical. Specifications are valid after a 30-minute warm-up period and from ± 10 °C user calibration temperature.
2. For 1 mV/div to 10 V/div settings, bandwidth is 20 MHz at the 500 μV/div setting.
3. 500 μV/div is a magnification of 1 mV/div setting.

Find us at www.keysight.com Page 15


Performance Characteristics (continued)
Horizontal system analog channels
All Models
Time base range 5 ns/div to 50 s/div
Horizontal resolution 2.5 ps
Time base accuracy 4 50 ppm ± 5 ppm per year (aging)
Time base delay time range Pre-trigger: Greater of 1 screen width or 200 μs
Post-trigger: 1 to 500 s
Channel to channel deskew range ± 100 ns
Δ Time accuracy (using cursors) ± (time base acc. x reading) ± (0.0016 x screen width) ± 200 ps (same channel)
Modes Main, zoom, roll, XY
XY X = channel 1, Y = channel 2, Z = external trigger, 1.4 V blanking
Bandwidth: Maximum bandwidth. Phase error at 1 MHz: < 0.5 degree

Acquisition system
EDUX1002A/EDUX1002G DSOX1102A/DSOX1102G
DSOX1204A/DSOX1204G
Maximum sample rate 1 GSa/s 2 GSa/s
Maximum analog channels 100 kpts 1 Mpts
record length
Acquisition mode Normal Default mode Default mode
Peak Detect Capture glitches as narrow as 10 ns at all time base Capture glitches as narrow as 10 ns at all time base
settings settings
Capture glitches as narrow as
5 ns at all time base settings (100 MHz model)
2.5 ns at all time base setting (200 MHz model)
Averaging Selectable from 2, 4, 8, 16, 64, ... to 65,536 Selectable from 2, 4, 8, 16, 64, ... to 65,536
High Resolution Real-time boxcar averaging reduces random noise Real-time boxcar averaging reduces random noise
and effectively increases vertical resolution to 12 bits and effectively increases vertical resolution to 12
of resolution when ≥ 20 μs/div at 1 GSa/s bits of resolution when ≥ 20 μs/div at 2 GSa/s

Segmented Not available Segmented memory optimizes available memory


for data streams that have long dead times
between activity. Maximum segments = 50. Re-arm
time = 19μs (minimum time between trigger events)

Time mode Normal Default mode Default mode


Roll Displays the waveform moving across the screen from Displays the waveform moving across the screen from
right to left. Available at the time base 50 ms/div or right to left. Available at the time base 50 ms/div or
slower slower
XY Displays the volts-versus-volts display Displays the volts-versus-volts display
X = Channel 1, Y = Channel 2 X = Channel 1, Y = Channel 2
Z = External trigger, 1.4 V blanking Z = External trigger, 1.4 V blanking
Phase error at 1 MHz: < 0.5 degree Phase error at 1 MHz: < 0.5 degree
Autoscale Finds and displays all active channels and external Finds and displays all active channels and external
trigger. Sets edge trigger mode on external trigger trigger. Sets edge trigger mode on external trigger
first then highest numbered active channel. Sets first then highest numbered active channel. Sets
vertical sensitivity. Sets time base to display ~ 1.8 vertical sensitivity. Sets time base to display ~ 1.8
periods. Requires minimum voltage of 10 mVpp periods. Requires minimum voltage of 10 mVpp
(channel) (channel)

4. Denotes warranted specifications; All others are typical. Specifications are valid after a 30-minute warm-up period and from ± 10 °C user calibration temperature.

Find us at www.keysight.com Page 16


Performance Characteristics (continued)
Trigger system
All Models
Trigger sources Analog channels, line 5, external, WaveGen, WaveGen modulation FM/FSK
Trigger modes Normal (triggered): Requires trigger event for oscilloscope to trigger
Auto: Triggers automatically in absence of a trigger event
Single: Triggers only once on a trigger event
Force: Front panel button that forces a trigger
Trigger coupling DC: DC coupled trigger
AC: AC coupled trigger, cutoff frequency: ~ 10 Hz
HF reject: High frequency reject, cutoff frequency ~ 50 kHz
LF reject: Low frequency reject, cutoff frequency ~ 50 kHz
Noise reject: Selectable OFF or ON, decreases sensitivity 2x
Trigger holdoff range 60 ns to 10 s

Trigger sensitivity

EDUX1002A/EDUX1002G DSOX1102A/DSOX1102G DSOX1204A/DSOX1204G


Internal 6 Greater of: Greater of: Greater of:
0.6 div or 2.5 mV (≤ 10 MHz) 0.6 div or 2.5 mV (≤ 10 MHz) 0.6 div or 2.5 mV (≤ 10 MHz)
0.9 div or 3.8 mV (10 to 50 MHz) 0.9 div or 3.8 mV (10 to 70 MHz) 0.9 div or 3.8 mV (10 to 70 MHz)
1.2 div or 5 mV (70 to 100 MHz) 1.2 div or 5 mV (70 to 200 MHz)
External ≤ 10 MHz: 250 mVpp ≤ 10 MHz: ≤ 10 MHz:
50 mVpp (1.6 V range) 20 mVpp (1.6 V range)
250 mVpp (8 V range) 100 mVpp (8 V range)
10 to 50 MHz: 500 mVpp 10 to 100 MHz: 10 to 200 MHz:
100 mVpp (1.6 V range) 100 mVpp (1.6 V range)
500 mVpp (8 V range) 500 mVpp (8 V range)

Trigger level range

EDUX1002A/EDUX1002G DSOX1102A/DSOX1102G
DSOX1204A/DSOX1204G
Internal ± 6 div from center screen ± 6 div from center screen
External 7 ±8V ± 1.6 V or ± 8 V selectable

5. Line trigger to ≤ 60 Hz.


6. Denotes warranted specifications; All others are typical. Specifications are valid after a 30-minute warm-up period and from ± 10 °C firmware calibration temperature.
7. Input voltage must remain within these limits for proper operation.

Find us at www.keysight.com Page 17


Performance Characteristics (continued)
Trigger type selections
EDUX1002A/EDUX1002G DSOX1102A/DSOX1102G
DSOX1204A/DSOX1204G
Trigger types Edge, pulse width, video, pattern/state Edge, pulse width, video, rise/fall time, setup and hold,
pattern/state
Edge Trigger on a rising, falling, alternating or either edge of any source
Pattern/state Trigger when a specified pattern/state on any combination inputs is entered8
Pulse width Trigger on a pulse of a selected channel with a time duration that is ‘less than a value,’ ‘greater than a value’
or ‘inside a time range’
Range minimum: 10 ns, 10 s max
Setup and hold Not available Trigger and clock/data setup and/or hold time violation.
Setup time can be set from –7 ns to 10 s.
Hold time can be set from 0 s to 10 ns

Rise/fall time Not available Trigger on rise-time or fall-time edge speed violations (<
or >) based on a user-selectable threshold
Select from (< or >) and time settings range between
Minimum: 5 ns Maximum: 10 s
Video Trigger on all lines or individual lines; odd/even or all fields from the composite video; or broadcast standards
(NTSC, PAL, SECAM, and PAM-M)
I2C Trigger at a start/stop condition or user-defined frame with address and/or data values. Also, trigger on
– EDUX1EMBD option missing acknowledge, restart, EEPROM read and 10-bit write
– DSOX1EMBD option
– D1200EMBA option
RS-232/422/485/UART Trigger on Rx or Tx start bit, stop bit, data content or parity error
– EDUX1EMBD option
– DSOX1EMBD option
– D1200EMBA option
SPI Not available Trigger on SPI (Serial Peripheral Interface) data
– DSOX1EMBD option pattern during a specific framing period. Supports
– D1200EMBA option positive and negative chip select framing as well
as clock idle framing. Supports MOSI or MISO (4-
channel models) data as half duplex data

CAN Not available Trigger on CAN (controller area network) version


– DSOX1AUTO option 2.0A and 2.0B signals. Trigger on the start of
– D1200AUTA option frame (SOF) bit, remote frame ID (RTR), data
frame ID (~RTR), remote or data frame ID, data
frame ID and data, error frame, all errors,
acknowledge error, and overload frame.
LIN Not available Trigger on LIN (Local Interconnect Network) sync
– DSOX1AUTO option break, sync frame ID or frame ID and data, parity error,
– D1200AUTA option checksum error and frame
8. The pattern must have stabilized for a minimum of 5 ns to qualify as a valid trigger condition.

Find us at www.keysight.com Page 18


Performance Characteristics (continued)
Waveform measurements
All Models
Cursors Single cursor accuracy: ± [DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]
Dual cursor accuracy: ± [DC vertical gain accuracy + 0.5% full scale]
Units: Seconds(s), Hz (1/s), phase (degrees)
Automatic measurements Measurements continuously updated with statistics.
Cursors track last selected measurement. Select up to four measurements from the list below:
Snapshot: Measure all single waveform measurements (24)
Voltage:
Peak-to-peak, maximum, minimum, amplitude, top, base, overshoot, pre-shoot, average- N cycles,
average-full screen, DC RMS-N cycles, DC RMS-full screen, AC RMS-N cycles, AC RMS-full screen (standard deviation)
Time:
Period, frequency, counter, + width, - width, +duty cycle, -duty cycle, bit rate, rise time, fall time, delay, phase,
X at min Y, X at max Y
Automatic measurement logging:
Available via BenchVue BV0004B

Waveform math
All Models
Arithmetic Add, subtract, multiply, divide, FFT (magnitude), FFT (phase), low-pass filter
FFT Record Size: Up to 64 kpts resolution
Window types: Hanning, Flat top, Rectangular, Blackman-Harris

Find us at www.keysight.com Page 19


Performance Characteristics (continued)
WaveGen – Built-in function generator (specifications are typical)
Note: Only available on WaveGen models EDUX1002G, DSOX1102G, and DSOX1204G. WaveGen is not upgradeable.
EDUX1002G/ DSOX1102G/ DSOX1204G
WaveGen out Front-panel BNC connector
Waveforms Sine, square, ramp, pulse, DC, noise
Modulation Modulation types: AM, FM, FSK
Carrier waveforms: Sine, ramp
Modulation source: Internal (no external modulation capability)

AM:
– Modulation: sine, square, ramp
– Modulation frequency: 1 Hz to 20 kHz
– Depth: 0 to 100%

FM:
– Modulation: sine, square, ramp
– Modulation frequency: 1 Hz to 20 kHz
– Minimum carrier frequency: 10 Hz
– Deviation: 1 Hz to carrier frequency or (2e12 / carrier frequency), whichever is smaller

FSK:
– Modulation: 50% duty cycle square wave
– FSK rate: 1 Hz to 20 kHz
– Hop frequency: 2 x FSK rate to 10 MHz
Sine Frequency range: 0.1 Hz to 20 MHz
Amplitude flatness: ± 0.5 dB (relative to 1 kHz)
Harmonic distortion: —40 dBc
Spurious (non-harmonics): —40 dBc
Total harmonic distortion: 1%
SNR (50 Ω load, 500 MHz bandwidth): 40 dB (typical); 30 dB (min)
Square wave /pulse Frequency range: 0.1 Hz to 10 MHz
Duty cycle: 20 to 80%
Duty cycle resolution: Larger of 1% or 10 ns
Pulse width: 20 ns minimum
Rise/fall time: 18 ns (10 to 90%)
Pulse width resolution: 10 ns or 5 digits, whichever is larger
Overshoot: < 2%
Asymmetry (at 50% DC): ± 1% ± 5 ns
Jitter (TIE RMS): 500 ps
Ramp /triangle wave Frequency range: 0.1 Hz to 200 kHz
Linearity: 1%
Variable symmetry: 0 to 100%
Symmetry resolution: 1%
Noise Bandwidth: 20 MHz typical

Find us at www.keysight.com Page 20


Performance Characteristics (continued)
WaveGen – Built-in function generator (specifications are typical) (continued)
Note: Only available on WaveGen models EDUX1002G, DSOX1102G, and DSOX1204G. WaveGen is not upgradeable.
EDUX1002G/ DSOX1102G/ DSOX1204G
Frequency Sine wave and ramp accuracy:
130 ppm (frequency < 10 kHz)
50 ppm (frequency > 10 kHz)

Square wave and pulse accuracy:


[50 + frequency/200] ppm (frequency < 25 kHz)
50 ppm (frequency ≥ 25 kHz)

Resolution: 0.1 Hz or 4 digits, whichever is larger


Amplitude Square, Pulse, Ramp:
2 mVpp to 20 Vpp into Hi-Z (offset ≤ ±0.4 V)
1 mVpp to 10 Vpp into 50 Ω (offset ≤ ±0.4 V)
50 mVpp to 20 Vpp into Hi-Z (offset > ±0.4 V)
25 mVpp to 10 Vpp into 50 Ω (offset > ±0.4 V)
Sine:
2 mVpp to 12 Vpp into Hi-Z (offset ≤ ± 0.4 V)
1 mVpp to 9 Vpp into 50 Ω (offset ≤ ± 0.4 V)
50 mVpp to 12 Vpp into Hi-Z (offset > ± 0.4 V)
25 mVpp to 9 Vpp into 50 Ω (offset > ± 0.4 V)
Resolution: ≤ 1% of the amplitude
Accuracy: 2% (Frequency = 1 kHz)
DC offset Square, Pulse, Ramp:
± [10 V – ½ amplitude] into Hi-Z
± [5 V – ½ amplitude] into 50 Ω
Sine:
± [8 V – ½ amplitude] into Hi-Z
± [4.5 V – ½ amplitude] into 50 Ω
Resolution: Larger of 250 uV or 3 digits
Accuracy: ± 1.5% of offset setting ± 1.5% of amplitude ± 1 mV
Main output Impedance: 50 Ω typical
Isolation: Not available, main output BNC is grounded
Protection: Overload automatically disables output
Sine, square, ramp, pulse, DC, noise

Find us at www.keysight.com Page 21


Performance Characteristics (continued)
Digital voltmeter (specifications are typical)
All Models
Functions ACrms, DC, DCrms
Resolution ACV/DCV: 3 digits
Measuring rate 100 times/second
Autoranging Automatic adjustment of vertical amplification to maximize the dynamic range of measurements
Range meter Graphical display of most recent measurement, plus extrema over the previous 3 seconds

Frequency counter (specifications are typical)


All Models
Functions Frequency
Resolution 5 digits
Measuring rate 100 times/second
Autoranging Automatic adjustment of vertical amplification to maximize the dynamic range of measurements
Range meter Graphical display of most recent measurement, plus extrema over the previous 3 seconds

Frequency response analysis (Bode plot) (specifications are typical)


EDUX1002G/ DSOX1102G/ DSOX1204G
Dynamic range > 80 dB (typical)
Input and output sources Output: WaveGen out
Input 1 and 2 can be assigned to any channel
Frequency range 10 Hz to 20 MHz
Number of test points Up to 1,000 total points
Test amplitude 10 mVpp to 9 Vpp into 50-Ω
Fixed amplitude across the entire sweep
Test results Logarithmic overlaid gain and phase plot
Manual measurements A single pair of tracking gain and phase markers
Plot scaling Auto-scaled during test and manual

Environmental
Connectivity
EDUX1002A/EDUX1002G/DSOX1102A/DSOX1102G
Standard Ports One USB 2.0 hi-speed device port on rear panel. Supports USBTMC protocol
One USB 2.0 hi-speed host port on front panel. Supports memory devices, printers, and keyboards

DSOX1204A/DSOX1204G
Standard Ports One USB 2.0 hi-speed device port on rear panel. Supports USBTMC protocol
One USB 2.0 hi-speed host port on front panel. Supports memory devices
One Ethernet 1 Gb/s networking: RJ-45

Find us at www.keysight.com Page 22


General and environmental characteristics
All Models
Power line consumption 50 W max
Power voltage range 100 to 120 V, 50/60/400 Hz; 100 to 240 V, 50/60 Hz
Environmental rating 0 to +50 °C, 3,000 m Max
Maximum Relative Humidity (non-condensing): 95%RH up to 40°C, decreases linearly to 45%RH at 50°C 9
Electromagnetic compatibility Meets EMC directive (2004/108/EC), meets or exceeds IEC 61326-1:2005/EN61326-1:2013 (basic)
IEC 61000-4-2/EN 61000-4-2
IEC 61000-4-3/EN 61000-4-3
IEC 61000-4-4/EN 61000-4-4
IEC 61000-4-5/EN 61000-4-5
IEC 61000-4-6/EN 61000-4-6
IEC 61000-4-8/EN 61000-4-8
IEC 61000-4-11/EN 61000-4-11
Canada: ICES/NMB-001:2006
Australia/New Zealand: AS/NZS CISPER 11:2011
Safety ANSI/UL Std. No. 61010-1:2012; CAN/CSA-C22.2 No. 61010-1-12
ANSI/UL Std. No. 61010-2-030:2012; CAN/CSA-C22.2 No. 61010-2-030-12
Dimensions (W x H x D) 314 mm (12.4 in) x 165 mm (6.5 in) x 130 mm (5.1 in)
Weight Net: 3.23 kg (7.1 lbs), shipping: 4.2 kg (9.2 lbs)
Display 7.0” diagonal color TFT LCD WVGA

Nonvolatile storage
All Models
Reference waveform display Two internal waveforms or USB thumb drive
Waveform storage Set up, .bmp, .png, .csv, ASCII XY, reference waveforms, .bin, mask, HDF5
Max USB flash drive size Supports industry standard flash drives
Setups without USB flash drive 10 internal setups
USB drive format FAT32
NTFS, EXT2/3/4 (DSOX1204A/G only)

9. From 40 °C to 50 °C, the maximum % Relative Humidity follows the line of constant dew point.

Learn more at: www.keysight.com


For more information on Keysight Technologies’ products, applications or services,
please contact your local Keysight office. The complete list is available at:
www.keysight.com/find/contactus

Find us at www.keysight.com Page 23


This information is subject to change without notice. © Keysight Technologies, 2018, Published in USA, December 18, 2018, 5992-3484EN

You might also like