International Journal of PharmTech Research
CODEN (USA): IJPRIF, ISSN: 0974-4304
                                                                          Vol.9, No.3, pp 400-405,     2016
                  Qualification of Tunnel Sterilizing Machine
                                Ram Mohan S.R, N. Vishal Gupta*
         Pharmaceutical Quality Assurance group, Department of Pharmaceutics,
        JSS College of Pharmacy, JSS University, Sri Shivarathreeshwara Nagara,
                           Mysuru – 570015, Karnataka, India
        Abstract: Depyrogenation devices, such as tunnels, are used in the pharmaceutical industry to
        prepare components for aseptic filling. To qualify such devices, various pharmacopoeias
        require depyrogenation devices to be periodically challenged with high levels of bacterial
        endotoxin. Although the pharmacopoeias state the acceptance criteria, little consideration is
        given to the practical approach. This work discusses the theoretical concept of depyrogenation
        and the various tests performed for the qualification of Depyrogenation Tunnels.
        Key words: Depyrogenation, Bacterial Endotoxin, Performance Qualification.
Introduction
         Depyrogenation is an important part of the manufacture of pharmaceutical products and is distinct from
sterilization. Sterilization refers to the destruction of living cells. However, the process does not necessarily
destroy microbial by-products and toxins. Endotoxin is one toxin that is extremely heat stable and is not
destroyed by standard sterilization cycles (e.g., autoclaving). If only sterilization is required to be demonstrated,
this can be achieved using biological indicators impregnated with endospores from a heat resistant bacteria
(e.g., Bacillus subtilis var. niger [often used for dry heat] or Geobacillus stearothermophilus [often used for
moist heat, although the microorganism also has a high resistance to dry heat]. 2
        Depyrogenation by dry heat for glass in the pharmaceutical industry is the primary endotoxin
destruction method used. This process both sterilizes and depyrogenates and is mainly used for glass
components. Dry heat involves subjecting the components to a high level of heat (normally between 180 and
250∘C) for a defined time (the higher the temperature, the shorter the time required). The typical cycle is 250∘C
for not less than 30 minutes. For example, the European Pharmacopoeia in chapter 2.6.8 states two possible
time-temperature combinations for depyrogenation: 60 minutes at 200∘C or 30 minutes at 250∘C. A quantity of
endotoxin destroyed at 250∘C for 60 minutes would not necessarily be totally destroyed at 200∘C at 60 minutes,
based on the non-linearity of the thermal destruction curve. Endotoxin destruction at low temperature is of the
second-order.2
         Depyrogenation dry heat devices include ovens and tunnel sterilizers. To operate, depyrogenation de-
vices require a series of parameters to be controlled. These parameters include laminar airflow controlled by
high-efficiency particulate air (HEPA) filters, with a specification for air velocity and particulates. Where the
device is a depyrogenation tunnel, the rate of speed (e.g., minimum, maximum, and nominal) must be measured
and verified. The key function for depyrogenation is temperature control. Such depyrogenation devices require
qualifying as part of validation. This is performed along the familiar lines of design qualification, installation
qualification, operational qualification, and performance qualification, as well as annual re-qualifications. A
depyrogenation study is a test of the physical capabilities of a device to depyrogenate an article or device. It is
demonstrated by physical measurements (including temperature) and biological (using bacterial endotoxin). 2
N. Vishal Gupta et al / International Journal of PharmTech Research, 2016,9(3),pp 400-405.                     401
        As part of the validation, normally at the performance qualification stage, depyrogenation devices are
biologically challenged using a known level of a high concentration of Escherichia coli endotoxin. The
preparation used is a freeze-dried extract from the Gram-negative bacterial cell wall lipopolysaccharide (LPS).
The preparation is similar to the control standard endotoxin (CSE) used for routine LAL testing, although the
concentration, once reconstituted, is far greater.2
Qualification 3
Design qualification
        The first element of the validation of new facilities, systems or equipment could be design qualification
(DQ).
        The compliance of the design with GMP should be demonstrated and documented.
Installation qualification
Installation qualification (IQ) should be performed on new or modified facilities, systems and equipment.
IQ should include, but not be limited to the following:
(a) Installation of equipment, piping, services and instrumentation checked to current engineering drawings and
specifications;
(b) Collection and collation of supplier operating and working instructions and maintenance requirements;
(c) Calibration requirements;
(d) Verification of materials of construction.
Operational qualification
Operational qualification (OQ) should follow Installation qualification.
OQ should include, but not be limited to the following:
(a) Tests that have been developed from knowledge of processes, systems and equipment;
(b) Tests to include a condition or a set of conditions encompassing upper and lower operating              limits,
sometimes referred to as “worst case” conditions.
        The completion of a successful Operational qualification should allow the finalisation of calibration,
operating and cleaning procedures, operator training and preventative maintenance requirements. It should
permit a formal "release" of the facilities, systems and equipment.
Performance qualification
        Performance qualification (PQ) should follow successful completion of Installation qualification and
Operational qualification.
        PQ should include, but not be limited to the following:
(a) Tests, using production materials, qualified substitutes or simulated product, that have been developed from
knowledge of the process and the facilities, systems or equipment;
(b) Tests to include a condition or set of conditions encompassing upper and lower operating limits.
Although PQ is described as a separate activity, it may in some cases be appropriate to perform it in conjunction
with OQ.
Qualification of established (in-use) facilities, systems and equipment
        Evidence should be available to support and verify the operating parameters and limits for the critical
variables of the operating equipment. Additionally, the calibration, cleaning, preventative maintenance,
operating procedures and operator training procedures and records should be documented.
N. Vishal Gupta et al / International Journal of PharmTech Research, 2016,9(3),pp 400-405.                          402
                                              1
Process for flow of sterilization tunnel
Washed glass vials
Drying zone
Sterilizing zone
Cooling zone
Filling table
Test and Its Rationale
Table-1: Tests performed and its Rationale
 Sl.No.                     Test                                              Rationale
                                                  The purpose of this test is to measure airflow velocity and
      1       Air flow Velocity
                                                  uniformity, and supply airflow rates through the HEPA filter.
                                                  The purpose of this test is to confirm that the filter system is
      2       Filter system leakage Test
                                                  properly installed and that leaks have not developed during use.
              Tunnel Belt / Conveyor speed        To ensure the tunnel conveyor belt speed meets the requirements
      3
              verification                        as specified by vendor.
                                                  The purpose of this test is to provide acleanliness in the supplied
      4       Nonviable Particle Count
                                                  air.
              Heat penetration and                To ensure and establish the heat Penetration and endotoxin log
      5
              Endotoxin challenge study           reduction efficiency of the Tunnel Sterilizer
Tests, Objective, Procedure and its Acceptance Criteria 1, 4
1. Air velocity
1.1 Objective
          To determine that factors that affect cross-sectional air velocity distribution in tunnel-ventilated system
and is capable of delivering air velocities, as per the requirement to maintain continuous laminarity of HEPA
filter installed in tunnel.
1.2 Equipment used
Hot air anemometer
1.3 Procedure
  ·       This test shall be performed by trained person and training record should be attached in report. Performed
          at least 30 minute.
  ·       Measure the velocity above the conveyor for the different zone of tunnel sterilizer and measure the air
          velocity 6 inches below filter.
  ·       Take the velocity of air at five locations (on centre and four corners) of each zones of sterilizer tunnel.
          Calculate average velocity for each filter
  ·       If velocity is not within the limit, inform the manufacturer of the sterilizing tunnel for corrective action.
1.4 Acceptance criteria
   Air velocity should be maintained within 90 fpm ± 20% of mean unit velocity for even distribution of
temperature.
N. Vishal Gupta et al / International Journal of PharmTech Research, 2016,9(3),pp 400-405.                      403
2. Filter system leakage test
2.1 Objective
          To verify the integrity of HEPA filter installed in the sterilization and depyrogenation tunnel. HEPA
filter installation has been done properly and qualifies the filter integrity test.
2.2 Equipment used
Aerosol generator
Aerosol photometer
2.3 Procedure
  ·   Place the aerosol generator to introduce an aerosol challenge upstream of the HEPA filter in zone wise
      manner in concentration of 80-120mg/m3 of air by opening appropriate number of nozzles
  ·   Measure upstream concentration of aerosol by using zone wise upstream (in feed zone, hot zone 1, hot
      zone 2 and cooling zone)
  ·   Adjust the photometer gain/span control for full scale deflection on 100% range
  ·   Scan the downstream side of the HEPA filter, its perimeter, the seal between the filter frame and grid
      structure including its joints using overlapping strokes with the photometer probes
  ·   The photometer probes should move at transverse rate not more than 10ft/minute with sample flow rate of
      1cft/min ±10%
  ·   If any leak is more than the specified limit, the above test should be repeated after taking the
      recommended corrective action
2.4 Acceptance criteria
       Photometer reading downstream of the HEPA filtration unit caused by the leakage should be less than
0.01% of the upstream challenge concentration of the aerosol 100%
3. Tunnel belt/conveyor speed verification
3.1 objective
To ensure the tunnel conveyor belt speed meets the requirements as specified
3.2 Equipment used
Vernier calliper
3.3 Procedure
  ·   Mark the start position and advance signal of the conveyor belt
  ·   Start the conveyor belt
  ·   Start the stopwatch when advance signal reaches the start position and run for 1 minute
3.4 Acceptance Criteria
Conveyor speed shall not vary more than 3%of the set speed
4. Nonviable Particle Count
4.1 Objective
         To establish that at different location within the tunnel, count size of particle per cubic meter is within
the limit.
N. Vishal Gupta et al / International Journal of PharmTech Research, 2016,9(3),pp 400-405.                      404
4.2 Procedure
The particle count test should be performed by qualified or trained person
  ·   Start blower of the sterilizing tunnel
  ·   Calculate the number of location by the following formula
  ·   Number of sampling location NL =
  ·   Whereas; the minimum number of sampling locations
  ·   Switch on particle counter and place the iso-kinetic suction probes at specified location under the filter of
      conveyor belt of tunnel and observe the reading, record in reports
  ·   Take the particle counts for all zones of sterilizing tunnel
4.3 Acceptance Criteria
        The particle counts taken under the HEPA filter in the different zones of sterilizing tunnel should meet
the requirement of ISO 5/class A.
5. Heat penetration and Endotoxin challenge study
5.1 Objective
         To ensure that heat is sufficiently penetrating into the inner most portion of the vial subjected for
sterilization and depyrogenation to achieve desired temperature during the sterilization and depyrogenation
cycle. The recovery of endotoxin concentration after exposing to depyrogenation tunnel should show more than
3 log reduction.
5.2 Procedure
  ·   Get the 9/10 spiked vial with approx. 10,000 EU/vial of bacterial endotoxin from microbiology
  ·   Place minimum 10 number of probes, one probe each inside the endotoxin spiked 8 vials and 3 without
      spiked vials at the junction of the bottom of the container and side wall. The containers inner surface
      should be in contact with the probe because for sterilization and depyrogenation of the inner walls of the
      container as well as inner space. Tie the probes firmly with the vial and place these vial inside the washed
      vial load
  ·   Use zig to hold the spiked vials containing probes in place, as vial travel through the tunnel
  ·   Set the temperature/cycle condition as per set parameter
  ·   Record the set parameter for the sterilization cycle operated during test
  ·   Operate the tunnel and pass the endotoxin spiked vials along with the washed vials as per standard
      operating procedure and start the data logger to record the actual temperature inside within the
      sterilization zone
  ·   When the vial attached with temperature indicating probes cross the sterilization zone, stop the conveyor
      belt of sterilizing tunnel, switch off the data logger and pull out the probes. Wrap the exposed endotoxin
      indicator vials with aluminum foil and label properly
  ·   Send the exposed vials to microbiology lab for testing of residual endotoxin in the vials after sterilization
      as per standard procedure
  ·   Record the result and take validation run for each set of vial normally used in routine production with
      complete load and re-validation one run on rotation for different type of vial size
  ·   Record the temperature observation at different location.
5.3 Acceptance Criteria
     All temperature measured in the chamber is ≥ 3000C. The recovery of endotoxin concentration after in
sterilization and depyrogenation should at least 3 log reductions
Conclusion
N. Vishal Gupta et al / International Journal of PharmTech Research, 2016,9(3),pp 400-405.                    405
         Depyrogenation forms part of a critical process in many pharmaceutical production facilities,
particularly where glass vials and bottles are required for aseptic filling operations. The number of validation
runs is commonly set at three in order to demonstrate reproducibility, but this number is not fixed. The
frequency of re-validation is to be determined by the user based on risk assessment.
References
  1.    Sachin J.S, Pritam S.J, Nikita K.K, Critical review on qualification of sterilization equipment in aseptic
        processing. J. Pharm. Biosci, 2014; 4(1); 24-35. Available at: www.jpbs-online.com
  2.    Tim S. A Practical Approach to Depyrogenation Studies Using Bacterial Endotoxin. J GXP
        Compli. 2011; 15(4): 90-96. Available at: www.ivtnetwork.com
  3.    EU Guideline for Good Manufacturing Practice for Medicinal Products for Human and Veterinary Use,
        Annex 15: Qualification and Validation, 1 October 2015, Available at: ec.europa.eu
  4.    U.S. Validation Services- Depyrogenation Tunnel. 2016. Available at: www.usvalidation.com
  5.    European Pharmacopeia 8.0, General Notes (1), 3.2.1 Glass containers for pharmaceutical use, Page no
        409. Available at: online6.edqm.eu
  6.    European Pharmacopeia 8.0, General Notes (1), 2.6.8 Pyrogens, Page no 183. Available at:
        online6.edqm.eu
  7.    Guideline for industry, Sterile Products Produced by Aseptic Processing-cGMP, 2004, Available at:
        www.fda.gov
  8.    WHO Technical Report Series No 937, Annex 4: Supplementary Guideline on Good Manufacturing
        Practices: Validation, 2006, Available at: apps.who.int
  9.    SCHEDULE M: Part-1 Good Manufacturing Practices for Premises and Materials, Available at:
        www.cdsco.nic.in
                                                   *****