0% found this document useful (0 votes)
105 views20 pages

Usp 50-07-30-00-00

The document provides release notes for microcode version 50-07-30-00/00 released on May 14, 2006. Key updates include: 1. Support for additional external storage systems without hard disk drives loaded including Sun Storage systems and new Fibre Channel printed circuit boards with higher speeds. 2. Enhancements to the mainframe system including 4x4 replication between primary and secondary systems for maintaining data consistency. 3. Updates to the open system including support for new Fibre Circuit boards, enhanced snapshot functionality without hard disk drives loaded, and improvements to the RAID management software. 4. Fixes issues with the system option mode output, port attribute setting, fibre channel configuration panel display

Uploaded by

imkzby
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
105 views20 pages

Usp 50-07-30-00-00

The document provides release notes for microcode version 50-07-30-00/00 released on May 14, 2006. Key updates include: 1. Support for additional external storage systems without hard disk drives loaded including Sun Storage systems and new Fibre Channel printed circuit boards with higher speeds. 2. Enhancements to the mainframe system including 4x4 replication between primary and secondary systems for maintaining data consistency. 3. Updates to the open system including support for new Fibre Circuit boards, enhanced snapshot functionality without hard disk drives loaded, and improvements to the RAID management software. 4. Fixes issues with the system option mode output, port attribute setting, fibre channel configuration panel display

Uploaded by

imkzby
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 20

USP

MICROCODE VERSION 50-07-30-00/00


RELEASED 05/14/06

Newly supported features and functions for Version 50-07-30-00/00


1. Mainframe & OPEN System
1-1 UR/URZ without HDD Loaded
Description The external volume of an external storage has been available to be used as a journal volume
of Universal Replicator/ Universal Replicator for ZOS
Changed Part DKCMAIN
Note 1. Required program products:
Universal Volume Manager
Universal Replicator/ True Copy (Sync/Async) or Universal Replicator for ZOS/ True Copy
for ZOS (Sync/Async)
2. Installing expansion SM option 1 is required.
1-2 Write Pending Prevented on UVM Virtual Volume when Link Down
Description With previous version, if Link Down occurs at all the paths between the RAID500 and
external storages, since the data cannot be transferred to the external volumes when write I/Os
are received, the data has to be written into the cache so that the Write Pending data is
accumulated and the cache is in heavily loaded state.
Since this version, a pseudo cache overloaded state is created in this case so that the host I/O
inflow can be limited and the Write Pending data can be prevented from being accumulated.
The feature is only available for the external virtual volume (unavailable for internal
volumes).
Changed Part DKCMAIN
Note 1. It is required to set system option mode 497 to ON to enable the feature.
2. In cases of using Shadow Image/ Shadow Image for ZOS/ Copy on Write Snapshot/ FCv2/
FCv1,
A. The feature is unavailable if a copy operation working with a host I/O is performed,
B. The feature is available if the background copy operation is performed.
3. The feature is unavailable in cases of using the R-VOL of True Copy Async/ True Copy for
ZOS Async or the JNL-VOL of Universal Replicator/ Universal Replicator for ZOS.
1-3 Enhancement for Sun Storage Systems
Description 1. Sun StorEdge 3510 has been supported as an external storage subsystem
2. Sun StorEdge 6130 has been supported as an external storage subsystem
3. The Active/Passive mode of Sun StorEdge 6120/6320 supported
Changed Part DKCMAIN
Note None
1-4 Support for Sun StorageTek Flex380
Description Sun StorageTek Flex380 supported as an external storage subsystem.
Changed Part DKCMAIN

2. Mainframe System
2-1 4 x 4 Universal Replicator for ZOS
Description The remote copy from any of primary subsystems (up to two) to any of secondary subsystems
(up to two) has been available while maintaining data consistency.
Changed Part DKCMAIN
Note 1. The program products of Universal Replicator for ZOS and True Copy for ZOS
(Sync/Async) are required to enable the feature
2. V07 only supports 2 x 2 Universal Replicator for ZOS
HDS Confidential 1 of 20
3. Open System

3-1 Support for 8FS2R/16FS2R/32FS2R PCBs


Description Fibre channel PCBs whose channel transfer speed is 4 GBPS supported.
1. CB models and numbers of ports are as follows:
8FS2R: 4 ports, 16FS2R: 8 ports, 32FS2R: 16 ports
2. The 4 GBPS PCB can be replaced with the 2 GBPS PCB non-disruptively
3. 32FS2R and 32FSR can be replaced each other
4. Connectivity leveraged within the supported range of 32FSR.
Changed Part DKCMAIN/ SVP/ Storage Navigator
Note 1. In case of replacing different PCB models, make sure to replace one set (two pieces)
together. If different models coexist in this case, the maintenance operations, such as micro-
program exchange, will fail
2. In case of replacing 32FS2R with 32FSR, SIM=3999 is output. Since the performance is
degraded, please insert 32FS2R back if you do not replace it on purpose

3-2 Copy-on-Write Snapshot without HDD Loaded


Description The external LU used as Pool-VOL of Copy-on-Write Snapshot is prevented from being
disconnected when in the following status:
1. PSUS status
2. In restore progress
In case of disconnecting the external LU, it is required to resync or delete the Copy-on-Write
Snapshot pair. In addition, if the pair is in restore progress; make sure to perform Disconnect
after the restore operation.
3. The external LU used as a Pool-VOL is prevented from being deleted.
In case of deleting the external LU, it is required to delete the Pool-VOL containing the
external LU to be deleted first, and then delete the external LU.
Changed Part DKCMAIN
Note 1. Installing VFS Sys Area is required.
2. In case of the external volume being used as a Pool-VOL, the micro-program exchange
from version 50-07-30-00/00 or higher to a version lower than 50-07-30-00/00 will be
prevented (it is required to delete the Pool-VOL where an external volume is registered).

3-3 RAID Manager Enhancement


Description RAID Manager has been enhanced as follows:
1. Added the display of instance# using the command device to the output of 'horcctl -D'
option
2. Added '-I[H][M][inst#]' options to the all command that connects to HORCM
3. Added Solaris/x86 to the supported platform
4. Supported ISCSI interface for Windows
5. Supported the device discovery for ISCSI on AIX
6. Changed the command device I/O from RAW_IO to "ioctl()" for supporting AIX MPIO
7. Supported RAID Manager communication between AIX and Windows
Changed Part DKCMAIN/RAID Manager
Note None

HDS Confidential 2 of 20
The change of contents for Version 50-07-30-00/00
1 Printout Tool: System Option Mode output problem
Phenomena When Printout Tool is used, the mode may not be output to System
Option On in SysoptInfo.csv.
Severity (High, Medium, Low) Low
Conditions of Occurrence This problem occurs when all System Option Mode 0-31 are set to OFF
and any one of System Option Mode 32-1023 is set to ON.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 50-07-30/00
Category Printout Tool
Changed Part SVP

2 Improper port attribute setting


Phenomena In a 32HS PCB, when the high-speed mode is set in the CL1 Block A and
the standard mode is set in the CL2 Block A, if the attribute is set for the
ports in CL2 Block A, it is set for four ports, though it should be set for
two nonadjacent ports.
Severity (High, Medium, Low) Low
Conditions of Occurrence This problem occurs With all conditions met.
1. In a 32HS PCB, the high-speed mode is set in the CL1 Block A and
the standard mode is set in the CL2 Block A
2. Set attributes of the ports in CL2 Block-A
This phenomenon occurs also in Block-B/Block-C/Block-D.
Affected Products/Version SVP: 50-03-06/00 and higher
Fixed Product/Version SVP: 50-07-30/00
Category SVP
Changed Part SVP

3 Invalid Display in Fibre PCB Configuration Panel


Phenomena After selecting a port, if the Fibre PCB Mode in Block-C/Block-D is
changed, the Channel Speed/ Initiator Target button is enabled, though
the port is not selected.
Severity (High, Medium, Low) Low
Conditions of Occurrence This problem occurs when FibrePCBMode in Block-C/Block-D is
changed after a port is selected.
Affected Products/Version SVP: 50-03-06/00 and higher
Fixed Product/Version SVP: 50-07-30/00
Category SVP
Changed Part SVP

HDS Confidential 3 of 20
4 One cluster of CHA cannot be installed in NSC
Phenomena When a CHA is installed in an NSC model, if the one cluster
configuration of 32HS/32FSR is specified, the Next button will be
disabled.
Severity (High, Medium, Low) Low
Conditions of Occurrence This problem occurs when CHA is installed in only one cluster in an
NSC model.
Affected Products/Version SVP: 50-03-80/00 and higher
Fixed Product/Version SVP: 50-07-30/00
Category SVP
Changed Part SVP

5 ADD LU or DEL LU failed


Phenomena 1. An external LU specified in Add LU is not added to the configuration.
2. An external LU specified in Delete LU is not deleted from the
configuration.
Severity (High, Medium, Low) Medium
Conditions of Occurrence This problem occurs when volume numbers are divided into four groups
every 0x4000, and the total number of installed volumes in any three of
the groups exceeds 38*1024.

Where the number of installed volumes 0x0000-0x3fff is N0, that of


0x4000-0x7fff is N1, that of 0x8000-0xbfff is N2, and that of 0xc000-
0xfeff is N3, any of the following inequalities is satisfied.
N0+N1+N2 > 38*1024, N0+N1+N3 > 38*1024, N0+N2+N3 > 38*1024,
N1+N2+N3 > 38*1024
Affected Products/Version DKCMAIN: 50-06-04-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Universal Volume Manager
Changed Part DKCMAIN

6 HUR Pair Suspend when Replacing PDEV (SSB=EF62)


Phenomena When an update I/O is issued to an HUR pair, if replacing a PDEV of a
JNL-VOL at RCU, SSB=EF62 is output, and the HUR pair is suspended.
Severity (High, Medium, Low) Medium
Conditions of Occurrence This problem may occur With all conditions met.
1. An update I/O is issued to a UR Duplex pair. Alternatively, an initial
copy is in progress.
2. PDEV of a JNL-VOL at RCU is replaced.
Affected Products/Version DKCMAIN: 50-03-80-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Universal Replicator/ Universal Replicator for ZOS
Changed Part DKCMAIN

7 UR pair suspends due to a failure (SSB=EF62)


Phenomena When an update I/O is issued to an HUR pair, SSB=EF39 is output, and
HDS Confidential 4 of 20
then EF62 is output and the UR pair suspends due to a failure.
Severity (High, Medium, Low) Medium
Conditions of Occurrence This problem may occur With all conditions met.
1. An update I/O is issued to a UR Duplex pair. Alternatively, an initial
copy is in progress.
2. SSB=EF39 (Staging TOV) is output.
Affected Products/Version DKCMAIN: 50-03-60-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Universal Replicator/ Universal Replicator for ZOS
Changed Part DKCMAIN

8 Reset Failure of Internal JOB on MCU


Phenomena An internal JOB on MCU failed to be reset. As a result,
SSB=169B/16AC occurred.
Severity (High, Medium, Low) Medium
Conditions of Occurrence This problem may occur With all conditions met.
1. A job without ITL defined is in progress,
2. A reset is received in the Outbound Inactive status.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category OPEN
Changed Part DKCMAIN

9 Error during RMI server startup


Phenomena 1. An error (10 6027: Network Error) occurred when the user logged onto
Storage Navigator from the web browser.
2. An error (10 6027: Network Error) occurred when the Web Console
button was selected on the SVP.
Severity (High, Medium, Low) Low
Conditions of Occurrence Problem 1 occurs in rare cases when a LAN cable is removed while the
SVP is being rebooted, or when the LAN HUB is PS Off.
Problem 2 occurs in rare cases when the LAN cable is removed right
after the IP address of the SVP is changed, or when the LAN HUB is PS
Off.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 50-07-30/00
Category SVP/ Storage Navigator
Changed Part SVP

10 Support for command device protection feature


Phenomena When a horcmstart.sh command is executed, a RAID Manager message
"HORCM inst XX has failed to start." appears, and the RAID Manager
startup fails. SSB: B9C0 occurs.
HDS Confidential 5 of 20
Severity (High, Medium, Low) Low
Conditions of Occurrence This problem occurs With all conditions met 4096 times (Multiple
accesses are counted as one access as long as their HOST WWN, LBA,
and Port# are the same).
1. The target device is a command device.
2. LBA: F000-FFFF
3. TL=1 Read command
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category RAID Manager API
Changed Part DKCMAIN

11 Failed to collect LCP dump


Phenomena When a dump was collected, SSB=3902 occurred, and FCP-GN and
FCP-GQ were displayed in the DUMP NG dialog.
Severity (High, Medium, Low) Medium
Conditions of Occurrence With all conditions met, if [Normal], [Detail], or [Dump] is selected as
Auto Dump Type, SSB=3902 occurs, and the LCP dump for two ports
will fail.
1. 16HS/16FSR (FS2R) is installed in Option5, and CHA PCB is not
installed in Option6/7
a. Or 16HS/16FSR (FS2R) is installed in Option6, and CHA PCB is not
installed in Option5/7
b. Or 16HS/16FSR (FS2R) is installed in Option7, and CHA PCB is not
installed in Option5/6
2. A total number of MPs installed in CHA PCB Basic (Basic, Option1,
Option2, and Option3) is 48-64.
3. A total number of ports installed in CHA PCB Basic (Basic, Option1,
Option2, and Option3) are 80-88.
4. 24, 28, or 32 are obtained by subtracting the number of installed MPs
from the number of installed ports.
Fixed Product/Version SVP: 50-07-30/00
Category SVP
Changed Part SVP

12 [Export Tool] Problem in readme.txt


Phenomena Installation of Export Tool using the readme.txt file failed because the
path of the file in the CD-ROM was wrong.
Severity (High, Medium, Low) Low
Conditions of Occurrence This problem occurs when Export Tool is installed by referring to the
readme.txt file included in the Export Tool.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 50-07-30/00
Category Export Tool
Changed Part SVP

13 CHK1B/MP reboot due to blocked device during JNL transfer


Phenomena With the V04 version or later, JNL data was transferred to the next slot of
the target device, but the target device was blocked. As a result, CHK1B
occurred, and the MP was rebooted.
Severity (High, Medium, Low) Medium
Conditions of Occurrence This problem occurs With all conditions met.
HDS Confidential 6 of 20
1. HUR
2. An error occurred with RDJNL (LDEV blockade, PIN VOL detected
etc.)
Affected Products/Version DKCMAIN: 50-04-20-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Universal Replicator/ Universal Replicator for ZOS
Changed Part DKCMAIN

14 I/O Timeout during Correction Access


Phenomena During a correction access, an I/O timeout occurred with SSB=1699,
14dc, dd84, d034 reported. However, the I/O timeout could be recovered
after a retry.
Severity (High, Medium, Low) Low
Conditions of Occurrence This problem may occur With all conditions met.
- RAID5/RAID6
- OPEN-V
- Correction access
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category OPEN
Changed Part DKCMAIN

15 Failed to Delete UR/URZ Pairs (SSB=EA29)


Phenomena When performing Delete Pair for a master journal group (processing
range: group) after having performed Delete Pair for a restore journal
group (processing range: group), the operation failed with SSB=EA29
reported.
Severity (High, Medium, Low) Medium
Conditions of Occurrence This problem may occur With all conditions met.
1. Perform Delete Pair for a restore journal group (processing range: LU
or group),
2. All pairs belonging to the master journal group are suspended due to
Flush, Purge or a DKC internal failure,
3. After #2, perform Delete Pair for a master journal group (processing
range: group).
Affected Products/Version DKCMAIN: 50-04-49-00/03/ 50-05-26-00/00/ 50-05-45-00/00/ 50-06-
08-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Universal Replicator/ Universal Replicator for ZOS
Changed Part DKCMAIN

16 Performance Degradation during Data Reading and Writing


Phenomena Performance degradation possible when data is read and written at the
same time as a cache hit.
Severity (High, Medium, Low) Medium
Conditions of Occurrence This problem may occur With all conditions met.
- Cache hit
- Writing data is far less than reading data.
- Data is read from and written to the same extent.
HDS Confidential 7 of 20
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category OPEN
Changed Part DKCMAIN

17 Queuing I/O TOV problem


Phenomena A queuing I/O may be judged wrongly to have been timeout, and a Check
Condition may be reported.
Severity (High, Medium, Low) Low
Conditions of Occurrence This problem may occur when an OPEN host is connected.
Affected Products/Version DKCMAIN: 50-06-02-00/91 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category OPEN
Changed Part DKCMAIN

18 EC=982c occurred at the time of staging TOV


Phenomena At the time of staging TOV, EC=982c occurs wrongly.
Severity (High, Medium, Low) Low
Conditions of Occurrence This problem occurs when an I/O is timeout.
Affected Products/Version DKCMAIN: 50-06-02-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category OPEN
Changed Part DKCMAIN

Error (3 2009) when Volume to Space is performed from


19
Storage Navigator
1. When Volume to Space is performed from the LUSE/VLL panel in
Storage Navigator, error (3 2009) occurred.
Phenomena 2. Since the panel was grayed out after 1, tried to restart the Storage
Navigator, but (3 2009) occurred, and it could not be started.
(The same error occurred when this operation was performed from SVP)
Severity (High, Medium, Low) Medium
This problem occurs With all conditions met.
1. External LU is HDEV#0 in VDEV
Conditions of Occurrence
2. Top alternate path in the list for #1 is deleted
3. NSC model, or USP in which CHA Basic is not installed
Affected Products/Version SVP: 50-06-05/00 and higher
Fixed Product/Version SVP: 50-07-30/00
Category SVP
Changed Part SVP

Unnecessary configuration update during Cross-System Copy


20
operation
When a Cross-System Copy operation was performed, SVP performed
unnecessary configuration update operation. Until the update processing
Phenomena completed, Storage Navigator operations could not be performed, and
when the Shadow Image button etc. was selected, an error occurred
(DKC is in internal process, or configuration is being changed).
Severity (High, Medium, Low) Low
This problem occurs when Cross-system Copy pair is created or deleted,
Conditions of Occurrence
and the history is received.
HDS Confidential 8 of 20
Affected Products/Version SVP: All
Fixed Product/Version SVP: 50-07-30/00
Category SVP
Changed Part SVP

21 SSB=3332 occurred during I/O operation


When an I/O operation was being performed, SSB=3332 (SVP task reset
Phenomena
(No response for a fixed period)) occurred.
Severity (High, Medium, Low) Medium
This problem may occur when the option monitor is ON.
Conditions of Occurrence In addition, when this phenomenon occurs during communication
between DKC-SVP, a communication error may occur.
Affected Products/Version SVP: 50-06-05/00 and higher
Fixed Product/Version SVP: 50-07-30/00
Category SVP
Changed Part SVP New Communication

22 EC=c69a and EC=8631 When TCZ Sync pair operation


When a TC for ZOS Sync pair operation is performed, EC=c69a is
Phenomena
logged, and then EC=8631 is logged.
Severity (High, Medium, Low) Low
This problem occurs With all conditions met.
1. TCZ pair
Conditions of Occurrence
2. Host is FICON, and data is overwritten on one track
3. Heavy workload
Affected Products/Version DKCMAIN: 50-03-95-00/00, 50-04-02-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category True Copy for ZOS
Changed Part DKCMAIN

Device blocked though the disconnected last path is recovered


23
just before path blockade watch time
After the path blockade watch time has passed for the alternate path, the
Phenomena last path is disconnected. After that, though it is recovered just before the
watch time, the device may be blocked.
Severity (High, Medium, Low) Medium
This problem occurs With all conditions met.
1. The path blockade watch time has passed for the alternate path,
Conditions of Occurrence
2. The last path is disconnected and it is connected again just before the
watch time
Affected Products/Version DKCMAIN: 50-04-20-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Universal Volume Manager
HDS Confidential 9 of 20
Changed Part DKCMAIN

24 ICC occurs when SSM command is issued


When the host turned on the CHP, ICC occurred.
Phenomena When a SET SUBSYSTEM CACHE ON command was issued, ICC
occurred.
Severity (High, Medium, Low) Low
This problem occurs With all conditions met.
- ESCON connection
- SET SUBSYSTEM CACHE ON command
Conditions of Occurrence
- SET SUBSYSTEM CFW ON command
- SET SUBSYSTEM NVS ON command
- Shared memory access contention
Affected Products/Version DKCMAIN: 50-06-11-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category ESCON
Changed Part DKCMAIN

25 External Volume Blocked when Repeated Link Up/Link Down


When repeating the operation of plugging off and then plugging in the
Phenomena last path within 5 seconds, the external volume was blocked though the
above time was less than the path blockade watch time (10 seconds).
Severity (High, Medium, Low) Medium
This problem may occur when plugging off/plugging in the last path
Conditions of Occurrence within 5 seconds and continuing the operation for more than the path
blockade watch time (settable between 10 seconds and 3 minutes).
Affected Products/Version DKCMAIN: 50-03-99-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Universal Volume Manager
Changed Part DKCMAIN

Memory leak when HUR history operation is referred or


26
updated
Every time the UR/URZ History Operation is referred or updated in the
RAID500 Storage Navigator, a memory leak of about 4MB occurs. The
Phenomena
virtual memory size of java.exe increases cumulatively. As a result, the
SVP memory becomes insufficient, and SVP operations delay or freeze.
Severity (High, Medium, Low) Medium
This problem occurs when either of the following conditions is met.
1. Open the History Operation tab in the UR or URZ panel in the Storage
Conditions of Occurrence Navigator.
2. Refresh the screen when the History Operation tab in the UR or URZ
panel in the Storage Navigator.
Affected Products/Version SVP: 50-03-20/00 and higher
Fixed Product/Version SVP: 50-07-30/00
Category Universal Replicator/ Universal Replicator for ZOS
HDS Confidential 10 of 20
Changed Part SVP

27 After cache installation, CLPR/SLPR cannot be set


If a CLPR is defined at the time of cache installation, the [Partition
Phenomena
Definition] panel cannot be opened from the Storage Navigator or SVP.
Severity (High, Medium, Low) Medium
This phenomenon occurs when all the following conditions are met.
A: 50-03-14-00/00 or later (SVP version 50-03-16/00 or later)
Conditions of Occurrence
B: When installing a cache from the SVP, assign a cache capacity to an
undefined CLPR to define a new CLPR.
Due to an SVP micro program failure, when the cache capacity is
assigned to an undefined CLPR to define a CLPR newly at the time of
cache installation, an undefined value could be entered into the
Causes and Updates
information on the SLPR to which the CLPR belongs. Due to this
undefined value, the [Partition Definition] panel cannot be opened.
The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 50-03-16/00 and higher
Fixed Product/Version SVP: 50-07-30/00
Category SVP
Changed Part SVP

Identify panel does not appear when storage partition


28
administrator logs in
When a storage partition administrator for SLPR1 logged in, the Identity
Phenomena
panel was not displayed.
Severity (High, Medium, Low) Medium
This problem occurs With all conditions met.
1. A partition is set or changed twice or more.
Conditions of Occurrence 2. Configuration Update is not performed after the first time the partition
is set or changed.
SLPR created after the first time SLPR is created will be unavailable.
Affected Products/Version SVP: 50-03-94/00 and higher
Fixed Product/Version SVP: 50-07-30/00
Category SVP
Changed Part SVP

Parity group capacity less than 1GB displayed as 0GB in VPM


29
panel
In the Partition Definition panel in the Storage Navigator, when a parity
group registered in the CLPR is displayed, the capacity less than 1GB is
Phenomena
rounded down. (When the capacity is less than 1GB, it is displayed as "0
GB".
Severity (High, Medium, Low) Low
This problem occurs when a list of parity groups in the CLPR is
Conditions of Occurrence
displayed in the Storage Navigator "Partition Definition" panel.
Affected Products/Version SVP: 50-03-02/00 and higher
Fixed Product/Version SVP: 50-07-30/00
Category Virtual Partition Manager
Changed Part Storage Navigator

HDS Confidential 11 of 20
30 UR pair create for TC Async pair times out
If a UR pair create is performed for a TC Async pair in the multi-target
Phenomena
configuration, it times out.
Severity (High, Medium, Low) Low
This problem occurs when a UR pair create is performed for a TC Async
Conditions of Occurrence
pair.
DKCMAIN: 50-03-99-00/12, 50-04-49-00/04, 50-05-27-00/00, 50-05-
Affected Products/Version
49-00/00, 50-06-11-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Universal Replicator/ Universal Replicator for ZOS
Changed Part DKCMAIN

31 Devices not discovered properly via a switch


When multiple subsystems of different vendors that have the same serial
Phenomena number or subsystems that do not obtain serial number are connected to
the same port in USP via a switch, only one subsystem is displayed.
Severity (High, Medium, Low) Low
This problem occurs when either of the conditions is met.
A. Subsystems of different vendors that have the same serial number are
connected to the same port in USP via a switch
B. Subsystems that do not obtain serial number (SUN StorEdgeT3B,
Conditions of Occurrence SUN StorEdge6120/6320, IBM DS4000 series) are connected to the
same port in USP via a switch.
Note that in the case of B, if they have the same subsystem type (For
instance, multiple T3 are connected), they are displayed as the same
subsystem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Universal Volume Manager
Changed Part DKCMAIN

PSON flag remained due to Force Delete for Sync pair during
32
PS-ON
When a pairresync -swaps command was issued to the pair (Pair status:
Phenomena PVOL=SMPL, SVOL=SSWS) from Raid Manager, an error
[EX_CMDRJE] occurred, and SWAP failed.
Severity (High, Medium, Low) Low
This problem occurs With all conditions met.
1. TC Sync
2. LUSE pair over multiple CU
Conditions of Occurrence
3. Power cycle in MCU
4. All paths fail between MCU and RCU when PS-ON
5. Pair deleted when waiting for the failed paths to recover
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category True Copy
Changed Part DKCMAIN

HDS Confidential 12 of 20
TC Async Pair Remained in Suspending Status after Power
33
Cycle
When performing a power cycle for the True Copy Async pair in the Pair
Phenomena
status, the pair was suspended and remained in the Suspending status.
Severity (High, Medium, Low) Low
This problem occurs With all conditions met.
1. True Copy Async/ True Copy for ZOS Async pairs
Conditions of Occurrence 2. Pair or Pending Status
3. Power cycle for the MCU
4. Failure suspend occurs when PS-ON.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category True Copy Async/ True Copy for ZOS Async
Changed Part DKCMAIN

34 Invalid Execution Result for RAID Manager Command


When issuing the pairsyncwait command from the RAID Manager,
Phenomena
"BROKEN" might be displayed.
Severity (High, Medium, Low) Low
This problem occurs With all conditions met.
1. Two or more groups (CTG) of URZ pair are in the PAIR status,
Conditions of Occurrence
2. Issuing the pairsyncwait command from the RAID Manager to the
pairs whose journal group numbers in use is larger
Affected Products/Version DKCMAIN: 50-05-42-00/00/ 50-06-04-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category RAID Manager API
Changed Part DKCMAIN

35 No Battery Installation Message on Shared Memory Addition


The following phenomena may occur.
[Phenomenon 1] The battery backup time for a Planned power off or
Power failure is shorter than the product specifications.
[Phenomenon 2] The failure of Battery13 and/or 23 is not detected by
microcode.
Phenomena
[Phenomenon 3] Battery Installation Message for Battery13 and 23 is not
displayed at the time of DKC-F510I-SX/SXR/SX1GR (Shared Memory
Path Expansion Kit)
installation.

Severity (High, Medium, Low) Medium


Conditions of Occurrence [Phenomenon 1] occurs when all of the following conditions are met.
A. RAID500 (DKCMAIN 50-02-10-00/00 and later, USP/XP12000)
B. DKC-F510I-CX/CXR/CX1GR is not installed.
C. Number of sets of installed CHA/DKA packages is less than four in
total.
D. DKC-F510I-SX/SXR/SX1GR is installed.
HDS Confidential 13 of 20
E. Battery13 and 23 are not mounted.
Note: Battery 13 and 23 are installed when DKC-F510I-
CX/CXR/CX1GR is installed or more than 3 sets of CHA/DKA
packages, in total, are installed.

[Phenomenon 2] occurs when all of the following conditions are met.


A. RAID500 (DKCMAIN 50-02-10-00/00 and later, USP/XP12000)
B. DKC-F510I-CX/CXR/CX1GR is not installed.
C. Number of sets of installed CHA/DKA packages is less than four in
total.
D. DKC-F510I-SX/SXR/SX1GR is installed.
E. Battery13 and 23 are mounted.

[Phenomenon 3] occurs when all of the following conditions are met.


A. RAID500 (DKCMAIN 50-02-10-00/00 and later, USP/XP12000)
B. DKC-F510I-CX/CXR/CX1GR is not installed.
C. Number of sets of installed CHA/DKA packages is less than four in
total.
D. Installing DKC-F510I-SX/SXR/SX1GR
The microcode to order the installation of Battery13 and 23 for DKC-
Causes and Updates F510I-SX/SXR/SX1GR upgrading was not appropriate.
The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 50-02-09/00 and higher
Fixed Product/Version SVP: 50-07-30/00
Category SVP
Changed Part Battery

36 HDD Replacement Failure due to HDD Recovery ABEND


Since the HDD recovery, operation (drive copy or correction copy) in the
Phenomena
RAID1 configuration ended abnormally, the HDD replacement failed.
Severity (High, Medium, Low) Medium
This problem occurs when conditions A, B, C, and D, or A, B, C, and E
are met.
A. RAID1 configuration
Conditions of Occurrence B. HDD recovery operation (drive copy or correction copy)
C. The PDEV recovered is on left side of the L2 frame (L2x-10 or larger)
D. TC/TCZ pairs and data transfer to R-VOL does not end in 15 seconds
E. 50-05-06-00/00 or higher and BIND option is set for the parity group
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category HDD
Changed Part DKCMAIN

37 SSB=5038 when Issuing BCM Command YKEWAIT


Phenomena When issuing the YKEWAIT command via BCM or with using the BCM

HDS Confidential 14 of 20
script to URZ pairs, the response might take up to 2 seconds. SSB=5038
was reported (response exceeds 750 ms).
Severity (High, Medium, Low) Low
This problem may occur With all conditions met.
1. Universal Replicator for ZOS volumes with any emulation types other
than 3390-3
Conditions of Occurrence
2. Issuing the YKEWAIT command via BCM or with using the BCM
script to pairs in Suspend status (the more URZ pairs in Suspend status or
the larger the volume capacity, the chance of occurrence is higher.)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Universal Replicator for ZOS
Changed Part DKCMAIN

38 SVP Memory Leak Problem


Phenomenon 1:
When using the export tool or the Storage Navigator, an error message
Phenomena was displayed asking to call the support center.
Phenomenon 2:
The operation from Hi-Command failed.
Severity (High, Medium, Low) Medium
This problem may occur when the memory of SVP is full.
Phenomenon 1:
The switching operations between View and Modify on the Storage
Conditions of Occurrence Navigator exceeds 10,000 times without rebooting the SVP.
Phenomenon 2:
The SVP connected to Hi-Command has not been rebooted for more than
one month.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 50-07-30/00
Category RMI
Changed Part SVP

39 RCU Target Port WCHK1 when TC Initial Copy


When performing the initial copy for a True Copy pair, WCHK1
Phenomena
occurred at the RCU target port.
Severity (High, Medium, Low) High
Conditions of Occurrence A nonexistent LDEV is paired as the R-VOL of the True Copy pair.
Affected Products/Version DKCMAIN: 50-06-10-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category True Copy
Changed Part DKCMAIN

40 Reset Failure of Internal JOB on RCU


When the RCU received a reset for the I/O issued for creating the pair,
Phenomena
SSB=16AC, 169B, and 16A2 occurred.
Severity (High, Medium, Low) Low
The problem occurs With all conditions met:
1. Pair-creating (True Copy/ Universal Replicator) is performed
Conditions of Occurrence
2. The RCU receives a reset for the I/O issued for creating the pair
(The reset is caused by cable plugging off or I/O timeout etc.)
Affected Products/Version DKCMAIN: All
HDS Confidential 15 of 20
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category True Copy
Changed Part DKCMAIN

41 SSB=DD0A Reported Continuously


One path was blocked and caused the overloaded status. As a result, the
Phenomena
I/O was timeout and SSB=DD0A was reported continuously.
Severity (High, Medium, Low) Low
Conditions of Occurrence A reset is received due to I/O timeout.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category OPEN
Changed Part DKCMAIN

42 Invalid SI Pair Status on Storage Navigator


When displaying the SI-OPEN panel on the Storage Navigator after
having created SI pairs, the pairs were shown in the SMPL status and the
Phenomena
pair creating/deleting operations were unavailable on the Storage
Navigator though these pairs were created successfully.
Severity (High, Medium, Low) Medium
This problem occurs when creating 2254 or more SI pairs in the 1:2
Conditions of Occurrence
configuration, or 2253 or more SI pairs in the 1:3 configuration.
Affected Products/Version DKCMAIN: 50-04-06-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Shadow Image
Changed Part DKCMAIN

43 Pool Recovery Operation Failure


When performing a recovery for a blocked Pool from the Pool
Phenomena
registration panel of Storage Navigator, the operation failed.
Severity (High, Medium, Low) Low
The problem occurs With all conditions met:
Conditions of Occurrence 1. Multiple Pool volumes of COW Snapshot are defined in one Pool,
2. CU:LDEV = 00:00 is not mounted
Affected Products/Version DKCMAIN: 50-04-06-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Copy-on-Write Snapshot
Changed Part DKCMAIN

SPM Initialize Setting Available for Storage Administrator


44
without Permission
When the storage administrator without write permission clicked the
Phenomena
Initialize button on the SPM panel, the setting was enabled.
Severity (High, Medium, Low) Medium
The problem occurs when the storage administrator makes operations on
Conditions of Occurrence
the SPM panel without write permission.
Causes and Updates The micro-program has been modified so that the Initialize button will

HDS Confidential 16 of 20
not be active in this case.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 50-07-30/00
Category Server Priority Manager
Changed Part Storage Navigator

45 SVP Memory Leak due to SVP HDD Failure


When the file access performance was degraded due to SVP HDD
failures etc, a memory leak occurred in DLL for storing the option
Phenomena
monitor data so that the SVP (RISMAN.exe) memory use increased
significantly.
Severity (High, Medium, Low) Low
The problem occurs With all conditions met.
Conditions of Occurrence 1. Option monitor switch is set to ON
2. The file access performance is degraded due to SVP HDD failures etc
Affected Products/Version SVP: All
Fixed Product/Version SVP: 50-07-30/00
Category Performance Monitor
Changed Part SVP

46 CFW data problem at the time of Cache or SM replacement


When an emergency de-stage, which is performed at the time of cache or
shared memory replacement, is not completed within the specified time,
Phenomena the CFW (Cache Fast write) data problem may occur.
Note that this problem does not occur when a replacement is performed
after the cache or shared memory is blocked due to a failure.
Severity (High, Medium, Low) High
Conditions of Occurrence When <Condition 1> or <Condition 2> is met, this phenomenon may
occur.
<Condition1>
A. RAID200, RAID300, RAID400, RAID450, RAID500
B. All the conditions (a), (c), and (e) are met
< Condition2>
A. RAID500 (DKCMAIN ver.50-06-11-00/00 or higher)
B. All the conditions (a), (b), (d) and (e) are met
(a) In a mainframe environment, a job is running using CFW
(b) When the CUs set in all mainframe PCBs are grouped as follows, the
subsystem has two or more groups:
Group 0: CU# 00-3F
Group 1: CU# 40-7F
Group 2: CU# 80-BF

HDS Confidential 17 of 20
Group 3: CU# C0-FF
(c) Replacement or dummy replacement of CACHE PCB
(d) Replacement or dummy replacement of SM PCB
(e) An emergency de-stage, which is performed at the time of (c) or (d),
is not completed within 110 minutes due to a PDEV failure or overload,
and an emergency de-stage is terminated (SSB EC=3272)
When an emergency de-stage, which is performed at the time of cache or
shared memory replacement, is terminated abnormally, the CFW data on
the cache is discarded, but the CFW ID may not be incremented in some
Causes and Updates cases. As a result, the host job cannot recognize that the CFW data was
discarded, and issues an I/O to the CFW data. Since the CFW data does
not exist in the cache memory, the old data is read from the HDD. As a
result, a data problem may occur.
<Condition 1> DKCMAIN: All
Affected Products/Version
<Condition 2> DKCMAIN: 50-06-11-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category SM/CM (Mainframe)
Changed Part DKCMAIN

47 Failed to Add a V-VOL to a V-VOL Group


When adding a V-VOL to a V-VOL group with the VLL operation, an
Phenomena
error was reported and the operation failed.
Severity (High, Medium, Low) Medium
The problem occurs With all conditions met.
Conditions of Occurrence 1. Local mode 269 is set to ON
2. The volume with the VLL setting includes a V-VOL
Affected Products/Version SVP: 50-04-40/00 and higher
Fixed Product/Version SVP: 50-07-30/00
Category SVP/ Storage Navigator
Changed Part SVP

Version Down Guard in FCv2 P-VOL=TCZ S-VOL


48
Configuration
When downgrading the micro-program to a version that did not support
the FCv2 P-VOL=TCZ S-VOL configuration, the operation succeeded.
Phenomena
However, there was no guarantee of proper pair operation since the pair
status remained invalid.
Severity (High, Medium, Low) Medium
The problem occurs With all conditions met.
1. The primary volume of FCv2 and the secondary volume of TCZ share
Conditions of Occurrence the same volume
2. Downgrading the micro-program to a version (V05 and lower) that
does not support the FCv2-TCZ configuration in #1
The micro-program has been modified so that the micro-program
Causes and Updates
downgrading will not be available.
Affected Products/Version DKCMAIN: 50-06-11-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Flash Copy Version 2
Changed Part DKCMAIN

49 TC/TCZ Pair Suspend with SSB=C828


Phenomena When performing a True Copy/ True Copy for ZOS operation, the pair
HDS Confidential 18 of 20
was suspended with SSB=C828 reported.
Severity (High, Medium, Low) Medium
The problem occurs With all conditions met.
1. MCU is RAID500
Conditions of Occurrence 2. True Copy (Sync/Async)/ True Copy for ZOS (Sync/Async)
3. The RCU path is defined on the ports under the same MP
4. One of the two paths is blocked
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category True Copy (Sync/Async)/ True Copy for ZOS (Sync/Async)
Changed Part DKCMAIN

50 All Pairs Suspended when performing takeover


When performing takeover for the UR/ URZ pairs, all the pairs in the
Phenomena
JNL group were suspended.
Severity (High, Medium, Low) Medium
The problem occurs With all conditions met.
1. Universal Replicator/ Universal Replicator for ZOS pairs
2. Performing takeover
Conditions of Occurrence
3. There are multiple pairs in the JNL group
4. MCU and RCU are in the different frames, and the JNL group
numbers of both MCU and RCU are not 0
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Universal Replicator/ Universal Replicator for ZOS
Changed Part DKCMAIN

51 Data Error on the Target Volume of FCv2/CoW Snapshot


Phenomena When establishing or deleting a relation of Flash Copy Version 2 (FCv2),
or when creating or deleting a pair of Copy-on-Write Snapshot (COW
Snapshot), following phenomena may occur.
[Phenomenon 1]
The data is not copied or is copied invalidly onto the target volume of
Shadow Image (SI), FCv1, or FCv2.
[Phenomenon 2]
The data is not copied onto the source volume when performing a restore
from the target volume to the source volume of COW Snapshot.
[Phenomenon 3]
The data is not copied onto the target volume when performing a write
onto the source volume of COW Snapshot. Alternatively, the data is not
copied onto the target volume when performing a write onto the target
volume of COW Snapshot.
[Phenomenon 4]
The data is not copied to the target volume of Volume Migration.
[Phenomenon 5]
Relation establishing or pair creating fails (SSB EC=9683, 9686).
Volume Migration fails.
[Phenomenon 6]
The added Shared Memory for the differential table cannot be reduced
though there is no pair or relationship of SI, FCv1, FCv2, Volume

HDS Confidential 19 of 20
Migration, Cross-System Copy, or COW Snapshot in the subsystem.
(The check box of “MRCF/HOMRCF/…Extension” on a Shared
Memory Size Configuration screen cannot be turned off.)
Severity (High, Medium, Low) High
Please see sheet "Conditions of Occurrence" for the conditions.

Conditions of Occurrence *1: 50-03-99-00/08, 50-04-48-00/00, 50-05-21-00/00, 50-06-11-00/00


*2: 50-03-93-00/00 or higher, and lower than 50-03-99-00/08, 50-04-48-
00/00, 50-05-21-00/00, 50-06-11-00/00
When performing the pair operation, part of the table managing the
differential table is initialized (set to “0”). Therefore, instead of the
reserved differential table, the top differential table is used so that the
Causes and Updates
differential information stored in the reserved differential table is not
referenced.
The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 50-03-93-00/00 and higher
Fixed Product/Version DKCMAIN: 50-07-30-00/00
Category Flash Copy Version 2/ Copy-on-Write Snapshot
Changed Part DKCMAIN

HDS Confidential 20 of 20