Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.
Santha Kumar
5.3 Local buckling
Local buckling is an extremely important facet of cold formed steel
sections on account of the fact that the very thin elements used will invariably
buckle before yielding. Thinner the plate, the lower will be the load at which the
buckles will form.
5.3.1 Elastic buckling of thin plates
It has been shown in the chapter on “Introduction to Plate Buckling” that a
flat plate simply supported on all edges and loaded in compression (as shown in
Fig. 5.3(a)) will buckle at an elastic critical stress given by
2
Kπ2 E ⎛t⎞
pcr = ⎜ ⎟ (5.1)
(
12 1 − v 2 ) ⎝b⎠
5.3 (a) Axially compressed plate simply supported on all edges
Indian Institute of Technology Madras
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
5.3 (b) Axially compressed plate with one edge supported and the other
edge free to move
Substituting the values for π, v = 0.3 and E = 205 kN/mm2, we obtain the value
2
⎛t⎞ (5.1a)
of pcr as pcr ≈ 185 x103 x K ⎜ ⎟ with units of N/ mm2
⎝b⎠
Fig.5.4 The technique of stiffening the element
The value of K is dependent on support conditions. When all the edges
are simply supported K has a value of 4.0.
When one of the edges is free to move and the opposite edge is
supported, (as shown in Fig. 5.3b), the plate buckles at a significantly lower load,
as K reduces dramatically to 0.425. This shows that plates with free edges do not
perform well under local buckling. To counter this difficulty when using cold
formed sections, the free edges are provided with a lip so that they will be
Indian Institute of Technology Madras
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
constrained to remain straight and will not be free to move. This concept of
stiffening the elements is illustrated in Fig. 5.4.
5.3.2 Post - critical behaviour
Fig. 5.5 Local buckling effects
Let us consider the channel subjected to a uniform bending by the
application of moments at the ends. The thin plate at the top is under flexural
compression and will buckle as shown in Fig. 5.5 (a). This type of buckling is
characterised by ripples along the length of the element. The top plate is
supported along the edges and its central portion, which is far from the supports,
will deflect and shed the load to the stiffer edges. The regions near the edges are
prevented from deflecting to the same extent. The stresses are non uniform
across the section as shown in Fig.5.5 (b). It is obvious that the applied moment
Indian Institute of Technology Madras
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
is largely resisted by regions near the edges (i.e. elements which carry increased
stresses) while the regions near the centre are only lightly stressed and so are
less effective in resisting the applied moment.
From a theoretical stand point, flat plates would buckle instantaneously at
the elastic critical load. Under incremental loading, plate elements which are not
perfectly flat will begin to deform out of plane from the beginning rather than
instantaneously at the onset of buckling and fail at a lower load. This means that
a non-uniform state of stress exists throughout the loading regime. The variation
of mean stress with lateral deflection for flat plates and plates with initial
imperfection, under loading are shown in Fig. 5.6.
This tendency is predominant in plates having b/t (breadth/thickness)
ratios of 30-60. For plates having a b/t value in excess of 60, the in-plane tensile
stresses or the “membrane stresses” (generated by the stretching of the plates)
resist further buckling and cause an increase in the load-carrying capacity of
wide plates.
Fig. 5.6 Mean stress Vs lateral deflection relation
Indian Institute of Technology Madras
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
5.3.3 Effective width concept
The effects of local buckling can be evaluated by using the concept of
effective width. Lightly stressed regions at centre are ignored, as these are least
effective in resisting the applied stresses. Regions near the supports are far more
effective and are taken to be fully effective. The section behaviour is modeled on
the basis of the effective width (beff) sketched in Fig. 5.5(c).
The effective width, (beff) multiplied by the edge stress (σ) is the same as
the mean stress across the section multiplied by the total width (b) of the
compression member.
The effective width of an element under compression is dependent on
the magnitude of the applied stress fc, the width/thickness ratio of the element
and the edge support conditions.
5.3.4 Code provisions on “Local buckling of compressed plates”
The effective width concept is usually modified to take into account the
effects of yielding and imperfection. For example, BS5950: Part 5 provides a
semi-empirical formula for basic effective width, beff, to conform to extensive
experimental data.
When fc > 0.123 pcr, then
−0.2
⎡ ⎧⎪ ⎡ f ⎤ 0.5 ⎫⎪ ⎤
4
beff ⎢ ⎥
= ⎢1 + 14 ⎨ ⎢ c
⎥ − 0.35⎬ ⎥ (5.2a)
b
⎢⎣ ⎪⎩ ⎣ pcr ⎦ ⎪⎭ ⎥
⎦
When fc < 0.123 pcr, then beff = b (5.2b)
Indian Institute of Technology Madras
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
Where
fc = compressive stress on the effective element, N/ mm2
pcr = local buckling stress given by
pcr = 185,000 K ( t / b)2 N/ mm2
K = load buckling coefficient which depends on the element type, section
geometry etc.
t = thickness of the element, in mm
b = width of the element, in mm
The relationship given by eqn. 5.2(a) is plotted in Fig.5.7
Fig.5.7 Ratio of effective width to flat width (fy = 280 N/mm2) of compression
plate with simple edge supports
It is emphasised that in employing eqn. (5.2a), the value of K (to compute
pcr) could be 4.0 for a stiffened element or 0.425 for an unstiffened element.
BS5950, part 5 provides for a modification for an unstiffened element
under uniform compression (Refer clause 4.5.1). The code also provides
modifications for elements under combined bending and axial load (ref. Clause
Indian Institute of Technology Madras
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
4.5.2). Typical formula given in BS 5950, Part 5 for computing K values for a
channel element is given below for illustration. (see BS 5950, Part 5 for a
complete list of buckling coefficients).
1. Lipped channel.
The buckling coefficient K1 for the member having a width of B1 in a lipped
channel of the type shown above is given by
1.8h
K1 = 7 − − 1.43h 3 (5.3a)
0.15 + h
Where h = B2 / B1
For the member having the width of B2 in the above sketch.
2
⎛t ⎞
K2 = K2h ⎜ 1 ⎟
2
(5.3b)
⎝ t2 ⎠
Where t1 and t2 are the thicknesses of element width B1 and B2
respectively. (Note: normally t1 and t2 will be equal). The computed values of K2
should not be less than 4.0 or 0.425 as the case may be.
Indian Institute of Technology Madras
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
2. Plain channel (without lips)
The buckling coefficient K1 for the element of width B1 is given by
2 2 + 4.8h
K1 = + (5.4)
(1 + 15h )
3 0.5 (
1 + 15h 3 )
K2 is computed from eqn.. 5.3(b) given above.
5.3.4.1 Maximum width to thickness ratios
IS: 801 and BS 5950, Part 5 limit the maximum ratios of (b/t) for
compression elements as follows:
• Stiffened elements with one longitudinal edge connected to a flange
or web element and the other stiffened by a simple lip 60
• Stiffened elements with both longitudinal edges connected to other stiffened
elements 500
• Unstiffened compression elements 60
However the code also warns against the elements developing very large
deformations, when b/t values exceed half the values tabulated above.
Indian Institute of Technology Madras
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
5.3.5 Treatment of elements with stiffeners
5.3.5.1 Edge stiffeners
As stated previously, elements having b/t ? 60 and provided with simple lip
having one fifth of the element width may be regarded as a stiffened element. If
b/t > 60, then the width required for the lip may become too large and the lip itself
may have stability problems. Special types of lips (called "compound" lips) are
designed in such cases and these are outside the scope of this chapter.
5.3.5.2 Intermediate stiffeners
A wide and ineffective element may be transformed into a highly effective
element by providing suitable intermediate stiffeners (having a minimum moment
of inertia (Imin) about an axis through the element mid surface). The required
minimum moment of inertia of the stiffener about the axis 0-0 in Fig. 5.8 is given
by:
⎛ w ⎞ ⎛ fy ⎞
2
I min = 0.2t . ⎜ ⎟ . ⎜
4
⎟ (5.5)
⎝ t ⎠ ⎝ 280 ⎠
Where w = larger flat width of the sub element (see Fig. 5.8) between
stiffeners (in mm)
t = thickness of the element (mm)
fy = yield stress (N/mm2)
Fig.5.8 Intermediate stiffener
Indian Institute of Technology Madras
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
If the sub-element width/thickness ratio (w/t) does not exceed 60, the total
effective area of the element may be obtained by adding effective areas of the
sub-elements to the full areas of stiffeners.
When (w/t) is larger than 60, the effectiveness of the intermediately
stiffened elements is somewhat reduced due to shear lag effects. (Refer to
BS5950, Part 5, clauses 4.7.2 and 4.7.3) If an element has a number of stiffeners
spaced closely (b/t ? 30), and then generally all the stiffeners and sub elements
can be considered to be effective. To avoid introducing complexities at this stage,
shear lag effects are not discussed here.
5.3.6 Effective section properties
In the analysis of member behaviour, the effective section properties are
determined by using the effective widths of individual elements. As an example,
let us consider the compression member ABCDEF shown in Fig.5.9. The
effective portions of the member are shown darkened (i.e. 1-B, B-2, 3-C, C-4, 5-
D, D-6, 7-E, and E-8). The parts A-1, 2-3, 4-5, 6-7 and 8-F are regarded as being
ineffective in resisting compression. As a general rule, the portions located close
to the supported edges are effective (see Fig.5.5c) . Note that in the case of
compression members, all elements are subject to reductions in width.
Fig. 5.9 Effective widths of compression elements
Indian Institute of Technology Madras
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
In the case of flexural members, in most cases, only the compression
elements are considered to have effective widths. Some typical effective sections
of beams are illustrated in Fig.5.10.
Fig. 5.10 Effective flexural sections
As in the previous example, fully effective sections in compression
elements are darkened in Fig.5.10. The portions 1-2 and 3-4 in Fig. 5.10(a) and
the portion 1-2 in Fig. 5.10 (b) are regarded as ineffective in resisting
compression. Elements in tension are, of course, not subject to any reduction of
width, as the full width will resist tension
5.3.7 Proportioning of stiffeners
The performance of unstiffened elements could be substantially improved
by introducing stiffeners (such as a lip). Similarly very wide elements can be
divided into two or more narrower sub elements by introducing intermediate
stiffeners formed during the rolling process; the sum of the "effective widths" of
individual sub elements will enhance the efficiency of the section.
According to BS 5950, Part 5 an unstiffened element (when provided with
a lip) can be regarded as a stiffened element, when the lip or the edge stiffener
has a moment of inertia about an axis through the plate middle surface equal to
or greater than
Indian Institute of Technology Madras
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
b3 t
I min = (5.6)
375
Where t and b are the thickness and breadth of the full width of the
element to be stiffened.
For elements having a full width b less than or equal to 60 t, a simple lip of
one fifth of the element width (i.e. b/5) can be used safely. For lips with b > 60 t, it
would be appropriate to design a lip to ensure that the lip itself does not develop
instability.
A maximum b/t ratio of 90 is regarded as the upper limit for load bearing
edge stiffeners.
The Indian standard IS: 801-1975 prescribes a minimum moment of inertia
(w t )
2
for the lip given by I min = 1.83 t 4 − 281200 but not less than 9.2 t4 .
Fy
Where Imin = minimum allowable moment of inertia of stiffener about its
own centroidal axis parallel to the stiffened element in cm4
w / t = flat width - thickness ratio of the stiffened element.
Fy = Yield stress in kgf/cm2
For a simple lip bent at right angles to the stiffened element, the required
(w t )
2
overall depth dmin is given by d min = 2.8t 6 − 281200 but not less than
Fy
4.8 t
Indian Institute of Technology Madras
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
Note that both the above equations given by the Indian standard are
dependent on the units employed.
5.3.7.1 Intermediate stiffeners.
Intermediate stiffeners are used to split a wide element into a series of
narrower and therefore more effective elements. The minimum moment of inertia
about an axis through the element middle surface required for this purpose
(according to BS 5950, Part 5) is given in equation (5.5) above.
The effective widths of each sub element may be determined according to
equation 5.2 (a) and eqn..5.2(b) by replacing the sub element width in place of
the element width b.
When w / t < 60, then the total effective area of the element is obtained as
the sum of the effective areas of each sub element to the full areas of stiffeners.
When the sub elements having a larger w / t values are employed (w/ t >
60), the performance of intermittently stiffened elements will be less efficient. To
model this reduced performance , the sub element effective width must be
reduced to ber given by,
ber beff ⎛w ⎞
= − 0.1⎜ − 60 ⎟ (5.7)
t t ⎝ t ⎠
The effective stiffener areas are also reduced when w / t > 90 by
employing the equation:
ber
A eff = Ast . (5.8)
w
Indian Institute of Technology Madras
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
Where Ast = the full stiffener area and
Aeff = effective stiffener area.
For w / t values between 60 and 90, the effective stiffener area varies between
Ast and Aeff as given below:
⎡ b 1 ⎛ b ⎞ w⎤
A eff = Ast ⎢3 − 2 er − ⎜1 − er ⎟ ⎥ (5.9)
⎣ w 30 ⎝ w ⎠ t⎦
It must be noted that when small increases in the areas of intermediate
stiffeners are provided, it is possible to obtain large increases in effectiveness
and therefore it is advantageous to use a few intermediate stiffeners, so long as
the complete element width does not exceed 500 t.
When stiffeners are closely spaced, i.e. w < 30 t, the stiffeners and sub
elements may be considered to be fully effective. However there is a tendency
for the complete element (along with the stiffeners) to buckle locally. In these
circumstances, the complete element is replaced for purposes of analysis by an
element of width b and having fictitious thickness ts given by
1
⎛ 12 Is ⎞ 3
ts = ⎜ ⎟ (5.10)
⎝ b ⎠
Where Is = Moment of inertia of the complete element including
stiffeneres, about its own neutral axis.
IS: 801- 1975 also suggests some simple rules for the design of
intermediate stiffeners.
When the flanges of a flexural member is unusually wide, the width of
flange projecting beyond the web is limited to
Indian Institute of Technology Madras
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
126500td 100 cf
wf = x 4 (5.10a)
f uv d
Where t = flange thickness
d = depth of beam
cf = the amount of curling
fav = average stress in kgf/cm2 as specified in IS: 801 – 1975.
The amount of curling should be decided by the designer but will not generally
exceed 5 % of the depth of the section.
Equivalent thickness of intermediate stiffener is given by
12 Is
ts = 3 (5.10b)
ws
Indian Institute of Technology Madras