This document provides specifications for various CJPS generator models ranging from 27KVA to 1375KVA. For each model it lists the continuous, prime and standby power ratings, engine details including model, cylinders and cooling type, physical dimensions for both open and silent versions, fuel consumption at 100% load, and weight. The generators can use either diesel or natural gas fueled engines from 4 cylinders up to 16 cylinders with turbocharging and aftercooling on many of the larger models.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
258 views2 pages

Brosur Cummins 2018

This document provides specifications for various CJPS generator models ranging from 27KVA to 1375KVA. For each model it lists the continuous, prime and standby power ratings, engine details including model, cylinders and cooling type, physical dimensions for both open and silent versions, fuel consumption at 100% load, and weight. The generators can use either diesel or natural gas fueled engines from 4 cylinders up to 16 cylinders with turbocharging and aftercooling on many of the larger models.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

L

Power (KVA) Engine Spesification Dimension (mm) Fuel


Weight Open
Genset Model Open Type Silent Type Consumption
Continuous Prime Standby Engine Model Cylinder Governor Aspiration Cooling System Type (Kg)
(L x W x H) (L x W x H) 100% Load
CJPS C-27 WP 27 30 22 24 4B3.9-G2 4L ECR Natural 1750 x 970 x 1530 2000 x 1000 x 1400 9.4 980
CJPS C-40 WP 40 44 32 35 4BT3.9-G2 4L ECR Turbocharged 1780 x 970 x 1530 2200 x 1000 x 1400 9.4 980
CJPS C-50 WP 50 55 40 44 4BTA3.9-G2 4L ECR T + After-cooled 1850 x 970 x 1530 2600 x 1200 x 1500 13.1 1070
CJPS C-85 WP 85 94 68 75 6BT5.9-G2 6L ECR Turbocharged 1850 x 970 x 1530 2800 x 1200 x 1500 22 1070
CJPS C-100 WP 100 110 80 88 6BT5.9-G2 6L ECR Turbocharged 2150 x 1030 x 1580 2800 x 1200 x 1500 22 1200
CJPS C-120 WP 120 132 96 106 6BTA5.9-G2 6L ECR T + After-cooled 2150 x 1030 x 1580 3600 x 1200 x 2300 27 1400
CJPS C-135 WP 135 149 108 119 6BTAA5.9-G2 6L ECR T + After-cooled 2320 x 1030 x 1580 3600 x 1200 x 2300 30 1400
CJPS C-160 WP 160 176 128 141 6CTA8.3-G2 6L ECR T + After-cooled 2500 x 1000 x 1500 3600 x 1200 x 2300 40 1500
CJPS C-180 WP 180 198 144 158 6CTA8.3-G2 6L ECR T + After-cooled 2500 x 1000 x 1500 3600 x 1400 x 2400 42 1600
CJPS C-200 WP 200 220 160 176 6CTAA8.3-G2 6L ECR T + After-cooled 2500 x 1000 x 1550 3600 x 1400 x 2400 45 1700
CJPS C-225 WP 225 248 180 198 6LTAA8.9-G2 6L ECR T + After-cooled 2500 x 1100 x 1800 4000 x 1400 x 2300 53 2300
CJPS C-250 WP 250 275 200 220 NT855-GA 6L ECR Turbocharged 2650 x 1100 x 1800 4000 x 1400 x 2300 55 3100
CJPS C-300 WP 300 330 240 264 NTA855-G1A 6L ECR T + After-cooled 3050 x 1100 x 1800 4200 x 1600 x 2600 61.3 3300
CJPS C-313 WP 313 344 250 275 MTAA11-G3 6L ECR T + After-cooled 2650 x 1100 x 1800 4200 x 1600 x 2600 71.6 3100
CJPS C-350 WP 350 385 280 308 NTA855-G2A 6L ECR T + After-cooled 3070 x 1260 x 1750 4200 x 1600 x 2600 72 3350
CJPS C-400 WP 400 440 320 352 NTAA855-G7 6L ECR T + After-cooled 3220 x 1260 x 1800 4400 x 1600 x 2300 86 4800
CJPS C-425 WP 425 468 340 374 NTAA855-G7A 6L ECR T + After-cooled 3220 x 1260 x 1800 4400 x 1800 x 2600 98 4850
CJPS C-450 WP 450 495 360 396 KTA19-G3 6L ECR T + After-cooled 3400 x 1450 x 2100 4400 x 1800 x 2600 97 4900
CJPS C-500 WP 500 550 400 440 KTA19-G4 6L ECR T + After-cooled 3400 x 1450 x 2100 4400 x 1800 x 2600 107 4900
CJPS C-525 WP 525 578 420 462 QSZ13-G3 6L ECR T + After-cooled 3600 x 1355 x 1900 4400 x 1800 x 2600 101 3970
CJPS C-550 WP 550 605 440 484 KTAA19-G5 6L ECR T + After-cooled 3400 x 1450 x 2100 4900 x 1800 x 2600 112 4900
CJPS C-575 WP 575 633 460 506 KTAA19-G6 6L ECR T + After-cooled 3600 x 1680 x 2200 4900 x 1800 x 2600 118 4950
CJPS C-625 WP 625 688 500 550 KTAA19-G6A 6L ECR T + After-cooled 3600 x 1680 x 2200 4900 x 1800 x 2600 127.8 4950
CJPS C-750 WP 750 825 600 660 KTA38-G2 12V ECR T + After-cooled 4250 x 1850 x 2200 6100 x 2250 x 2850 167 7850
CJPS C-800 WP 800 880 640 704 KTA38-G2B 12V ECR T + After-cooled 4250 x 1850 x 2200 6100 x 2250 x 2850 191 7850
CJPS C-925 WP 925 1018 740 814 KTA38-G2A 12V ECR T + After-cooled 4250 x 1850 x 2200 6100 x 2250 x 2850 191 8000
CJPS C-1000 WP 1000 1100 800 880 KTA38-G5 12V ECR T + After-cooled 4250 x 1850 x 2200 6100 x 2250 x 3000 209 9800
CJPS C-1125 WP 1125 1238 900 990 KTA38-G9 12V ECR T + After-cooled 4450 x 1750 x 2350 6100 x 2500 x 3100 206 9800
CJPS C-1250 WP 1250 1375 1000 1100 KTA50-G3 12V ECR T + After-cooled 5000 x 2000 x 2300 6100 x 2500 x 3100 274 10100
CJPS C-1375 WP 1375 1513 1100 1210 KTA50-G8 16V ECR T + After-cooled 5800 x 2000 x 2600 6500 x 2450 x 3300 289 9800