SR-700 Series: ULTRA-COMPACT Code Reader Instruction Manual
SR-700 Series: ULTRA-COMPACT Code Reader Instruction Manual
• Do not use a voltage other than 5VDC with the SR-700 Series. Doing so
may lead to damage on the unit.
ULTRA-COMPACT Code Reader • When using the dedicated communication units (N-R2/R4/UB/L1, or DV-90
Series), use a power supply within the appropriate range for each unit.
SR-700 Series
• Be sure to turn the power off to devices attached to the SR-700 Series
when you plug or unplug the cables. Failure to do so may cause damage
to the SR-700 Series.
Instruction manual • Do not disassemble or modify the SR-700 Series. Doing so may lead to
damage on the unit.
• Keep the cables away from high-tension cables or power sources.
Otherwise, noise could cause malfunctions or accidents.
Read this instruction manual before using the product in order to achieve • The SR-700 Series is a precision instrument.
Do not apply shock to the instrument or drop
maximum performance. it. Be especially careful when transporting or
Keep this instruction manual in a safe place after reading it so that it can be installing the unit.
used at any time.
Symbols
The following symbols alert you to important messages. Be sure to read
these messages carefully. NOTICE
• Do not hold the SR eries by its cable. The
It indicates a hazardous situation which, if not avoided, will result in death or units may become damaged if they strike
DANGER
serious injury. each other.
Important It indicates cautions and limitations that must be followed during operation.
• Do not allow water, oil, dust, or other foreign substances to stick to the
Reference It indicates tips for better understanding or useful information. scanner. This may cause read errors. Use a soft, dry cloth to wipe any
substances from the scanner. (Do not use a cloth dipped in alcohol or
other cleaning substance.)
indicates the reference pages in this manual or the reference pages in separate manuals.
1 E SR-700-IM
FDA (CDRH) Regulations Part Names and Functions
This product complies with the following FDA (CDRH) regulations.
• FDA(CDRH) Part 1040.10, Class 1 Laser Product
The laser classification for FDA(CDRH) is implemented based on IEC60825-
(8) IN LED
1 in accordance with the requirements of Laser Notice No.50.
FCC Regulations
This product complies with the following FCC EMI regulations.
• FCC Part 15 Subpart B, Class A Digital Device
Radio Waves Act in South Korea (7) Multiple LED (11) TEST switch
Class A Equipment indicator
(9) OK/NG/ERR LED (10) TUNE switch
This is a class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate
measures.
Note: This caution is effective for the Korean Radio Act only. (1) Scanner
A 급 기기 ( 업무용 방송통신기자재 )
이 기기는 업무용 (A 급 ) 전자파적합기기로서 판매자 또는 사용자는 이 점을 (2) Cable
주의하시기 바라며 , 가정외의 지역에서 사용하는 것을 목적으로 합 니다 .
Washer x 2
(3) Connector
(round connector)
Name Function
(1) Scanner Reads 2D codes and barcodes.
(2) Cable Cable length is 1.8 m.
Connects to the power supply and communication unit
Connector
(3) (N-R2/UB/R4/L1). The connector can be used for serial
(Round connector)
communications with external devices.
Connects to a PC to change settings with AutoID Network
(4) USB Connector Navigator. The connector is type A. Cable length is 130 mm
from the section where the cable splits.
When the USB connector is not in use, place the cap on the
(5) USB connector cap connector to prevent the entry of dust and contact with
Mounting bracket x 1 Instruction Manual surrounding metal objects.
When the USB connector is not in use, place the USB cable
(6) Cable holder
in the cable holder so that it does not move around.
96M13107
Precautions on Proper Use
Do not use a voltage other than 5VDC with the SR Series. Doing so may
lead to damage on the unit.
When using the dedicated communication units (NX-50CL, N-R2/R4/UB/
ULTRA-COMPACT Fixed Mount Code Reader L1, or DV-90 Series), use a power supply within the appropriate range for
each unit.
SR-700 Series Be sure to turn the power off to devices attached to the SR Series when
you plug or unplug the cables. Failure to do so may cause damage to the
SR Series.
Instruction manual Do not disassemble or modify the SR Series. Doing so may lead to
damage on the unit.
Keep the cables away from high-tension cables or power sources.
Read this instruction manual before using the product in order to achieve Otherwise, noise could cause malfunctions or accidents.
Symbols
The following symbols alert you to important messages. Be sure to read
these messages carefully. NOTICE
Do not hold the SR eries by its cable. The
(7) Multiple LED indicator upon successful decoding, reading stability and operation
It indicates a hazardous situation which, if not avoided, will result in death or
DANGER units may become damaged if they strike
serious injury.
each other.
It indicates a hazardous situation which, if not avoided, could result in death
WARNING
or serious injury.
It indicates a hazardous situation which, if not avoided, could result in minor
CAUTION
or moderate injury.
It indicates a situation which, if not avoided, could result in product damage
NOTICE
as well as property damage.
Important It indicates cautions and limitations that must be followed during operation.
mode.
Point It indicates additional information on proper operation.
Reference It indicates tips for better understanding or useful information. Do not allow water, oil, dust, or other foreign substances to stick to the
scanner. This may cause read errors. Use a soft, dry cloth to wipe any
substances from the scanner. (Do not use a cloth dipped in alcohol or
indicates the reference pages in this manual or the reference pages in separate manuals. other cleaning substance.)
(8) IN LED
the work or operation.
If the SR-700 Series malfunctions, take adequate safety precautions to
CAUTION
prevent various types of damage. Applicable standards EMI : EN61326-1, Class A
Do not use the SR-700 Series in a manner not specified herein. It may EMS : EN61326-1
result in fire, electric shock or malfunction.
Remarks:
It should be noted that functions and performances will not be guaranteed
These specifications do not give any guarantee that the end-product with
E SR-700-IM 2
Connection and Wiring Method Input terminal 1 and Input terminal 2 wiring
These are non-voltage inputs. Connect relay contacts or NPN open collector
Connection to the communication unit outputs.
Connect the connector to the communication • The TIMING and PRESET inputs are non-voltage inputs.
unit (N-R2/UB/R4/L1).
Refer to the communication unit instruction
manual for more details.
4.7kΩ
220Ω
Internal circuit
10kΩ IN
6,10 With or
without
12 contacts
GND
DC5V
Connector pin alignment • TIMING (Input terminal 1) is input to initiate the 2D code and barcode
reading.
1 2
• PRESET (Input terminal 2) is input to preset (register) the 2D code and
RP17-13PA-12PC plug (male)
3 4 5 6
barcode data on the SR-700 Series.
Made by Hirose Electric Co., Ltd.
7 8 9 10
Output terminal 1, Output terminal 2, Output terminal 3
11 12
and Output terminal 4 wiring
These are NPN open collector outputs.
Signal
Pin no. Wire color Signal name Description
direction
Output terminal 1
1 Transparent OUT1 (Default value: Output
Internal circuit
OK output) 4.7kΩ OUT
1, 2, Load
Output terminal 2 5, 9
2 Gray OUT2 (Default value: Output 47kΩ 33V
NG/ERROR output) 12
GND +
3 Purple TxD RS-232C send Output
4 Blue CTS RS-232C send OK Input
Output terminal 4
5 Lt. blue OUT4 (Default value: Output * Rated load: 24VDC (30mA) or less
BUSY output)
Input terminal 2 • OK (Output terminal 1) is output for a successful reading when a check
6 Yellow green IN2 (Default value: Input against preset data is successful.
PRESET input)
• NG/ERROR output (Output terminal 2) is output for an unsuccessful
7 Brown RxD RS-232C receive Input
reading when a check against preset data fails.
8 Pink RTS RS-232C receive OK Output
• ERROR (Output terminal 3) is output for an unsuccessful reading.
Output terminal 3
9 Orange OUT3 (Default value: Output
• BUSY (Output terminal 4) is output when preset data registration has been
ERROR output) completed and internal processing is taking place.
Input terminal 1 When BUSY is output, TIMING (Input terminal 1) cannot be input.
10 Yellow IN1 (Default value: Input
TIMING input) RS-232C wiring
11 Red 5V 5 V Power –
Use the following wiring when connecting to a PC or a PLC.
12 Black GND (SG) Power GND/Signal GND –
* The shielded wire is connected to a signal ground. SR-700 Series PC, PLC
It is possible to change the functions of the input terminals and output TxD 3 2 RxD(RD)
terminals. Refer to the user's manual for making these changes.
CTS 4 7 RTS(RS)
Connecting the power RxD 7 3 TxD(SD)
RTS 8 8 CTS(CS)
GND 12 5 GND(SG)
5 VDC
GND 12 Round 6 DSR(DR)
connector
12-pin + D-sub 9-pin
(female) (female)
#4-40 screw
• Do not use a reverse connection for the power supply. Doing so may
damage the unit.
NOTICE
• Use a stable power supply that is 5 VDC +5%, -10%.
Using a power supply that exceeds this range may damage the unit.
3 E SR-700-IM
Installing the SR-700 Series Mounting the SR-700 Series
15°
Mounting
bracket
Reading distance
Point Do not position the scanner to face directly at 2D codes or barcodes. Doing
so may cause instability in reading due to mirror reflection.
2 Secure the mounting bracket to the device.
Secure the mounting bracket to the device using the installation screws,
purchased separately, with the included insulating spacers and washers.
The installation screws should be at least 3.7 mm (thickness of the
bracket, washer, etc.) + 3 mm long.
20° or more
15° or more
Washer
Insulating
spacer
Installation
screw (M4)
Adjusting the installation position and distance
1 Press the TUNE switch on the SR-700 Series. The laser pointer will
emit a laser beam.
Adjust the installation position and distance so that the laser pointer
intersection point and the center of the barcode line up.
Refer to the user's manual for tuning and confirming reading stability.
• The reading distance and angle differ depending on conditions such as
the size and the print quality of the 2D code or the barcode. Carry out
reading tests using the 2D code or barcode to be used and make
adjustments.
E SR-700-IM 4
Attaching directly to the device Mounting bracket
Secure the SR-700 Series with screws (M3). * An insulating sheet is affixed to the bottom surface of the mounting
bracket. Do not remove the sheet.
Point The installation screws, purchased separately, should not be any longer than Screw hole size 2-(R2.65)
the length of the plate thickness + 4 mm. R1.5 R18 7 C1
40°
2-M4
40°
18.5
27.5
Installation screws (M3)
φ5.3
18
5.3
32
3.5 24.3
1.5 0.7 0.7 2-R1.5
3.5
8-(R1.65)
4-3.3
33
60.8
5°
1.
°±
90
• Use insulating material when installing the SR-700 Series to prevent
NOTICE excessive noise from the device.
• Reading errors may occur if the insulating material is not attached. 6
0.7
6
Dimensions
18.5
(36.5)
33
40
φ5
Minimum bend R10
3.8
9.3 11
32
Thickness 13
Cable length 130
5 E SR-700-IM
Specifications WARRANTIES AND DISCLAIMERS
(1) KEYENCE warrants the Products to be free of defects in materials and
Model SR-700HA SR-700 SR-710 workmanship for a period of one (1) year from the date of shipment. If any
High models or samples were shown to Buyer, such models or samples were used
Type Short-range Mid-range
resolution merely to illustrate the general type and quality of the Products and not to
Light source Visible semiconductor laser (660 nm) represent that the Products would necessarily conform to said models or
Output 60 μW samples. Any Products found to be defective must be shipped to KEYENCE
Laser pointer Pulse width with all shipping costs paid by Buyer or offered to KEYENCE for inspection and
200 μs
examination. Upon examination by KEYENCE, KEYENCE, at its sole option,
Class 1
Laser class will refund the purchase price of, or repair or replace at no charge any Products
(IEC60825-1, FDA CDRH Part 1040.10)
found to be defective. This warranty does not apply to any defects resulting
Light Light source High intensity red LED
from any action of Buyer, including but not limited to improper installation,
QR, MicroQR, DataMatrix,
improper interfacing, improper repair, unauthorized modification, misapplication
2D Code GS1 DataMatrix, PDF417, Micro PDF417,
and mishandling, such as exposure to excessive current, heat, coldness,
GS1 Composite (CC-A, CC-B, CC-C)
moisture, vibration or outdoors air. Components which wear are not warranted.
Code 39, ITF,
(2) KEYENCE is pleased to offer suggestions on the use of its various Products.
2of5 (Industrial 2of5),
Supported COOP 2of5, NW-7 (Codabar), They are only suggestions, and it is Buyer's responsibility to ascertain the
code Code 128, GS1-128, fitness of the Products for Buyer’s intended use. KEYENCE will not be
Barcode *1 GS1 DataBar, Code 93, responsible for any damages that may result from the use of the Products.
JAN/EAN/UPC, (3) The Products and any samples ("Products/Samples") supplied to Buyer are not
Trioptic Code 39, to be used internally in humans, for human transportation, as safety devices or
CODE39 FullASCII, fail-safe systems, unless their written specifications state otherwise. Should any
Pharmacode
Products/Samples be used in such a manner or misused in any way,
Reading Focal distance 38 mm 60 mm 100 mm KEYENCE assumes no responsibility, and additionally Buyer will indemnify
Minimum 2D Code 0.082 mm 0.127 mm 0.19 mm KEYENCE and hold KEYENCE harmless from any liability or damage
resolution Barcode - 0.127 mm 0.127 mm whatsoever arising out of any misuse of the Products/Samples.
22 to 50 mm 40 to 80 mm 45 to 165 mm (4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
2D Code (Cell size= (Cell size= (Cell size= PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL
Reading 0.25 mm) 0.5 mm)
0.25 mm) EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING,
distance
30 to 100 mm 45 to 195 mm WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY,
(typical
(Narrow bar (Narrow bar FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF
examples) Barcode -
width width
PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED.
= 0.33 mm) = 0.5 mm)
IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE
Reading view range 26 mm x 42 mm x 70 mm x LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT,
(focal distance) 17 mm 27 mm 45 mm
INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES
Control input 2 non-voltage inputs (IN1, IN2) (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM
4 NPN open collector outputs (OUT1 to OUT4) LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION,
30 mA max. (24 V or less) LOSS OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF
Control output
ON: Residual voltage 0.8 V or less,
SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS,
OFF: leakage current 0.1 mA or less
SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF
Communicati
RS-232C standards OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE
on method
PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES
Transmission
9600, 19200, 38400, 57600, 115200 bps WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES
speed
OR ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the
Input/output Synchronizati
Asynchronous foregoing warranty disclaimers or damage limitations may not apply.
on method
RS-232C Supported
No-protocol, MC Protocol, SYSWAY, KVSTUDIO
protocol BUYER'S TRANSFER OBLIGATIONS:
Data bit If the Products/Samples purchased by Buyer are to be resold or delivered to a
7/8 bits
length third party, Buyer must provide such third party with a copy of this document, all
Stop bit specifications, manuals, catalogs, leaflets and written information provided to
1/2 bits
length Buyer pertaining to the Products/Samples.
Parity check None/Even/Odd E 1101-3
USB Full-speed USB 2.0 interface
Enclosure rating IP65
Ambient temperature 0 to +45°C
Storage temperature -10 to +50°C
Relative humidity 35 to 95% RH (No condensation)
Environment
resistance Sunlight: 10,000lx, incandescent lamp 6,000lx,
Ambient luminance
fluorescent lamp: 2,000lx
Operating environment Location without dust or corrosive gas
10 to 55 Hz: double amplitude 1.5 mm in the X, Y
Vibration
and Z directions. 3 hours respectively.
Power supply voltage 5 VDC +5%, -10%
Rating
Current consumption 630 mA or less
Weight Approx. 160 g (including the cable)
*1 Barcodes fitted into the visual field range in size can be read.