Home Inspection Checklist
Address:     A-05-07, Apartment Taman Putra Impian, Taman Putra Impian, Kajang Selangor
    Date:        15/02/2019
Bathrooms                                            Bathroom Master                                           Bathroom 1                                      Bathroom 2
                                       Code                       OK                           Code                 Summary                     Code           Summary
  Baseboards
  Cabinets, shelves, & drawers
  Ceiling
  Counter
                                         TM2         Door opening near to toilet seat
  Doors                                                                                          T1.2        Door opening near to toilet seat
                                         TM3               Got paint at door
  Floors                                                                                       TF21-23            Tiles got hollow sound        Yellow label     Tiles got hollow sound
  Stock Cork
  Lights
  Vent pipe                               TM              Pipe need to be clean                  T1.1             Pipe need to be clean            T2.1          Pipe need to be clean
  Outlets and switches
  Sink
  Toilet
  Towel hook
  Water tap
  Tub and shower
                                                                                               T1.10-18         Tiles got hollow sound          Yellow label   Wall tiles got hollow sound
                                        Yellow
  Walls                                                   Tiles got hollow sound               T1.19,20      Whole area- tiles hollow sound         T2.2       Need touch up tiles around
                                         label
                                                                                                 T1.3        Need grouting tiles around pipe                               pipe
  Window                                                                                                                                           T2.4        Window cannot close tightly
 Fixtures secure? Condition of tiles and calking? Leaks or water pressure issues? Mold? Drawers and cabinets working?
Notes:         Please re-check tiles at all area. This may be caused by improper installation method. Either the installer just “spot bonding” or the mixture of adhesive not follow the
               standards.
  House Defects Investigator                                                                                                                                                      H.D.I Ventures
                                                                                   Hall and
Balcony                        Code                       Summary                  Front Door                 Code                           Summary
                                                                                   Area
  Fence                           B1          Rusty railing, need touch up paint     Front Door               FD1-6                          Tiles got hollow sound
                                                                                                             HCP24                           Uneven paint at ceiling
  Ceiling                                                                            Ceiling
                                                                                                            HCC20,21                         Crack at ceiling beam
  Floors                          B2               Tiles got hollow sound            Ceiling Fan                 X                   Fan hook too close with ceiling beam
  Lights                                                                             Doors               HDC 7-11,14-19                    Crack at door frame area
  Outlets and switches                                                               Floors                    H1-6                          Tiles got hollow sound
  Trim                                                                               Lights
                                                                                      Outlets &                HX                        Uneven skim at switches area
  Walls
                                                                                    switches                   HX1                        Got paint , need to be clean
  Windows                                                                            Cabinet                 TC,TC2                      No cabinet cover and shelves
                                                                                                             HDC12                               Wall got crack
 Wall damage? Sloping ceiling? Weak floors?                                          Walls                  HDS13,23                             Uneven skim
                                                                                                             HDP22                               Uneven paint
Notes:                                                                               Windows
                                                                                    Wall damage? Sloping ceiling? Weak floors?
                                                                                   Notes:          Have to hack at least 1 or 2 inches width all along at crack line and
                                                                                                   Cement back . Don’t just paint or use stopping to cover the crack up.
  House Defects Investigator                                                                                                                                           H.D.I Ventures
Bedrooms                                         Master Bedroom                                                           Bedroom 1
                        Code                         Summary                                                    Code        Summary
   Outside
                                                                                                                B1CC           Ceiling got crack
   Ceiling
                                                                                                                B1CS          Uneven skim ceiling
   Closet               MBC1                             Got paint at closet door
   Doors             MBDC 6-10                          Crack at door frame area                          B1DC 14,15,23     Crack at door frame area
   Floors              MB1-5                              Tiles got hollow sound                                B1.1-13      Tiles got hollow sound
   Lights
   Switches             MBX                           Uneven skim at switches area
   Trim
                    MBDC 11,12                                Wall got crack                               B1DS 16,18            Uneven skim
   Walls
                     MBDS 13                                  Uneven skim                                 B1DC 17,19,21          Wall got crack
   Windows
Bedrooms                                            Bedroom 2                                                             Bedroom 3
                        Code                         Summary                                                    Code        Summary
   Outside
   Ceiling
   Closet
   Doors             B2DC 22,23                         Crack at door frame area
   Floors              B2.1-22                            Tiles got hollow sound
   Lights
   Switches              B2X                                   Uneven skim
   Trim
                      B2DC 24                                 Wall got crack
   Walls
                       B2DS                                   Uneven skim
   Windows              B2.25                                  Dirty window
Check ceilings for sloping and/or water damage. Are floors weak in places? Damaged windows or window screens?
Notes:
  House Defects Investigator                                                                                                                           H.D.I Ventures
Kitchen                          Code                     Summary
  Baseboards
  Cabinets and drawers            KC1                        Misaligned cabinet door      Utilities             Code   Summary
  Ceiling                                                                                   Air conditioning
  Stop Cock Valve                                                                           Circuit breakers
  Water Tap                                                                                 Drainage
  Floors                         KF1-5                       Tiles got hollow sound         Fire Extinguisher
  Garbage Disposal                                                                          Hot water heater
                                                                                            Main electrical
  Water trap                      KF6                          Drain pipe too long
                                                                                          panel
  Lights                                                                                    Water pressure
  Outlets and switches
                                                                                          Notes:
  Door
  Refrigerator
  Sink
  Walls                         KW6-11                Whole area-tiles got hollow sound
  Windows
Leaking sink or appliances? Cabinet & drawer condition?
Notes:
House Defects Investigator                                                                                                       H.D.I Ventures