5.
1 Daily Operations - Startup and Shutdown
• Startup
– Bump start both motors to check for correct rotation
– Start the back drive motor
– Wait 10 seconds and start the main drive motor
– Give the centrifuge 10 minutes to achieve operating speed
– Open the suction valve on mud tank
– Start pump with a low feed rate
– Bring the feed rate up slowly to desired processing rate
• Shutdown
– Bring the feed rate down slowly
– Shut off the feed pump
– Flush until clean liquid is coming from liquid discharge of centrifuge
– Close the suction valve on mud tank
– Run centrifuge for 10 minutes min
– Shut off the main drive motor, back drive still turns
– Back drive motor will shut off automatically, motor is on a time delay
switch
5 4
Daily Operations Daily Operations