Motor Purge Control System MPC for Zone 1 and 2
Motor Purge Controller MPC
Features Description
Automatically functioning Ex px purge system The motor purge control system consisting of an
for electric motors MPC Motor Purge Controller and an MPV Motor
Purge Valve (outlet valve) is a unit which allows
Fail-safe control – SIL 2
the safe operation of electric motors in hazardous
Purging/operation status display environments.
The explosion protection is ensured by means of a
pressurised enclosure with leakage loss compensa-
tion.
The Motor Purge Control System monitors, controls
and regulates the supply of purge gas to the Ex p
motor.
Any faults that arise within the system or during the
supply of purge gas will be reliably reported and
deactivated by a safe disconnection of the Ex p motor.
Dimensions
280 360
470
03-0330-0751-05/2014-BCS-356504/1
Motor Purge Control System MPC for Zone 1 and 2
Explosion protection Technical data
Ex protection type Zone 1 Construction
ATEX II 2(1)G Ex de [ia Ga px] IIC T4 Gb inside the protective housing
Certification Varnish
DMT 99 ATEX E 082 RAL 7035
IECEx Ex de [ia Ga px] IIC T4 Gb Enclosure material
sheet steel (stainless steel on request)
Certification
IECEx BVS 13.0039 Protection class
IP 55 (internal components IP 65)
Ex protection type Zone 2
ATEX II 3G Ex nA nC [ic pz] IIC T4 Gc Connection terminals
2.5 mm²
Further approvals
see BARTEC Internet: www.bartec-group.com Pressure measuring range
0 to 25 mbar
Ambient temperature
-20 °C to +40 °C Purge time
0 to 99 minutes (settable)
Directives
2004/108/EC
94/9/EC Supply of purge gas
Inlet
Electrical data R 1" internal thread MPC S2
R 1 ½" internal thread MPC S3
Supply voltage
AC 230 V (AC 115 V) ± 10 % Outlet
R 1" internal thread
Power consumption
P = approx. 20 W/AC 230 V Signal lines
3 x pipe connection 10 mm
Signal contacts
Enabling contact K2/(Ex p operation) Flow rate
K2/3, 5 A at cos φ = 1, non-floating 0 to 180 m³ MPC S2
0 to 450 m³ MPC S3
Signal contact K4 (purging operation)
floating, 500 mA at AC 250 V/DC 80 V Leakage compensation
0.05 l/s to 11.5 l/s
Signal contact K5
(switching level freely assignable)
floating, 500 mA at AC 250 V/DC 80 V
Selection chart MPC for Zone 1
Description Rated voltage Code no. Variante Code no.
AC 230 V 1 MPC S2 2
System MPC
AC 115 V 2 MPC S3 3
Complete order no. 07-3711-6210/ M O
Please enter code number. Technical data subject to change without notice.
Selection chart MPC for Zone 2
03-0330-0751-05/2014-BCS-356504/2
Description Rated voltage Code no. Variante Code no.
AC 230 V 1 MPC S2 2
System MPC
AC 115 V 2 MPC S3 3
Complete order no. A7-3711-6110/ M O
Please enter code number. Technical data subject to change without notice.