0% found this document useful (0 votes)
61 views8 pages

Off Delay Timer

1. This document provides product details for a modular timing relay called the RE17RCMU. It has an off-delay timing range of 1 second to 100 hours and is designed to work with 24-240V AC power. 2. The relay has a single changeover output contact rated for 8A. Additional details include screw terminal connections, DIN rail mounting, LED indicators, and CE/UL certification. 3. The timing relay provides off-delay functionality, meaning the output contact closes when power is applied but remains closed for the set time delay after power is removed.

Uploaded by

ABDUL GHAFOOR
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
61 views8 pages

Off Delay Timer

1. This document provides product details for a modular timing relay called the RE17RCMU. It has an off-delay timing range of 1 second to 100 hours and is designed to work with 24-240V AC power. 2. The relay has a single changeover output contact rated for 8A. Additional details include screw terminal connections, DIN rail mounting, LED indicators, and CE/UL certification. 3. The timing relay provides off-delay functionality, meaning the output contact closes when power is applied but remains closed for the set time delay after power is removed.

Uploaded by

ABDUL GHAFOOR
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Product datasheet RE17RCMU

Characteristics off-delay timing relay - 1 s..100 h - 24..240 V AC -


1 OC

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range of product Zelio Time
Product or component type Modular timing relay
Discrete output type Relay
Width 17.5 mm
Device short name RE17R
Time delay type C
Time delay range 6...60 s
1...10 h
1...10 min
6...60 min
0.1...1 s
1...10 s
10...100 h
Nominal output current 8 A

Complementary
Contacts type and composition 1 C/O
Contacts material Cadmium free
Height 90 mm
Depth 72 mm
Control type Selector switch front panel
[Us] rated supply voltage 24...240 V AC 50/60 Hz
24 V DC
Voltage range 0.85...1.1 Us
Supply frequency 50...60 Hz +/- 5 %
Release of input voltage 10 V
Connections - terminals Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end

Oct 22, 2019


1
Tightening torque 0.6…1 N.m conforming to IEC 60947-1
Housing material Self-extinguishing
Repeat accuracy +/- 0.5 % conforming to IEC 61812-1
Temperature drift +/- 0.05 %/°C
Voltage drift +/- 0.2 %/V
Setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Control signal pulse width 100 ms with load in parallel typical
30 ms typical
Insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1
Reset time 120 ms on de-energisation typical
On-load factor 100 %
Power consumption in VA 0…32 VA at 240 V AC
Maximum power consumption in W 0.6 W at 24 V DC
Minimum switching current 10 mA at 5 V DC
Maximum switching current 8 A AC/DC
Maximum switching voltage 250 V AC
Breaking capacity 2000 VA
Operating frequency 10 Hz
Electrical durability 100000 cycles (8 A at 250 V AC maximum) for resistive load
Mechanical durability 10000000 cycles
Dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
[Uimp] rated impulse withstand voltage 5 kV during 1.2/50 µs
Power on delay 100 ms
Marking CE
Creepage distance 4 kV/3 conforming to IEC 60664-1
Safety reliability data B10d = 270000
MTTFd = 296.8 years
Mounting position Any position in relation to normal vertical mounting plane
Mounting support 35 mm DIN rail conforming to EN/IEC 60715
Local signalling LED indicator for on steady: relay energised, no timing in progress
LED indicator for flashing: timing in progress 80 % ON and 20 % OFF
LED indicator for pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) 5 %
ON and 95 % OFF
Net weight 0.07 kg
Time delay type C
Functionality Off-delay timing
Compatibility code RE17

Environment
Immunity to microbreaks 20 ms
Standards EN 61000-6-4
EN 61000-6-2
EN 61000-6-3
2004/108/EC
2006/95/EC
IEC 61812-1
EN 61000-6-1
Product certifications CULus
GL
CSA
Ambient air temperature for storage -30…60 °C
Ambient air temperature for operation -20…60 °C
IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
Vibration resistance 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27

2
Relative humidity 93 % without condensation conforming to IEC 60068-2-30
Electromagnetic compatibility Electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2
Electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC
61000-4-3
Electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to
IEC 61000-4-4
Electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5
Conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11
Voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11
Conducted and radiated emissions: , class B, conforming to EN 55022

Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation REACh Declaration
EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free Yes
RoHS exemption information Yes
China RoHS Regulation China RoHS declaration
Environmental Disclosure Product Environmental Profile
Circularity Profile End of Life Information

3
Product datasheet RE17RCMU
Dimensions Drawings

Width 17.5 mm

4
Product datasheet RE17RCMU
Connections and Schema

Internal Wiring Diagram

5
Product datasheet RE17RCMU
Connections and Schema

Wiring Diagram

6
Product datasheet RE17RCMU
Technical Description

Function C : Off-Delay Relay with Control Signal

Description
After power-up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end of the timing
period, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.

Function: 1 Output

Function: 2 Outputs

2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)

7
Product datasheet RE17RCMU
Technical Description

Legend

Relay de-energised
Relay energised
Output open
Output closed
C Control contact
G Gate
R Relay or solid state output
R1/R2 2 timed outputs
R2 inst. The second output is instantaneous if the right position is selected
T Timing period
Ta - Adjustable On-delay
Tr - Adjustable Off-delay
U Supply