CH - CA and MH - MA Enclosures: Size "104.27" Standard Version

This document provides specifications for various CH-CA and MH-MA enclosures including: 1) Surface mounting housings that come with either 2 levers or 4 pegs and ensure an IP66 protection rating when mated and locked. 2) The insert center distance is 104 x 27 mm. 3) Options include housings with levers, pegs, and covers in aluminum or plastic. High construction versions and sizes for 1, 2, or 4 modules are also listed.

Uploaded by

Lazar Rares
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
133 views13 pages

CH - CA and MH - MA Enclosures: Size "104.27" Standard Version

This document provides specifications for various CH-CA and MH-MA enclosures including: 1) Surface mounting housings that come with either 2 levers or 4 pegs and ensure an IP66 protection rating when mated and locked. 2) The insert center distance is 104 x 27 mm. 3) Options include housings with levers, pegs, and covers in aluminum or plastic. High construction versions and sizes for 1, 2, or 4 modules are also listed.

Uploaded by

Lazar Rares
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

CH - CA and MH - MA enclosures size “104.

27” standard version


bulkhead mounting housings bulkhead mounting housings
inserts: page with 2 levers or 4 pegs with single lever
CD .......................... 64 poles + m 45
CT, CTS (10A) ........ 64 poles + m 51
CDD ...................... 108 poles + m 58
CQE ........................ 46 poles + m 77
CN .......................... 24 poles + m 83
CCE ........................ 24 poles + m 92
CNE, CSE................ 24 poles + m 93
CSS ........................ 24 poles + m 101
CTE, CTSE (16A) .... 24 poles + m 109
CMSE ........ 10+2 (aux) poles + m 118
CMCE ........ 10+2 (aux) poles + m 118
CX .......................... 4/8 poles + m 133
MIXO ........................ 6 modules 137÷151

insert centre distance:


104 x 27 mm

description part No. part No.

with one or two levers CHI 24 CHI 24 L

with pegs 1)
CHI 24 C

with pegs and aluminium cover 1)


CHI 24 CS

with pegs and plastic cover 1)


CHI 24 CP

with lever and cover CHI 24 LS

1)
May be combined with hoods: dimensions in mm dimensions in mm
- CHO/CAO 24 X and CHV/CAV 24 X
size 104.27

- MHO/MAO 24 X and MHV/MAV 24 X


CHI CHI L
N.B.: the enclosures ensure IP66 protection (or IP65
179.5 59 76.5
cover versions) rating when mated and locked with the
closing levers.
The cover (CS, CP) only ensures mechanical
protection, but does not ensure IP65 protection rating.
29 29

panel cut-out for bulkhead mounting housings in mm


142.5 45.5 6 142.5 45.5 6

ø 4.5

CHI C CHI LS
97

112 130
29

142.5 45.5 6
29

142.5 45.5 6

32
CHI CS/CP
35
74

29

142.5 45.5 6

E Type
4/4X/12
(excluding enclosures with plastic
cover)

dimensions indicated are not binding


and may be changed without notice

212
CH - CA and MH - MA enclosures size “104.27” standard version
surface mounting housings surface mounting housings
inserts: page with 2 levers or 4 pegs with single lever
CD .......................... 64 poles + m 45
CDD ...................... 108 poles + m 58
CQE ........................ 46 poles + m 77
CN .......................... 24 poles + m 83
CCE ........................ 24 poles + m 92
CNE, CSE................ 24 poles + m 93
CSS ........................ 24 poles + m 101
CMSE ........ 10+2 (aux) poles + m 118
CMCE ........ 10+2 (aux) poles + m 118
CX .......................... 4/8 poles + m 133
MIXO ........................ 6 modules 137÷151

insert centre distance:


104 x 27 mm

description part No. entry part No. entry part No. entry part No. entry
Pg M Pg M

with levers CHP 24 21 MHP 24.25 25 CHP 24 L 21 MHP 24 L25 25


with levers CHP 24.2 21 x 2 MHP 24.225 25 x 2 CHP 24 L2 21 x 2 MHP 24 L225 25 x 2
with levers, high construction CAP 24.21 21 MAP 24.32 32 CAP 24 L 21 MAP 24 L32 32
with levers, high construction CAP 24.221 21 x 2 MAP 24.232 32 x 2 CAP 24 L2 21 x 2 MAP 24 L232 32 x 2
with levers, high construction CAP 24.29 29 MAP 24.40 40 CAP 24 L29 29 MAP 24 L40 40
with levers, high construction CAP 24.229 29 x 2 MAP 24.240 40 x 2 CAP 24 L229 29 x 2 MAP 24 L240 40 x 2

with pegs and aluminium cover 1) CHP 24 CS 21 MHP 24 CS25 25


with pegs and aluminium cover 1) CHP 24 CS2 21 x 2 MHP 24 CS225 25 x 2
with pegs and aluminium cover, high construction 1)
CAP 24 CS 21 MAP 24 CS32 32
with pegs and aluminium cover, high construction 1)
CAP 24 CS2 21 x 2 MAP 24 CS232 32 x 2

size 104.27
with pegs and aluminium cover, high construction 1)
CAP 24 CS29 29 MAP 24 CS40 40
with pegs and aluminium cover, high construction 1)
CAP 24 CS229 29 x 2 MAP 24 CS240 40 x 2

with pegs and plastic cover 1) CHP 24 CP 21 MHP 24 CP25 25


with pegs and plastic cover 1) CHP 24 CP2 21 x 2 MHP 24 CP225 25 x 2
with pegs and plastic cover, high construction 1)
CAP 24 CP 21 MAP 24 CP32 32
with pegs and plastic cover, high construction 1)
CAP 24 CP2 21 x 2 MAP 24 CP232 32 x 2
with pegs and plastic cover, high construction 1)
CAP 24 CP29 29 MAP 24 CP40 40
with pegs and plastic cover, high construction 1)
CAP 24 CP229 29 x 2 MAP 24 CP240 40 x 2

with lever and cover CHP 24 LS 21 MHP 24 LS25 25


with lever and cover CHP 24 LS2 21 x 2 MHP 24 LS225 25 x 2
with lever and cover, high construction CAP 24 LS 21 MAP 24 LS32 32
with lever and cover, high construction CAP 24 LS2 21 x 2 MAP 24 LS232 32 x 2
with lever and cover, high construction CAP 24 LS29 29 MAP 24 LS40 40
with lever and cover, high construction CAP 24 LS229 29 x 2 MAP 24 LS240 40 x 2

1)
May be combined with hoods: dimensions in mm dimensions in mm
- CHO/CAO 24 X and CHV/CAV 24 X CHP - CAP and MHP - MAP CHP L - CAP L and MHP L - MAP L
- MHO/MAO 24 X and MHV/MAV 24 X
179.5 59 74
N.B.: the enclosures ensure IP66 protection (or IP65
cover versions) rating when mated and locked with the
closing levers.
The cover (CS, CP) only ensures mechanical
protection, but does not ensure IP65 protection rating. Ø 5.5 A Ø 5.5 A
Pg/M Pg/M Pg/M Pg/M

132 45 4 132 45 4
144 57 144 57

CHP CS/CP - CAP CS/CP and MHP CS/CP - MAP CS/CP CHP LS - CAP LS and MHP LS - MAP LS
74 97

Ø 5.5 A Ø 5.5 A
Pg/M Pg/M Pg/M Pg/M

E Type
4/4X/12
(excluding enclosures with plastic
132

144
45

57
4 132

144
45

57
4

cover) type A type A


CHP / MHP 63 CHP L / MHP L 63
CAP / MAP 81 CAP L / MAP L 81
CHP CS / MHP CS 63 CHP LS / MHP LS 63
CAP CS / MAP CS 81 CAP LS / MAP LS 81
dimensions indicated are not binding CHP CP / MHP CP 63
and may be changed without notice CAP CP / MAP CP 81

213
CH - CA and MH - MA enclosures size “104.27” standard version
hoods hoods
inserts: page with 4 pegs with 2 pegs
CD .......................... 64 poles + m 45
CDD ...................... 108 poles + m 58
CQE ........................ 46 poles + m 77
CN .......................... 24 poles + m 83
CCE ........................ 24 poles + m 92
CNE, CSE................ 24 poles + m 93
CSS ........................ 24 poles + m 101
CMSE ........ 10+2 (aux) poles + m 118
CMCE ........ 10+2 (aux) poles + m 118
CX .......................... 4/8 poles + m 133
MIXO ........................ 6 modules 137÷151

insert centre distance:


104 x 27 mm

description part No. entry part No. entry part No. entry part No. entry
Pg M Pg M

with pegs, side entry CHO 24 21 MHO 24.25 25 CHO 24 L 21 MHO 24 L25 25
with pegs, side entry MHO 24.32 32 MHO 24 L32 32
with pegs, side entry, high construction CAO 24.21 21 MAO 24.32 32 CAO 24 L21 21 MAO 24 L32 32
with pegs, side entry, high construction CAO 24.29 29 MAO 24.40 40 CAO 24 L29 29 MAO 24 L40 40

with pegs, top entry CHV 24 21 MHV 24.25 ** 25 CHV 24 L 21 MHV 24 L25 25
with pegs, top entry MHV 24.32 32 MHV 24 L32 32
with pegs, top entry CHV 24.29 29 MHV 24.40 40 CHV 24 L29 29 MHV 24 L40 40
with pegs, top entry, high construction CAV 24.21 21 MAV 24.32 32 CAV 24 L21 21 MAV 24 L32 32
with pegs, top entry, high construction CAV 24.29 29 MAV 24.40 40 CAV 24 L29 29 MAV 24 L40 40

with pegs, frontal entry, high construction CAF 24.21 21 MAF 24.25 25
size 104.27

with pegs, frontal entry, high construction CAF 24.29 29 MAF 24.32 32

with pegs, frontal entry, high construction, without adaptor * CFF 24.21 21 MFF 24.25 25
with pegs, frontal entry, high construction, without adaptor * CFF 24.29 29 MFF 24.32 32

* enclosure without adaptor, threaded on the body, to dimensions in mm dimensions in mm


be used only with a complete cable clamp.

** can only be used with a complete cable clamp (to CHO (CAO) and MHO (MAO) CHO L (CAO L) and MHO L (MAO L)
be purchased separately)

Pg/M Pg/M
63 (76) 63 (76)

120 43 120 43

CHV (CAV) and MHV (MAV) CHV L (CAV L) and MHV L (MAV L)

Pg/M Pg/M

68 * (91) 68 * (91)

120 43 120 43

* 69.5 for Pg 29 - M 40 versions * 69.5 for Pg 29 - M 40 versions

E Type
4/4X/12
CAF/CFF and MAF/MFF

Pg/M
76

120 43

dimensions indicated are not binding


and may be changed without notice

214
CH - CA and MH - MA enclosures size “104.27” standard version
hoods hoods
inserts: page with 2 levers with single lever
CD .......................... 64 poles + m 45
CDD ...................... 108 poles + m 58
CQE ........................ 46 poles + m 77
CN .......................... 24 poles + m 83
CCE ........................ 24 poles + m 92
CNE, CSE................ 24 poles + m 93
CSS ........................ 24 poles + m 101
CMSE ........ 10+2 (aux) poles + m 118
CMCE ........ 10+2 (aux) poles + m 118
CX .......................... 4/8 poles + m 133
MIXO ........................ 6 modules 137÷151

insert centre distance:


104 x 27 mm

description part No. entry part No. entry part No. entry part No. entry
Pg M Pg M

with levers and gasket, top entry CHV 24 G 21 MHV 24 G32 32 CHV 24 LG 21 MHV 24 LG32 32
with levers and gasket, top entry, high construction CAV 24 G 21 MAV 24 G25 25 CAV 24 LG21 21 MAV 24 LG25 25
with levers and gasket, top entry, high construction CAV 24 G29 29 MAV 24 G32 32 CAV 24 LG29 29 MAV 24 LG32 32
with levers and gasket, top entry, high constr., without adaptor * CFV 24 G 21 MFV 24 G25 25 CFV 24 LG21 21 MFV 24 LG25 25
with levers and gasket, top entry, high constr., without adaptor * CFV 24 G29 29 MFV 24 G32 32 CFV 24 LG29 29 MFV 24 LG32 32

* enclosure without adaptor, threaded on the body, to dimensions in mm dimensions in mm


be used only with a complete cable clamp.
CHV G (CAV G) and [CFV G], CHV LG (CAV LG) and [CFV LG],
MHV G (MAV G) and [MFV G] MHV LG (MAV LG) and [MFV LG]

size 104.27
59 136 74
120
43 120 43

[81.5] 73.5 [81.5] 73.5


(97 max) (97 max)

179.5 Pg/M Pg/M

E Type
4/4X/12

dimensions indicated are not binding


and may be changed without notice

215
CH - CA and MH - MA enclosures size “104.27” standard version
inserts: page hoods covers
with two levers
CD .......................... 64 poles + m 45
CDD ...................... 108 poles + m 58
CQE ........................ 46 poles + m 77
CN .......................... 24 poles + m 83
CCE ........................ 24 poles + m 92
CNE, CSE................ 24 poles + m 93
CSS ........................ 24 poles + m 101
CMSE ........ 10+2 (aux) poles + m 118
CMCE ........ 10+2 (aux) poles + m 118
CX .......................... 4/8 poles + m 133
MIXO ........................ 6 modules 137÷151

insert centre distance: 104 x 27 mm

The covers for C, G and LG, versions cannot be used


together with coding pins. If this application is required,
please contact ILME SpA.

description part No. entry part No. entry part No.


Pg M

with levers, side entry 1) CHO 24 X 21 MHO 24 X25 25


with levers, side entry 1) MHO 24 X32 32
with levers, side entry, high construction 1)
CAO 24 X 21 MAO 24 X32 32
with levers, side entry, high construction 1)
CAO 24 X29 29 MAO 24 X40 40

with levers, top entry 1) CHV 24 X 21 MHV 24 X25 25


with levers, top entry 1) MHV 24 X32 32
with levers, top entry, high construction 1)
CAV 24 X 21 MAV 24 X32 32
with levers, top entry, high construction 1)
CAV 24 X29 29 MAV 24 X40 40
with 4 pegs (for enclosures with 2 levers with gasket) CHC 24
with 4 pegs and gasket (for enclosures with 2 levers) 2) CHC 24 C
size 104.27

with 2 pegs (for enclosures with 1 lever with gasket) CHC 24 L


with 2 levers (for hoods with 4 pegs) CHC 24 G
with 1 lever (for hoods with 2 pegs) CHC 24 LG

1)
May be combined with housings: dimensions in mm dimensions in mm
- CHI/CHP/CAP 24 CS/CP/C
- MHP/MAP 24 CS/CP CHO X (CAO X) and MHO X (MAO X) CHC

Pg/M 12
2)
May be combined with hoods:
- CHO/CAO 24 X and CHV/CAV 24 X 63 (76) 120 43
- MHO/MAO 24 X and MHV/MAV 24 X

120 43
CHC C

179.5 59
17.5

120 43

CHV X (CAV X) and MHV X (MAV X)


Pg
CHC L
M

12

68 (91) 120 43

CHC G
120 43
120 43
179.5 59

17.5

E Type
4/4X/12
CHC LG
179.5 59

120 43

17.5

dimensions indicated are not binding 136 74


and may be changed without notice

216
CM - CMA and MM - MMA enclosures size “104.27” insulated 830V version
bulkhead mounting housings bulkhead mounting housings
inserts: page with 2 levers or 4 pegs with single lever
CME .............. 10 + 2 (aux) poles + m 119
CME, CMCE 16 + 2 (aux) poles + m 124

insert centre distance:


104 x 27 mm

description part No. part No.

with one or two levers CMI 16 CMI 16 L

with pegs and aluminium cover 1)


CMI 16 CS

with pegs and plastic cover 1)


CMI 16 CP

with lever and cover CMI 16 LS

1)
May be combined with hoods: dimensions in mm dimensions in mm
- CMO/CMAO 16 X and CMV/CMAV 16 X
- MMO/MMAO 16 X and MMV/MMAV 16 X
CMI CMI L
N.B.: the enclosures ensure IP66 protection (or IP65

size 104.27
cover versions) rating when mated and locked with the 179.5 59 76.5
closing levers.
The cover (CS, CP) only ensures mechanical
protection, but does not ensure IP65 protection rating.
29 29
panel cut-out for bulkhead mounting housings in mm
142.5 45.5 6 142.5 45.5 6

ø 4.5

CMI CS/CP CMI LS


74 97

112 130

29 29

142.5 45.5 6 142.5 45.5 6

32
35

E Type
4/4X/12
(excluding enclosures with plastic
cover)

dimensions indicated are not binding


and may be changed without notice

217
CM - CMA and MM - MMA enclosures size “104.27” insulated 830V version
surface mounting housings surface mounting housings
inserts: page with 2 levers or 4 pegs with single lever
CME .............. 10 + 2 (aux) poles + m 119
CME, CMCE 16 + 2 (aux) poles + m 124

insert centre distance:


104 x 27 mm

description part No. entry part No. entry part No. entry part No. entry
Pg M Pg M

with levers CMP 16 21 MMP 16.25 25 CMP 16 L 21 MMP 16 L25 25


with levers CMP 16.2 21 x 2 MMP 16.225 25 x 2 CMP 16 L2 21 x 2 MMP 16 L225 25 x 2
with levers, high construction CMAP 16.21 21 MMAP 16.32 32 CMAP 16 L 21 MMAP 16 L32 32
with levers, high construction CMAP 16.221 21 x 2 MMAP 16.232 32 x 2 CMAP 16 L2 21 x 2 MMAP 16 L232 32 x 2
with levers, high construction CMAP 16.29 29 MMAP 16.40 40 CMAP 16 L29 29 MMAP 16 L40 40
with levers, high construction CMAP 16.229 29 x 2 MMAP 16.240 40 x 2 CMAP 16 L229 29 x 2 MMAP 16 L240 40 x 2

with pegs and aluminium cover 1) CMP 16 CS 21 MMP 16 CS25 25


with pegs and aluminium cover 1) CMP 16 CS2 21 x 2 MMP 16 CS225 25 x 2
with pegs and aluminium cover, high construction 1)
CMAP 16 CS 21 MMAP 16 CS32 32
with pegs and aluminium cover, high construction 1)
CMAP 16 CS2 21 x 2 MMAP 16CS232 32 x 2
size 104.27

with pegs and aluminium cover, high construction 1)


CMAP 16 CS29 29 MMAP 16 CS40 40
with pegs and aluminium cover, high construction 1)
CMAP 16CS229 29 x 2 MMAP 16CS240 40 x 2

with pegs and plastic cover 1) CMP 16 CP 21 MMP 16 CP25 25


with pegs and plastic cover 1) CMP 16 CP2 21 x 2 MMP 16 CP225 25 x 2
with pegs and plastic cover, high construction 1)
CMAP 16 CP 21 MMAP 16 CP32 32
with pegs and plastic cover, high construction 1)
CMAP 16 CP2 21 x 2 MMAP 16CP232 32 x 2
with pegs and plastic cover, high construction 1)
CMAP 16 CP29 29 MMAP 16 CP40 40
with pegs and plastic cover, high construction 1)
CMAP 16CP229 29 x 2 MMAP 16CP240 40 x 2

with lever and cover CMP 16 LS 21 MMP 16 LS25 25


with lever and cover CMP 16 LS2 21 x 2 MMP 16 LS225 25 x 2
with lever and cover, high construction CMAP 16 LS 21 MMAP 16 LS32 32
with lever and cover, high construction CMAP 16 LS2 21 x 2 MMAP 16LS232 32 x 2
with lever and cover, high construction CMAP 16 LS29 29 MMAP 16 LS40 40
with lever and cover, high construction CMAP 16LS229 29 x 2 MMAP 16LS240 40 x 2

1)
May be combined with hoods: dimensions in mm dimensions in mm
- CMO/CMAO 16 X and CMV/CMAV 16 X CMP - CMAP and MMP - MMAP CMP L - CMAP L and MMP L - MMAP L
- MMO/MMAO 16 X and MMV/MMAV 16 X
179.5 59 74
N.B.: the enclosures ensure IP66 protection (or IP65
cover versions) rating when mated and locked with the
closing levers.
The cover (CS, CP) only ensures mechanical
protection, but does not ensure IP65 protection rating. Ø 5.5 A A
Pg/M Pg/M Pg/M Ø 5.5
Pg/M

132 45 4 132 45 4
144 57 144 57

CMP CS/CP - CMAP CS/CP and MMP CS/CP - MMAP CS/CP CMP LS - CMAP LS and MMP LS - MMAP LS
74 97

Ø 5.5 A A

E
Pg/M Pg/M Pg/M Pg/M Ø 5.5
Type
4/4X/12 132 45 4 132 45 4

144 57 144 57
(excluding enclosures with plastic
cover) type A type A
CMP / MMP 63 CMP L / MMP L 63
CMAP / MMAP 81 CMAP L / MMAP L 81
CMP CS / MMP CS 63 CMP LS / MMP LS 63
CMAP CS / MMAP CS 81 CMAP LS / MMAP LS 81
dimensions indicated are not binding CMP CP / MMP CP 63
and may be changed without notice CMAP CP / MMAP CP 81

218
CM - CMA and MM - MMA enclosures size “104.27” insulated 830V version
hoods hoods
inserts: page with 4 pegs with 2 pegs
CME .............. 10 + 2 (aux) poles + m 119
CME, CMCE 16 + 2 (aux) poles + m 124

insert centre distance:


104 x 27 mm

description part No. entry part No. entry part No. entry part No. entry
Pg M Pg M

with pegs, side entry CMO 16 21 MMO 16.25 25 CMO 16 L 21 MMO 16 L25 25
with pegs, side entry MMO 16.32 32 MMO 16 L32 32
with pegs, side entry, high construction CMAO 16.21 21 MMAO 16.32 32 CMAO 16 L21 21 MMAO 16 L32 32
with pegs, side entry, high construction CMAO 16.29 29 MMAO 16.40 40 CMAO 16 L29 29 MMAO 16 L40 40
with pegs, top entry CMV 16 21 MMV 16.25 ** 25 CMV 16 L 21 MMV 16 L25 25
with pegs, top entry MMV 16.32 32 MMV 16 L32 32
with pegs, top entry CMV 16.29 29 MMV 16.40 40 CMV 16 L29 29 MMV 16 L40 40
with pegs, top entry, high construction CMAV 16.21 21 MMAV 16.32 32 CMAV 16 L21 21 MMAV 16 L32 32
with pegs, top entry, high construction CMAV 16.29 29 MMAV 16.40 40 CMAV 16 L29 29 MMAV 16 L40 40
with pegs, frontal entry, high construction CMAF 16.21 21 MMAF 16.25 25

size 104.27
with pegs, frontal entry, high construction CMAF 16.29 29 MMAF 16.32 32
with pegs, frontal entry, high constr., without adaptor * CMFF 16.21 21 MMFF 16.25 25
with pegs, frontal entry, high constr., without adaptor * CMFF 16.29 29 MMFF 16.32 32

* enclosure without adaptor, threaded on the body, to dimensions in mm dimensions in mm


be used only with a complete cable clamp.

** can only be used with a complete cable clamp (to


be purchased separately) CMO (CMAO) and MMO (MMAO) CMO L (CMAO L) and MMO L (MMAO L)

Pg/M Pg/M
63 [76] 63 [76]

120 43 120 43

CMV (CMAV) and MMV (MMAV) CMV L (CMAV L) and MMV L (MMAV L)

Pg/M Pg/M

68 * (91) 68 * (91)

120 43 120 43

* 69.5 for Pg 29 - M 40 versions * 69.5 for Pg 29 - M 40 versions

E Type
4/4X/12
CMAF/CMFF and MMAF/MMFF

Pg/M
76

120 43

dimensions indicated are not binding


and may be changed without notice

219
CM - CMA and MM - MMA enclosures size “104.27” insulated 830V version
hoods hoods
inserts: page with 2 levers with single lever

CME .............. 10 + 2 (aux) poles + m 119


CME, CMCE 16 + 2 (aux) poles + m 124

insert centre distance:


104 x 27 mm

description part No. entry part No. entry part No. entry part No. entry
Pg M Pg M

with levers and gasket, top entry CMV 16 G 21 MMV 16 G32 32 CMV 16 LG 21 MMV 16 LG32 32
with levers and gasket, top entry, high construction CMAV 16 G 21 MMAV 16 G25 25 CMAV 16 LG21 21 MMAV 16 LG25 25
with levers and gasket, top entry, high construction CMAV 16 G29 29 MMAV 16 G32 32 CMAV 16 LG29 29 MMAV 16 LG32 32
with levers and gasket, top entry, high constr., without adaptor * CMFV 16 G 21 MMFV 16 G25 25 CMFV 16 LG21 21 MMFV 16 LG25 25
with levers and gasket, top entry, high constr., without adaptor * CMFV 16 G29 29 MMFV 16 G32 32 CMFV 16 LG29 29 MMFV 16 LG32 32

* enclosure without adaptor, threaded on the body, to dimensions in mm dimensions in mm


be used only with a complete cable clamp.
CMV G (CMAV G) and [CMFV G], CMV LG (CMAV LG) and [CMFV LG],
MMV G (MMAV G) and [MMFV G] MMV LG (MMAV LG) and [MMFV LG]
size 104.27

59 136 74
120
43 120 43

[81.5] 73.5 [81.5] 73.5


(97 max) (97 max)

179.5 Pg/M Pg/M

E Type
4/4X/12

dimensions indicated are not binding


and may be changed without notice

220
CM - CMA and MM - MMA enclosures size “104.27” insulated 830V version
hoods covers
inserts: page with 2 levers
CME .............. 10 + 2 (aux) poles + m 119
CME, CMCE 16 + 2 (aux) poles + m 124

insert centre distance:


104 x 27 mm

Covers G and LG version are not suitable to be used


with code pins. If this application is required please
contact ILME SpA.

description part No. entry part No. entry part No.


Pg M

with levers, side entry 1) CMO 16 X 21 MMO 16 X25 25


with levers, side entry 1) MMO 16 X32 32
with levers, side entry, high construction 1)
CMAO 16 X 21 MMAO 16 X32 32
with levers, side entry, high construction 1)
CMAO 16 X29 29 MMAO 16 X40 40
with levers, top entry 1) CMV 16 X 21 MMV 16 X25 25
with levers, top entry 1) MMV 16 X32 32
with levers, top entry, high construction 1)
CMAV 16 X 21 MMAV 16 X32 32
with levers, top entry, high construction 1)
CMAV 16 X29 29 MMAV 16 X40 40
with 4 pegs (for enclosures with 2 levers with gasket) CHC 24
with 4 pegs and gasket (for enclosures with 2 levers) 2) CHC 24 C

size 104.27
with 2 pegs (for enclosures with 1 lever with gasket) CHC 24 L
with 2 levers (for hoods with 4 pegs) CHC 24 G
with 1 lever (for hoods with 2 pegs) CHC 24 LG

1)
May be combined with housings: dimensions in mm dimensions in mm
- CMI/CMP/CMAP 16 CS
- MMP/MMAP 16 CS CMO X (CMAO X) and MMO X (MMAO X) CHC

12
1)
May be combined with housings: Pg/M
- CMO/CMAO 16 X and CMV/CMAV 16 X 63 (76) 120 43
- MMO/MMAO 16 X and MMV/MMAV 16 X

CHC C
120 43
179.5 59
17.5

120 43

CMV X (CMAV X) and MMV X (MMAV X)


Pg/M CHC L

12
68 (91)
120 43

43
CHC G
120
179.5 59
120 43

17.5

E
179.5 59
Type
4/4X/12
CHC LG

120 43

17.5

136 74
dimensions indicated are not binding
and may be changed without notice

221
CH - CA and MH - MA enclosures size “104.27” 180 °C version
housings and cover hoods and cover
inserts: page
CN RY .................... 24 poles + m 83
CNE RY .................. 24 poles + m 93
CP RY........................ 6 poles + m 127

insert centre distance:


104 x 27 mm

The covers for G versions cannot be used together with


coding pins. If this application is required, please
contact ILME SpA.

description part No. entry part No. entry part No. entry part No. entry
Pg M Pg M

bulkhead mounting, with levers CHIR 24 ---


surface mounting, with levers, high construction CAPR 24.21 21 MAPR 24.32 32

cover with 4 pegs (for housings) CHCR 24

with pegs, side entry CHOR 24 21 MHOR 24.25 25


with pegs, side entry, high construction CAOR 24.29 29 MAOR 24.40 40
with pegs, top entry CHVR 24 21 MHVR 24.25 25
with pegs, top entry, high construction CAVR 24.29 29 MAVR 24.40 40

cover with 2 levers (for hoods) CHCR 24 G


size 104.27

panel cut-out for bulkhead mounting housings in mm dimensions in mm dimensions in mm

ø 4.5
CHIR CHOR (CAOR) and MHOR (MAOR)

186.5 59
Pg/M
63 (76)
29
112 130

142.5 45.5 6 120 43

CAPR and MAPR CHVR (CAVR) and MHVR (MAVR)

Pg/M
186.5 59

32
35
68 * (91)
Pg Ø 5.5 81
M

132 45 4 120 43

144 57 * 69.5 for Pg 29 - M 40 versions

CHCR CHCR G

120 43

12

17.5

E
120 43
Type 186.5 59

4/4X/12

dimensions indicated are not binding


and may be changed without notice

222
CH - CA and MH - MA enclosures size “104.27” aggressive environments
inserts: page housings and cover hoods and cover
CD .......................... 64 poles + m 45
CT, CTS *) (10A) .... 64 poles + m 51
CDD ...................... 108 poles + m 58
CQE ........................ 46 poles + m 77
CN .......................... 24 poles + m 83
CCE ........................ 24 poles + m 92
CNE, CSE................ 24 poles + m 93
CSS ........................ 24 poles + m 101
CTE, CTSE *) (16A) 24 poles + m 109
CMSE ........ 10+2 (aux) poles + m 118
CMCE ........ 10+2 (aux) poles + m 118
CME .......... 10+2 (aux) poles + m 119
CME .......... 16+2 (aux) poles + m 124
CMCE ........ 16+2 (aux) poles + m 124
CX .......................... 4/8 poles + m 133
MIXO ........................ 6 modules 137÷151

insert centre distance: 104 x 27 mm


*) only for enclosure CHIW 24
description part No. entry part No. entry part No. entry part No. entry
Pg M Pg M

bulkhead mounting, with levers CHIW 24 ---


surface mounting, with levers, high construction CAPW 24.21 21 MAPW 24.32 32

cover with 4 pegs (for enclosures with 2 levers) CHCW 24

with pegs, side entry CHOW 24 21 MHOW 24.25 25


with pegs, side entry MHOW 24.32 32
with pegs, side entry, high construction CAOW 24.29 29 MAOW 24.32 32
with pegs, side entry, high construction MAOW 24.40 40
with pegs, top entry CHVW 24 21 MHVW 24.25 25
with pegs, top entry MHVW 24.32 32
with pegs, top entry, high construction CAVW 24.29 29 MAVW 24.32 32

size 104.27
with pegs, top entry, high construction MAVW 24.40 40

cover with 2 levers (for enclosures with 4 pegs) CHCW 24 G

with lever and gasket, top entry CHVW 24 G 21 MHVW 24 G32 32

panel cut-out for bulkhead mounting housings in mm dimensions in mm dimensions in mm

ø 4.5 CHIW CHOW (CAOW) and MHOW (MAOW)


179.5 59

Pg/M
63 (76)
29

142.5 45.5 6 120 43


112 130

CAPW and MAPW CHVW (CAVW) and MHVW (MAVW)


179.5 59 Pg/M

Ø 5.5 81 68 (91)
Pg
M
32
35 132 45 120 43
4
144 57

The covers for G versions cannot be used together CHCW CHCW G


with coding pins. If this application is required, please 120 43
contact ILME SpA.
12
17.5
120 43
179.5 59

E Type CHVW G and MHVW G


59
4/4X/12 120
43

73.5

dimensions indicated are not binding


179.5 Pg/M
and may be changed without notice

223
CH - CA and MH - MA enclosures size “104.27” EMC version
inserts: page housings and cover hoods and cover
for electromagnetic compatibility for electromagnetic compatibility
CD .......................... 64 poles + m 45
CT, CTS *) (10A) .... 64 poles + m 51
CDD ...................... 108 poles + m 58
CQE ........................ 46 poles + m 77
CN .......................... 24 poles + m 83
CCE ........................ 24 poles + m 92
CNE, CSE................ 24 poles + m 93
CSS ........................ 24 poles + m 101
CTE, CTSE *) (16A) 24 poles + m 109
CMSE ........ 10+2 (aux) poles + m 118
CMCE ........ 10+2 (aux) poles + m 118
CX .......................... 4/8 poles + m 133
MIXO ........................ 6 modules 137÷151

insert centre distance: 104 x 27 mm


*) only for enclosure CHIS 24

description part No. entry part No. entry part No. entry part No. entry
Pg M Pg M

bulkhead mounting, with levers CHIS 24 ---


surface mounting, with levers, high construction CAPS 24.21 21 MAPS 24.32 32

cover with 4 pegs (for enclosures with 2 levers) CHCS 24

with pegs, side entry CHOS 24 21 MHOS 24.25 25


with pegs, side entry MHOS 24.32 32
with pegs, side entry, high construction CAOS 24.29 29 MAOS 24.32 32
with pegs, side entry, high construction MAOS 24.40 40
with pegs, top entry CHVS 24 21 MHVS 24.25 25
with pegs, top entry MHVS 24.32 32
with pegs, top entry, high construction CAVS 24.29 29 MAVS 24.32 32
size 104.27

with pegs, top entry, high construction MAVS 24.40 40

cover with 2 levers (for enclosures with 4 pegs) CHCS 24 G

panel cut-out for bulkhead mounting housings in mm dimensions in mm dimensions in mm

ø 4.5 CHIS CHOS (CAOS) and MHOS (MAOS)


179.5 59

Pg/M
63 (76)
29

142.5 45.5 6 120 43


112 130

CAPS and MAPS CHVS (CAVS) and MHVS (MAVS)


179.5 59 Pg/M

Ø 5.5 81 68 (91)
Pg
M
32
35 120 43
132 45 4
144 57

The covers for G versions cannot be used together CHCS CHCS G


with coding pins. If this application is required, please 120 43
contact ILME SpA.
12
17.5
120 43
179.5 59

E Type
4/4X/12

dimensions indicated are not binding


and may be changed without notice

224