GRP-520 Quick Start v1.
00 2013/03/20
                        GRP-520
                        Quick Start
Package Checklist
The package includes the following items:
   One GRP-520 hardware module
   One Quick Start
   One companion CD
   One RS-232 cable (CA-0910)
   One 2G/3G antenna (ANT-421-02)
   Screw Driver
Related Documents and Software Utilities
Documents
  User Manual: GRP-520_User_Manual.pdf
  Quick Start: GRP-520_QuickStart.pdf
  CD: \napdos\GRP-520\Manual
  http://ftp.icpdas.com/pub/cd/usbcd/napdos/GRP-520/manual
 GRP-520 Dimensions (Unit: mm)
                        GRP-520 Quick Start -------1
                                           GRP-520 Quick Start v1.00 2013/03/20
 Appearance and Pin Assignments
                     COM Port & Power Input
             Terminal No.                   Pin Assignment
                            01                   RxD1
          COM1              02                   TxD1
                            03                   GND
                            04                    D+
          COM2
                            05                     D-
                            06                   RxD3
          COM3
                            07                   TxD3
                            08                  DC.+VS
          Power             09                  DC.GND
                            10                    F.G.
                      GRP-520 Quick Start -------2
                                                        GRP-520 Quick Start v1.00 2013/03/20
 LED indicators
    A.   PWR(Green):Power LED to indicate whether the external power is input or not. The
         description is as follows:
         The external power is active       The external power is not active
                      on                                  off
    B.   OS(Red):OS LED indicates if the OS is normal or fail.
                   Normal                                 Fail
             Heart beat (1 sec.)                  Always ON or OFF
    C.   FW(Red):This LED indicates the status of VxServer firmware (Serial port to 3G).
               Connected                          Connecting                    Fail
         500ms ON / 500ms OFF                   Blanking(4 sec)          Always ON or OFF
    D.   3G (Red):The LED indicates the status of 3G module.
               Registered                  3G/GPRS data transmit                Fail
         800ms ON / 800ms OFF              200ms ON, 200ms OFF           Always ON or OFF
                                   GRP-520 Quick Start -------3
                                                       GRP-520 Quick Start v1.00 2013/03/20
 Installation
  If users want to start GRP-520 normally, it needs to follow these steps to install the GRP-520
  below:
  A. Install the antenna
  B. Plug in the normal SIM card (Before apply the SIM card, confirm it is OK by mobile
      phone.)
  C. Plug the Ethernet cable if you need it.
  D. If you want to use the Micro SD card, please insert it into the slot.
  E. Turn the rotary switch to 0 (normal mode). The COM1 will be the console in position 1
      (debug mode), and the default username is “root”, default password is “root”.
  F. Connect the DC.+VS and DC.GND to the power supply.
  G. It is needed to wait about 20 ~ 30 seconds for OS booting. After finishing the process,
      GRP-520 would be in normal operation mode and the OS LED would blank as heart beat
      per 1 sec.
  H. It is needed to wait about 30 ~ 60 seconds to search the 3G/2G base and register to the ISP.
      After finishing the process, the 3G LED would blank per 1 sec.
                                  GRP-520 Quick Start -------4
                                                        GRP-520 Quick Start v1.00 2013/03/20
 Web Utility
1. Login
     Default username = “admin”, and default password = “admin”
     Default IP = “192.168.255.1”
     Default Mask = “255.255.0.0”
     Default Gateway = “192.168.0.1”
     After login, the screenshot is showed as below:
                                   GRP-520 Quick Start -------5
                                                          GRP-520 Quick Start v1.00 2013/03/20
2. Ethernet
     This page provides the basic settings of Ethernet:
   (1) Mode:
       .“Static”: set as static IP
       .”DHCP”: set IP via DHCP protocol.
   (2) IP Address: IP of Ethernet.
   (3) Mask: the Mask of the gateway.
   (4) Gateway: IP of the gateway.
3. 3G Configure
      This page provides basic settings of 3G network.
   (1) PIN Code: PIN Code are 4 character number provided by SIM Card provider
   (2) Phone Number: usually fill it as “*99***1#” or “*99#”. The number is depended on SIM
       Card provider
   (3) APN: Access Point Name, please ask your SIM Card provider.
   (4) User Name: the username for dial-up. Please ask your SIM Card provider.
   (5) Password: the password for dial-up. Please ask your SIM Card provider.
   (6) Auto-Dialing: Enable this function to dial-up to 3G network after power on.
4. Routing
     This page provides routing rule configuration.
                                   GRP-520 Quick Start -------6
                                                       GRP-520 Quick Start v1.00 2013/03/20
    (1) IP: IP address.
    (2) Mask: the mask will effect how many IP this rule manages.
        ”24” = 255 IPs, “28” = 16 IPs, “32” = 1 IPs.
    (3) Target: the target interface of the rule.
    (4) For example:
        The Rule 0: This rule will push the socket packages from the address 192.168.27.0 ~
        192.168.27.255 forward to “ppp0” (3G network).
        The Rule 0: This rule will push the socket packages from the address 192.168.0.0 ~
        192.168.0.15 forward to “ppp0” (3G network).
5. Port Mapping (Port Forward)
     This page provides Port Mapping rule configuration.
                                  GRP-520 Quick Start -------7
                                                        GRP-520 Quick Start v1.00 2013/03/20
    (1) Type: the protocol type. There are “TCP” and “UDP”
    (2) From: the interface that the socket comes from.
        ”ppp0” is 3G interface.
    (3) Port: the port that the socket comes from.
    (4) Target IP: the IP that the socket goes forward.
    (5) Target Port: the Port of the “Target IP”.
    (6) For example:
        The Rule 0: This rule will bind the socket from the “ppp0” and Port=”10080” with
        192.168.0.10:80.
        The Rule 1: This rule will bind the socket from the “ppp0” and Port=”10021” with
        192.168.0.10:21.
6. Password
     The user can change the password of the web utility here.
    (1) Password: new password.
    (2) Confirm: confirm the password again.
7. The advance settings of web utility
     Please refer the user manual of GRP-520.
 Technical Support
    1. ICP DAS Service : service@icpdas.com
    2. GRP-520 software Website:
         http://m2m.icpdas.com/GRP-520.html
                                   GRP-520 Quick Start -------8