grid | power V M

Series OSP.HC/OSP.HB
Similar to the illustration,
AquaGen® optional

Vented lead-acid battery

www.hoppecke.com
grid | power V M Series OSP.HC

Typical applications: Your benefits:


Power Supply Systems Very good high-current capability –
Uninterruptible power supply (UPS) low investment costs due to innovative electrode structure
Traffic Systems Very high expected service life –
- Signalling due to optimized low-antimony selenium alloy
- Lighting Higher short-circuit safety even during the installation –
based on HOPPECKE system connectors
Extremely extended water refill intervals up to maintenance-
free – optional use of AquaGen® recombination system
minimizes emission of gas and aerosols1

grid | power V M Series OSP.HB

Typical applications: Your benefits:


Power Supply Systems Very good high-current capability –
Uninterruptible Power Supply (UPS) due to innovative electrode structure
Traffic systems Very high expected service life –
- Signalling due to optimized low-antimony selenium alloy
- Lighting HOPPECKE SST terminal design – compatible plastic
IT/Telecom moulded terminals for testing according to the IEEE 450
Emergency lighting installations External insulated inter-cell connector –
individual testing of the single cell voltages in the block
Extremely extended water refill intervals up to maintenance-
free – optional use of AquaGen® recombination system
minimizes emission of gas and aerosols1

grid | power V M grid | power V M


Series OSP.HC Series OSP.HB

1
Similar to sealed lead-acid batteries

2
Capacities dimensions and weights

C10/1.80 V C5/1.75 V C3/1.70 V C1/1.65 V Weight Weight electrolyte max.* Length L max.* Width W max.* Height H
Series OSP.HC Type Fig.
Ah Ah Ah Ah kg kg (1.24 kg/l) mm mm mm
grid | power V M 2-125 3 OSP.HC 105 125 101 91 71 15.3 5.1 105 208 420 A
grid | power V M 2-170 4 OSP.HC 140 167 135 122 95 16.7 4.9 105 208 420 A
grid | power V M 2-210 5 OSP.HC 175 209 169 152 118 18.2 4.7 105 208 420 A
grid | power V M 2-250 6 OSP.HC 210 250 203 183 142 21.7 5.9 126 208 420 A
grid | power V M 2-290 7 OSP.HC 245 292 237 213 166 23.1 5.8 126 208 420 A
grid | power V M 2-330 8 OSP.HC 280 334 270 244 189 26.5 7.0 147 208 420 A
grid | power V M 2-370 9 OSP.HC 315 361 292 263 204 33.2 11.3 189 208 420 A
grid | power V M 2-410 10 OSP.HC 350 401 324 293 227 33.8 10.0 189 208 420 A
grid | power V M 2-440 11 OSP.HC 385 441 357 321 249 35,4 9,2 189 208 420 A
grid | power V M 2-360 4 OSP.HC 340 359 308 285 214 40.0 15.0 147 208 710 A
grid | power V M 2-450 5 OSP.HC 425 448 385 357 268 43.4 14.5 147 208 710 A
grid | power V M 2-540 6 OSP.HC 510 538 462 429 322 46.7 14.1 147 208 710 A
grid | power V M 2-630 7 OSP.HC 595 628 540 498 375 50.4 13.6 147 208 710 A
grid | power V M 2-720 8 OSP.HC 680 718 615 570 429 53.3 13.1 147 208 710 A
grid | power V M 2-810 9 OSP.HC 765 807 695 642 482 66.3 18.0 215 193 710 B
grid | power V M 2-900 10 OSP.HC 850 897 770 714 536 69.9 17.4 215 193 710 B
grid | power V M 2-990 11 OSP.HC 935 987 850 783 590 72.9 17.0 215 193 710 B
grid | power V M 2-1080 12 OSP.HC 1020 1076 925 855 643 83.7 22.1 215 235 710 B
grid | power V M 2-1170 13 OSP.HC 1105 1166 1000 927 697 87.3 21.6 215 235 710 B
grid | power V M 2-1260 14 OSP.HC 1190 1256 1080 999 751 90.3 21.3 215 235 710 B
grid | power V M 2-1350 15 OSP.HC 1275 1345 1155 1068 804 101.0 26.2 215 277 710 B
grid | power V M 2-1440 16 OSP.HC 1360 1435 1235 1140 858 104.2 25.8 215 277 710 B
grid | power V M 2-1530 17 OSP.HC 1445 1525 1310 1212 911 107.4 25.5 215 277 710 B
grid | power V M 2-1590 15 OSP.HC 1575 1587 1420 1284 898 122.3 31.7 215 277 855 B
grid | power V M 2-1700 16 OSP.HC 1680 1693 1515 1368 958 126.2 31.1 215 277 855 B
grid | power V M 2-1810 17 OSP.HC 1785 1799 1610 1455 1018 129.9 30.7 215 277 855 B
grid | power V M 2-1920 18 OSP.HC 1890 1904 1705 1542 1077 160.6 49.2 215 400 815 C
grid | power V M 2-2140 20 OSP.HC 2100 2116 1895 1713 1197 168.7 47.3 215 400 815 C
grid | power V M 2-2560 24 OSP.HC 2520 2539 2270 2055 1437 209.9 61.8 215 490 815 D
grid | power V M 2-2780 26 OSP.HC 2730 2751 2460 2226 1556 218.2 60.9 215 490 815 D
grid | power V M 2-3000 28 OSP.HC 2940 2962 2650 2397 1676 225.6 59.8 215 490 815 D
grid | power V M 2-3220 30 OSP.HC 3150 3174 2840 2568 1796 250.9 71.6 215 580 815 D
grid | power V M 2-3440 32 OSP.HC 3360 3385 3030 2739 1915 259.6 70.3 215 580 815 D
grid | power V M 2-3660 34 OSP.HC 3570 3597 3220 2910 2035 267.5 69.0 215 580 815 D
grid | power V M 2-3880 36 OSP.HC 3780 3809 3410 3081 2155 274.9 68.3 215 580 815 D

C10, C5, C3 and C1 = Capacity at 10 h, 5 h, 3 h and 1 h discharge * according to DIN 40736-1 data to be understood as maxiumum values

C10/1.80 V/Z C5/1.75 V/Z C3/1.70 V/Z C1/1.65 V/Z Weight Weight electrolyte max. Length L max. Width W max. Height H
Series OSP.HB Type Fig.
Ah Ah Ah Ah kg kg (1.24 kg/l) mm mm mm
grid | power V M 6-50 OSP.HB 6 V 50 80 70 63 47 24.3 7.0 148 205 352 A
grid | power V M 6-100 OSP.HB 6 V 100 120 105 95 70 27.4 5.0 148 205 352 A
grid | power V M 6-150 OSP.HB 6 V 150 160 140 126 93 39.5 8.5 274 205 352 B
grid | power V M 6-200 OSP.HB 6 V 200 240 210 189 140 47.5 6.5 274 205 352 B

C10, C5, C3 and C1 = Capacity at 10 h, 5 h, 3 h and 1 h discharge

3
max. max.

min. min.

Capacities dimensions and weights Pb Pb


max.

min.

max.
Low
Antimony
Low
Antimony

min.

+ + + +
Pb
Fig. A Series OSP.HC Fig. B Series OSP.HC +
Fig.
+
C Series
+
OSP.HC
+
Fig. D Series OSP.HC
+ + + + Low
Antimony

Pb

+ + + + + +
+ + + + + +
+ +
max.
Low
Antimony

+ + + +
W

min.

+ + + +
+ + + +
W

L + + L + + + +
+ +

W
+ + Pb
+ +
grid | power V M 2-125 - + grid | power V+M 2-810 -
+ + + + +
grid | power V M 2-720 grid | power V M 2-1810
+ +
Low
Antimony

H
L + +
+

grid | power V M 2-1920 -+ + L + +


grid | power V M 2-2140

+ + + +
grid | power V M 2-2560 -
+ + grid | power V +M 2-3880 +

Design life: up to 20 years


Optimal environmental compatibility – closed loop for recovery of materials in an accredited recycling system

max.

min.

max. max.

min. min.
Low
Antimony

Pb

Fig. A Series OSP.HB Fig. B Series OSP.HB


Low
Low
Antimony

Pb
Antimony

Pb

max. max. max. max.

min. min. min. min.


H

Low Low
Antimony Antimony
Low Low

Pb Pb
Antimony Antimony

Pb Pb

W L W L

grid | power V M 6-50 - grid | power V M 6-150 -


grid | power V M 6-100 grid | power V M 6-200

Design life: up to 20 years


Optimal environmental compatibility – closed loop for recovery of materials in an accredited recycling system

4
Notes

5
D - 59929 Brilon
Bontkirchener Str. 1

www.hoppecke.com
Tel.: +49 (0) 2963 61-374
Fax: +49 (0) 2963 61-270
HOPPECKE Batterien GmbH & Co. KG

E-Mail: reservepower@hoppecke.com

05/2018 EN grid | power V M All details in this brochure are based on state-of-the-art technology. Our products are subject to constant development. We therefore reserve the right to make changes.