0% found this document useful (0 votes)
126 views2 pages

Universal Compressor SC15G Specs

This document provides specifications for a universal compressor that uses R134a refrigerant and operates on 220-240V 50/60Hz power. It lists technical details such as approved standards, compressor dimensions, motor specifications, cooling requirements, capacity and power consumption data, and available accessories. Performance is rated according to EN 12900 and ASHRAE LBP standards for various evaporating temperatures and voltage/frequency configurations.

Uploaded by

Sergiu Rusu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views2 pages

Universal Compressor SC15G Specs

This document provides specifications for a universal compressor that uses R134a refrigerant and operates on 220-240V 50/60Hz power. It lists technical details such as approved standards, compressor dimensions, motor specifications, cooling requirements, capacity and power consumption data, and available accessories. Performance is rated according to EN 12900 and ASHRAE LBP standards for various evaporating temperatures and voltage/frequency configurations.

Uploaded by

Sergiu Rusu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

SC15G

Universal Compressor
R134a
220-240V 50/60Hz
General
Code number 104G8520
Approvals EN 60335-2-34,
CCC, EAC, KC
Compressors on pallet 80

Application
Frequency Hz 50 60
Application LBP/HBP LBP
Evaporating temperature °C -25 to 15 -25 to -5
Voltage range V 187 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)

Cooling requirements S = Static cooling normally sufficient


O = Oil cooling
Frequency Hz 50 60 F1 = Fan cooling 1.5 m/s
Application LBP MBP HBP LBP MBP HBP (compressor compartment temperature
32°C F1 F2 F2 F1 – – equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
38°C F1 F2 F2 F1 – –
SG = Suction gas cooling normally sufficent
43°C F1 F2 F2 F1 – – – = not applicable in this area
Remarks on application: HBP at 198 - 254V 50Hz only.

Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 14.8 –
Cut in Current, HST | LST A 14.8 –
Resistance, main | start winding (25°C) Ω 5.0 13.7

Design
Displacement cm3 15.28
Oil quantity (type) cm3 500 (polyolester)
Maximum refrigerant charge g 1300
Free gas volume in compressor cm3 1410
Weight without electrical equipment kg 13.1

Dimensions
Height mm A 209
B 203
B1 183
B2 100
Suction connector location/I.D. mm | angle C 10.2 | 37°
material | comment Copper | Rubber plug
Process connector location/I.D. mm | angle D 6.2 | 37°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 6.2 | 37°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09
Remarks:

October 2018 DES.D.402.K3.02 1/2


EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 164 206 290 424 568 672 728 908 1110 1207 1340 1600
Power cons. in W 233 259 307 376 440 478 497 549 595 613 634 667
Current cons. in A 2.21 2.28 2.40 2.59 2.78 2.92 2.99 3.20 3.42 3.52 3.64 3.88
COP in W/W 0.71 0.80 0.95 1.13 1.29 1.40 1.46 1.65 1.87 1.97 2.11 2.40

ASHRAE LBP 220V, 50Hz, fan cooling F2


Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 203 255 358 523 703 831 901 1124 1377 1499 1665 1993
Power cons. in W 233 259 307 376 440 478 497 549 595 613 634 667
Current cons. in A 2.21 2.28 2.40 2.59 2.78 2.92 2.99 3.20 3.42 3.52 3.64 3.88
COP in W/W 0.87 0.99 1.17 1.39 1.60 1.74 1.81 2.05 2.31 2.44 2.62 2.99

EN 12900 Household (CECOMAF) 220V, 60Hz, fan cooling F2


Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 262 298 376 515 677 797 863
Power cons. in W 330 350 388 447 506 544 563
Current cons. in A 1.99 2.05 2.17 2.37 2.59 2.74 2.82
COP in W/W 0.79 0.85 0.97 1.15 1.34 1.47 1.53

ASHRAE LBP 220V, 60Hz, fan cooling F2


Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 326 371 468 639 840 988 1070
Power cons. in W 328 347 386 444 502 540 560
Current cons. in A 1.97 2.03 2.16 2.36 2.57 2.73 2.81
COP in W/W 0.99 1.07 1.21 1.44 1.67 1.83 1.91

Accessories for SC15G Figure Code number Test conditions EN 12900/CECOMAF ASHRAE LBP
PTC starting device 6.3 mm spade connectors – Condensing temperature 55°C 55°C
a1
4.8 mm spade connectors – Ambient temperature 32°C 32°C
Starting relay 6.3 mm spade connectors a2 117U6005 Suction gas temperature 32°C 32°C
Cover b 103N2009 Liquid temperature 55°C 32°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5017
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC g – Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919

Nidec GA Compressors accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Nidec GA Compressors reserves the right to alter its products without notice.
This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary to specifications already agreed. All trademarks in this
material are the property of the respective companies. Secop and the Secop logotype are trademarks of Nidec Global Appliance Germany GmbH. All rights reserved. www.secop.com

2/2 DES.D.402.K3.02 October 2018

You might also like