Test Facilities at Dqa (N) : 0 o o o o

The document describes test facilities available at the Chief Quality Assurance Establishment in Bangalore, India. It lists 29 test facilities, including chambers for high/low temperature testing, humidity testing, corrosion testing, vibration testing, and electrical testing. The facilities can test samples up to 1000kg in size and have capabilities for temperature ranges from -60°C to 3000°C, humidity from 30-95%, and vibrations up to 2000Hz and 100G. Contact information is provided for facility inquiries.

Uploaded by

siva sankar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
370 views5 pages

Test Facilities at Dqa (N) : 0 o o o o

The document describes test facilities available at the Chief Quality Assurance Establishment in Bangalore, India. It lists 29 test facilities, including chambers for high/low temperature testing, humidity testing, corrosion testing, vibration testing, and electrical testing. The facilities can test samples up to 1000kg in size and have capabilities for temperature ranges from -60°C to 3000°C, humidity from 30-95%, and vibrations up to 2000Hz and 100G. Contact information is provided for facility inquiries.

Uploaded by

siva sankar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

TEST FACILITIES AT DQA(N)

Name of the Sl. Test Facility Range Remarks


Establishment and No.
address, name of
Nodal officer and
contact No.
(1) (2) (3) (4) (5)
Chief Quality 1 Dry Heat (High Temperature) Amb to 3000C JSS 55555
Assurance +/-3o C<100oC IS 9000,
Establishment (WE) Chamber Size: 1x1x1 m +/-5o C>100oC DEF 133,
Jalahalli Camp Road MIL 810 &
Yashwanthpur PO Max. Weight & Max. JSS 50101
Bangalore- 560 022 permissible size of test sample
(width X height X depth) (*):
Cdr G 200 kg, 0.5x0.5x0.5m
Subramanyam
2 Damp Heat ( Steady State) 400C+/-2oC JSS 55555
Phone No.: 95%RH(Min) IS 9000,
080-23571176 Extn Chamber Size: 1.5x1.5x1.5m DEF 133 &
125 JSS 50101
E-mail:cqae-bng- Max. Weight & Max.
dgqa@nic.in permissible size of test sample
(width X height X depth) (*):
300 kg, 0.75x0.75x0.75m

3 Damp heat ( Cyclic) / Tropical Amb to JSS 55555


exposure 550C+/-2oC, IS 9000,
95% RH(Min) DEF 133,
Chamber Size: 1.5x1.5x1.5m MIL 810 &
JSS 50101
Max. Weight & Max.
permissible size of test sample
(width X height X depth) (*):
300 kg, 0.75x0.75x0.75m

4 Damp Heat (Moisture Amb to JSS 50101


Resistance) 0 o
65 C+/-2 C,
95% RH(Min)
Chamber Size: 1.5x1.5x1.5m

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
300 kg, 0.75x0.75x0.75m
5 Dry Cold (Low Temperature) Up to – JSS 55555
600C+/-3oC IS 9000,
Chamber Size: 1x1x1m DEF 133,
MIL 810 &
Max. Weight & Max. JSS 50101
permissible size of test sample
(width X height X depth) (*):
300 kg, 0.5x0.5x0.5m

6 Mould Growth / Fungus 29oC+/-1oC JSS 55555


Resistance 90%RH(Min) IS 9000,
DEF 133,
Chamber Size: 1.2x1.2x1.2m MIL 810 &
JSS 50101
Max. Weight & Max.
permissible size of test sample
(width X height X depth) (*):
200 kg, 0.6x0.6x.0.6m

7 Corrosion (Salt) 350C+/-2oC JSS 55555


90 to 95% RH IS 9000,
Chamber Size: 1.5x1.5x1.5m DEF 133,
MIL 810 &
Max. Weight & Max. JSS 50101
permissible size of test sample
(width X height X depth)
(*):500 kg, 0.75x0.75x0.75m

8 Rain 200kPa+/-15% JSS 55555


450 litres +/- IS 9000,
Chamber Size: 2x2x2m 10% per hour DEF 133,
MIL 810 &
Max. Weight & Max. JSS 50101
permissible size of test sample
(width X height X depth)
(*):1000 kg, 1x1x1m

9 Drip Proof 1m from top of JSS 55555


equipment DEF 133,
Chamber Size: 1.0x1.0m JSS 50101

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
NA , 0.75 x 0.75m
10 Contamination 50oC+/-2 o C JSS 55555
DEF 133.
Chamber Size: 1x1x1m

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
200 kg, 0.5x0.5x0.5m

11 Rapid temperature cycling / - 40 to + 1000 JSS 55555


Thermal shock C,+/-2oC IS 9000,
95% RH(Min) DEF 133,
Chamber Size: 1x1x1m MIL 810 &
JSS 50101
Max. Weight & Max.
permissible size of test sample
(width X height X depth) (*):
100 kg, 0.5x0.5x0.5m

12 Shock NSS I & II, JSS 55555


Half Sine
Chamber Size: 0.75x0.75m pulse only
base size

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
500 kg for NSS-I & 800 kg for
NSS-II including jig
0.75x0.75x1.0m

13 Vibration ( Manual sweep & 5 to 33 Hz JSS 55555,


Endurance at fixed 0.125 mm DEF 133
frequencies) constant disp.

Chamber Size: 1x1 m base


size

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
500 kg including jig 1x1x1 m
14 Vibration 7 to 350 Hz, JSS 50101
( Endurance by sweep) 2G
tolerance in
Chamber Size: 0.15x0.15 m accelerations
base size <150Hz +/-
15%
Max. Weight & Max. >150Hz +/-
permissible size of test sample 25%
(width X height X depth) (*): 2
kg including jig 0.1x0.1x0.1 m

15 Random/Sine Vibration 5 to 2000 Hz, JSS 55555,


100G MIL & DQAN
Chamber Size: 1x1 m base Guideline
size

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
400 kg including jig 1x1x1 m

16 Bump Machine 10, 40g, JSS 55555


6, 11 ms IS 9000,
Chamber Size: 1x1 m 1 or 2 bump DEF 133,
base size per sec. JSS 50101

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
250 Kg, including jig
0.75x0.75x0.75 m

17 Bump Machine 0 to 100g, 5 to


20 ms ,1
Chamber Size: 1.3 x 1.3 mtr bump per sec.

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
1000 kgs

18 Ship motion +/- 15 deg


fixed
Chamber Size: 1.2x1.2 m
base size

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
200 kg 0.9x0.9x0.9 m
19 High voltage Break Down 10 KV NES

20 Insulation Up to 1000 V NES


DC

21 Load Tank 40Kw, 3


phase

22 Shock & Vibration 0.7 to 3000 Hz


Measurement System , +600g

23 3 phase Variable Power Supply 0v – 460v AC ,


2000Amp

24 400Hz Variable Frequency 0v – 250v AC,


Supply 40 – 450 Hz

25 Multimeter 750v AC,


1000v DC

26 Lux Meter 0.1mv –


200mv

27 IR Laser Temperature Sensor -20 to +65


Deg

28 Clamp Meter AC/DC 0 – 400 amp,


1000v DC,
750v AC

29 Clamp Meter AC 1000Amp,


750v

(*) - Following tolerances are permissible on the sample size mentioned in Col. (3) above.

(i) +30% of any one side, if only one side of the sample exceeds the maximum
permissible size of the sample.

(ii) +15% of any two sides, if only 2 sides of the sample exceeds the maximum
permissible size of the sample.

(iii) +10% of all three sides, if all the three sides of the sample exceed the
maximum permissible size of the sample.