Cable Testing Standards IS-7098-1985

The document outlines various types of tests performed on cables according to IS – 7098 (Part 2) - 1985, including type tests, acceptance tests, and routine tests. Type tests extensively evaluate the conductor, insulation, outer sheath, and overall cable design. Acceptance tests examine critical characteristics. Routine tests check resistance, insulation, and voltage withstand. Optional tests also exist, such as cold impact tests on the outer sheath.

Uploaded by

JAY PARIKH
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
185 views2 pages

Cable Testing Standards IS-7098-1985

The document outlines various types of tests performed on cables according to IS – 7098 (Part 2) - 1985, including type tests, acceptance tests, and routine tests. Type tests extensively evaluate the conductor, insulation, outer sheath, and overall cable design. Acceptance tests examine critical characteristics. Routine tests check resistance, insulation, and voltage withstand. Optional tests also exist, such as cold impact tests on the outer sheath.

Uploaded by

JAY PARIKH
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 2

CABLE TESTS AS PER IS – 7098 (PART 2) - 1985

1) TYPE TEST

a) Test on Conductor
i) Annealing test (for copper)
ii) Tensile test (for aluminium)
iii) Wrapping test (for aluminium)
iv) Resistance test.

b) Tests for armouring wires / strips.


c) Test for thickness of insulation and sheath

d) Physical tests for insulation


i) Tensile strength and elongation at break.
ii) Ageing in air oven.
iii) Hot test
iv) Shrinkage test
v) Water absorption (gravimetric)

e) Physical tests for outer sheath.


i) Tensile strength and elongation at break.
ii) Ageing in air oven.
iii) Hot test
iv) Shrinkage test

f) Bleeding and blooming test (for outer sheath)


g) Partial Discharge test.

h) Bending test
i) Dielectric Power factor test
i) As a function of voltage
ii) As a function of temperature

K) Insulation resistance (volume resistivity ) test


l) Heating cycle test
m) Impulse withstand test
n) High voltage test
o) Flammability test

2) ACCEPTANCE TEST

a) Annealing test (for copper)


b) Tensile test (for aluminium)
c) Wrapping test (for aluminium)
d) Conductor resistance test
e) Test for thickness of insulation and sheath
f) Hot test for insulation
g) Tensile strength and elongation at break test for insulation and sheath
h) Partial discharge test (for screened cable only)
i) High voltage test
j) Insulation resistance (volume resistivity) test

3) ROUTINE TEST

a) Conductor resistance test


b) Partial discharge test (for screened cable only)
c) High voltage test

4) OPTIONAL TEST

a) cold impact test for outer sheath