Giving neonates a future
Comprehensive respiratory support solutions
Our heart beats for premature infants and newborns
Our full commitment and knowledge are focused on lung-protective solutions for respiratory
support in order to ease the workload of hospital staff in the best way possible. With our
innovations, we contribute to the survival of the smallest patients and support the gentlest possible
start to life.
Premature infants and newborns need a familiar environment. Like the nursing staff, we also
consider ourselves to be a part of this family. We work carefully, are solution-oriented, and respond
to individual needs. In doing so, our focus is always on the welfare of the small patients and the
quality of our products, just as it is on good service – worldwide. Longstanding relationships with
customers and partners are the basis of a meaningful exchange of experiences and respectful
collaboration.
We develop and produce nCPAP systems and consumables for premature infants and newborns for
clinical application in the delivery room, in the intensive care ward and during transport. For more
than 20 years.
Giving neonates a future
Everything you need As the only manufacturer, we offer solutions
and products for the complete spectrum of
from one source non-invasive respiratory support for premature
infants and newborns.
You get a large, comprehensive and
coordinated toolkit for the NIV therapy of your
small patients, from CPAP to assisted respiratory
support to non-invasive HFO.
Our accessories are perfectly coordinated to
medin devices. They can also be used with
many other devices and thus provide you with
varied and, above all, practical solutions.
medinSINDI®
nCPAP and high-flow
With the nCPAP and high-flow modes, medinSINDI offers a reliable and economical solution
for basic NIV therapy of small patients. In combination with the Medijet generator, medinSINDI
measures CPAP pressure and respiratory rate. In addition, alarm functions such as the upper and
lower pressure limit and a disconnection alarm offer additional security.
Through the integrated oxygen/compressed air blender, medinSINDI enables precise adjustment of
the flow and the oxygen concentration.
nCPAP and high-flow
Spontaneous respiratory rate display
5 hours of operation on battery power
Pressure and oxygen measurement with alarm
Giving neonates a future
medinCNO®mini
nCPAP and high-flow
medinCNOmini offers the basic nCPAP and high-flow functions of a modern CPAP device.
In addition, the device has a special ApneaCPAP mode. With the aid of the MediTRIG respiratory
trigger, the spontaneous breathing is detected near the patient and without any additional sensors.
MediTRIG can be individually adapted to the patient’s spontaneous breathing. In the event of
apnea, the patient’s inspiration is stimulated through automatically activated mechanical breaths.
All basic modes for NIV respiratory support
High-flow
Leakage compensation
MediTRIG: Integrated trigger and apnea monitoring without additional sensor
Comprehensive alarm menu for optimal adaptation to the environment
medinCNO® nCPAP device with nHFV
medinCNO is a versatile nCPAP device
which is used to provide respiratory support
to premature infants and newborns. In
combination with Medijet®, the compact
device is a stand-alone system and meets all
requirements for non-invasive nCPAP therapy.
With five modes (CPAP, ApneaCPAP, NIPPV,
SNIPPV, Oscillation), medinCNO offers
comprehensive non-invasive support in neona-
tology and is the only nCPAP device with nHFV.
nCPAP with nHFV
Synchronized SNIPPV
Apnea monitoring
MediTRIG: Integrated trigger without
additional sensor
Leakage compensation
medin-NC3®
The new generation of non-invasive respiratory support
medin-NC3 is the first turbine-driven CPAP device for non-invasive respiratory support for premature
infants and newborns. The high-performance turbine makes the device independent of a fixed
compressed air supply.
The proven MediTRIG technology is used in the ApneaCPAP mode. Powerful leakage compensation
offsets leakages to ensure stable and effective therapy.
All basic modes for NIV respiratory support
High-flow
Leakage compensation in all modes
MediTRIG: Integrated trigger and apnea monitoring without additional sensor
Independent of compressed air through a turbine
Gas blender for compressed air and O2
Versatile
The air/oxygen blenders from medin can be used for a variety of applications: Oxygen therapy,
EasyCPAP therapy with the Medijet generator, BubbleCPAP with Miniflow interface or Pediflow NIV
mask as well as nHFT therapy with medin high-flow cannula
medinBlender 1090
The medinBlender 1090 is a mechanical gas
blender with two integrated flow meters
(0-15 L/min and 0-3.5 L/min) for nCPAP,
BubbleCPAP therapy and high-flow applications
in neonatology and pediatrics as well as
conventional oxygen therapy in adults.
High degree of accuracy at low flow rates
Continuous oxygen adjustment from 21%
to 100%
Double flow meter: Flow adjustment from 0
to 15 L/min and 0 to 3.5 L/min
Alarm system in the event of a decrease in
pressure
Bleed flow can be switched off
medinBlender 1085_15
The medinBlender 1085_15 is a mechanical gas
blender with an integrated flow meter (0-15 L/
min) for nCPAP, BubbleCPAP therapy and high-
flow applications.
The inlet pressure for air and oxygen is
between 3.5 and 6 bar (50 psi). Connection
to the central gas supply and oxygen bottles is
possible.
Continuous adjustment from 21% to 100%
oxygen
Flow adjustment from 0 to 15 L/min.
Alarm system in the event of a decrease in
pressure
Giving neonates a future
BubbleCPAP
Easy application
In the case of the BubbleCPAP, positive pressure is applied to the airways during inspiration and
expiration. Pressure is generated through the expired breathing gas being directed into a water
container (bubbler). A dip tube (surge chamber) is on the end of the expiratory ventilation tube.
The level of the CPAP pressure depends on how deep the end of the cylinder is immersed into the
sterile water.
This simple CPAP system was used for the first time in the early 1970s (Gregory 1971) and it has
been used worldwide since then. In 1987, it was demonstrated (Avery 1987) that the incidence
of BPD (bronchopulmonary dysplasia) can be reduced using BubbleCPAP . As a result, the system
presumably became the most frequently used CPAP application by this time at the latest.
It consists only of:
• Air/oxygen blender: medinBLENDER
• Bubble bottle for CPAP pressures of 0 to 9.5 cm H2O
• Breathing circuit: 2-tube system 5801 HAMILTON-H900
• Respiratory gas humidifier HAMILTON-H900
• nCPAP interface: medin Miniflow with masks and prongs
George A. Gregory, M.D. N Engl J Med 1971; 284:1333-1340 June 17
Avery, ME January 1987; Pediatrics. 79 (1): 26–30
Miniflow® Miniflow is our interface for CPAP/NIV therapy
using conventional ventilators. The interface is
Passive nCPAP interface connected with the inspiratory and expiratory
branches of the tubing system with the
ventilator or flow source.
Combining Miniflow with ventilators enables
CPAP therapy and non-invasive ventilation
modes such as NIPPV. In this way, the therapy
parameters are controlled as usual via the
ventilator. As needed, pressure measurement
near the patient can be connected to the
Miniflow. The single-use interface allows all
forms and modes of modern NIV therapy for
premature infants and newborns.
Compatible with many ventilators and
BubbleCPAP systems
Minimal dead space
Flexible, swiveling adapter for positioning
the prong and mask
Patented flextubes for easy application
Low noise level
Giving neonates a future
Medijet® – Active nCPAP interface
Medijet is our active nCPAP generator and is used on the medin devices medin-NC3, medinCNO,
medinCNOmini and medinSINDI. In addition, the interface can also be combined with several
special ventilators.
Medijet is quieter than comparable nCPAP generators (Kirchner 2012) and features a high level of
comfort.
Medijet actively generates CPAP pressure using a modified Benveniste valve (Benveniste 1976),
that is, directly in the generator, and thus the continuous positive pressure in the patient’s airway
without an additional valve in the NIV device. As a result, Medijet is connected to the device with
only a single-tube system. This facilitates handling and patient positioning.
Low noise level
Pressure trigger and spontaneous breath detection without additional sensor
Flexible adapter for positioning prong and mask
Patented flextubes for easy application
Based on the Benveniste valve with volume reservoir
Kirchner L. Neonatology 2012; 101 (2):95-100 Epub 2011 Sep 17
Benveniste D. J Pediatr 1976; 88: 1015-9.
Pediflow® – Non-invasive ventilaton mask
For babies up to 10 kg
Pediflow is a mask for non-invasive ventilation for babies aged six to eight months and weighing up
to 10 kg. For easy and secure fixation, we have developed a special headgear which can be easily
adapted to the head of the small patient.
Pediflow is a single-use product with a good price-performance ratio and it is suitable for ventilators
with 2-tube systems.
Flexible and comfortable
Pediflow is made of 100% flexible silicone in order to prevent pressure points or damage. For the
same reason, the headgear is made in one piece and designed so that it can be optimally adjusted
to the patient’s head.
Simple adjustment
Secure fixation
For infants up to 10 kg
For the acute phase
Can be combined with ventilators and BubbleCPAP
Giving neonates a future
Nasal cannula for high flow Soft and kind to the skin
The medin high flow nasal cannula is made
oxygen therapy out ouf soft and skin compatible silicone which
helps to perfectly balance therapy and wearing
comfort. Even the smallest cannula size provides
flow rates up to 8 LPM and therefore, fulfill the
current knownledge of the application of high
flow oxygen therapy in neonatology (Roehr
2016)
The further cannula sizes allows the use in
babies and infants in combination with a
suitable ventilator, for example from Hamilton
Medical.
High degree of patient comfort
Low noise level and system stagnation
pressure
Individual fixation, gentle to the skin
Anatomically adapted shape of the prongs
Roehr, Charles C. Oxford nasal High Flow Therapy Meeting, 2015; Clin Perinatal
43 (2016) 693–705
Masks and prongs
Our masks and prongs are suitable for single use in combination with Medijet and Miniflow. Both
products are very well tolerated by premature infants and newborns and are equally effective in
application.
High-quality, biocompatible silicone ensures a high degree of wear comfort
Can be combined with Medijet and Miniflow
Anatomically optimized shape
Available in different sizes
Nasal masks
Our nasal masks are available in five sizes and
feature a high degree of wear comfort. The soft
cushion and the anatomical shape minimize
skin damage and pressure point. Regularly
replacing with binasal prongs additionally
ensures regeneration of the skin.
Binasale Prongs
Our prongs are available in seven different
sizes and are made of high-quality silicone.
The specially anatomically optimized shape
minimizes skin damage and pressure points.
Regularly replacing with our nasal masks
additionally ensures regeneration of the skin.
Measuring tape
The measuring tape assists in the size selection
of prongs, masks and bonnets. The optimal fit
has a direct effect on the quality of the nCPAP
therapy.
Giving neonates a future
Bonnets for single-use
The bonnet is the basis for the application of the entire nCPAP system since it ensures the necessary
stability. The medin bonnets are made of biocompatible microfibers and are individually packaged
and available in eight sizes. The particularly soft and elastic material protects the head without
deforming it. The fixation bands for prongs and masks attach anywhere to the bonnet and can thus
be individually positioned.
The Medijet nCPAP generator and the Miniflow nCPAP interface includes a foam cushion to reduce
tension that may be caused by the position of the breathing circuit.
Microfibers ensure a high degree of wear comfort
Color-coding enables easy size selection
Secure and stable fixation of the nCPAP interface
Manufacturer:
medin Medical Innovations GmbH
Adam-Geisler-Strasse 1, Germany
+49 8142 448 46-0
info@medin-medical.com
www.medin-medical.com
Rev00 – 2018-01-19 Specifications are subject to change without notice. Some features are options. Not all features are available in all markets. For all proprie-
tary trademarks (®) and third-party trademarks (§) used by medin Medical Innovations GmbH see www.medin-medical.com/trademarks.
© 2018 medin Medical Innovations GmbH. All rights reserved.