TC Troubleshoot Guide B11 Ed01
TC Troubleshoot Guide B11 Ed01
TIMIŞOARA
                                                                                                                 Originator
                                                                                                                                              TC Troubleshooting Guide Release B11
                                                                                                                  TC Team
PREDISTRIBUTION:
                                                                                                        ABSTRACT
                                                                                                        This document provides the operational workarounds, which can be applied by the Alcatel-
                                                                                                        Lucent teams on TC B11 from the first version.
                                                                                                                                                     Approvals
                                                                                                          Name               A.Negrescu
                                                                                                          App.              DPM/TC/B11
                                                                                                        HISTORY
                                                                                                        Ed. 01 Proposal 01   16/10/2008      First proposal
                                                                                                        Ed. 01 Proposal 02   23/11/2008      Second proposal
                                                                                                                                             Update: 3.4;3.5 paragraph
                                                                                                                                             New paragraph added: 2.1
                                                                                                        Ed. 01 Proposal 03   23/11/2009      Third proposal
                                                                                                                                             New paragraph added: 1.1; 1.2; 1.3;
                                                                                                                                             3.3; 3.4; 3.5; 4.2; 4.3; 4.4; 4.6; 5.2;
                                                                                                                                             5.4; 5.5; 5.6; 5.7
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
                                                                                                        SCOPE ........................................................................................................................................................4
                                                                                                        1     BASIC PROCEDURES .......................................................................................................................5
                                                                                                               1.1 Not possible to connect with terminal using MMI to an XB Board.............................................5
                                                                                                               1.2 [TCIL]After MT120 NB software activation, return to factory software and flash corruption .....6
                                                                                                        2     OMC/TC COMMUNICATION ..............................................................................................................7
                                                                                                               2.1 What to do in case of message “SNMP error during TC declaration –couldn’t obtain all
                                                                                                        needed information from TC board” ............................................................................................................7
                                                                                                        3     TCIF Administration.............................................................................................................................8
                                                                                                               3.1 Can not read IPTC2 registers because of "SIGALRM received during IOCTL segmentation
                                                                                                        fault"……… ..................................................................................................................................................8
                                                                                                               3.2 The IP board crashed after a call. .............................................................................................9
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
SCOPE
                                                                                                        The aim of this document is to provide hints and workarounds to operator using the B11 TC.
                                                                                                        This document is restricted for ALCATEL-LUCENT intern usage, notably for ALCATEL-
                                                                                                        LUCENT personnel providing on site support at customer premises.
                                                                                                        The chapters BASIC PROCEDURES and the TC ADMNISTRATION are the stable basic first
                                                                                                        aids, the other chapters are supposed to be updated each time new problems will occur.
                                                                                                        Reference FR
                                                                                                        None
                                                                                                        Problem description
                                                                                                        The connection to the xB board is established from TC-NEM using MMI. A cross cable is used to
                                                                                                        connect the PC on which the TC-NEM is installed, to the xB board on the Ethernet port. For some
                                                                                                        boards the connection is possible but for the some others not
                                                                                                        The problem is generated by the facts that the XB boards have the IP addresses in different networks
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
Corrective action
                                                                                                         On the debug trace of the board tape “Enter” and then “ifconfig”. The answer of the board will be like
                                                                                                        the following one :
                                                                                                        “lo0: flags=48049<UP,LOOPBACK,RUNNING,MULTICAST,INET_UP> mtu 1536
                                                                                                                 inet 127.0.0.1 netmask 0xff000000
                                                                                                        qefcc0: flags=78043<UP,BROADCAST,RUNNING,MULTICAST,NOTRAILERS,INET_UP> mtu 1500
                                                                                                                 inet 10.0.0.201 netmask 0xffffff00 broadcast 10.0.0.255
                                                                                                                 ether 00:c0:be:94:00:52
                                                                                                        value = 0 = 0x0”
                                                                                                        If the inet is 10.0.0.201 then configuration for the PC running TC-NEM: 10.0.0.202, case in which the
                                                                                                        board has the IP: 10.0.0.201. The mask remains the same.
                                                                                                        And so on if the inet is different, the Ip of the computer and the IP of the board in the TC-NEM window,
                                                                                                        should be set up accordingly
                                                                                                        Problem solved
                                                                                                        Not Applicable
                                                                                                        Reference FR
                                                                                                        3BKA37FBR260852
                                                                                                        Problem description
                                                                                                        Sometimes the NPSA gets corrupted and the board restarts in loop.
                                                                                                        Corrective action
                                                                                                        I.) Boot Selector Upgrade (the newest is MT120xB_BootSel_0203030)
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
Prerequisites:
                                                                                                        1. Connect the RS232 cable to the "Flash unprotect cable" and plug it in the debug connector of the
                                                                                                        MT120 xB board.
                                                                                                           [ PC --> Serial RS232 cable ---> "Flash unprotect cable" ---> MT120 xB board ]
                                                                                                           The "Flash unprotect cable" has the lever set so, that the access to the Flash of the MT120 xB board
                                                                                                        is unprotected.
                                                                                                        3. When you see a countdown (Boot will continue in 2, 1, ...) on the debug trace press "Enter". You will
                                                                                                        enter the command line interface, which allows you to type commands.
4. Write:
dlf "BOOT"
                                                                                                            Press "Enter".
                                                                                                            When you see "Please send file...", press on the Red arrow in DTerm and select the desired ".fh2"
                                                                                                        file. You will see the file being uploaded to the board.
5. Check that the transfer has been successfully performed, when you see on the screen:
value = 0 = 0x0
6. Press "CTRL"+x .The board will reboot with the Boot Selector updated.
Perform steps from 2 to 6 for all MT120 xB boards you want to update.
                                                                                                        Problem solved
                                                                                                        Not Applicable
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
2 OMC/TC COMMUNICATION
                                                                                                        Reference FR
                                                                                                        None
                                                                                                        Problem description
                                                                                                        The communication between OMC-R and TC is broken. This problem could appear if the networks
                                                                                                        where the OMC and TC are not communicating, if some preliminary configurations were not done on TC
                                                                                                        or if an OMC problem.
                                                                                                        Corrective action
                                                                                                        From the OMC terminal ping the active TCIF.
                                                                                                          - If no answer check if the networks are compatible
                                                                                                        Using a putty connect to active TCIF:
                                                                                                          - Check if the heartbeat and oaed process are running
                                                                                                        Using the TC-NEM connected to the distant IP of the TC check:
                                                                                                          - The BSC declared on OMC as associated to TC, exists in TCIF database (Rack config window)
                                                                                                          - The hostid of the OMC-R is declared on TCIF and it is associated to the right BSC (BSC Host Ids
                                                                                                              window)
                                                                                                          From the OMC-R terminal as axadmin user check if on TC side there are default passwords:
                                                                                                           axadmin@host$cd /usr/sfw/bin
                                                                                                           axadmin@host$./ snmpget -v 3 -u omc3 -l Authpriv -x DES -X privomc3 -a MD5 -A authomc3
                                                                                                          <TC_floating_ip_address> 1.3.6.1.4.1.637.70.6.1.3.1.5.0
                                                                                                         Normally the TC should answer with rack number. If the TC answers then is an OMC-R problem. Else
                                                                                                        check the TC configuration.
                                                                                                        To reset the passwords on the TCIFI boards, so that the communication with OMC-R can be established
                                                                                                        the following workaround has to be performed:
TCIF in slot 0: assure that the process are stopped (heartbeat, oaed, saed, hsid)
TCIF in slot 1 : assure that the process are stopped (heartbeat, oaed, saed, hsid)
                                                                                                               /optX/heartbeat-2.1.2/init.d/heartbeat stop
                                                                                                        where “X” is 0 or 1 depending where all processes are started from.
                                                                                                        This command stops the heartbeat process. Check that also oaed, saed, hsid are stopped.
                                                                                                                cd /mnt/flash
                                                                                                                ls –a
                                                                                                                rm –Rf .net-snmp
                                                                                                                reboot
After this has been done on both boards, declare the TC in OMC-R.
                                                                                                        Problem solved
                                                                                                        Not Applicable
3 TCIF Administration
                                                                                                        3.1 Can not read IPTC2 registers because of "SIGALRM received during IOCTL
                                                                                                           segmentation fault".
                                                                                                        Reference FR
                                                                                                        3BKA37FBR252568
                                                                                                        Problem description
                                                                                                        The error "SIGALRM received during IOCTL segmentation fault" is reported when FIBd table is reading
                                                                                                        more then 3 times.
                                                                                                        Corrective action
                                                                                                        Reboot TCIF boards.
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        Reference FR
                                                                                                        3BKA37FBR238106
                                                                                                        Problem description
                                                                                                        The read of internal tables on the JGIPTC board displays out of range value
                                                                                                        The IPFWD driver freezes sometimes when TCIF software tries to access it (read/write).
                                                                                                        Corrective action
                                                                                                        Workaround: reboot TCIF.
                                                                                                        Problem solved
                                                                                                        Not applicable
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
                                                                                                        Reference CR
                                                                                                        3BKA20CBR261193/3BKA20CBR261194
                                                                                                        Problem description
                                                                                                        In the IP transport to simplify the configuration of firewalls.
                                                                                                        Corrective action
                                                                                                        Port range changed as specified in the CR Document.
                                                                                                        M2UA_SCTP_PORT_TC (STCP port used for M2UA protocol- signalisation to/from A interface),
                                                                                                        TC side
                                                                                                          minim : 52592
                                                                                                          maxim : 52615
                                                                                                          step size = 1
                                                                                                        IPTCH_UDP_PORT_TC_MUX (UDP ports of IPTCH link used on TC side (for MUXTRAUP and
                                                                                                        TRAUP protocols))
                                                                                                          minim : 54528
                                                                                                          maxim : 54575
                                                                                                          minim : 52528
                                                                                                          maxim: 52577
                                                                                                        Careful! In TC_NEM/ Rack Config tab when the BSCs are declared at tcsl_Port _TC_Side is
                                                                                                        safely to use the ports from 4 to 4 step. (eg : for BSC1 : TC_Port_Side 52528, BSC2 :
                                                                                                        TC_Port_Side 52532, …..).
                                                                                                        Those ports should be the same as in BSC build.
                                                                                                        Problem solved
                                                                                                        Not applicable
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
                                                                                                        Reference FR
                                                                                                        3BKA20FBR270673
                                                                                                        Problem description
                                                                                                        Is needed to have server port 5555 and client port 1025..65535 unlocked on client live network in order
                                                                                                        to take traces from TCIF.
                                                                                                        Corrective action
                                                                                                        Check that the ping between the Windows PC (on which the traces are saved) and TCIF it’s working.
                                                                                                        TCIF boards are installed in one TC G2.5 rack: one is active and the other one is standby.
                                                                                                        The traces are saved on the Windows XP PC.
                                                                                                        The traces on TCIF board are possible to be taken, using the current method, beginning with the
                                                                                                        TCIFAZ01Q software version.
                                                                                                        The logging_client_AZab software package is available on site (ab is the version).
First steps
                                                                                                        The local serial connection from the PC to the TCIF board (RS connector) can be used.
                                                                                                        Instead of using the local serial connection, it is possible also to perform the following commands
                                                                                                        (chapters 3, 4 and 5) on a remote SSH (PUTTY) connection on each TCIF board.
                                                                                                        Starting with the version Logging_client_AZ02F, it is recommended to use a remote PUTTY connection
                                                                                                        on each TCIF board. For remote SSH connection on PUTTY, use HDEV user and cit_ln password.
                                                                                                        For maintenance operations, change to root user, using the su command (the password for root is tcif).
                                                                                                                            # LOGGING PARAMETERS
                                                                                                                            ####################
                                                                                                                            # oaed section
                                                                                                                            OAED_LOGGING_ENABLED=0
                                                                                                                            OAED_LOG_SERVER_HOST=192.168.89.17
                                                                                                                            OAED_LOG_SERVER_PORT=9876
                                                                                                                            OAED_ALLOW_TRACE_LEVEL=0
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
                                                                                                                            # hsid section
                                                                                                                            HSID_LOGGING_ENABLED=0
                                                                                                                            HSID_LOG_SERVER_HOST=192.168.89.17
                                                                                                                            HSID_LOG_SERVER_PORT=9876
                                                                                                                            HSID_ALLOW_TRACE_LEVEL=0
                                                                                                                            # saed section
                                                                                                                            SAED_LOGGING_ENABLED=0
                                                                                                                            SAED_LOG_SERVER_HOST=192.168.89.17
                                                                                                                            SAED_LOG_SERVER_PORT=9876
                                                                                                                            SAED_ALLOW_TRACE_LEVEL=0
                                                                                                                            # qmuxd section
                                                                                                                            QMUXD_LOGGING_ENABLED=0
                                                                                                                            QMUXD_LOG_SERVER_HOST=192.168.140.17
                                                                                                                            QMUXD_LOG_SERVER_PORT=9876
                                                                                                                            QMUXD_ALLOW_TRACE_LEVEL=0
                                                                                                        Inside this file, set the value 1, instead of the value 0, for each daemon on which will be activated the
                                                                                                        LOG file.
                                                                                                                               cd /opt/tcifR-1.1/share/tcif
                                                                                                                               vi logging.conf
                                                                                                                               daemon_LOGGING_ENABLED=1
                                                                                                        The daemon can be oaed, hsid , saed or qmuxd. The most important trace is the oaed trace, that means
                                                                                                        in the logging.conf file will be set:
                                                                                                        OAED_LOGGING_ENABLED=1
                                                                                                        In this case a low level of trace will be available, level which should be used when a full TC G2.5 rack
                                                                                                        with 48 MT120 boards is used.
                                                                                                        daemon_ALLOW_TRACE_LEVEL =1
                                                                                                        In this case the high level of traces will be available.
                                                                                                        On each TCIF board is present the file logd process in the directory /opt/tcifR-1.1/init.d
                                                                                                        This process must be started.
                                                                                                                                 cd /opt/tcifR-1.1/init.d
                                                                                                                                 ./logd start
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
                                                                                                                                 cd /opt/tcifR-1.1/init.d
                                                                                                                                 ./logd status
                                                                                                        In order to avoid to start manually the logd process, in case the TCIF board restarts, it is necessary to
                                                                                                        change the file 99heartbeat.
                                                                                                                                 cd /opt/tcif-scripts-1.1/etc/rc.d
                                                                                                                                 vi 99heartbeat
                                                                                                        Uncomment the line:
                                                                                                                                 #su root -c "/opt${instance}/tcif?-1.1/init.d/logd start"
                                                                                                        Important: Go further only after the heartbeat is stopped on both TCIF boards. Between the
                                                                                                        stopping of the heartbeat on one TCIF board and the stopping of the heartbeat on the other TCIF,
                                                                                                        there must be no more than 1 minute.
/opt/heartbeat-2.1.2/init.d/heartbeat stop
                                                                                                        When the heartbeat process is stopped, there will be no other process running (hsid, saed, oaed,
                                                                                                        mmirelay, qmux_forwarder, in.tftpd are automatically stopped). Check this, on each TCIF board, with:
All the other processes will be started automatically, when the heartbeat process is started.
Check that the ping between the Windows PC (on which the traces are saved) and TCIF its working.
                                                                                                        Start the command prompt from Windows: Start/run/cmd, go to the directory where the logging client
                                                                                                        was extracted (e.g. C:/logging_client_AX42A) and execute the command:
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
where: IP_ETH1_TCIF1 and IP_ETH1_TCIF2 are he IP addresses of the two TCIF boards.
                                                                                                              The traces will be saved in the default path .\Traces\(Board0 | Board1) – normally this two
                                                                                                        directories exist after unpacking the client (e.g. C:/logging_client_02R/Traces/Board0). In order to save
                                                                                                        the traces to a different location, the run_logging_client.bat file must be modified and the directory
                                                                                                        Traces plus the two sub-directories must be created manually.
Final checks
                                                                                                        To stop the traces it does not suffice to stop the logd process. The modified values in the
                                                                                                        logging.conf file must be reset to 0. After this has been done, the heartbeat process has to be stopped
                                                                                                        and restarted.
                                                                                                        Note
                                                                                                        It is recommended to take only the oaed traces, because of TCIF and network overload.
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        Reference FR
                                                                                                        3BKA20FBR251609
                                                                                                        Problem description
                                                                                                        TC G2.5 IP (Package 2) is not working with only one TCIF board or it is very slow.
                                                                                                        Not possible to declare BSC at TC NEM IP connection.
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        3.6 [B11-TLO-FR] IP mode : after performing the 3 flashes and reboot the TCIF,
                                                                                                           the board cannot restart normally due to "Loading STM1" frozen on Serial
                                                                                                           link.
                                                                                                        Reference FR
                                                                                                        3BKA37FBR249426
                                                                                                        Problem description
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
                                                                                                        The problem is coming from an old version of the EPLD JGTCBM "e" instead of "f". New ICS03 TCIFI is
                                                                                                        requested for the TCIFI HW SUB DR4.
                                                                                                        Corrective action
                                                                                                        An upgrade procedure for STM-1      board (TestOBC binary file, JGTCM):
                                                                                                                                                    JGTCBM EPLD load
                                                                                                        It is recommended to use a remote PUTTY connection on each TCIFI board. For remote SSH
                                                                                                        connection on PUTTY, use HDEV user and cit_ln password.
                                                                                                        For maintenance operations, change to root user, using the su command (the password for root is tcif).
                                                                                                        Take care, the files for the STM-1 board are already on the TCIF.
                                                                                                        The STM-1 board needs to be on the TCIF board.
If the result is different than “f”, the STM-1 board needs to be upgraded.
Check that all processes are stopped (hsid, oaed, saed, tclogger):
                                                                                                            -   insmod /lib/modules/2.6.10_mvlcge401-8560ads/jts10_jtag_drv.ko
                                                                                                            -   cat /proc/devices|grep jtag
The command will give the “major” for the driver jts10_jtag_drv <MAJOR> jtag_drv
                                                                                                                Report:
                                                                                                                            Total Byte Number : 452
                                                                                                                            Number of Test: 232
                                                                                                                            Number of Error: 0
                                                                                                                            Number of Success: 232
                                                                                                                Load OK!!!
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
If the result of the Firecron_infra_lp1.bvf is Load Failed!!!, you should not try to load EPLD.
Reboot the TCIFI boards and after the TCIF is up and running, check the version of the STM-1 board:
                                                                                                        cd /opt/tcifR-1.1/bin
                                                                                                        TestObcDriver.test Test_OBC_Drv test_ReadStm1Version
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        Reference FR
                                                                                                        None
                                                                                                        Problem description
                                                                                                        The problem is coming from the soft version of the IPTC.
                                                                                                        It is recommended to use a remote PUTTY connection on each TCIFI board. For remote SSH
                                                                                                        connection on PUTTY, use HDEV user and cit_ln password.
                                                                                                        For maintenance operations, change to root user, using the su command (the password for root is tcif).
Before starting the upgraded the board check the version of the IPTC:
0x20000000
                                                                                                        If the result is :
                                                                                                        „Register at address 0x20000000 has value: hexa: 0x3000005 (decimal: 50331653)“
If the value indicates a version older than 0x3000005, the upgrade is necessary.
                                                                                                             /opt/heartbeat-2.1.2/init.d/heartbeat stop
                                                                                                            /opt/tcifR-1.1/init.d /logd stop
ps –eaf
                                                                                                        The command will give the major for the driver jts10_jtag_drv
                                                                                                        <MAJOR> jtag_drv
                                                                                                         If cannot be change the rights and the owner of the three files (*.bvf) from /mnt/nfs path than copy them
                                                                                                        in /tmp.
                                                                                                        # cd /tmp
                                                                                                        #jts10_jtag_loader infra_jaxip.bvf
                                                                                                        Report:
                                                                                                            -> Total Byte Number: 1951
                                                                                                            -> Number of Test: 518
                                                                                                            -> Number of Error: 0
                                                                                                            -> Number of Success: 518
                                                                                                        Load OK !!!!
If the result of the file infra_jaxip.bvf is Load Failed !!!!, you should not try to load the FPGA.
# jts10_jtag_loader sfl_altera.bvf
                                                                                                        Report:
                                                                                                            -> Total Byte Number: 6425747
                                                                                                            -> Number of Test: 3212847
                                                                                                            -> Number of Error: 0
                                                                                                            -> Number of Success: 3212847
                                                                                                        Load OK !!!!
-#jts10_jtag_loader jgiptc.bvf
                                                                                                        Report:
                                                                                                            -> Total Byte Number: 41194355
                                                                                                            -> Number of Test: 20448929
                                                                                                            -> Number of Error: 0
                                                                                                        On the both TCIFI boards the all processes are still stopped.
                                                                                                        Only on the Master TCIFI board start the heartbeat process:
/opt/heartbeat-2.1.2/init.d/heartbeat start
                                                                                                        From TC-NEM (trough IP connection – introduce the IP of the Master board) perform “lock” on Stand-by
                                                                                                        board.
                                                                                                        The blue led is lighting on the Stand-by board. In TC-NEM the Stand-by board became red.
                                                                                                        Then perform “unlock” on Stand-by board.
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
                                                                                                        Also for the other TCIFI board, from TC-NEM perform “lock” on Master board.
                                                                                                        The blue led is lighting on the newly Stand-by board (a takeover occurred also).
                                                                                                        In TC-NEM the Stand-by board became red.
                                                                                                        Then perform “unlock” on Stand-by board.
                                                                                                        Please check if the all processes (oaed, saed, hsid) are up and running on both TCIFI from putty
                                                                                                        connection:
ps –eaf
                                                                                                        Check that the upgrade was made by giving the command on both TCIFI boards:
                                                                                                        /opt/tcifR-1.1/bin/ipfwutil Test_IPFW_Drv test_readCustomRegister
If the version is the upgraded one, then the upgrade was done successfully.
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        Reference FR
                                                                                                        None
                                                                                                        Problem description
                                                                                                        To verify which board is clock master.
                                                                                                        #cd /opt/tcifR-1.1/bin
                                                                                                        #./hsiutil Test_HSI_Drv test_GetClockRef 2>/dev/null
                                                                                                        In the output of the execution you will have “Clock reference id xx” , where xx is the MT120 board from
                                                                                                        which the TCIF has take the clock. The numbering is done from left to right and from bottom to top
                                                                                                        beginning from 0.
Example:
                                                                                                        “Running 1 testClock reference is 10” the MT120 board has HSI number 10 (TEI74)
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
                                                                                                        Problem solved
                                                                                                        Not applicable
4 MT120 Administration
                                                                                                        4.1 [Val-Vz]- TC-AUDIT-NEEDED sent in loop after switchover TCIF from slot#1 to
                                                                                                            slot#0.
                                                                                                        Reference FR
                                                                                                        3BKA37FBR254772
                                                                                                        Problem description
                                                                                                        After new switchover from slot#1 to slot#0, TCSL and TC-OM was established even if TC-AUDIT
                                                                                                        scenario was successfully, and TC-OM established, TC continue to sent TC-AUDIT-NEEDED.
                                                                                                        Corrective action
                                                                                                        Plug out/in the board
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        Reference FR
                                                                                                        3BKA37FBR259302, 3BKA37FBR258710, 3BKA20FBR255919
                                                                                                        Problem description
                                                                                                        TCIF 1 (Slot 0) is up, but most of the MT120 Legacy boards from the rack are connected to TCIF 2 (Slot
                                                                                                        1), after TCIF takeover, or after changing the software management mode from TCIL to HSI, with the
                                                                                                        result that MT120 boards are missing from TC-NEM’s “Rack Overview” when connected trough IP.
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
                                                                                                        Corrective action
                                                                                                        Connect locally on the missing boards from TC-NEM's "Rack Overview" and perform a restart, or,
                                                                                                        perform a reset of the active TCIF.
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        4.3 [B11-TLO-FR] TDM mode: During MT120 software download from AZ03C to
                                                                                                            AZ03D the TC configuration is lost.
                                                                                                        Reference FR
                                                                                                        3BKA20FBR262363
                                                                                                        Problem description
                                                                                                        Part of the persistent FLASH memory is overwritten, leading either to loose of the configuration or fall-
                                                                                                        back to origin software. No traffic possible.
                                                                                                        Corrective action
                                                                                                        The problem was corrected for the software with a dimension of 476 blocks.
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        4.4 TC is reporting incorrect values for the capability of MT120 in case of Legacy
                                                                                                            (0) and WB(2) boards.
                                                                                                        Reference FR
                                                                                                        3BKA37FBR273364
                                                                                                        Corrective action
                                                                                                        The correction was made accordantly with:
                                                                                                        - 00000001(1 in dec) - for Legacy (TFO_AMR_NB)
                                                                                                        - 00000001(1 in dec) - for xB_NB (TFO_AMR_NB)
                                                                                                        - 00000011(3 in dec) - for xB_WB (TFO_AMR_NB and TFO_AMR_WB)
                                                                                                        Problem solved
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
Not applicable
                                                                                                        Reference FR
                                                                                                        None
                                                                                                        Problem description
                                                                                                        There are two possibilities to take MT debug traces, using Tera Term or Dterm applications.
                                                                                                        In order to take the debug traces a "TC NEM" cable is needed but not plugged in MMI position but in
                                                                                                        debug for both Legacy and XB board.
                                                                                                        Corrective action
                                                                                                        How to take debug traces using Tera Term aplication:
                                                                                                        - The cable connected between MMI of the board and the COMx of the computer
                                                                                                        - Open the Tera Term and select the serial connection and the COMx
                                                                                                        - From terminal menu select "Setup" and the "Serial port"
                                                                                                        - Select the settings :
                                                                                                            - Port:             COMx
                                                                                                            - Data :            8 bit
                                                                                                            - Parity :          none
                                                                                                            - Stop:             1 bit
                                                                                                            - Flow control : none
                                                                                                            - Transmit delay: 0
                                                                                                            If the board is a Legacy one selected Baudrate is 38400
                                                                                                            If the board is a XB one , the the Baud rate should be 115200
                                                                                                            To save the debug traces select on the Tera term window the “File ” and “Log ” options and give a
                                                                                                            name and a place were the traces to be stored
                                                                                                           - The cable connected between MMI of the board and the COMx of the computer
                                                                                                           - Open the Dterm window
                                                                                                           - From the terminal menu select "Settings" , then "Itf. Communication Settings"
                                                                                                           - Select the following settings:
                                                                                                               - Port:            COMx
                                                                                                               - Data bits :      8 bit
                                                                                                               - Parity :         none
                                                                                                               - Stop bits:       1 bit
                                                                                                               - Protocol:        none
                                                                                                        After the settings done the push the RS232 button from the menu.
                                                                                                        To save the debug traces select on the debug window the “Capture ” button, give a name and a place
                                                                                                        were the traces to be stored
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        4.6 [HSI][xB] When performing MT120 SWR trough TCIF it is possible that a
                                                                                                           MT120 xB board becomes misaligned (red) in TC-NEM's "Rack Overwiev"
                                                                                                           with the "Reason: File List Report Failure"
                                                                                                        Reference FR
                                                                                                        3BKA37FBR269637
                                                                                                        Problem description
                                                                                                        After activation of a new software when performing MT120 SWR trough TCIF an MT120 xB board to
                                                                                                        become misaligned (red) in TC-NEM's "Rack Overwiev" with the "Reason: File List Report Failure".
                                                                                                        Corrective action
                                                                                                        Possible workarounds:
                                                                                                        1. Connect locally to the misaligned (red) MT120 board and activate the new software version, so that it
                                                                                                        becomes inline with the software on the other boards.
                                                                                                        2. Perform "Reject MT120 Software" from TC-NEM's "Download" window and start the SWR again.
                                                                                                        3. Associate the misaligned MT120 board to a dummy BSC and start the SWR again.
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        Reference FR
                                                                                                        3BKA37FBR262620
                                                                                                        Problem description
                                                                                                        Sometimes after performing "Write Conf" or Reset or similar actions that require a MT120 board reset, it
                                                                                                        was observed that one board is appearing and disappearing continuously in TC-NEM.
                                                                                                        Corrective action
                                                                                                        Workaround:
                                                                                                        In order to make the MT120 board to be stable in TC-NEM several actions were performed:
                                                                                                        - Restart from TC-NEM => no success
                                                                                                        - Reset from TC-NEM => no success
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        Reference FR
                                                                                                        None
                                                                                                        Problem description
                                                                                                        In case of SW corruption or the package size of the SW is too big than it is necessary to put back the on
                                                                                                        the board the factory software.
                                                                                                        Corrective action
                                                                                                           - Open the Dterm window
                                                                                                           - From the terminal menu select "Settings" , then "Itf. Communication Settings"
                                                                                                           - Select the following settings:
                                                                                                               - Port:            COMx
                                                                                                               - Data bits :      8 bit
                                                                                                               - Parity :         none
                                                                                                               - Stop bits:       1 bit
                                                                                                               - Protocol:        none
CMDS>> re h
                                                                                                        else do again:
                                                                                                           -Unplug/Plug the board in slot
                                                                                                           - Press in continue S key till than appears on the screen “List of task used by DKOS”
                                                                                                           - Press <Ctrl><U> keys
                                                                                                            -Write when CMDS>> prompt appears:
                                                                                                             flrz 400000 30
                                                                                                        Problem solved
                                                                                                        Not applicable
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
5 TC-NEM Administration
                                                                                                        5.1 TC NEM installed on a Windows Vista PC rejects the Local setting although a
                                                                                                            local connection is set between TC NEM and TCIF
                                                                                                        Reference FR
                                                                                                        3BKA37FBR254402
                                                                                                        Problem description
                                                                                                        On the PC with Windows Vista, during TCIF IP Configuration phase, the TC NEM is opened and the IP
                                                                                                        address is introduced and select Local, the settings are rejected with the following error/warning
                                                                                                        message: "Please change the IP Address or change to Remote!"
                                                                                                        Corrective action
                                                                                                        If Remote setting is selected the TC-NEM is connected to the TCIF
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        5.2 Sometimes one or more processes from TC-NEM remain active in Windows
                                                                                                            and need to be close manually from Task Manager, in order to be able to
                                                                                                            restart TC-NEM again.
                                                                                                        Reference FR
                                                                                                        None
                                                                                                        Problem description
                                                                                                        One or more processes (called for example TC32Container or TC32TCIF) from TC-NEM remain active
                                                                                                        in and need to be close manually from Task Manager, in order to be able to restart TC-NEM again, after
                                                                                                        the application has encountered a problem and might have suffered a crash.
                                                                                                         ED01 RELEASE01                                                          TC Troubleshooting Guide B11 Release
                                                                                                                                                        Site             3BK 29873 MAAA PWZZA             24/27
                                                                                                        Corrective action
                                                                                                        Close manually from Task Manager the hanging processes.
                                                                                                        Problem solved
                                                                                                        Not applicable
5.3 The TCIF window is not opened when connect the TC NEM to TCIF
                                                                                                        Reference FR
                                                                                                        3BKA37FBR254401
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
                                                                                                        Problem description
                                                                                                        On the PC with Windows Vista, during TCIF IP Configuration phase, the TC NEM is opened using the
                                                                                                        active TCIF IP. The connection is established but the TCIF window is not opened, so no action can be
                                                                                                        performed from TC-NEM.
                                                                                                        Corrective action
                                                                                                        Before starting the TC NEM, launch the following application files from C:\ProgramFiles\Alcatel-
                                                                                                        Lucent\TC-NEM
                                                                                                        TC32Controller.exe
                                                                                                        TC32OTP.exe
                                                                                                        TC32OTPIP.exe
                                                                                                        TC32TCIF.exe
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        5.4 Changing the Management Mode for a MT120 Legacy or MT120 xB board
                                                                                                           from HSI to TCIL or TCIL to HSI generates a timeout
                                                                                                        Reference FR
                                                                                                        None
                                                                                                        Problem description
                                                                                                        On the serial connection when changing the mode from HSI to TCIL for a MT board the message
                                                                                                        “Timeout, request not answered” can be seen in TC-NEM. This message is normal, because the change
                                                                                                        in the management mode generates a restart of the board, time in which TC-NEM is not receiving any
                                                                                                        information from the board.
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        5.5 Sometimes, in TC-NEM it is not possible to see any alarm about MT boards
                                                                                                            after a request
                                                                                                        Reference FR
                                                                                                        3BKA37FBR252775
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
                                                                                                        Problem description
                                                                                                        TC-NEM is connected to the TCIF board, through IP.
                                                                                                        Several actions were performed on MT boards: reset, restart.
                                                                                                        But when triggering enable_fault_indication on one/all boards, nothing happens, no alarm is seen, no
                                                                                                        colour in menu window on the MT boards. After a few seconds a message is written in the bottom of the
                                                                                                        window: "Timeout, request not answered".
                                                                                                        If a command for checking the DSP status is triggered, again no answer.
                                                                                                        It seems the MMI process is freezed. But the MMIrelay, oaed and other processes are present and
                                                                                                        running on TCIF board..
                                                                                                        Corrective action
                                                                                                        Close/open again the TC-NEM.
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        Reference FR
                                                                                                        None
                                                                                                        Problem description
                                                                                                        Helps the programmer to follow the steps made by the application.
                                                                                                        Corrective action
                                                                                                        In order to save the TC-NEM logs the following steps have to be performed:
                                                                                                        - connect TC-NEM
                                                                                                        - in TC-NEM menu select File - Logfile- New- enter the desired name of the log and the place to be
                                                                                                        stored
                                                                                                        At the end of the test
                                                                                                        - in TC-NEM menu select File- Logfile – Close
                                                                                                        Problem solved
                                                                                                        Not applicable
                                                                                                        ED01 RELEASE01                                                           TC Troubleshooting Guide B11 Release
                                                                                                                                                       Site            3BK 29873 MAAA PWZZA              26/27
                                                                                                        5.7 Sometimes when performing MT120 replacement with the Wizard provided
                                                                                                           by TC-NEM it is possible that the application remains hanging.
                                                                                                        Reference FR
                                                                                                        3BKA37FBR269891
                                                                                                        Problem description
                                                                                                        TC-NEM remains hanging when performing MT120 replacement.
                                                                                                        Corrective action
                                                                                                        To restart TC-NEM, all related processes must be stopped manually from Window's Task Manger
All rights reserved. Passing on and copying of this
                                                      document, use and communication of its contents
Processes window.
                                                                                                        Problem solved
                                                                                                        Not applicable