                                                                                                 i06194869
 Diagnostic Trouble Codes
 SMCS - 1900
 Cross-Reference Information for Diagnostic Codes
 Table 1 is a list of the diagnostic codes for the engine. The diagnostic codes are cross-referenced with
 the appropriate procedure that can be used to troubleshoot the code.
 Further explanations of diagnostic codes are explained after Table 1.
                                                   Table 1
     Cross-Reference from CID-FMI Code on Cat Data Link to Troubleshooting Procedure
   Code                      Description                                    Procedure
                                                             Troubleshooting, "Speed Control (PWM) -
   91-08               Throttle Position Invalid
                                                                               Test"
                                                             Troubleshooting, "Speed Control (PWM) -
   91-10            Throttle signal rate of change
                                                                               Test"
  100-01              Low Oil Pressure Warning                Troubleshooting, "Oil Pressure Is Low"
                                                              Troubleshooting, "Sensor Signal (Analog,
  100-03              Oil Pressure voltage high
                                                                          Active) - Test"
                                                              Troubleshooting, "Sensor Signal (Analog,
  100-04               Oil Pressure voltage low
                                                                          Active) - Test"
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 06-06-2017
Advanced Full Text Search - UENR0986 - 3412 Generator Set                                Página 2 de 6
  102-00            Excessive Boost Pressure            Troubleshooting, "Boost Pressure Is High"
            Engine Intake Manifold #1 Pressure : Low -
  102-01                                               Troubleshooting, "Boost Pressure Is Low"
                         most severe (3)
               Engine Intake Manifold #1 Pressure :      Troubleshooting, "Sensor Signal (Analog,
  102-03
                     Voltage Above Normal                            Active) - Test"
               Engine Intake Manifold #1 Pressure :      Troubleshooting, "Sensor Signal (Analog,
  102-04
                     Voltage Below Normal                            Active) - Test"
             Barometric Pressure : Low - most severe
  108-01                                                            The engine derates
                              (3)
               Barometric Pressure : Voltage Above       Troubleshooting, "Atmospheric Pressure -
  108-03
                            Normal                                        Test"
               Barometric Pressure : Voltage Below       Troubleshooting, "Atmospheric Pressure -
  108-04
                            Normal                                        Test"
                                                              Troubleshooting, "High Coolant
  110-00       High Coolant Temperature Warning
                                                                      Temperature"
                                                         Troubleshooting, "Coolant Temperature -
  110-03        Coolant Temperature voltage high
                                                                          Test"
                                                         Troubleshooting, "Coolant Temperature -
  110-04        Coolant Temperature voltage low
                                                                          Test"
  190-00           Engine Overspeed Warning               Troubleshooting, "Engine Overspeeds"
  190-08       Primary Engine Speed loss of signal        Troubleshooting, "Engine Speed - Test"
  190-10           Engine Speed rate of change            Troubleshooting, "Engine Speed - Test"
                                                            Troubleshooting, "ECM/Personality
  360-02      Check Customer or System Parameters
                                                                     Module - Test"
                                                            Troubleshooting, "ECM/Personality
  361-02            Personality Module Fault
                                                                     Module - Test"
              Engine Fuel Shutoff Valve #1 : Current
  632-05                                                  Troubleshooting, "Fuel Shutoff - Test"
                         Below Normal
              Engine Fuel Shutoff Valve #1 : Current
  632-06                                                  Troubleshooting, "Fuel Shutoff - Test"
                         Above Normal
               Engine Fuel Rack Actuator : Erratic,       Troubleshooting, "Fuel Rack Solenoid -
  638-02
                    Intermittent, or Incorrect                            Test"
            Engine Fuel Rack Actuator : Current Below     Troubleshooting, "Fuel Rack Solenoid -
  638-05
                            Normal                                        Test"
  638-06
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 06-06-2017
Advanced Full Text Search - UENR0986 - 3412 Generator Set                                 Página 3 de 6
            Engine Fuel Rack Actuator : Current Above       Troubleshooting, "Fuel Rack Solenoid -
                            Normal                                          Test"
   1210-    Engine Fuel Rack Position : Current Below      Troubleshooting, "Sensor Signal (Analog,
    05                      Normal                                     Active) - Test"
   1210-    Engine Fuel Rack Position : Current Above      Troubleshooting, "Sensor Signal (Analog,
    06                      Normal                                     Active) - Test"
   1210-          Engine Fuel Rack Position : Not          Troubleshooting, "Sensor Signal (Analog,
    07                Responding Properly                              Active) - Test"
   1210-    Engine Fuel Rack Position : Abnormal Rate      Troubleshooting, "Sensor Signal (Analog,
    10                     of Change                                   Active) - Test"
   3509-
    00
                        5 Volt Open Circuit                Troubleshooting, "Sensor Supply - Test"
   3510-
    00
   3509-
    01
                       5 Volt Short Circuit                Troubleshooting, "Sensor Supply - Test"
   3510-
    01
   3509-
    02
                        8 Volt Open Circuit                Troubleshooting, "Sensor Supply - Test"
   3510-
    02
   3509-
    03
                       8 Volt Short Circuit                Troubleshooting, "Sensor Supply - Test"
   3510-
    03
 Diagnostic Codes
 Diagnostic codes alert the operator that a problem in the electronic system has been detected.
 Diagnostic codes are also used by the service technician to identify the nature of the problem.
 Caterpillar Electronic Technician (ET) is a software program that is designed to run on a personal
 computer. The software can be used by the service technician in order to view the diagnostic code
 information for an ECM. Diagnostic codes may consist of the component identifier (CID), and the
 failure mode identifier (FMI).
 Component Identifier (CID) - The CID indicates the component that generated the code. For
 example, the CID number 1 identifies the fuel injector for the number one cylinder.
 Failure Mode Identifier (FMI) - The FMI indicates the type of failure. Refer to Table 2 for a
 complete list of the two-digit codes.
                    Table 2
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 06-06-2017
Advanced Full Text Search - UENR0986 - 3412 Generator Set                                   Página 4 de 6
  FMI                   Failure
  00      Data is above the normal range.
  01      Data is below the normal range.
  02      Incorrect signal
  03      Voltage is above the normal range.
  04      Voltage is below the normal range.
  05      Current is below the normal range.
  06      Current is above the normal range.
  08      Abnormal signal
  09      Abnormal update
  12      A device or a component failed.
  13      A component is out of calibration.
 Refer to Table 1 for a complete list of the diagnostic codes and the appropriate troubleshooting
 procedure.
 Illustration 1 is an example of the operating range of a sensor.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 06-06-2017
Advanced Full Text Search - UENR0986 - 3412 Generator Set                                                    Página 5 de 6
 Illustration 1                                                                                                 g01365757
 Example of the typical operating range of a sensor
 (1) This area represents the normal operating range of the engine parameter.
 (2) In these areas, the engine is operating in an unsafe operating range of the monitored parameter. An event code will be
 generated for the monitored parameter. The sensor circuit does not have an electronic problem.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 06-06-2017
Advanced Full Text Search - UENR0986 - 3412 Generator Set                                                       Página 6 de 6
 (3) In these areas, the signal from the sensor is outside of the operating range of the sensor. The sensor circuit has an
 electronic problem. A diagnostic code will be generated for the sensor circuit.
 Active Diagnostic Codes
 An active diagnostic code represents a problem with the electronic control system. Correct the
 problem as soon as possible.
 When the engine ECM generates an active diagnostic code, the "Active Alarm" indicator ("Engine
 Control Alarm Status" on Cat ET) is activated in order to alert the operator. If the condition that
 generated the code is momentary, the message disappears from the list of active diagnostic codes. The
 diagnostic code becomes logged.
 Logged Diagnostic Codes
 When the ECM generates a diagnostic code, the ECM logs the code in permanent memory. The ECM
 has an internal diagnostic clock. Each ECM will record the following information when a code is
 generated:
     • The hour of the first occurrence of the code
     • The hour of the last occurrence of the code
     • The number of occurrences of the code
 This information is a valuable indicator for troubleshooting intermittent problems.
 A code is cleared from memory when one of the following conditions occur:
     • The service technician manually clears the code.
     • The code does not recur for 100 hours.
     • A new code is logged and there are already ten codes in memory. In this case, the oldest code is
       cleared.
 Some diagnostic codes may be easily triggered. Some diagnostic codes may log occurrences that did
 not result in complaints. The most likely cause of an intermittent problem is a faulty connection or
 damaged wiring. The next likely cause is a component failure. The least likely cause is the failure of
 an electronic module. Diagnostic codes that are logged repeatedly may indicate a problem that needs
 special investigation.
 Note: Always clear logged diagnostic codes after investigating and correcting the problem which
 generated the code.