Diesel Powered
Generating Sets
1000 kW - 1340 kW 50 Hz
KTA50 Series Engines
Standard Genset Features
Single Source Responsibility Alternator PCC PowerCommand®
• Design, manufacturer and test of all • Brushless Group made machine Control System
components and accessories are • Close voltage regulation • PCC2100 Controller with
made by Cummins Power • Rotor and exciter impregnated with bar graph as standard
Generation and Cummins companies oil and acid resisting resin • Microprocessor control
International Integrity • 6 lead reconnectable • Integrates governor and voltage
• Assurance and strength of a • Exceptional short circuit capability regulation systems
worldwide, world class corporation • Low waveform distortion with non • Superior alternator and genset
Global Backing linear loads protection system
• 24-hoursparesandservicesupport– • Permanent magnet exciter • Accurate battery monitoring system
in 72 countries fitted as standard • Totally reliable and proven system
Single Source Warranty Ratings
• Complete genset covered by All kW Power ratings based on a 27°C
Cummins Power Generation ambient temperature reference. No
comprehensive warranty derating necessary up to 27°C
Packaged Self-Contained Units Chasis
• Units with built in antivibration Built-in anti-vibration system
systems with provision for base fuel Bonded rubber units fitted as standard
tank and other accessories eliminates need for rubber mats or
Cummins Engine spring mountings
• Heavy duty 4 cycle water cooled Cooling System
engine • 40°Ccoolingpackage(50°Coption)
Electronic governor control Ready Filled
• Every set comes filled with lube oil
and anti-freeze
50 Hz Ratings
Model Prime Standby Engine TA-Luft
Prime kW (kVA) kW (kVA) Model Compliance
C1400 D5 1000 (1250) 1120 (1400) KTA50G3 ––
C1400 D5E 1000 (1250) 1120 (1400) KTA50G7 2.0 g/nm³
C1675 D5 1120 (1400) 1340 (1675) KTA50G8 ––
A Single Source for all Power System Solutions
Specifications May Change Without Notice
Specifications
Generator Set Performance Generator Set Options
Voltage Regulation Waveform Engine
Maintains voltage output to within ±0.5%. Total harmonic distortion open circuit voltage Heavy duty air cleaner
At any power factor between 0.8 lagging and waveform in the order of 1.5%. Three-phase Coolant heater and thermostat
unity. balanced load in the order of 5.0%. Lead acid batteries, cable and fitted tray
At any variations from No load to Full load. Telephone Influence Factor Sump drain pump
At any variations from Cold to Hot. TIF better than 50. Oil and water drain taps
At speed droop variations up to 4.5%. THF to BS4999 Part 40 better than 2%. CE Compliance (guarding)
Frequency Regulation Alternator Temperature Rise Exhaust temperature monitoring (PCC
Isochronous under varying loads from no Class H insulation. Temperature rise up to only)
load to 100% full load. 125°C permitted for prime ratings. Tool kit
Random Frequency Variation Radio Interference Compliance to TALuft
Will not exceed ±0.25% of its mean value for In compliance with BS800 and VDE levels
constant loads – no load to full load. G and N. Cooling
50°C ambient radiator
Engine Remote radiator cooling (built to order)
Cummins KTA50G3, G7 and G8, Fuel System Oil temperature indication
sixteen-cylinder vee formation, direct 24 volt fail safe actuator, dual spin-on paper Alternator
injection, four-cycle diesel engines. element fuel filters, Cummins PTfuel Anti-Condensation heater
Type injection systems with integral electronic Thermistors
Water cooled, turbocharged and aftercooled. governor. Dual flexible fuel lines with 125/105/80°C rise alternator
Construction connectors. Standard fuel water separator.
Four valves per cylinder, forged steel Filters Exhaust System
crankshaft and connecting rods, cast iron Dry element air filters with restriction Industrial type silencer
block, with replaceable wet liners. indicator and spin-on paper element full flow Residential type silencer
Starting and by pass lube oil filters. Spin on Length of flexible exhaust and bellows
24 volt negative earth, battery charging corrosion resistor filter. Fuel System
35amp alternator. Cranking current 1800 Cooling Sub-base tanks
amps Amps at 0°C. High ambient 40°C radiator as standard with Hand fuel transfer pump
50°C ambient as option. Oil cooler. Automatic fuel transfer pump
Free-standing 450, 900 and 1350 litre
Alternator fuel tanks with stand
Type Exciter Fuel tank level switch
Brushless, single bearing, revolving field, Triple dipped in moisture, oil and acid High fuel level warning
4-pole, drip proof, screen protected. resisting polyester varnish and coated with Low fuel level warning
Class H insulation. anti-tracking varnish. Low fuel level shutdown
Enclosed to IP23 (NEMA1) standard. Sealed solid state automatic voltage Generator Set
IC 01 cooling system. regulator – self-exciting, self-regulating. Weather protective enclosures
Fully interconnected damper winding. Output windings with 2/3 pitch for improved Silenced enclosures
AC exciter and rotating rectifier unit. harmonics and parallelling ability. Control Panel
Epoxy coated stator winding. Close coupled engine/alternator for perfect SeeseparatelistonControlPanelpages
Rotor and exciter impregnated with tropical alignment. 3 or 4 pole circuit breaker up to 2500A
grade insulating oil and acid resisting Permanent magnet exciter fitted as standard. Battery charger 5 amp or 10 amp
polyester resin. Dynamically balanced rotor CE Compliance PCLand PCC systems
to BS5625 grade 2.5. Cable entrance box
Sealed for life bearings. PCCP3100 controller
Layer wound mechanically wedged rotor.
Compliance Standard Chasis
To BS4999/5000 pt 99, Fabricated and welded steel chassis
VDE 0530, UTE5100, Built-in anti-vibration mountings
NEMAMG1-22, CEMA, Optional sub-base fuel tank with eight hour
IEC 34, CSAA22.2, capacity, dual flexible fuel lines, dial type
AS1359, BSS5514, fuel gauge and drain bung
ISO 3046 and ISO 8528 Finish
Etch undercoated and finished in high gloss
durable green
General
Complete set of operating and instruction
manuals
Specifications May Change Without Notice
Technical Data
Set output 380-440 V 50 Hz 380 - 440V 380-440 V 50 Hz
Prime at 27°C ambient 1000 kWe 1256 kVA 1000kWe 1250 kVA 1120 kWe 1400 kVA
New Model (Prime) C1400 D5 C1400 D5 C1675 D5
Standby at 27°C ambient 1120 kWe 1400 kVA 1120kWe 1400 kVA 1340 kWe 1675 kVA
Engine Make Cummins Cummins Cummins
Model KTA50G3 KTA50G7 KTA50G8
Cylinders Sixteen 16 16
Engine build 60°Vee 60ºVee Vee
Governor / Class Electronic / A1 Electronic/A1 Electronic / A1
Aspiration and cooling Turbo Aftercooled Turbo Aftercooled Turbo Aftercooled
Bore and stroke 159 mm x 159 mm 159 mm x 159 mm 159 mm x 159 mm
Compression ratio 13.9:1 16.7:1 14.9:1
Cubic capacity 50.3 Litres 50.3 Litres 50.3 Litres
Starting / Min °C Unaided / 7°C Unaided / 7°C Unaided / 7°C
Battery capacity 254 A/hr 254 A/hr 254 A/hr
Gross Engine output – Prime 1097 kWm 1097 kWm 1200 kWm
Gross Engine output – Standby 1228 kWm 1228 kWm 1429 kWm
Maximum load acceptance – single step (cold) 640 kWe 640 kWe 900 kWe
Speed 1500 rpm 1500 rpm 1500 rpm
Alternator voltage regulation ±0.5% ±0.5% ±0.5%
Alternator insulation class H H H
Single load step to NFPA110 100% 100% 100%
Fuel consumption (Prime) 100% load 261 l/hr 274 l/hr 289 l/hr
Fuel consumption (Standby) 100% load 293 l/hr 303 l/hr 345 l/hr
Lubrication oil capacity 177 Litres 197 Litres 204 Litres
Base fuel tank capacity – open set (Option) 2000 Litres 2000 Litres 2000 Litres
Coolant capacity – radiator and engine 351 Litres 351 Litres 400 Litres
Exhaust temp – full load prime 520°C 472°C 485°C
Exhaust gas flow – full load prime 13421 m3/hr 12910 m3/hr 13842 m3/hr
Exhaust gas back pressure max (standby) 51 mm Hg 51 mm Hg 51 mm Hg
Air flow – radiator (40°C ambient) 21.6 m3/s 21.6 m3/s 21.7 m3/s
Pusher fan head (duct allowance) 40°C 13 mm Wg 13 mm Wg 13 mm Wg
Air intake – engine (prime) 5778 m3/hr 5508 m3/hr 5400 m3/hr
Air flow – radiator (50°C ambient) 27.1 m3/s N/A 28.4 m3/s
Pusher fan head (duct allowance) 50°C 13 mm Wg N/A 15 mm Wg
Engine heat radiated to ambient 130 kW 154 kW 175 kW
No derate for standby up to No derate at prime power up No derate up to 900m/40 C and
1400m/40 C and to 1000m/40°C and 850m/40°C. For sustained operation
850m/40°C prime. For 850m/40°C. For sustained above these conditions, derate by an
Engine derating – altitude sustained operation above operation above these additional 4.6% per 300m and 12% per
these conditions, derate by conditions, derate by an 10°C
an additional 5% per 300m additional 4% per 300m and
Engine derating – temperature and 9% per 10°C. 4% per °C
PRIME POWER RATING
The Prime Power Rating is the maximum power available during a variable load sequence which may be run for an unlimited number of hours per year. Prime power is
available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO8528-1. A 10% overload capability is available for a
period of 1 hour within a 12-hour period of operation, in accordance with ISO 3046-1.
STANDBY POWER RATING (ESP)
The Standby Power Rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage
operation capability is available at this rating. In installations served by unreliable utility sources (where outages last longer or occur more frequently), where operation is
likely to exceed 200 hours per year, the prime power rating should be applied. The Standby Power rating is only applicable for emergency and standby applications
where the generator set serves as the back up to the normal utility source.
Unless otherwise stated all ratings are based on the following reference conditions:
- Ambient temperature – 27oC
- Altitude above sea level – 150 metres
- Relative humidity – 60%
Note: In order for KTA50G7 (C1400 D5E) to meet 2g TA Luft emission norms please refer to factory for cooling system guidelines.
Specifications May Change Without Notice
Dimensions and Weights - 50 Hz
Model Engine Dimensions and Weights (mm/kg) Set Weight Set Weight
A A1 B1 B C D kg Dry kg Wet
C1400 D5 KTA50G3 5105 5150 1640 2000 2238 300 9099 10075
C1400 D5EKTA50G7 5455 5690 1640 2033 2241 300 9242 10421
C1675 D5 KTA50G8 5811 5690 1640 2033 2333 300 10324 10626
*With ambient radiator
Set weights are without sub-base tank.
Dimensions and weights are for guidance only.Do not use for installation design. Ask for certiÞed drawings on your speciÞc application.
SpeciÞcations may change without notice.
1000 (1250)
1000 (1250) See your distributer for more information
1120 (1400)
Cummins Power Generation Limited
Manston Park, Columbus Avenue
Manston, Ramsgate
Kent CT12 5BF, UK
Telephone: +44 (0)1843 255000
Fax: +44 (0)1843 255902
Email: cpg.uk@cummins.com
www: cumminspower.com
Cummins is a registered trademark of Cummins Inc.
Specifications May Change Without Notice