Mie3 Basic Eng
Mie3 Basic Eng
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                             www.mobitec.eu                     1
                                        MIE3 Basic
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                       www.mobitec.eu           2
                                                                                                                                          MIE3 Basic
1 General Notes...............................................................................................................................5
2	Installation....................................................................................................................................6
2.1	 System Requirements....................................................................................................................6
2.2	 First Installation..............................................................................................................................6
2.3	 Updating MIE3...............................................................................................................................6
2.4	 Uninstalling MIE3...........................................................................................................................6
2.5	 Licence Management.....................................................................................................................7
5	        Handling programs....................................................................................................................12
5.1	      Program definition........................................................................................................................12
5.2	      The program area........................................................................................................................12
5.3	      Create a new program.................................................................................................................13
5.4	      Select (Mark) Programs...............................................................................................................13
5.5	      Delete a program.........................................................................................................................13
5.6	      Copy/Move programs...................................................................................................................14
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                                                www.mobitec.eu                                                                              3
                                                                                                                                      MIE3 Basic
9 Generating out-Files..................................................................................................................22
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                                             www.mobitec.eu                                                                            4
                                                                                                      MIE3 Basic
1	         General Notes
MIE versions
The MIE (Mobi Info Edit) software is a text editing software developed by Mobitec. It provides an easy
and dynamic way of editing text and graphics which will be presented in a Mobitec information system.
MIE is available in two versions, as Basic and as Advanced version. Main difference is the type of sys-
tem the data is edited for. The Basic version is used for destination sign systems (or Basic Systems). In a
basic system all information is selected manually from the bus driver and doesn’t change along the route.
Typically this would be destination text and route number shown on destination signs faced to the outside
of the bus. The Advanced version is used to setup data for a complete route information system including
automatic vehicle localisation via GPS or tachometer signal. The driver has to start the route, all informa-
tion changes will be initiated automatically based on bus localisation and a preprogrammed route sys-
tem. Please refer to the system manuals for further information.
Used Symbols
        	 Warning!
	         Identifies a dangerous situation. If you do not avoid this, it can cause personal injury.
        	 Caution!
	         Identifies a situation that could have an influence on the product quality, the warranty conditions
          or could lead to data loss.
        	 Note!
	         Identifies useful information in factual connection and notes that need to be followed.
       	 Mobitec will not take any responsibility if the editing don’t comply to regional laws. Please contact
         Mobitec if a function needed for legal compliance is not offered by the MIE software.
	
         Please be aware that certain layout elements might disturb other traffic participants. Mobitec will
         not take any responsibility if the chosen layout negatively influences the traffic.
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                                www.mobitec.eu                                                  5
                                                                                                   MIE3 Basic
2 Installation
       	 If you plan to reinstall MIE on the same computer at a later stage again, it is recommended to
         keep the files not uninstalled by the uninstallation routine. They contain the most important data
         that has been generated with the MIE software.
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                               www.mobitec.eu                                                   6
                                                                                                MIE3 Basic
1.	        Copy the file and place it on the desktop (or any other user folder)
2.	        Start the MIE software
3.	        In menu “Help/Licence management” click on the tab “Read from file”
4.	        Search the file with the browser and double click on it
5.	        Click on OK and restart the MIE software
After licensing the mlk file is no longer needed and can be removed.
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                               www.mobitec.eu                                               7
                                                                                              MIE3 Basic
Rotations
                                                                                              FastInput
                       Sign Area
     Bus Config
     Templates
                        Program Area
Function of the areas is described further down in the manual in the respective chapters.
•	 Sign Area:
   Presentation of all signs activated in the Bus Config area. The signs can be zoomed in and out via
   right-click or with the mouse by left-clicking in one of the sign corners and then moving the mouse.
   Signs can be moved by click and move in the title bar of the sign window. If a sign is outside the vis-
   ible area, a scroll bar appears on the right side of the MIE3 window. Signs can be rearranged hori-
   zontally and vertically at any time in the ‘Window’ menu.
•	 Rotations window:
   Showing all rotations of the activated sign. The rotations window is a dockable window. This means
   it can be undocked from the application and freely moved on the desktop. To undock or dock the
   window, double-click in the title bar. The window can be completely switched on or off in the ‘View’
   menu.
•	 FastInput window:
   The FastInput mode offers a fast possibility of editing the signs. The FastInput window is a dockable
   window. This means it can be undocked from the application and freely moved on the desktop. To
   undock or dock the window, double-click in the title bar. The function can be activated/deactivated in
   the ‘Tools’ menu.
•	 Bus Config / Templates:
   This area can be used to either show a list of buses and configured signs or a list of available tem-
   plates. It can be switched by tabs on top of the area. The bus config window is used to activate /
   deactivate signs in the sign area. The template window is used to check/change used templates.
•	 Program Area:
   Used to handle programs. The program area has a fixed width but the height can be changed by click
   and move the top border to the sign area.
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                            www.mobitec.eu                                                8
                                                                                                   MIE3 Basic
The wizard automatically guides through the necessary steps to configure a bus system. The setup
menus are the same ones as in the manual setup described in the following chapters.
Step 1: Setting up a bus
In the first step enter a bus name and optional a bus type. Then press ‘Next’.
Step 2: Adding a sign to the bus
In the second step signs can be assigned to the bus. Click on the ‘+’ icon (Add sign to bus) to add a sign.
With the ‘-’ (Remove sign from bus) signs can be removed again.
If the required sign is not in the drop down list, press ‘Create sign’ next to the list. This opens a window to
setup sign details which is described in the Chapter ‘The sign Editor’.
Step 3: Setup sign properties
After the right sign type is selected, sign properties like address, position and template need to be as-
signed. Details can be found in the chapter ‘The bus editor’.
Step 4: Finish wizard
To setup several signs in a bus repeat steps 2 & 3 until all signs are defined. When the setup is com-
plete, the wizard can be closed by clicking ‘Finish’.
       	 After the bus configuration wizard has been used, you can directly start creating new programs
         and editing text which is described in the following main chapters. The other sub chapters within
         this main chapter are describing manual configuration or configuration change of the system.
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                              www.mobitec.eu                                                 9
                                                                                                MIE3 Basic
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                             www.mobitec.eu                                               10
                                                                                                  MIE3 Basic
                                                          Example:
                                                          This sign layout is represented by the following
                                                          template:
        	 Templates for a program should be changed before entering text. It is possible to change a
          template in a program including text, this could lead to data loss, however, if the new template
          includes less information than the previous one.
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                               www.mobitec.eu                                                11
                                                                                               MIE3 Basic
5 Handling programs
                                  Remove an existing program from the list. The control is greyed out as
                       Remove
                                  long as no program is selected
                                  Undo unsaved changes. NOTE: The database will be set back to the
                       Undo
                                  last saved version.
       	 To work with programs a sign in the bus has to be selected. Otherwise the controls are greyed
         out.
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                             www.mobitec.eu                                                12
                                                                                                   MIE3 Basic
       	 It is not mandatory to save a program after editing. MIE will handle the program normally until it
         is closed. When closing MIE warns that there are unsaved programs and offers the possibility to
         save all.
         A data loss of unsaved programs could occur, however, if the MIE software or the computer
         crashes.
                                                         When opening the dialogue box MIE automatically
                                                         suggests a new free program number. This could
                                                         be changed by the user. MIE doesn’t allow over
                                                         writing an existing program. To replace an existing
                                                         program, this has to be deleted or moved first.
                                                         For bounded line numbers, the number could
                                                         directly be edited in the line number field. Alterna-
                                                         tively the line number could also be edited later in
                                                         the number sign directly.
       	 When a program is unbounded, no text can be entered or edited in the line number area of the
         sign. The driver then chooses line number from the control unit in the bus.
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                               www.mobitec.eu                                               13
                                                                                                    MIE3 Basic
Keep internal order of program numbers (Only active when several programs are selected):
The programs are copied in a sequence keeping the original numbering order, e.g. if program #1 and #3
are copied to ‘start program number’ #5, the new programs will have the numbers #5 and #7.
Use same program number as in source bus (Only active is destination bus is different from source bus):
The copied programs will be given exactly the same numbers as the source programs.
Conflict Handling
                                                          If a number conflict occurs (program number
                                                          already occupied), the user can decide to copy/
                                                          move the selected programs to the next free pro-
                                                          gram number(s) behind the selected start number
                                                          or to over write the existing programs.
                                                          If the checkbox ‘Apply for all conflicts’ is marked,
                                                          this selection will be remembered for all future
                                                          conflicts.
       	 If ‘Apply for all conflicts’ is marked, There will be no more warnings in future when existing
         programs will be over written by a copy/move action.
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                               www.mobitec.eu                                                    14
                                                                                                    MIE3 Basic
To get an empty sign to edit, use the function ‘Create new program’.
There is an auto format function which continuously adapts the font size to the sign resolution during
editing. This function can be activated in the top toolbar by activating the button:
This function works for English and Arabic texts. It only applies for directly edited data, not for text that is
copied into the sign.
A manual autoformat for any entry can be selected with the toolbar icon:
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                               www.mobitec.eu                                                 15
                                                                                                    MIE3 Basic
Remove actual rotation. The key is greyed out if only one rotation exists.
Now the font can be selected and changed with the icons in the font toolbar:
        	 Adaptation of the text spacing should always be done after the font selection. Otherwise it can
          lead to malfunction.
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                                www.mobitec.eu                                               16
                                                                                                  MIE3 Basic
Icon Function
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                            www.mobitec.eu                                                  17
                                                                                                   MIE3 Basic
                       Second background
                                              Select second background colour
                       colour
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                               www.mobitec.eu                                                18
                                                                                                   MIE3 Basic
After entering a destination, both signs switch to the template dest (destination only):
When adding a line number, both signs switch to the template line/dest (line number and destination)
When adding a via text, the front switches to two lined display, while the side adds a rotation:
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                             www.mobitec.eu                                                19
                                                                                                     MIE3 Basic
Example:
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                              www.mobitec.eu                                                   20
                                                                                                  MIE3 Basic
       	 The bus simulator shows a simulation of the edited program for first check of the editing. Since it
         is not a full hardware emulation, differences to the real presentation on the sign might appear.
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                              www.mobitec.eu                                               21
                                                                                                     MIE3 Basic
9	         Generating out-Files
After editing is completed, an out-file has to be generated to upload the information to the Mobitec infor-
mation system. The Mobitec out file contains the complete customer setup that is generated in MIE.
To start generation of an out-File, click on the symbol:
                                                           Select the control unit type and the bus that should
                                                           be updated, then press:
                                                           •	 Next to continue with step 2
OR
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                             www.mobitec.eu                                                    22
                                                                       MIE3 Basic
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                       www.mobitec.eu                                             23
                                                                                                MIE3 Basic
 SWEDEN
 HEAD OFFICE                                           GERMANY
 Mobitec AB                                            Mobitec GmbH
 Box 97, Ölltorp Industriområde                        Stockfeldstraße 1
 52421 Herrljunga - Sweden                             76347 Rastatt - Deutschland
 Phone +46 513 229 00                                  Phone +49 7222 9297-40
 Fax +46 513 107 22                                    Fax +49 72222 9297-418
 info@mobitec.eu                                       info@mobitec.eu
 BRAZIL                                                INDIA
 Mobitec Brasil Ltda                                   CASTMASTER Mobitec Pvt Ltd
 Rua João da Costa, 570                                46 Industrial Estate, Sector 6
 Bairro São Caetano                                    Faridabad 121006
 Caxias do Sul RS - Brazil                             Haryana - India
 Phone: +55 54 320 985 00                              Phone: +91 129 406 30 01
 Fax: +55 54 320 985 40                                Fax: +91 129 406 30 07
 mobitec@mobitec.com.br                                castmaster@castmaster.com
 AUSTRALIA
 Mobitec Australia Pty Ltd
 Unit 1A/28 Skinner Ave
 Riverwood NSW 2210 - Australien
 Phone: +61 2 95 840-588
 Fax: +61 2 95 840-788
 destobob@bigpond.com.au
Please visit our website www.mobitec.eu where you will find detailed information about the Mobitec
group, our products, representative contacts, market areas and policies.
02792_MIE3_Basic_eng
REV: R03_03.11.2014
                                             www.mobitec.eu                                              24