Multi Format Switcher System
MVS-6520 System
MVS-6530 System
MVS-3000A System
MVS-3000 System
(With ICP-series Control Panel)
MVS-6520         MVS-6530            MVS-3000A   MVS-3000
ICP-6520         ICP-6530            ICP-3000    ICP-3016
ICP-6511         MKS-6550            MKS-6570
Supplement 2 [English]
Software Version 1.22
Related Manual
MVS-6520/6530/3000A/3000 System User’s Guide
Software Version 1.10 and Later
   This Supplement describes the functions made available
   by the MVS-6520/6530/3000A/3000 system software
   upgrade.
                                                                        Functions Newly
                                                                        Supported in Version 1.22
                                                                        The functions newly supported in MVS-6520/6530/
                                                                        3000A/3000 system version 1.22 are as follows.
   Table of Contents
                                                                        Functions relating to the switcher
   Functions Newly Supported in
                                                                        Classification   Functions      Menu   See User’s
      Version 1.22 .................................... SII-2                            supported      No.    page Guide
   Frame Delay Function........................... SII-3                Format           480i/59.94     7313.4 SII-3   Chapter 17
      Delaying Unconverted Input Signals...... SII-3                    converter        and 576i/50    7332           Chapter 19
                                                                                         frame delay
   Frame Synchronizer.............................. SII-3                                function
      Synchronizing Unsynchronized                                                       support
           Input Signals.................................. SII-3                         Frame          7313.4 SII-3   Chapter 17
                                                                                         synchronizer
SII-2   Table of Contents / Functions Newly Supported in Version 1.22
Frame Delay Function                                          Frame Synchronizer
The frame delay function using the format converter is        The frame synchronizer function using the format
now supported when the signal format is 480i/59.94 or         converter is now supported.
576i/50.
                                                              Synchronizing Unsynchronized
Delaying Unconverted Input Signals                            Input Signals
When the signal format is 480i/59.94, 576i/50, 1080i/         You can synchronize unsynchronized input signals using
59.94, or 1080i/50, you can set the delay of unconverted      the format converter (frame synchronizer).
input signals (frame delay function).                         The following two methods are available.
To use the frame delay function, select the target input to   Using an up-converter
set in the Engineering Setup >System >Format >Format          When the signal format is set to1080i/59.94 or 1080i/50,
Converter menu (7313.4), and select [Frame Delay] in the      the input signal can be synchronized by the up-converter.
pop-up window.
                                                              To use the frame synchronizer, select the target input to set
For details about the configuration procedure, see            in the Engineering Setup >System >Format >Format
“Setting Conversion Formats” in Chapter 17.                   Converter menu (7313.4), and select [480i/59.94 (with
                                                              FS)] or [576i/50 (with FS)] in the pop-up window.
Notes
• You can set the delay amount in 1-frame units, up to
  eight frames.
  For details about setting the delay, see “Selecting the
  Input to which the Frame Delay Function Applies” in
  Chapter 19.
• Use an input signal synchronized to the reference signal
  to obtain the same delay as that configured.
• You can use the frame delay function as a frame
  synchronizer by setting the delay value to “1.”
  For details, see “Frame Synchronizer” (page SII-3).
                                                              For details about the configuration procedure, see
                                                              “Setting Conversion Formats” in Chapter 17.
                                                              Notes
                                                              • You can synchronize the input signal to the reference
                                                                signal within a range of ±0.5 frames with respect to the
                                                                reference signal.
                                                              • If the frame synchronizer is used, the up-converter
                                                                introduces a delay of two frames with respect to the
                                                                reference signal.
                                                              Using the frame delay function
                                                              When the signal format is set to 480i/59.94, 576i/50,
                                                              1080i/59.94, or 1080i/50, you can use the frame delay
                                                              function as a frame synchronizer by setting the delay value
                                                              to “1.”
                                                                                Frame Delay Function / Frame Synchronizer   SII-3
    Notes
   • You can synchronize the input signal to the reference
     signal within a range of ±0.5 frames with respect to the
     reference signal.
   • The frame synchronizer delay is one frame with respect
     to the reference signal.
SII-4   Frame Synchronizer
MVS-6520 System
MVS-6530 System
MVS-3000A System
MVS-3000 System
(SY)
                   Sony Corporation
4-575-438-01 (1)                      © 2015