2 Circuit - Up To 6 Compressor Controllers: D: 10 DIN Rail

The document provides information on the IC200 series controllers from Dixell that can control chiller units with up to two circuits and six compressors. The IC200 allows management and control of air/air, air/water, and water/water systems. It has features like standby compressor control, forced defrosting, alarm controls, temperature and pressure unloading, and energy saving time band functions. The display has icons for temperature, pressure, compressor status, alarms and other indicators. The controllers can manage up to two evaporator and condenser pumps as well as proportional and relay outputs.

Uploaded by

JoséTorres
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
283 views4 pages

2 Circuit - Up To 6 Compressor Controllers: D: 10 DIN Rail

The document provides information on the IC200 series controllers from Dixell that can control chiller units with up to two circuits and six compressors. The IC200 allows management and control of air/air, air/water, and water/water systems. It has features like standby compressor control, forced defrosting, alarm controls, temperature and pressure unloading, and energy saving time band functions. The display has icons for temperature, pressure, compressor status, alarms and other indicators. The controllers can manage up to two evaporator and condenser pumps as well as proportional and relay outputs.

Uploaded by

JoséTorres
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

D: 10 DIN Rail

L: 38x185mm

IC200L & IC200D


2 CIRCUIT - UP TO 6 COMPRESSOR CONTROLLERS

IC200 is Dixell’s answer to the necessities of the dynamic world of conditioning. This series, allows management and control of chiller
units (with dual circuits “gas and water reversibility” and up to six compressors), heat pumps and chillers with free cooling and with
partial or total heat recovery. By means of a compact instrument, the possibility of controlling and managing system like:
air/air - “roof top”
air/water
water/water
motor-condensing

PLUS
s3INGLECIRCUITCOMPRESSORSTAND BYTHROUGHKEY
s&ORCEDDEFROSTING
s#OMBINEDDEFROSTING
s!LARMCONTROL EVENINSTAND BYORREMOTEOFF
s0UMP DOWNFUNCTIONSTOPANDSTART
s07-•M!•6OUTPUTFORCONDENSINGMANAGEMENT
s4EMPERATUREPRESSUREUNLOADINGFUNCTION
s3CREWCOMPRESSORMANAGEMENT
s#OMPRESSORROTATINGCONTROLALSOFROMSTARTHOURNUMBER
s$IRECT PART WINDING STAR DELTACOMPRESSORSTART
s$YNAMICSETPOINT
s3TARTANDSTOPBYTIMEBANDSFROM24#
s%NERGYSAVINGBYTIMEBANDSFROM24#ORDIGITALINPUT
s%ASYPROGRAMMINGTHROUGH(/4+%9OR0#02/'4//,+)4
s23SERIALOUTPUTWITH-OD"53PROTOCOL

16
DISPLAY MEANING
ICON

Celsius - Fahrenheit degrees

Bar-PSI

Compressor 1

Compressor 2

Compressor 3

Compressor 4

Compressor 5

Compressor 6
COMPLETE
Generic alarm
The dual display and the 16 icons display
Water pump complete information about the machine
ICON MEANING status. With a single touch of one key, all main
Flow alarm
functions of the cooling system are displayed
Time/RTC !58RELAYOUTPUTNª
without the need to enter programming mode.
%VAPORATORANTI FREEZINGHEATER !58RELAYOUTPUTNª

Condenser fan Defrost

CONNECTIONS
All the controllers of the
ICHILL series, have rapid
wiring connections.

CONTROLLED DEVICES
sCIRCUIT COMPRESSORUPTOCAPACITYSTAGESMANAGEMENT
sCIRCUITS COMPRESSORUPTOCAPACITYSTAGESMANAGEMENT
sCIRCUITS COMPRESSORMANAGEMENT
s-ANAGEMENTOFUPTOEVAPORATORSECTIONANDCONDENSERSECTIONWATERPUMPS
s-ANAGEMENTOFUPTOPROPORTIONALOR/./&&OUTPUTS•6
sCONlGURABLE!58RELAYOUTPUTS
s5PTOREMOTEKEYBOARDMANAGEMENT

ALARM MANAGEMENT
The user interface provides complete visual information about the plant status and allows acknowledgement of any alarm
event signals.

Each alarm has a dedicated label Alarm reset protects by password Internal data logger (up to 100 events)
(eg. C1tr: thermal compressor 1 alarm)

17
IC260L - IC280L
IC260D - IC280D

IC261L - IC281L
IC261D - IC281D

Analogue input for ratiometric pressure transducer PPR30 Analogue input for pressure transducer PP30 (4÷20mA signal)
(0÷5V signal)

PWM output for condensing single-phase fans 0÷10V or 4÷20mA output for condensing three-phase fans

Proportional outputs configured for aux relay control Proportional outputs configured for damper control (0÷10V)

19
EXAMPLE OF APPLICATION FOR 2 CIRCUIT UP TO 6 COMPRESSOR AIR/WATER CHILLER

20