VENT WAY CALCULATIONS :
Length of Weir L= 62.3 metres
For BC weir Q = Cd L H^3/2
1.70 X 62.3 X (0.609)^3/2
Discharge = 50.334 cumecs
Assumed Velocity in the Barrel = 1.80 m / sec
Area Required = Q / V = 27.963 Sq.mt
Considering a Vent size of 6.60 m x 2.20 m.
No.of Vents required = 1.926 no.
say 2 no.s
Velocity in the vent = 1.73 m / sec
Provided Vent size of 6.60 m x 2.200 m.
No.of Vents Provided 1.926
say 2 no.s
Velocity in the vent = 1.73 m / sec