HV RELAYS ISO 9001:2015 HV PROBES
HV SWITCHES QMS CERTIFIED HV DIVIDERS
HV CONTACTORS ISO/IEC 17025:2017
CALIBRATION CERT #2746.01
HV VOLTMETERS
HV MEASUREMENT HV HIGH CURRENT
HV ENERGY STORAGE HV CALIBRATION LAB
HV SAFETY & ACCESSORIES ELECTRONIC & HIGH POWER
HV RESISTIVE OR CAPACITIVE LOADS HV HIPOTS TO 50kV DC / 100kV DC
10V to 1,200,000V ● MicroAmps to 1,700,000 Amps PK Pulse ● DC to 10MHz
R OSS E NGINEERING C ORPORATION
540 WESTCHESTER DRIVE U.S. TOLL FREE: 1-800-654-3205
CAMPBELL, CA 95008 PHONE: (408) 377-4621
UNITED STATES FAX: (408) 377-5182
www.rossengineeringcorp.com
e-mail: info@rossengineeringcorp.com
HIGH VOLTAGE DEVICES
HIGH VOLTAGE RELAYS
1kV to 300kV
1mA to 800 Amps
12''
3''
EE12 ES12 ET2-14 EA25 E40 E60 E70 - 70kV ED150 - 150kV
12kV 12kV 14kV 25kV 40kV 60kV Gravity Return, Gravity Return,
Mount Base Up Mount Base Down
ACTUATORS 12V TO 250V DC, 24V TO 480V 25-800Hz OR AIR PRESSURE 40-125 PSI
HIGH VOLTAGE RELAYS AIRPORT LIGHTING HV CONTROL RELAYS
Air insulated types for isolating loads, Reliable single pole and 2-pole
tap selection, safety discharge & HV Relays developed for use for
grounding to help meet OSHA & other switching airport runway lighting
safety regulations. Ratings from 1mA with over 20 years of trouble-free
6''
4''
to 800 Amps continuous, to 100,000 use up to 2400V, 50/60Hz, up to
Amps capacitor discharge. Peak 1 20 Amps maximum interrupt, has
minute test voltages from 5 to 300kV. been now upgraded to also
Single or Multi-pole. Auxiliary contacts handle up to 5000V 50/60Hz,
optional on all types. Options include 12 Amps maximum interrupt.
latching, extended life, and tungsten Unit is air insulated, does not
contacts available for high current require vacuum, oil or
closing. DC, 25-800Hz & air pressure sulfurhexafluoride insulation or a
E40-2PNO
actuation available. Also usable in oil leak tight container. Has 25 to 40kV PK TEST
E25-NC-25-1-0 or insulating gas with increased 100 Amps maximum continuous capability,
25kV PK TEST
ratings. a peak 1 minute test of 10 to 28kV RMS and
operates with 115V or 230V 50/60Hz actuator.
DELAYED OPEN OR CLOSE HV RELAYS HIGH VOLTAGE REED RELAYS
High Voltage Relays with 5,000V TO 15,000V PK TEST
automatic delay but positive 3 Amps Continuous. 50 to 100 Volt Amps Max Interrupt.
6''
closing or opening after turn 6V DC to 115V 50/60 Hz coil. Choice of terminal type or
on, turn-off, or loss of power. HV leads.
They are designed for safety
shorting, or current flow
which must not be initiated 1''
or interrupted accidentally
before a prescribed time
after actuation or shutdown.
RR1A07Q24 RR1C07H24S
E40-NC-40-1-0-ZA,
SPNO SPNO
1-3 SECONDS DELAY TO CLOSE
7kV PK TEST 7kV PK TEST
40kV PK TEST
QUICK DISCONNECT TERMINALS HOOK, SOLDER TERMINALS
24V DC ACTUATOR 24V DC ACTUATOR
STUD MOUNTING
Specifications and Dimensions are for reference only and are subject to change. Contact Ross Engineering Corporation for current information.
ISO 9001:2015 540 Westchester Dr., Campbell, CA 95008
QMS CERTIFIED PHONE:(408)377-4621 FAX:(408)377-5182
www.rossengineeringcorp.com
2 e-mail: info@rossengineeringcorp.com ISO/IEC 17025:2017
CALIBRATION CERT #2746.01
HIGH VOLTAGE DEVICES
WIDEBAND HV VOLTAGE DIVIDERS 27''
1kV to 1200kV
DC-10 MHz
3''
VD5 VD15 VD60 VD75 VD120-Indoor VD120-Outdoor VD150 VD450
5kV 15kV 60kV 75kV 120kV 120kV 150kV 450kV
Precision compensated resistive-capacitive Voltage Dividers for DC up to 10MHz or to 0.02 microsecond
rise time pulse. 1000/1 ratio matched to 1 megohm 20 to 50pF display or recorder. Other ratios and loads
as required. Accuracy and stability: 0.01% to 0.1% DC, 0.04% to 1% AC, 3% DC-1MHz, 3dB to 10MHz.
For use in air, oil, or gas. Contact Ross Engineering Corp. for complete accuracy specifications.
HIGH VOLTAGE MEGMETER®, HIPOT to 50kV HIGH VOLTAGE CALIBRATION LAB to 450kV
HV Insulation Leakage Current & HV Resistance ISO/IEC 17025:2017 ACCREDITED
Measurement Meter. HV Vacuum Interrupter Tester. Calibration of HV Voltage Dividers, HV Voltmeters, HV
Portable, 12V battery or 115V AC operated. Probes and HV Equipment to NIST standards. AC and DC
0-15kV DC 0.001μA to 260μA or to 2000μA. includes multiple test points and certificate. 1kV up to 450kV
0-42kV DC 0.001μA to 130μA or to 750μA. PK AC & Impulse,
0-50kV DC 0.001μA to 1200μA. 400kV DC.
VMT-15
0-15kV DC
7''
VMT-42 ISO/IEC 17025:2017
0-42kV DC CALIBRATION CERT #2746.01
VMT-50
0-50kV DC FOR THE
CALIBRATIONS
TO WHICH A2LA ACCREDITATION APPLIES, PLEASE REFER TO
FOR TESTING HV VACUUM INTERRUPTERS, HV CABLES & HV INSULATION THE LABORATORY’S CALIBRATION SCOPE OF ACCREDITATION.
AC/DC DIGITAL HIPOTS PERSONAL GROUNDING RODS
0-60kV AC, 0-73kV DC, 0-130kV AC, 0-160kV DC Personal Grounding Rods temporarily ground or discharge
Specifically designed for Calibrating High (with current limiting if required) 50V-400kV electronic
Voltage Measurement Devices or Testing High equipment that could present a safety problem. Rods are
hooked on to HV terminals, or other points where contact
Voltage Equipment, Insulation and HV Vacuum
will ground the device. Designs conform to OSHA
Interrupters or other HV Vacuum Devices.
clearance requirements and provide the correct handle
AC ONLY and cable length to keep personnel away from hazardous
12'' 0-60kV AC high voltage
ACC401-60-5/10- 30''
0-130kV AC
ACC401-130-5/10- 1''
AC/DC
HIGHER CURRENT 0-60kV AC / 0-73kV DC NOT FOR HIGH
UP TO 80mA ACC402-60/73-5/10- CURRENT UTILITY
POWER LINE USE
0-130kV AC / 0-160kV DC
ACC402-130/160-5/10-
Specifications and Dimensions are for reference only and are subject to change. Contact Ross Engineering Corporation for current information.
ISO 9001:2015 540 Westchester Dr., Campbell, CA 95008
QMS CERTIFIED PHONE:(408)377-4621 FAX:(408)377-5182
www.rossengineeringcorp.com
e-mail: info@rossengineeringcorp.com ISO/IEC 17025:2017 3
CALIBRATION CERT #2746.01
HIGH VOLTAGE DEVICES
HIGH CURRENT SWITCHES TOROIDS, SPHERES,
CORONA NUTS & SHIELDS
40''
Models are available up to
Geometrically designed to
20,000 Amps continuous, and
avoid excessive voltage
over 1,700,000 Amps 20μsec 1''
gradients at connecting points
pulse, with voltage ratings of 6
and other areas needing
volts to 400kV peak test. Many
shielding or balancing of
are air cylinder or motor operated
electrostatic fields to increase
for high contact force. DC to
withstand voltage and minimize
1MHz.
corona. Many diameters are to
Spheres Toroids
international standard metric
GD27-P-40-8000
27kV PK TEST
Sizes sizes sizes.
0.2” to 22” 0.75” to 52”
8000A CONTINUOUS 0.5cm to 56cm 1.9cm to 132cm Non melting solid carbon
spheres available for long
life spark gaps
HIGH VOLTAGE ROTARY SWITCHES MULTIPOLE HIGH VOLTAGE RELAYS
12kV, 25kV, 40kV, 60kV PK Test
Ratings from 5 to 150kV, 1 to 200 Amps. Either manual 12''
or electrical operators, depending upon requirements. The E Series Multipole High Voltage
Position detents and interlocks to prevent opening Relays are designed for high voltage
under load. applications where multiple poles
are required.
6''
R30-
Available up to 50 Poles 5 POLES
30kV PK TEST E25-2PDT-25 E25-2PDT-25
Vertical Low Profile
HIGH POWER RF SWITCHES HIGH SHOCK RELAYS
10''
High Voltage RF Switch designed Developed and manufactured
and manufactured for high power for shipboard explosion
communication transmitters. Up to resistance 250G shock, 27kV,
450kV PK test 6000 Amps RMS. double throw, DC-400Hz
Motor or air actuated. Single throw actuator. 100 Amps
or double throw. Continuous
3000 Amps Continuous 13KHz
1500 Amps Continuous 30KHz
GD450-DOUBLETHROW E30-DT-40-G
450kV PK TEST 30kV PK TEST
1500 AMPS,
30KHz
Specifications and Dimensions are for reference only and are subject to change. Contact Ross Engineering Corporation for current information.
ISO 9001:2015 540 Westchester Dr., Campbell, CA 95008
QMS CERTIFIED PHONE:(408)377-4621 FAX:(408)377-5182
www.rossengineeringcorp.com
4 e-mail: info@rossengineeringcorp.com ISO/IEC 17025:2017
CALIBRATION CERT #2746.01
HIGH VOLTAGE DEVICES
POWER QUALITY AND LINE DISTURBANCE HV PROBES & HV VOLTMETERS FOR
1kV-1000kV MEASUREMENT & RECORDING OSCILLOSCOPES, DVMS, RECORDERS
Power class sensors, Wideband Voltage Dividers for use with HV DC, AC & Wideband DC-10MHz. Safety probes for any
DRANETZ/BMI, RPM, FLUKE, TEKTRONIX, YOKOGAWA & scope, digital display or recorder. Also available complete with
other recorders. Matched to: large 4½ digit display 0.01% to 5% DC/AC accuracy digital
DRANETZ / BMI
voltmeter, with safety handles for OSHA recommended
23''
personnel clearances. With attached or separate digital
display or multimeter 0.00001V to 400kV.
6''
VD120
PowerGuide 4400 MeasuringPad
VMD2A-200-DC-10MHz DVM
38kV RMS
POWER FLUKE BATTERY/AC POWERED
CLASS
430 Series 1735 Three-Phase HV PROBE
Power Logger TO 400kV
INDOOR OUTDOOR Product Photos Appear Courtesy Of:
Dranetz/BMI Inc. & John Fluke Mfg. Co.
DC-1MHZ
WEATHERPROOF WIDEBAND HV DIGITAL MULTIMETERS
258''
HIGH VOLTAGE DIVIDERS Wideband DC-10MHz. VMD2A 4½ digit portable meter has
accuracies to 0.01% DC, 0.1% 50/60Hz, 3% DC-1MHz,
High accuracy 5kV RMS to 345kV RMS 3dB to 10MHz. True RMS, Avg, True +PK, -PK, PK to PK,
power class. 30kV PK to 1000kV PK 0.2 microsecond, ½ sine single pulse capture & hold.
operate. 60kV to 1350kV basic impulse 0.00001V - 1000V DC or PK AC and for use with HV
level. DC to over 1MHz frequency Probes to 400kV and Voltage Dividers to 1,000,000V. Has
response. For DC, AC power quality, line 2V output to scope, recorder. 6''
disturbance & transient measurement
and recording. VMD2A
MULTIMETER VD30-12.5Y-A-LB-A,
30kV PK OPERATE
VOLTAGE DIVIDER
VD1000-20-T-KB-B
1,000,000V DC OR PK AC OPERATE
WIDEBAND FIBER OPTIC TRANSMISSION HIGH VOLTAGE POWER &
DC-1MHz & 50-75 OHM OUTPUT TRANSIENT ISOLATORS
COAXIAL CABLE DRIVER DC-35MHz 120V/240V AC RMS 50/60Hz
AC or 12V DC rechargeable battery/AC operated. Motor Generator Type
Systems have a maximum output of 10V PK (20V PK to
PK) 10mA and a maximum signal input of 10V PK. Useful
25'' Transformer Type
from 0.1V, and to over 1000kV when used with Ross HV
Wideband Dividers. Single or multiple ranges.
FIBER OPTIC TRANSMITTER COAXIAL
AND RECEIVER CABLE DRIVER
4''
DC - 1MHz DC - 35MHz 115V, 230V AC Driver Air Insulation 60kV Solid Insulation
1000MΩ 30pF INPUT IMPEDANCE 1MΩ 30pF INPUT IMPEDANCE Motor at ground or more 50kV PK Potted
Specifications and Dimensions are for reference only and are subject to change. Contact Ross Engineering Corporation for current information.
ISO 9001:2015 540 Westchester Dr., Campbell, CA 95008
QMS CERTIFIED PHONE:(408)377-4621 FAX:(408)377-5182
www.rossengineeringcorp.com
e-mail: info@rossengineeringcorp.com ISO/IEC 17025:2017 5
CALIBRATION CERT #2746.01
HIGH VOLTAGE DEVICES
LOW PROFILE VACUUM CONTACTOR HV VACUUM CONTACTORS
208V TO 15.5kV 50/60Hz & CIRCUIT BREAKERS
1½ to 2 cycle
12''
interrupt. Highly 30''
reliable vacuum
interrupting
capability of up to
750MVA at 15.5kV
AC, with momen-
HG3 Low Profile
tary current to
200, 400, 600, 1200 Amp
2000 to 28000 Amp Interrupt 20,000 Amps
HB-204-
RMS, 56,000 200kV HA3-73-110-600-AMP
Amps PK-PK for 10 cycles, and 40,000 Amps RMS for PK TEST 5-15.5kV CLASS
one cycle fuse protected. Three SPDT form C, 15A, 480V 200-1200 AMP to 38kV RMS CLASS
AC auxiliary contacts are standard and up to four may be
208V TO 300kV AC OR DC, 50A TO 2000A CONTINUOUS,
specified.
10A DC TO 28000A AC ½ TO 1 CYCLE INTERRUPT.
Hi-Z® HIGH VOLTAGE VOLTMETERS VACUUM CONTACTORS WITH HIGH SPEED
SAFE POWER LINE USE AC / DC TO 100kV CONTACT OPENING AND ENERGY
For phasing, capacitance tap or direct line measurement STORAGE DRIVERS
and hot line indication. Power class safe, portable all solid
state, 0.5% to 5% accuracy. Shielded high voltage mea- As low as 1 millisecond contact opening
surement with minimum circuit loading. 0.001V to 100kV AC or closing, is available with ratings from
or AC/DC. 125kV to 300kV BIL. Ideal for use with elbow 300V to 300KV and 50 to 1200 Amps
capacitance tap voltage test points. For cable test points continuous, 10 Amps DC to 12,000 Amps
and direct line voltage and 4'' AC interrupt, 40,000 Amps momentary.
phasing, or differential
measurement. Analog 12''
Energy Storage
or Digital available. Driver, 400 joules or
more, 115V or 240V
ALSO HOT LINE VM50D METER AC powered, 50V to
INDICATION Ranges: 0-200V, 2kV, 20kV, ENERGY STORAGE 1000V 20 microsec-
25kV, 50kV or 100kV RMS AC HAF-73- SCR CONTROL ond trigger.
FOR UTILITIES, CONTRACTORS & EMERGENCY SERVICES HCB-5-C-E-E
COLLAPSIBLE HOT STICKS HIGH VOLTAGE SPHERICAL RELAYS
18'' Designed to maintain Ultra high voltage, low corona,
proper safety clearances transfer, polarity reversing,
from hazardous High and grounding relays of the
Voltage while hand holding air insulated type. Ratings up
a test instrument. The to 600kV PK at 100 Amps
1¼in or 1½in diameter continuous. Solenoid, motor
sections of the Hotstick 12'' or air cylinder operated and
form a rigid handle from spring or gravity return.
1½ft to 18ft in length with
100kV/foot test voltage,
depending on your specific
INSULATED HANDLES needs.
DH-300-NC-40-2-0
300kV PK TEST
Specifications and Dimensions are for reference only and are subject to change. Contact Ross Engineering Corporation for current information.
ISO 9001:2015 540 Westchester Dr., Campbell, CA 95008
QMS CERTIFIED PHONE:(408)377-4621 FAX:(408)377-5182
www.rossengineeringcorp.com
6 e-mail: info@rossengineeringcorp.com ISO/IEC 17025:2017
CALIBRATION CERT #2746.01
HIGH VOLTAGE DEVICES
SOLENOID-SAVER® 24V to 300V AC/DC HV ADJUSTABLE SPARK GAPS
For high pull-in current, low holding current 25-800Hz AC
or DC solenoid actuators to prevent coil burnout, lower Non-melting carbon
6''
coil temperature rise and increase pull-in and holding spheres, and heavy
forces. Eliminates AC hum. Can provide optional low wall aluminum
current, low voltage control with 5mA 4-10V or other spheres, .2” to 22”,
signal, optional delayed activation or deactivation, or 0.5cm to 56cm DIA.
optional high speed energy storage activation. Will allow With dust tight
any DC or AC solenoid to be used at DC or 25-800Hz. transparent covers
2kV to 88kV.
Open style to
2'' 670kV. Micrometer
type calibrating
devices.
SG-40-H
4-40kV PK
AC SOLENOIDS HIGH POWER, HIGH SPEED HIGH VOLTAGE
CONTROL AND STEP-START SYSTEM
3''
½ to 1 cycle sensing
and interrupting vacuum
circuit breakers. Metal
60'' enclosed for indoor or
outdoor applications.
5kV-38kV. Step-Start
systems to minimize
inrush current. 200-
AC Quiet. DC to 800Hz. Class B or H Insulation. 1,200 Amps Continuous,
Extendable Stroke. Universal Mounting. Higher 2,000-28,000 Amps
Holding Force. Environment resistant. Optional Interrupt.
Electronic Controller. 24V, 120V, 208V, 240V, 480V HD3-79-110-
coil voltages are standard. Other voltages and 5-15kV CLASS, 95-110kV BIL
1200A CONTINUOUS, 28,000A INTERRUPT.
frequencies are also available.
ESD TESTER HV LOADS
For static discharge testing 0-5kV, 0-30kV, 0-300kV. It 1kV TO 300kV
incorporates high voltage relays to safety ground, charge, 2 TO 200 KILOWATTS
and dump a 50PF to 2MFD, 25kV capacitor into the
appropriate device under test. Portable system utilizing
120V AC power to
operate. It is a high
24'' reliability device
capable of many
thousands of cycles.
ESD-40
Specifications and Dimensions are for reference only and are subject to change. Contact Ross Engineering Corporation for current information.
ISO 9001:2015 540 Westchester Dr., Campbell, CA 95008
QMS CERTIFIED PHONE:(408)377-4621 FAX:(408)377-5182
www.rossengineeringcorp.com
e-mail: info@rossengineeringcorp.com ISO/IEC 17025:2017 7
CALIBRATION CERT #2746.01
INTERNATIONAL REPRESENTATIVES
ARGENTINA CHINA - SHANGHAI / CHINA INDONESIA PERU
Inducor Ingenieria SA ATiS Test & Measurement Ltd. PT Malvindo Harmoni Pratama Energetica S.A.
Maximo Paz 207 Shanghai Headquarters Jl. Ahmad Yani no. 2. Av. Victor Maurtua 140, Of. 501
Lanus Oeste - B1824KSA Rm 1010, UDC Bldg, No. 728, Xinhua Rd Perkantoran Pulomas satu, Lima 27, Peru
Buenos Aires - Argentina Shanghai 200052, China Gedung II (dua), Lt. 2 Ruang 09 Kel. Tel: 51-1-421-6566
Tel: 54-11-4249-7052 Tel: 86-21-62830131 Kayu Putih. Pulogadung. Fax: 51-1-421-6536
Fax: 54-11-4249-7053 Fax: 86-21-62832240 Jakarta Timur. Email: energesa@energesa.com
Email: inducor@inducor.com.ar Email: gina.tang@atis.com.cn Tel: 62-21-298-47915
Website: www.inducor.com.ar Website: www.atis.com.cn Fax: 62-21-298-47915 PORTUGAL
Email: purna.bimantara@malvindo.com Equilamang - Tecnologias em Movimento
AUSTRALIA ECUADOR Website: www.malvindo.com Av. Alves Redol, 23B
Oxford Scientific Proteco Coasin S.A. 2720-034 Amadora
Unit 4, 7 Millennium Court Av. 12 de Octubre N26-141 y Orellana ISRAEL Portugal
Silverwater NSW 2128, Australia 17-03-228A Ecuador Bentronix Ltd. Tel: 351-214757515
Tel: 02-9748-8766 Tel: 593-2-250-0616 / 255-7713 P.O. Box 2288, Fax: 351-214757499
Fax: 02-9748-0233 Fax: 593-2-250-0617 Neve-Monosson, Email: geral@equilamang.com
Email: sales@oxfordscientific.com.au Email: ventasuio@protecocoasin.com Israel 60190 Website: www.equilamang.com
Website: www.oxfordscientific.com.au Website www.protecocoasin.com Tel: 972-3-5366039
Fax: 972-3-5365781 SOUTH AFRICA
ZPower Engineering ENGLAND Email: sales@bentronix.co.il Denver Technical Products (Pty) Ltd
Level 11, Brookfield Place Glassman Europe Ltd. Website: www.bentronix.co.il 32 Bessemer Road Heriotdale,
125 St Georges Terrace 21 Campbell Court Johannessburg, South Africa
Perth, WA 6000 Campbell Road, Bramley ITALY Tel: 11-626-2023
Tel: 08-6557-6675 Hampshire, RG26 5EG Pulse MC2 Fax: 11-626-2009
Email: harry@zpowerengineering.com.au Tel: 44-01256-883007 7 allée du Brévent Email: denvertech@pixie.co.za
Website: www.zpowerengineering.com.au Fax: 44-01256-883017 SILIC 1416 - Courcouronnes Website: www.denvertech.co.za
Email: sales@glassmaneurope.co.uk 91019 EVRY Cedex,
AUSTRIA Website: www.glassmaneurope.co.uk France SPAIN
PMK Mess- & Kommunikationstechnik GmbH Tel: 33-1-60-86-21-26 Pulse MC2
Konigsteiner Str. 98 FRANCE Fax: 33-1-64-97-54-98 7 allée du Brévent
D-65812 Bad Soden am Taunus, Germany Pulse MC2 Email: michel.chaillou@pulsemc2.fr SILIC 1416 - Courcouronnes
Tel: 49-6196 / 5927-930 7 allée du Brévent Website: www.pulsemc2.com 91019 EVRY Cedex, France
Fax: 49-6196 / 5927-939 SILIC 1416 - Courcouronnes Tel: 33-1-60-86-21-26
Email: sales@pmk.de 91019 EVRY Cedex, France JAPAN Fax: 33-1-64-97-54-98
Website: www.pmk.de Tel: 33-1-60-86-21-26 Comcraft Corporation Email: michel.chaillou@pulsemc2.fr
Fax: 33-1-64-97-54-98 1-2-4 Momoi Website: www.pulsemc2.com
BELGIUM Email: michel.chaillou@pulsemc2.fr Suginami-Ku
Air Parts B.V. Website: www.pulsemc2.com Tokyo, 167-0034 SWEDEN
Ondememingsweg 66-H Tel: 81-3-3395-5553 High Voltage i Vasteras AB
2404 HN Alphen aan den Rijn GERMANY Fax: 81-3-3395-5666 Anghammargatan 1 B
The Netherlands PMK Mess- & Kommunikationstechnik GmbH Email: info@comcraft.co.jp S-721 33 Vasteras
Tel: 31-172-422-455 Konigsteiner Str. 98 Website: www.comcraft.co.jp Sweden
Fax: 31-172-421-022 D-65812 Bad Soden am Taunus, Germany Tel: 46-21-120405
Email: info@air-parts.com Tel: 49-6196 / 5927-930 KOREA Fax: 46-21-120409
Website: www.air-parts.com Fax: 49-6196 / 5927-939 KJ Dynatech Inc. Email: mail@highvoltage.se
Email: sales@pmk.de Suite 506, Byucksan DigitalValley 6, Website: www.highvoltage.se
Pulse MC2 Website: www.pmk.de #219 Gasan-digital 1-ro
7 allée du Brévent Gasan-dong, Geumcheo-gu, SWITZERLAND
SILIC 1416 - Courcouronnes GREECE Seoul 08501 PMK Mess- & Kommunikationstechnik GmbH
91019 EVRY Cedex, France Electrotype LTD Tel: 82-2-858-9844 Konigsteiner Str. 98
Tel: 33-1-60-86-21-26 29 Simantira Str Fax: 82-2-858-3047 D-65812 Bad Soden am Taunus
Fax: 33-1-64-97-54-98 Athens 42, 10023, Greece Email: info@kjdyna.com Germany
Email: michel.chaillou@pulsemc2.fr Tel: 30-210-85-44-966 Website: www.kjdyna.com Tel: 49-6196 / 5927-930
Website: www.pulsemc2.com Fax: 30-210-85-44-967 Fax: 49-6196 / 5927-939
Mobile: 30-693-20-52-659 MALAYSIA Email: sales@pmk.de
BRAZIL Email: elektrotyp_epe@elektrotyp.gr PT Malvindo Harmoni Pratama Website: www.pmk.de
G&M Comercio de Produtos Ltda. Jl. Ahmad Yani no. 2.
Rua Senador Queiros 165 NetScope Solutions S.A. Perkantoran Pulomas satu, TAIWAN, R.O.C.
Santo Andre, Sao Paulo Lachana 4 Gedung II (dua), Lt. 2 Ruang 09 Kel. Metrologies Enterprise Co., Ltd.
CEP 09050-300 14342 New Philadelphia Kayu Putih. Pulogadung. Jakarta Timur. 8F, No.30, Sec.1
Tel: 55-11-4425-4245 Athens, Greece Tel: 62-21-298-47915 Min Shen E. Rd.
Fax: 55-11-4426-8579 Tel: 30-210-27-24-107 Fax: 62-21-298-47915 Taipei 104, Taiwan, R.O.C.
Email: marcelo@gmtestemedicao.com.br Fax: 30-210-27-11-999 Email: purna.bimantara@malvindo.com Tel: 886-2-2537-3650 Ext.21
Website: www.gmtestemedicao.com.br Email: netscope@netscope.gr Website: www.malvindo.com Fax: 886-2-2537-6602
Website: www.netscope.gr Email: metrolo.gies@msa.hinet.net
CHINA - HONG KONG NETHERLANDS Website: www.metrologies.com.tw
Euro Tech (Far East), Ltd. INDIA Air Parts B.V.
Hong Kong Headquarters Nexgen Electric & Cable Co Ondememingsweg 66-H
18/F Gee Chang Hong Center Vip Enclave Vip Road Block A1 2404 HN Alphen aan den Rijn
65 Wong Chuk Hang Road, Hong Kong Shop No 12 & 13 Kolkata 700059, India The Netherlands
Tel: 852-2814-0311, 86-20-38201660 Tel: 91-33-25006665 / 22190134 / 9836636663 Tel: 31-172-422-455
Fax: 852-2870-0479 Fax: 91-33-22190133 Fax: 31-172-421-022
Email: conniechan.hk@euro-tech.com Email: nexgen.vimal@gmail.com Email: info@air-parts.com
Website: www.euro-tech.com Emal: vimal@nexgenhv.com Website: www.air-parts.com
Copyright © 2018 Ross Engineering Corporation 07/2018