Ultrasonic Flaw Detector
SX
OmniScan SX
Smaller, Lighter … Still an OmniScan
                               •	 Cost-efficient, single-group
                               •	 Two-axis encoding and data
                                  archiving capacity
                               •	 Conventional UT, TOFD, and
                                  16:64PR PA capabilities
                               •	 8.4 in. (21.3 cm) touch screen
                                  with OmniScan interface
                               •	 Compact, lightweight design
    The Lightest and Most
    User-Friendly OmniScan
    OmniScan SX
    Olympus is proud to introduce the OmniScan® SX, a flaw detector that benefits from more than 20 years of phased array
    experience and shares the OmniScan DNA. For improved ease of use, the OmniScan SX features a new streamlined software
    interface displayed on an 8.4 in. (21.3 cm) touch screen. A single-group and non-modular instrument, the OmniScan SX is
    easy to operate and cost-effective for less demanding applications.
    The OmniScan SX comes in two models: the SX PA and SX UT. The SX PA is a 16:64PR phased array unit, which, like the
    UT-only SX UT, is equipped with a conventional UT channel for pulse-echo, pitch-catch or TOFD inspection. Compared to the
    OmniScan MX2, the SX is 33% lighter and 50% smaller, offering an unprecedented level of portability for an OmniScan.
    Setup                                                         Acquisition
    Inspection setup can be performed in NDT SetupBuilder,        The OmniScan SX enables easy configuration of inspection
    and imported directly, via SD card or USB key, to the         parameters for either manual, one-line, or raster encoded
    OmniScan SX. Then, only a few basic operations are            scans. The acquisition is displayed in real time through
    required in the instrument, such as setting the gate and      user-selectable views and offers the ability to store data on a
    range, before acquisition can begin. It is also very easy     hot-swappable SD card or USB 2.0 device.
    to create a setup right in the OmniScan SX, thanks to the
    following features:                                            •	 Intelligent layouts.
                                                                   •	 Full-screen mode for better visualization of defects.
     •	 Automatic probe recognition.
                                                                   •	 Synchronization and measurements can be processed using
     •	 One-step, preconfigured application Wizard.                   different gate combinations.
     •	 Weld Overlay and RayTracing simulation.
                                                                  Data Analysis and Reporting
    Calibration                                                    •	 Data, reference, and measurement cursors for defect sizing.
    To achieve a code-compliant inspection, the Calibration        •	 Extensive readings database and predefined lists for trigono
    Wizard ensures that every focal law in every group is the         metry, flaw statistics on axes, volumetric position information,
    direct equivalent of a single-channel conventional flaw           code-based acceptance criteria, corrosion mapping statistics,
    detector. The user is guided step-by-step through the             and more.
    required calibrations, including Velocity, Wedge Delay,        •	 Views are linked for interactive analysis and automatically
    Sensitivity, TCG, DAC, AWS, and encoder calibrations. Now,        updated when performing off-line gate repositioning.
    TOFD PCS calibration and lateral wave straightening can be     •	 Optimized preconfigured layouts for quick and simple length,
    performed automatically.                                          depth, and height sizing of flaws.
                                                                  Whether you prefer performing data analysis on a computer
                                                                  or simply wish to maximize the time your OmniScan is at
                                                                  work in the field, OmniPC or TomoView are the perfect
                                                                  software companions for your OmniScan.
2
Affordable and Portable
Go a Long Way….
The Omniscan® SX provides Olympus with a new and versatile tool to add to its arsenal of innovative and creative
complete market solutions aimed at simplifying your workflow and improving overall productivity.
Phased Array Weld Inspection                                       Corrosion Mapping and Composite Inspection
The OmniScan PA is at the heart of the manual and                  Zero-degree inspection just became even more acces-
semiautomated phased array weld inspection solutions              sible with the arrival of the OmniScan SX. For corrosion or
developed by Olympus for the oil and gas industry. These           composite inspection, Olympus offers field-proven solutions
systems can be used for inspection in compliance with              for detection of anomalies or wall loss.
ASME, API, and other code criteria, while offering high-
speed detection capabilities, and facilitating indication
interpretation.
TOFD Weld Inspection                                               Component Inspection
TOFD is an easy and efficient approach for primary detection       Using ultrasonic techniques, inspection of components
of weld defects. It is quick, cost-effective and capable of siz-   can detect cracks, wall loss, and other damage. With the
ing defects present in the volume of the weld, a problematic       capacity for both angle and linear zero-degree beams, the
area for manufacturing defects.                                    OmniScan SX is a very cost-efficient solution for this type of
                                                                   single-group inspection.
                                                                                                                                    3
OmniScan® SX Specifications*
 Housing                                                                                                              Ultrasound Specifications (applies to OMNISX-1664PR)
 Overall dimensions             267 mm × 208 mm × 94 mm                                                               Connectors                            1 Phased Array connector: Olympus PA connector
 (W x H x D)                    (10.5 in. × 8.2 in. × 3.7 in.)                                                                                              2 UT connectors: LEMO 00
 Weight                         3.4 kg (7.5 lb) with battery                                                          Number of focal laws                  256
 Data Storage                                                                                                         Probe recognition                     Automatic probe recognition
 Storage devices                SDHC card or most standard USB                                                        Pulser/Receiver
                                storage devices
                                                                                                                      Aperture                              16 elements
 Data file size                 300 MB
                                                                                                                      Number of elements                    64 elements
 I/O Ports
                                                                                                                      Pulser                                PA Channels                                   UT Channel
 USB ports                      2 USB ports, compliant with USB 2.0 specifications
                                                                                                                      Voltage                               40 V, 80 V, and 115 V                          95 V, 175 V, and 340 V
 Audio alarm                    Yes
                                                                                                                      Pulse width                           Adjustable from 30 ns                         Adjustable from 30 ns to
 Video output                   Video out (SVGA)                                                                                                            to 500 ns; resolution of                      1,000 ns; resolution of
 I/O Lines                                                                                                                                                  2.5 ns                                        2.5 ns
 Encoder                        2-axis encoder line (quadrature, up, down, or clock/                                  Pulse shape                           Negative square wave                          Negative square wave
                                direction)                                                                            Output impedance                      35 Ω (pulse-echo                              <30 Ω
 Digital input                  4 digital TTL inputs, 5 V                                                                                                   mode);
 Digital output                 3 digital outputs TTL, 5 V, 15 mA                                                                                           30 Ω (pitch- catch
                                maximum per output                                                                                                          mode)
 Acquisition on/off switch      Yes, through configuration of a digital input                                         Receiver                              PA Channels                                   UT Channel
 Power output line              5 V, 500 mA power output line                                                         Gain                                  0 dB to 80 dB,                                0 dB to 120 dB maximum
                                (short-circuit protected)                                                                                                   maximum input signal                          input signal 34.5 Vp-p
                                                                                                                                                            550 mVp-p (full-screen                        (full-screen height)
 Pace input                     5 V TTL pace input                                                                                                          height)
 Display                                                                                                              Input impedance                       60 Ω (pulse-echo                              60 Ω (pulse-echo mode);
 Display size                   21.3 cm (8.4 in.) (diagonal)                                                                                                mode);                                        50 Ω (pulse-receive mode)
 Resolution                     800 pixels x 600 pixels                                                                                                     150 Ω (pitch- catch
                                                                                                                                                            mode)
 Brightness                     600 cd/m2
                                                                                                                      System bandwidth                      0.6 MHz to 18 MHz                             0.25 MHz to 28 MHz
 Viewing angles                 Horizontal: –80° to 80° Vertical: –60° to 80°                                                                               (–3 dB)                                       (–3 dB)
 Number of colors               16 million                                                                            Beamforming
 Type                           TFT LCD                                                                               Scan type                             Sectorial or linear
 Power Supply                                                                                                         Group quantity                        1
 Battery type                   Smart Li-ion battery                                                                  Data Acquisition                      PA Channels                                      UT Channel
 Number of batteries            1                                                                                     Digitizing frequency                  100 MHz                                          100 MHz
 Battery life                   Minimum 6 hours under normal operating                                                Maximum pulsing rate                  Up to 6 kHz (C-scan)
                                conditions
                                                                                                                      Data Processing                       PA Channels                                      UT Channel
 Environmental Specifications
                                                                                                                      Number of data points                 Up to 8,192
 Operating temperature          -10 °C to 45 °C
 range                          (14 ºF to 113 ºF)                                                                     Real-time averaging                   PA: 2, 4, 8, 16                                  UT: 2, 4, 8, 16, 32, 64
 Storage temperature range      –20 °C to 60 °C (–4 ºF to 140 ºF) with battery                                        Rectifier                             RF, full wave, half wave +, half wave –
                                –20 °C to 70 °C (–4 ºF to 158 ºF) without battery                                     Filtering                             3 low-pass, 3 band-pass,                         3 low-pass, 6 band-pass,
 Relative humidity              Max. 70% RH at 45°C noncondensing                                                                                           and 5 high-pass filters                          and 3 high-pass filters
                                                                                                                                                                                                             (8 low-pass filters when
 Ingress protection rating      Designed to meet requirements of IP66                                                                                                                                        configured in TOFD)
 Shockproof rating              Drop-tested according to MIL-STD-810G 516.6                                           Video filtering                       Smoothing (adjusted to probe frequency range)
                                                                                                                      Data Visualization
                                                                                                                      A-scan refresh rate                   A-scan: 60 Hz; S-scan: 60 Hz
                                                                                                                      Data Synchronization
                                                                                                                      On internal clock                     1 Hz to 6 kHz
                                                                                                                      On encoder                            On 2 axes: from 1 to 65,536 steps
                                                                                                                      Programmable Time-Corrected Gain (TCG)
                                                                                                                      Number of points                      16: One TCG (time-corrected gain) curve per focal law
                                                                                                                      Maximum slope                         40 dB/10 ns
                                                                                                                      Alarms
                                                                                                                      Number of alarms                      3
              OmniScan MX2           OmniScan SX
If multigroup inspections (ex: two PA probes or combined PA + UT) are                                                 Conditions                            Any logical combination of gates
required or anticipated, Olympus recommends the OmniScan MX2. This
advanced flaw detector's modular platform facilitates the upgrade path —                                           The OmniScan SX meets or exceeds the minimum instrumentation and software
you can start with the module in your price/performance range and upgrade                                          requirements as specified in ASME, AWS, API, and EN codes.
later to one of the many other modules available.
                                                                                                                                         is certified to ISO 9001, ISO 14001, and OHSAS 18001.
                                                                                                                                        *All specifications are subject to change without notice.
www.olympus-ims.com
                                                                                                                                         All brands are trademarks or registered trademarks of their respective owners and third party entities.
                                                                                                                                         Copyright © 2015 by Olympus.
                                        48 Woerd Avenue, Waltham, MA 02453, USA, Tel.: (1) 781-419-3900
                                        12569 Gulf Freeway, Houston, TX 77034, USA, Tel.: (1) 281-922-9300
                                        505, boul. du Parc-Technologique, Québec (Québec) G1P 4S9, Tel.: (1) 418-872-1155
For enquiries - contact                 1109 78 Ave, Edmonton (Alberta) T6P 1L8
www.olympus-ims.com/contact-us
                                                                                                                                                                   OmniScan_SX_EN_LTR_201506 • Printed in the USA • P/N: 920-269-EN Rev. E