0% found this document useful (0 votes)
40 views5 pages

Spec Al Conductor

This 3 page document is a specification from Israel Electric Corp for aluminum stranded conductors. It specifies requirements for 4 conductor sizes including physical and electrical properties, manufacturing standards, testing and inspection, packing on drums. Conductors must meet ISO 9001 and be manufactured according to EN 50182 and EN 60182 standards for concentric lay stranded conductors and hard drawn aluminum wire. Tests will be conducted according to standards at the manufacturer's facility. Packing requirements include standard drum lengths, weights, dimensions and protective internal winding for shipment.

Uploaded by

know dworl
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
40 views5 pages

Spec Al Conductor

This 3 page document is a specification from Israel Electric Corp for aluminum stranded conductors. It specifies requirements for 4 conductor sizes including physical and electrical properties, manufacturing standards, testing and inspection, packing on drums. Conductors must meet ISO 9001 and be manufactured according to EN 50182 and EN 60182 standards for concentric lay stranded conductors and hard drawn aluminum wire. Tests will be conducted according to standards at the manufacturer's facility. Packing requirements include standard drum lengths, weights, dimensions and protective internal winding for shipment.

Uploaded by

know dworl
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Israel Electric Corp. Ltd.

Marketing Division
National Network Unit
Overhead Lines Department
Edition no.: 4
Specification NCS 13
Issued date: May 2012
for aluminum stranded conductors
Page no.: 1 of 10

SPECIFICATION FOR
ALUMINIUM STRANDED CONDUCTORS
Specification NCS 13 - replaces and cancels K 2568

( ‫ ) חתום‬Prepared by: E. Israel

( ‫) חתום‬ Checked by: I. Bester

( ‫ ) חתום‬Approved by: Eng. Y. Samoocha

1
Israel Electric Corp. Ltd.
Marketing Division
National Network Unit
Overhead Lines Department
Edition no.: 4
Specification NCS 13
Issued date: May 2012
for aluminum stranded conductors
Page no.: 2 of 10

Contents:

No. of para. Page No.


1. Scope 3
2. Threshold conditions 3
3. Documents for the proposal 3
4. Manufacturing standards 3
5. Physical and electrical properties 4
6. Tests inspection and reports 4
7. Packing 5
8. Quality assurance 6
9. Quality control 6
10. Delivery approval conditions 6
11. Summary of data 7
12. Revision 8
Appendix 1: Required up to delivery approval 9

Appendices:
1. Standard specification for quality control Q-APP-02 ed. 4.
2. Appendix 1: Required schedule up to delivery approval.

Remark: Specification NCS 13/3 - replaces and cancels K 2568

;‫תנאי סף‬

2
Israel Electric Corp. Ltd.
Marketing Division
National Network Unit
Overhead Lines Department
Edition no.: 4
Specification NCS 13
Issued date: May 2012
for aluminum stranded conductors
Page no.: 3 of 10

1. SCOPE
This specification defines the technical requirements for manufacturing, preserving, packing,
furnishing and delivery to purchaser's storage of concentric-lay-stranded bare conductors
25/50/120/185 mm2, made from hard-drawn round aluminum wires for use as overhead
electrical lines.
I.E.C.'s catalogue number: 42341, 43216, 41632, 42127.

2. THRESHOLD CONDITIONS
According to attached documents of supply and storage division.

3. DOCUMENTS FOR THE PROPOSAL


The Bidder shall submit together with his offer the following documents from the manufacturer:
3.1. Valid ISO 9001 certificate as defined in threshold conditions.
3.2. Reference list of major customers, to whom the proposed items or similar have been
supplied, at least 2 years (in the last 5 years), including sold quantities and dates of supply.
3.3. Type tests reports for the proposed items or for a similar including obligation to submit type
test report for the proposed items upon award of bid, (as indicated in para.6 of this
specification).
3.4. Appendix 1: schedule to delivery approval, signed by the bidder and manufacturer.
3.5. Completed and filled in summary of data.
3.6. The outline drawings of the drums.
All documents and drawings shall be in English or Hebrew.
Bidder which will not submit all the above will be disqualified.
”Similar” means aluminum conductor manufactured by the same technology but in a
different cross sectional area.

4. MANUFACTURING STANDARDS
The conductors shall be manufactured and tested in conformance with the latest published
recommendation of the following standards:
– EN 50182 – Conductors for overhead lines – Round wire concentric lay stranded
conductors.
– EN 60182 – Hard-drawn aluminum wire for overhead line conductors.
– DIN 46391 – Delivery drums.

3
Israel Electric Corp. Ltd.
Marketing Division
National Network Unit
Overhead Lines Department
Edition no.: 4
Specification NCS 13
Issued date: May 2012
for aluminum stranded conductors
Page no.: 4 of 10

5. PHYSICAL AND ELECTRICAL PROPERTIES


5.1. The direction of lay of the external layer shall be right hand.
5.2. The wires shall be of aluminum AL1 of the requisite purity to achieve the mechanical and
electrical properties specified hereinafter. The aluminum content shall be not less than 99.5%.
5.3. The wires shall be smooth and free from all imperfections not consistent with good
commercial practice.
5.4. Complete conductor

1. I.E.C.'s catalogue number 42341 43216 41632 42127


2. Conductor 25 50 120 185
3. Conductor's code according to
24-AL1 49-AL1 117-AL1 182-AL1
EN 50182
4. Cross-sectional area mm2 24.2 49.5 117.0 181.6
5. Number of wires and wire
7×2.10 7×3.00 19×2.80 37×2.50
diameter n×mm
6. Overall diameter of conductor
6.30±0.1 9.00±0.1 14.0±1% 17.5±1%
mm
kg
7. Mass per unit length /km 66.3 135.2 321.5 500.9

8. Rated strength kN 4.36 8.41 19.89 31.78



9. DC resistance /km 1.1787 0.5776 0.2456 0.1588

10. Final modulus of elasticity N/mm2 60000 60000 57000 57000


11. Lay ratios
11.1. All inner layers min-max 10÷16
11.2. Outer layer min-max 10÷14

5.5. Individual wires

1. Conductor 25 50 120 185


2. Diameter and tolerance mm 2.10±0.03 3.00±0.03 2.80±0.03 2.50±0.03
3. Minimum tensile strength MPa 180 170 170 175
4. Resistivity at 20°C nΩm 28.264
kg
5. Density at 20°C /dm3 2.703

6. TESTS INSPECTION AND REPORTS


6.1. Tests (Type and Sample tests) will be made in accordance with the standards mentioned in
par. 4.
6.2. All tests shall be carried out at the manufacturer's works or at a certified laboratory.

4
Israel Electric Corp. Ltd.
Marketing Division
National Network Unit
Overhead Lines Department
Edition no.: 4
Specification NCS 13
Issued date: May 2012
for aluminum stranded conductors
Page no.: 5 of 10

7. PACKING
The conductors shall be supplied as indicates below:
1. Conductor 25 50 120 185
2. Standard length per drum (±5%) m 4500 2000 5000 3200
3. Approx. net weight per drum kg 298 270 1608 1603
7.1. All conductors shall be supplied on non-returnable wooden drums.
7.2. All drums will be internally covered with a chemically neutral material in the winding area,
properly packed and lagged to prevent the conductors from possible damage during shipment.
7.3. An amount not exceeding 5% of the total weight may be shipped in random lengths, none
of which to be shorter than 2/3 of standard length.
7.4. Drum's dimensions:

D1 D2 L D3
Conductor
mm mm mm mm
25
900 450 600 80
50
120
1600 900 1130 80
185
7.5. On both sides of each drum the following data shall be printed on nailed metal label strongly
attached
− Manufacturer's Name
− Manufacturer's Part Number
− I.E.C.'s Order Number
− I.E.C.'s Catalog Number
− Drum Serial Number
− Manufacturing Date
− Conductor Title
− Cross Section area in mm2
− Conductor's length
− Gross weight
− Net weight